Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulse shape discrimination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A wearable sensor based on CLYC scintillators

We developed a wearable radiation sensor using Cs 2 LiYCl 6 :Ce (CLYC) for simultaneous gamma-ray and neutron detection. The system includes two ø2.5×2.5 cm 3 crystals coupled to small, metal-body photomultiplier tubes. A custom, low-power electronics base digitizes the output signal at three time points and enables both pulse height and pulse shape discrimination of neutrons and gamma-rays. Data, including spectra, can be transferred via a wired or wireless connection. The total gamma-ray and neutron counts, anomaly detection metrics, and identified isotopes are displayed on a small screen on the device. Users may leave the system in unattended mode to collect long-dwell energy spectra. The prototype system has overall dimensions of 13×7.5×18 cm 3 and weight of 1.3 kg, not including the protective pouch, and runs on six AA alkaline batteries for 29 hours with a 1% wireless transmission duty cycle and 41 hours with the wireless turned off . In this paper, we summarize the system design and present characterization results from the detector modules. The energy resolution is about 6.5% full width at half maximum at 662 keV due to the small photomultiplier tube selected, and the linearity and pulse shape discrimination performance are very good.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deuterated-xylene (xylene-d 10 ; EJ301D): A new, improved deuterated liquid scintillator for neutron energy measurements without time-of-flight

In conjunction with Eljen Technology, Inc. (Sweetwater,TX) we have designed, constructed, and evaluated a 3 in. x 3 in. deuterated-xylene organic liquid scintillator (C 8 D 10 ; EJ301D) as a fast neutron detector. Similar to deuterated benzene (C 6 D 6 ; NE230, BC537, and E1315) this scintillator can provide good pulse shape discrimination between neutrons and gamma rays, has good timing characteristics, and can provide a light spectrum with peaks corresponding to discrete neutron energy groups up to ca. 20 MeV. Unlike benzene -based detectors, deuterated xylene is less volatile, less toxic, is not known to be carcinogenic, has a higher flashpoint, and hence is much safer for many applications. In addition E1301D can provide slightly more light output and better PSD than deuterated-benzene scintillators. We show that, as with deuterated-benzene scintillators, the light -response spectra can be unfolded to provide useable neutron energy spectra without need for time-of-flight (ToF). An array of these detectors arranged at many angles close to a reaction target can be much more effective ( x 10 to x 100 or more) than an array of long-path ToF detectors which must utilize a narrowly-bunched and pulse-selected beam. Here, as we demonstrate using a small Van de Graaff accelerator, measurements can thus be performed when a bunched and pulse -selected beam (as needed for time-of-flight) is not available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress Toward A $2νββ$ Measurement For The M AJORNA D EMONSTRATOR

The M AJORNA D EMONSTRATOR is a 76 Ge-based neutrinoless double-beta decay (0 νββ ) experiment. Staged at the 4850 ft level of the Sanford Underground Research Facility, the D EMONSTRATOR operates an array of high-purity p-type point contact Ge detectors deployed within a graded passive shield and an active muon veto system. The present work concerns the two-neutrino double-beta decay mode (2 νββ ) of 76 Ge. For Ge detectors, having superior energy resolution (0.1%), this mode poses negligible background to the 0 νββ mode, even for a ton-scale experiment. However, the measurement of the 2 νββ mode allows for careful systematics checks of active detector mass, enrichment fraction, and pulse shape discrimination cuts related to both the 0 νββ and 2 νββ decay modes. A precision measurement of the 2 νββ shape also allows searches for spectral distortions, possibly indicative of new physics, including 0 νββχ . Work is underway to construct a full experimental background model enabling a Bayesian fit to the measured energy spectrum and extraction of a precise 2 νββ spectrum and half-life.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron light output function and resolution investigation of the deuterated organic liquid scintillator EJ-315

Here, we investigate the light response to fast neutrons and estimate the pulse height resolution of a deuterated liquid organic scintillator, EJ-315, considering the detector's non-linear light response to gamma-rays. Initially, collision data and a neutron beam trigger are recorded in coincidence mode, and incident neutron energy is calculated with a time-of-flight technique. Fast neutrons are further discriminated from gamma-ray background based on the scintillation material decay patterns using a pulse shape discrimination algorithm. We also derived a light response matrix composed of multiple neutron energy and their corresponding light outputs. The pulse height resolution property of the EJ-315 is characterized utilizing the derivatives of the pulse height distributions with corrections of the mea-surements setup uncertainties. In addition, the EJ-315's pulse height resolution is also characterized by comparing the smoothed derivatives of quasi-monoenergetic neutron pulse height distributions, given by the Peierls-formula-based analytic model, to match the measurement data. Results show rather consistent 10e13% pulse resolution for mono-energetic neutrons with kinetic energy above 2 MeV. The resolution decreases slightly with an increase in neutron energy indicating the improved resolution performance of EJ-315 in the higher energy events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of metal organic fluors for spectral discrimination of neutrons and gammas.

A new method for spectral shape discrimination (SSD) of fast neutrons and gamma rays has been investigated. Gammas interfere with neutron detection, making efficient discrimination necessary for practical applications. Pulse shape discrimination (PSD) in liquid organic scintillators is currently the most effective means of gamma rejection. The hazardous liquids, restrictions on volume, and the need for fast timing are drawbacks to traditional PSD scintillators. In this project we investigated harvesting excited triplet states to increase scintillation yield and provide distinct spectral signatures for gammas and neutrons. Our novel approach relies on metal-organic phosphors to convert a portion of the energy normally lost to the scintillation process into useful luminescence with sub-microsecond lifetimes. The approach enables independent control over delayed luminescence wavelength, intensity, and timing for the first time. We demonstrated that organic scintillators, including plastics, nanoporous framework materials, and oil-based liquids can be engineered for both PSD and SSD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scintillation Properties of a Cs2LiLa(Br6)90%(Cl6)10%:Ce (CLLBC) Crystal

In investigations of Ce3+-doped Cs2LiLa(Br6)90%(Cl6)10% (CLLBC) elpasolite crystals, the crystals show an excellent neutron and gamma (n/g) radiation response. The results of our studies on the scintillation properties of CLLBC viz. radioluminescence, energy resolution, light yield, decay times, and nonproportionality are discussed. The CLLBC detector can provide energy resolution as good as 4.1% at 662 keV (FWHM), which is better than that of NaI:Tl. Because the crystal contains 6Li, CLLBC can also detect thermal neutrons. In the energy spectra, the full energy thermal neutron peak appears near or above 3 MeV gamma equivalent energy. This high-energy signature for the thermal neutron peak means that very effective pulse height discrimination is possible. Unfortunately, because the core-to-valence luminescence observed in other elpasolites that can be exploited for effective pulse shape discrimination (PSD) is not observed in the CLLBC, other strategies for obtaining the PSD of CLLBC are needed. The n/g discrimination capability of CLLBC detectors may be optimized by tuning the cerium doping content for maximum effect on n/g pulse shape differences. The value of adding a chlorine component to the nominal CLLB crystal is discussed. Because the crystal contains chlorine, its sensitivity to fast neutrons is better than that of Cs2LiLaBr6 (CLLB). Further, an array of three of these CLLBC detectors may be able to perform directional detection in both the neutron and gamma channels simultaneously.

36 MATERIALS SCIENCE↗

Measurement of Neutron Yields from UF4

We have performed measurements of neutron production from UF{sub 4} samples using liquid scintillator as the detector material. Neutrons and gamma rays were separated by a multichannel digital pulse shape discriminator, and the neutron pulse-height spectra were unfolded using sequential least-squares optimization with an active set strategy. The unfolded spectra were compared to estimates calculated with the SOURCES 4C code.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Neutron Yields from UF4

We have performed measurements of neutron production from UF4 samples using liquid scintillator as the detector material. Neutrons and gamma rays were separated by a multichannel digital pulse shape discriminator, and the neutron pulse-height spectra were unfolded using sequential least-squares optimization with an active set strategy. The unfolded spectra were compared to estimates calculated with the SOURCES 4C code.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pulse discrimination with a Gaussian mixture model on an FPGA

A Gaussian Mixture Model (GMM) based machine learning algorithm has been applied to the problem of gamma/neutron pulse shape discrimination (PSD). The algorithm has been successfully implemented on a standard PC as well as a field programmable gate array (FPGA). We describe the GMM classifier and its implementation on these two different types of hardware. We compare the performance of the algorithm on these two platforms against each other, along with other standard techniques applied in PSD. Our results show that the FPGA-based GMM classifier outperforms the standard PSD techniques in terms of classification accuracy at low particle energy and executes more quickly than its CPU-based counterpart.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Long Range Active Detection of HEU Based on Thermal Neutron Multiplication

We report on the results of measurements of proton irradiation on a series of targets at Brookhaven National Laboratory’s (BNL) Alternate Gradient Synchrotron Facility (AGS), in collaboration with LANL and SNL. We examined the prompt radiation environment in the tunnel for the DTRA-sponsored series (E 972), which investigated the penetration of air and subsequent target interaction of 4 GeV proton pulses. Measurements were made by means of an organic scintillator with a 500 MHz bandwidth system. We found that irradiation of a depleted uranium (DU) target resulted in a large gamma-ray signal in the 100-500 µsec time region after the proton flash when the DU was surrounded by polyethylene, but little signal was generated if it was surrounded by boron-loaded polyethylene. Subsequent Monte Carlo (MCNPX) calculations indicated that the source of the signal was consistent with thermal neutron capture in DU. The MCNPX calculations also indicated that if one were to perform the same experiment with a highly enriched uranium (HEU) target there would be a distinctive fast neutron yield in this 100-500 µsec time region from thermal neutron-induced fission. The fast neutrons can be recorded by the same direct current system and differentiated from gamma ray pulses in organic scintillator by pulse shape discrimination.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Proton discrimination in CLYC for fast neutron spectroscopy

The Cs 2 LiYCl 6 :Ce (CLYC) elpasolite scintillator is known for its response to fast and thermal neutrons along with good γ-ray energy resolution. While the 35 Cl(n,p) reaction has been identified as a potential means for CLYC-based fast neutron spectroscopy in the absence of time-of-flight (TOF), previous efforts to functionalize CLYC as a fast neutron spectrometer have been thwarted by the inability to isolate proton interactions from 6 Li(n,α) and 35 Cl(n,α) signals. This work introduces a new approach to particle discrimination in CLYC for fission spectrum neutrons using a multi-gate charge integration algorithm that provides excellent separation between protons and heavier charged particles. Neutron TOF data were collected using a 252 Cf source, an array of EJ-309 organic liquid scintillators, and a 6 Li-enriched CLYC scintillator outfitted with fast electronics. Modal waveforms were constructed corresponding to the different reaction channels, revealing significant differences in the pulse characteristics of protons and heavier charged particles at ultrafast, fast, and intermediate time scales. These findings informed the design of a pulse shape discrimination algorithm, which was validated using the TOF data. This study also proposes an iterative subtraction method to mitigate contributions from confounding reaction channels in proton and heavier charged particle pulse height spectra, opening the door for CLYC-based fast neutron and γ-ray spectroscopy while preserving sensitivity to thermal neutron capture signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A functional form for liquid scintillator pulse shapes

Digitization of detector signals enables analysis of the original waveform to extract timing, particle identification, and energy deposition information. Here we present the use of analytical functions based on sigmoids to model and fit such pulse shapes from liquid organic scintillators, though the method should also be applicable to other detector systems. Neutron and gamma interactions in NE213 detectors were digitized from the phototube anode and fit using a sigmoid-based function. The acuity of the fit in extracting timing information and performing neutron-gamma pulse-shape discrimination are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavelength-Shifting-Fiber Scintillation Detectors for Thermal Neutron Imaging at SNS

We have developed wavelength-Shifting-fiber Scintillator Detector (SSD) with 0.3 m2 area per module. Each module has 154 x 7 pixels and a 5 mm x 50 mm pixel size. Our goal is to design a large area neutron detector offering higher detection efficiency and higher count-rate capability for Time-Of-Flight (TOF) neutron diffraction in Spallation Neutron Source (SNS). A ZnS/6LiF scintillator combined with a novel fiber encoding scheme was used to record the neutron events. A channel read-out-card (CROC) based digital-signal processing electronics and position-determination algorithm was applied for neutron imaging. Neutron-gamma discrimination was carried out using pulse-shape discrimination (PSD). A sandwich flat-scintillator detector can have detection efficiency close to He-3 tubes (about 10 atm). A single layer flat-scintillator detector has count rate capability of 6,500 cps/cm2, which is acceptable for powder diffractometers at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Handheld readout electronics to fully exploit the particle discrimination capabilities of elpasolite scintillators

In this study, a new class of elpasolite scintillators has garnered recent attention due to the ability to perform as simultaneous gamma spectrometers and thermal neutron detectors. Such a dual-mode capability is made possible by pulse-shape discrimination (PSD), whereby the emission waveform profiles of gamma and neutron events are fundamentally unique. To take full advantage of these materials, we have developed the Compact Advanced Readout Electronics for Elpasolites (CAREE). This handheld instrument employs a multi-channel PSD-capable ASIC, custom micro-processor board, front-end electronics, power supplies, and a 2 in. photomultiplier tube for readout of the scintillator. The unit is highly configurable to allow for performance optimization amongst a wide sample of elpasolites which provide PSD in fundamentally different ways. We herein provide an introduction to elpasolites, then describe the motivation for the work, mechanical and electronic design, and preliminary performance results.

42 ENGINEERING↗

Tomographic analysis of neutron and gamma pulse shape distributions from liquid scintillation detectors at Joint European Torus

The Joint European Torus (JET, Culham, UK) is the largest tokamak in the world devoted to nuclear fusion experiments of magnetic confined Deuterium (D)/Deuterium-Tritium (DT) plasmas. Neutrons produced in these plasmas are measured using various types of neutron detectors and spectrometers. Two of these instruments on JET make use of organic liquid scintillator detectors. The neutron emission profile monitor implements 19 liquid scintillation counters to detect the 2.45 MeV neutron emission from D plasmas. A new compact neutron spectrometer is operational at JET since 2010 to measure the neutron energy spectra from both D and DT plasmas. Liquid scintillation detectors are sensitive to both neutron and gamma radiation but give light responses of different decay time such that pulse shape discrimination techniques can be applied to identify the neutron contribution of interest from the data. The most common technique consists of integrating the radiation pulse shapes within different ranges of their rising and/or trailing edges. In this article, a step forward in this type of analysis is presented. The method applies a tomographic analysis of the 3-dimensional neutron and gamma pulse shape and pulse height distribution data obtained from liquid scintillation detectors such that n/γ discrimination can be improved to lower energies and additional information can be gained on neutron contributions to the gamma events and vice versa.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficient Prompt Scintillation and Fast Neutron-Gamma Ray Discrimination Using Amorphous Blends of Difluorenylsilane Organic Glass and in-situ Polymerized Vinyltoluene

High performance radiation detection materials are an integral part of national security, medical imaging, and nuclear physics applications. Those that offer compositional and manufacturing versatility are of particular interest. In this work, we report a new family of radiological particle-discriminating scintillators containing bis(9,9-dimethyl-9H-fluoren-2- yl)diphenylsilane (compound “P2”) and in-situ polymerized vinyltoluene (PVT) that is phase stable and mechanically robust at any blend ratio. The gamma-ray light yield increases nearly linearly across the composition range, to ~16,400 photons/MeV at 75 % wt. P2. These materials are also capable of γ/n pulse shape discrimination (PSD) and between 20-50 % P2 loading are competitive with the PSD quality of commercially-available plastic scintillators. The 137 Cs scintillation rise and decay times are sensitive to P2 loading and approach the values for “pure” P2. Additionally, the radiation detection performance of P2-PVT blends can be made stable in 60°C air for at least 1.5 months with the application of a thin film of poly(vinylalcohol) to the scintillator surfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Energy Measurements in Emergency Response Applications

We present significant results in recent advances in the measurement of neutron energy. Neutron energy measurements are a small but significant part of radiological emergency response applications. Mission critical information can be obtained by analyzing the neutron energy given off from radioactive materials. In the case of searching for special nuclear materials, neutron energy information from an unknown source can be of importance. At the Remote Sensing Laboratory (RSL) of National Security Technologies, LLC, a series of materials, viz., liquid organic scintillator (LOS), Lithium Gadolinium Borate (LGB) or Li6Gd(BO3)3 in a plastic matrix, a recently developed crystal of Cesium Lithium Yttrium Chloride, Cs2LiYCl6: Ce (called CLYC)[1], and normal plastic scintillator (BC-408) with 3He tubes have been used to study their effectiveness as a portable neutron energy spectrometer. Comparisons illustrating the strengths of the various materials will be provided. Of these materials, LGB offers the ability to tailor its response to the neutron spectrum by varying the isotopic composition of the key constituents (Lithium, Gadolinium [Yttrium], and Boron). All three of the constituent elements possess large neutron capture cross section isotopes for highly exothermic reactions. These compounds of composition Li6Gd(Y)(BO3)3 can be activated by Cerium ions Ce3+. CLYC, on the other hand, has a remarkable gamma response in addition to superb neutron discrimination, comparable to that of Europium-doped Lithium Iodide (6LiI: Eu). Comparing these two materials, CLYC has higher light output (4500 phe/MeV) than that from 6LiI: Eu and shows better energy resolution for both gamma and neutron pulse heights. Using CLYC, gamma energy pulses can be discriminated from the neutron signals by simple pulse height separation. For the cases of both LGB and LOS, careful pulse shape discrimination is needed to separate the gamma energy signals from neutron pulses. Both analog and digital methods have been applied to obtain a clear gamma and neutron energy spectrum in a mixed radiation field. A waveform digitizer manufactured by Agilent Technology Inc. has been successfully used to digitize the signal and separate the gamma and neutron signals to obtain a high gamma rejection ratio. These results along with some interesting data from a plastic (BC-408) and 3He dual gamma-neuron detector will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applications of C 7 LYC scintillators in fast neutron spectroscopy

Here, the capabilities of 7 Li-enriched Cs 2 7 LiYCl 6 (C 7 LYC) scintillation detectors for fast neutron spectroscopy are explored in benchmark experiments that exploit its excellent pulse-shape discrimination between neutrons and γ rays, and its unprecedented ≈10% energy resolution for fast neutrons in the few MeV range, obtained through the 35 Cl(n,p) reaction. Energy- and angle-resolved elastic and inelastic neutron scattering cross-section measurements of 56 Fe(n,n’) were performed at Los Alamos National Laboratory with a pulsed white neutron source and an array of 1" x 1" C 7 LYC crystals. The results convincingly establish the utility of this dual n/γ scintillator for fast neutron spectroscopy. Intrinsic efficiency measurements of both 1" x 1" and the first ever 3" x 3" C 7 LYC crystal have been initiated, using mono-energetic fast neutron beams at UMass Lowell generated via the 7 Li(p,n) reaction. Finally, the spectroscopic capabilities and potential of C 7 LYC are discussed in the context of developing this emerging scintillator for targeted science applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗