At least 127 records · Page 7

The impact of geologic parameters and water infiltration on the imprinting of 133Xe

Recent experiments have shown that atmospheric radioxenon passing over a sampling site can be transported into the shallow subsurface by barometric pressure changes. The STOMP simulator is used to examine the impact of seven hydrologic/geologic parameters and water infiltration on the imprinting of radioxenon from a transient plume during two pressure scenarios. Soil hydraulic conductivity was found to be the dominant factor in the amount of xenon imprinted to two meters, particularly in the case when plume passage coincides with increasing pressure.

Radioxenon, Medical isotope production, Barometric↗

Explosive Byproduct Gas Transport Through Sorptive Geomedia

Current underground nuclear explosion (UNE) detection strategies rely heavily on atmospheric noble gas sampling of radioxenon. However, discriminating nuclear weapons testing programs from civilian sources is difficult due to highly variable atmospheric radioxenon backgrounds and processes affecting subsurface transport of parent radionuclides. Here, we aim to study the transport of gases produced by subsurface explosions as novel stable signatures for underground nuclear explosion (UNE) monitoring. These gases may be produced in large quantities with distinct molecular ratios, which will be impacted by subsurface transport processes. To demonstrate how ratios of gases produced by explosions can change during transport in geomaterials, we conducted laboratory benchtop experiments on the transport of carbon dioxide (CO 2 ) and hydrogen (H 2 ) gases through variably saturated zeolitic tuff, which is abundant at the historic US testing site. We observed that zeolitic tuff sorbs substantial quantities of CO 2 while allowing H 2 to transport more freely, leading to changes in the molecular ratios of the two gases along the transport pathway. Gas uptake in the dry zeolitic tuff core was 72.3% for CO 2 , compared with 53.4% for xenon and 7.6% for H 2 . The presence of 20% water saturation disrupted the CO 2 sorption process, though to a lesser extent than observed for noble gases, with a 36.7% drop in xenon sorption compared with a 21.9% drop for CO 2 . These results represent the first observations of zeolite sorption altering explosive gas ratios during transport through geomedia relevant to nuclear proliferation monitoring.

54 ENVIRONMENTAL SCIENCES↗

The 2014 Integrated Field Exercise of the Comprehensive Nuclear-Test-Ban Treaty revisited: The case for data fusion

The International Monitoring System of the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) uses a global network of radionuclide monitoring stations to detect evidence of a nuclear explosion. The two radionuclide technologies employed—particulate and noble gas (radioxenon) detection—have applications for data fusion to improve detection of a nuclear explosion. Using the hypothetical 0.5 kT nuclear explosive test scenario of the CTBTO 2014 Integrated Field Exercise, the intrinsic relationship between particulate and noble gas signatures has been examined. Here this study shows that, depending upon the time of the radioxenon release, the particulate progeny can produce the more detectable signature. Thus, as both particulate and noble gas signatures are inherently coupled, the authors recommend that the sample categorization schemes should be linked.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Adsorptive Transport of Noble Gas Tracers in Porous Media

The transport of noble gas radionuclides in porous media is relevant to the detection of underground nuclear detonations as well as the sequestration of reprocessing off-gases. However, in field tests releasing radioxenon underground, the quantity of radioxenon observed at the surface has fallen well below expectations1. This study examined the diffusivity of noble gases (Kr and Xe) and the inert molecular gas sulfur hexafluoride (SF6) in porous media to observe any unexpected behavior. To replicate the transport of radiogenic noble gases in underground media, a two-bulb gaseous diffusion apparatus was constructed. The two bulbs are connected with a column of 10-30 Ottawa sand and ordinary atmosphere filled both the bulbs and pore spaces. The tracer gases were diluted in an isolated bulb to approximately 1000 ppm. Once released, the gases were allowed to diffuse through the column. Aliquots were withdrawn at regular time intervals from both bulbs and concentrations were quantified using a Shimadzu QP2010 SE gas chromatograph-mass spectrometer. The effective diffusivity was then calculated using a maximum likelihood estimate on the quasi-steady state model.

Paul, Matthew R.↗

A Figure-of-Merit for Beta Cell Detector Characterization

In order to decrease the minimum detectable activities (MDAs) of beta-gamma radioxenon detectors, it is important to increase the ability to resolve the individual isotopes. One proposed method for doing this is to increase the energy resolution of the beta cell through the use of silicon detectors. While silicon detectors can improve the energy resolution, it is accompanied with a decrease in detection efficiency compared to plastic scintillator beta cells. Due to the uncertainty on the impact of the competing variables, we have developed a figure-of-merit (FOM) capable of determining the impact of detector parameters on the MDAs. By utilizing the FOM to analyze different detectors, we are able to directly compare current and future detectors and estimate their impact on the radioxenon MDAs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

$\beta-\gamma$ Absolute Calibration (Rev. 1)

Identification of nuclear events rely on accurate measurement of radioxenon releases. Measurement of radioxenon relies on accurately knowing the detection efficiency for each isotope. Four xenon isotopes are of interest: 135 Xe, 133 Xe, 133 mXe, and 131 mXe. Each isotope has a unique signature; however, there is overlap between each signature. A series of ratio terms, called interference ratios, helps account for the challenges created by the overlap. The ratio and detection efficiency terms are all determined during the initial detector calibration. Additional spectra are needed for a complete calibration: the radon daughter 214 Pb/ 214 Bi, the detector background, and the 137 Cs quality control (QC).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A TREATMENT OF THE MEASUREMENT UNCERTAINTY FOR XENON VOLUME QUANTIFICATION

Treaty monitoring gas measurement systems that measure radioxenon typically report results as an activity concentration, which is the measured radioxenon activity divided by the amount of stable xenon present. While the nuclear activity uncertainty has been studied in detail and is driven primarily by counting statistics, the uncertainty for the volume measurement has been considered in less detail. A framework for a more complete consideration of the uncertainty for the volume measurement has been developed. This type of analysis can help drive the system requirements for the volume quantification while the system is still being developed or added to advanced fielded systems. Depending on the accuracy requirements for the activity concentration, the volume quantification measurement and analysis can be developed to a suitably high level of accuracy. Nominally, it is best to have the activity concentration uncertainty limited by the uncertainty of the activity measurement because it tends to be fundamentally limited by the counting statistics. Volume quantification should be performed more accurately so that the activity concentration uncertainty is not degraded from the counting statistics. This paper will describe in detail a stable gas quantification uncertainty analysis for a xenon monitoring system.

Harper, Warren W.↗

Analyzing existing and planned nuclear facilities as potential sources for unusual xenon radionuclides (127Xe, 129mXe, 125Xe, 122Xe)

Unusual xenon radionuclides (127Xe, 129mXe, 125Xe, 122Xe) were observed during temporary operation of a radioxenon monitoring station in the vicinity of a high flux nuclear reactor and a spallation neutron source. Meteorological modeling showed that these two facilities were the most likely source of these emissions. Because 127Xe by itself, and this mix of radionuclides together can lead to false-positive reports for the four xenon radionuclides of interest (135Xe, 133Xe, 133mXe, and 131mXe), it is important for radioxenon monitoring station operators to be aware of potential sources of these interfering radionuclides. This work will look at the location and source intensities of both high flux nuclear reactors, and spallation neutron sources around the world, to see if the potential exists in other regions for production and observance of the unusual xenon radionuclides (127Xe, 129mXe, 125Xe, 122Xe).

07 ISOTOPE AND RADIATION SOURCES↗

Digital Data Acquisition Graphical User Interface

Traditional radioxenon measurements have been done by ground based fixed systems, however in recent years there has been an increased need for systems capable of quick deployment or even complete mobility. Using the Pixie-4 data acquisition (DAQ) system can help reduce the electronics footprint of both current systems, like the radioxenon Radionuclide Laboratory 16 (RL-16) and the Swedish Automatic Unit for Noble Gas Acquisition (SAUNA), as well as future systems. Pacific Northwest National Laboratory (PNNL) has developed a Linux based Nyx graphical user interface (GUI) for Pixie-4 cards. The Nyx software can be installed on various Linux platforms and is written in C++. This software offers a rich user interface for configuring and operating the Pixie4 card and PNNL designed high voltage (HV) cards. Nyx allows one to quickly get a nuclear detector operational by maintaining the core diagnostic features built into the Pixie-4 cards. First, Nyx maintains the multitude of adjustable parameters accessible in the Pixie-4 cards, which allows one to customize settings to take full advantage of a particular detector. Nyx also maintains an oscilloscope feature which is extremely useful to optimize settings and to verify proper detector behavior and is often the first feature used in Nyx during detector setup. Finally, Nyx allows the user to collect data in several formats including full pulse shapes to basic histograms. Overall, it is the corner stone for the transition of beta-gamma systems to a state-of-the-art digitizing DAQ.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Concentration Independent Calibration of β-γ Coincidence Detector Using 131mXe and 133Xe

Absolute efficiency calibration of radiometric detectors is frequently difficult and requires careful detector modeling and accurate knowledge of the radioactive source used. In the past we have calibrated the b-g coincidence detector of the Automated Radioxenon Sampler/Analyzer (ARSA) using a variety of sources and techniques which have proven to be less than desirable.[1] A superior technique has been developed that uses the conversion-electron (CE) and x-ray coincidence of 131mXe to provide a more accurate absolute gamma efficiency of the detector. The 131mXe is injected directly into the beta cell of the coincident counting system and no knowledge of absolute source strength is required. In addition, 133Xe is used to provide a second independent means to obtain the absolute efficiency calibration. These two data points provide the necessary information for calculating the detector efficiency and can be used in conjunction with other noble gas isotopes to completely characterize and calibrate the ARSA nuclear detector. In this paper we discuss the techniques and results that we have obtained.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis of 125 Xe electron–photon coincidence decay

In this study, as part of the verification component of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), environmental gas samples originating from nuclear fission are analyzed for the presence of 131 mXe, 133 mXe, 133 Xe, and 135 Xe. In this work, the non-traditional radioxenon isotope 125 Xe was investigated. The isotope was produced as an isotopically pure sample via neutron activation of 124 Xe at the University of Texas at Austin Nuclear Engineering Teaching Lab’s TRIGA MARK II Reactor. The sample was then measured using a HPGe detector as well as an ARSA-style β–γ coincidence detector. Potential sources and sensitivities for production of 125 Xe are also considered for relevance to the CTBT verification mission.

CTBT↗

Method for calculating radon activity and radon rejection using a beta-gamma detector

Radon interferes with concentration measurements used by atmospheric radioxenon systems. We demonstrate a method to quantify the amount of radon that is present in the detectors, the impact of radon activity on the minimum-detectable-concentrations, and how to determine the needed radon rejection levels. An example calculation shows a radon rejection level of 10 5 is sufficient to limit impact on the detector sensitivity. We anticipate this method will give analysist a better understanding of radon present in their measurements and allow system designers to tailor their systems’ radon rejection better for its location.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

An Experimental Method to Measure Gaseous Diffusivity in Tight and Partially Saturated Porous Media via Continuously Monitored Mass Spectrometry

Detection of radioxenon and radioargon produced by underground nuclear explosions is one of the primary methods by which the Comprehensive Nuclear-Test–Ban Treaty (CTBT) monitors for nuclear activities. However, transport of these noble gases to the surface via barometric pumping is a complex process relying on advective and diffusive processes in a fractured porous medium to bring detectable levels to the surface. To better understand this process, experimental measurements of noble gas and chemical surrogate diffusivity in relevant lithologies are necessary. However, measurement of noble gas diffusivity in tight or partially saturated porous media is challenging due to the transparent nature of noble gases, the lengthy diffusion times, and difficulty maintaining consistent water saturation. Here, the quasi-steady-state Ney–Armistead method is modified to accommodate continuous gas sampling via effusive flow to a mass spectrometer. An analytical solution accounting for the cumulative sampling losses and induced advective flow is then derived. Experimental results appear in good agreement with the proposed theory, suggesting the presence of retained groundwater reduces the effective diffusivity of the gas tracers by 10–1000 times. Finally, by using a mass spectrometer, the method described herein is applicable to a broad range of gas species and porous media.

47 OTHER INSTRUMENTATION↗

Interference Terms for Xenon-135

Systems to measure radioxenon concentrations are continually being improved to provide greater sensitivity and precision. As the systems become more capable, additional terms need to be added to the calculations to account for small previously insignificant effects such as minor decay branches. Recently, additional terms present in the {sup 135}Xe decay were added to the calculations to account for the small (5.2%) fraction of decays that produce cesium K-shell x-rays with an average energy of 32 keV and the Compton scatter of the dominant 250-keV gamma ray. These events overlap with the regions of interest of {sup 133}Xe, {sup 131m}Xe, and {sup 133m}Xe. In typical field applications, the amount of expected {sup 135}Xe is low due to the short half-life (9.14 hours) therefore the small fraction that could be mis-categorized as other isotopes is insignificant in most cases. However, for much more active samples, such as those recently measured in calibration and testing samples with high activity, the amount of mis-categorization can be significant. The additions to the calculations use calibration values to estimate the amount of a possible interference of {sup 135}Xe in the other regions of interest, which are then subtracted out. The calibration values, which are ratios of counts in one region of interest to another, are obtained by measuring with single isotope gases during the calibration process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of environmental backgrounds on atmospheric monitoring of nuclear explosions

Radionuclide monitoring for nuclear explosions includes measuring radioactive aerosol and noble gas concentrations in the atmosphere. The International Monitoring System (IMS) of the Comprehensive Nuclear Test Ban Treaty (CTBT) has made such measurements for decades, revealing much about how atmospheric radioactivity impacts the sensitivity of the network. For example, civilian emissions of radioiodine make a substantial regional impact, but a minor global impact, while civilian radioxenon emissions create major regional and complex global impacts. This example statement is strongly influenced by the minimum signal level anticipated to be interesting. The original design of the IMS anticipated relatively large signal levels, and the accomplished IMS network substantially meets or exceeds the sensitivity needed to detect those signal levels. Much lower signal levels can be motivated, which could require reconsideration of station sensitivity. Using measured and simulated background concentrations, various possible desired signal levels, and an innovative anomaly threshold, maps of sensitivity and a station ranking are developed for current and future stations. These provide a strong motivation for additional experimentation to learn about sources and the potential plusses of new technology.

Eslinger, Paul W.↗

Degradation of 81 keV 133Xe Gamma-Rays into the 31 keV X-Ray Peak in CsI Scintillators

ABSTRACT Pacific Northwest National Laboratory uses beta-gamma coincidence detectors in a number of xenon sampling and/or measurement systems to enable simultaneous, sensitive measurements of 131Xe, 133Xe, 133mXe, and 135Xe for treaty monitoring applications. In recent years, a new style of beta-gamma detector was developed to improve upon the detector module used in the Automated Radioxenon Sampler/Analyzer. The results of an MCNP5 Monte Carlo simulation of the new detector cell are presented, with particular emphasis on the identification of an energy deposition sequence with the potential to introduce significant error into the detector efficiency calibration. This sequence occurs when an 81 keV gamma from 133Xe is absorbed in an inactive region of the CsI(Na) scintillator, followed by emission of a 31 keV x-ray from cesium (or possibly a 28.5 keV x-ray from iodine). These x-rays add excess counts into the 31 keV peak observed in the decay of 133Xe. The impact of this effect on different efficiency calibration techniques is discussed.

133Xe, CsI Scintillators↗

Tracers for radiopharmaceutical production facilities

When radiopharmaceutical production facilities irradiate uranium targets for the production of radionuclides such as 99Mo, the emissions interfere with the global monitoring efforts conducted by the Comprehensive Nuclear-Test-Ban Treaty Organization. While suppressing emissions from such facilities would be ideal, it is understood that radioxenon emissions may not be reduced to levels below detectable quantities. As a result, a study was conducted to investigate tracers that may be utilized for source identification upon measurement. Both radioactive and stable tracers were evaluated.

Biegalski, Steven R.↗

Consideration of impact of atmospheric intrusion in subsurface sampling for investigation of suspected underground nuclear explosions

Radioactive noble gases radioxenon and radioargon constitute the primary smoking gun of an underground nuclear explosion. The aim of subsurface sampling of soil gas as part of an on-site inspection (OSI) is to search for evidence of a suspected underground nuclear event. It has been hypothesized that atmospheric gas can disturb soil gas concentrations and therefore potentially add to problems in civilian source discrimination verifying treaty compliance under the comprehensive nuclear-test-ban treaty. Furthermore, this work describes a study of intrusion of atmospheric air into the subsurface and its potential impact on an OSI using results of simulations from the underground transport of environmental xenon (UTEX) model.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗