Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

JLab E07-011: Precision measurements of g{sub 1}{sup d} using ND{sub 3} and LiD

We plan to make definitive measurements of the deuteron spin structure function g{sub 1}{sup d}/F{sub 1}{sup d} in the deep-inelastic kinematics accessible with a 6 GeV beam at JLab. The principal goal is to provide the low Q{sup 2} anchor points for NLO pQCD plus higher twist fits to g{sub 1}{sup d}/F{sub 1}{sup d}, which is particularly sensitive to DELTAG(x)(the polarized gluon density of the nucleon) and the sum of up and down quark polarizations. By spanning a factor of typically two in the Q{sup 2}-range at nine values of x, the new data will strongly constrain the higher twist contribution to the fits, with a corresponding reduction in the polarized PDF uncertainties. The proposed measurements, when combined with existing and planned world data at higher Q{sup 2}, will provide the theoretically cleanest determination of DELTAG(x) in the moderate to high x region, and will provide a necessary complement to the low x program of RHIC-spin.The experiment will use both {sup 6}LiD and ND{sub 3} as a source of polarized deuterons, with approximately equal running times for both to constrain the nuclear effects in {sup 6}LiD, the target used by the higher Q{sup 2} experiments at SLAC and CERN. Both the target and low current (nA scale) 6 GeV electron beam will be longitudinally polarized. Electrons scattered at angles from about 18 deg. to 45 deg. will be detected. Additional measurements at lower Q{sup 2} will be made using a 4.8 GeV beam energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High precision spectrometers for very forward protons in CMS

We plan to add proton tracking and timing detectors at $z$ = 240-250 m on both sides of CMS to study central exclusive production, with one or both protons measured, and single diffraction. They provide measurements of $p+p \rightarrow p + X + p$, where $X = Z, H, W^+W^-$ and multiparticle states (with or without jets), as well as single high mass diffraction in low pile-up runs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Atomically precise (catalytic) particles synthesized by a novel cluster deposition instrument

We report a new high vacuum instrument which is dedicated to the preparation of well-defined clusters supported on model and technologically relevant supports for catalytic and materials investigations. The instrument is based on deposition of size selected metallic cluster ions that are produced by a high flux magnetron cluster source. The throughput of the apparatus is maximized by collecting and focusing ions utilizing a conical octupole ion guide and a linear ion guide. The size selection is achieved by a quadrupole mass filter. The new design of the sample holder provides for the preparation of multiple samples on supports of various sizes and shapes in one session. After cluster deposition onto the support of interest, samples will be taken out of the chamber for a variety of testing and characterization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The laser micro-machining system for diamond anvil cell experiments and general precision machining applications at the High Pressure Collaborative Access Team

We report we have designed and constructed a new system for micro-machining parts and sample assemblies used for diamond anvil cells and general user operations at the High Pressure Collaborative Access Team, sector 16 of the Advanced Photon Source. The new micro-machining system uses a pulsed laser of 400 ps pulse duration, ablating various materials without thermal melting, thus leaving a clean edge. With optics designed for a tight focus, the system can machine holes any size larger than 3 μm in diameter. Unlike a standard electrical discharge machining drill, the new laser system allows micro-machining of non-conductive materials such as: amorphous boron and silicon carbide gaskets, diamond, oxides, and other materials including organic materials such as polyimide films (i.e., Kapton). An important feature of the new system is the use of gas-tight or gas-flow environmental chambers which allow the laser micro-machining to be done in a controlled (e.g., inert gas) atmosphere to prevent oxidation and other chemical reactions in air sensitive materials. The gas-tight workpiece enclosure is also useful for machining materials with known health risks (e.g., beryllium). Specialized control software with a graphical interface enables micro-machining of custom 2D and 3D shapes. The laser-machining system was designed in a Class 1 laser enclosure, i.e., it includes laser safety interlocks and computer controls and allows for routine operation. Though initially designed mainly for machining of the diamond anvil cell gaskets, the laser-machining system has since found many other micro-machining applications, several of which are presented here.

47 OTHER INSTRUMENTATION↗

Non-degenerate two photon absorption enhancement for laser dyes by precise lock-in detection

This study demonstrates a measurement system for a non-degenerate two-photon absorption (NDTPA) spectrum. The NDTPA light sources are a white light super continuum beam (WLSC, 500 ∼ 720 nm) and a fundamental beam (798 nm) from a Ti:Sapphire laser. A reliable broadband NDTPA spectrum is acquired in a single-shot detection procedure using a 128-channel lock-in amplifier. The NDTPA spectra for several common laser dyes are measured. Two photon absorption cross section enhancements are found in the experiment and validated by theoretical calculation for all of the chromophores.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray diffraction gratings: Precise control of ultra-low blaze angle via anisotropic wet etching

Diffraction gratings are used from micron to nanometer wavelengths as dispersing elements in optical instruments. At shorter wavelengths, crystals can be used as diffracting elements, but due to the 3D nature of the interaction with light are wavelength selective rather than wavelength dispersing. There is an urgent need to extend grating technology into the x-ray domain of wavelengths from 1 to 0.1 nm, but this requires the use of gratings that have a faceted surface in which the facet angles are very small, typically less than 1°. Small facet angles are also required in the extreme ultra-violet and soft x-ray energy ranges in free electron laser applications, in order to reduce power density below a critical damage threshold. In this work, we demonstrate a technique based on anisotropic etching of silicon designed to produce very small angle facets with a high degree of perfection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A PRECISION PHOTOMETRIC COMPARISON BETWEEN SDSS-II AND CSP TYPE Ia SUPERNOVA DATA

Consistency between Carnegie Supernova Project (CSP) and SDSS-II Supernova Survey ugri measurements has been evaluated by comparing Sloan Digital Sky Survey (SDSS) and CSP photometry for nine spectroscopically confirmed Type Ia supernova observed contemporaneously by both programs. The CSP data were transformed into the SDSS photometric system. Sources of systematic uncertainty have been identified, quantified, and shown to be at or below the 0.023 mag level in all bands. When all photometry for a given band is combined, we find average magnitude differences of equal to or less than 0.011 mag in ugri, with rms scatter ranging from 0.043 to 0.077 mag. The u-band agreement is promising, with the caveat that only four of the nine supernovae are well observed in u and these four exhibit an 0.038 mag supernova-to-supernova scatter in this filter.

79 ASTRONOMY AND ASTROPHYSICS↗

Precise absolute γ -ray and β - -decay branching intensities in the decay of Cu 29 67

In this work, absolute γ-ray emission probabilities in the β - decay of 67 Cu were measured by means of γ-ray and β - -decay singles and β - -γ coincidences. The new results, together with the known decay scheme of 67 Cu , were used to determine absolute β - -decay branching intensities. The present data differ significantly from previously published values. In addition, the half-life of the I π = 1/2 - isomer in 67 Zn was measured as T 1/2 = 9.37(4) μs, in a good agreement with earlier measurements. Lastly, from the analysis of the Fermi–Kurie plots, Q β - ( g.s.) = 560.3 (10) keV was deduced, which differs from the previously measured value of 577(8) keV but is in good agreement with Q β - ( g.s.) = 561.3 (15) keV recommended in the latest Atomic Mass Evaluation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Acoustic scaling of linear and mode-coupled anisotropic flow; implications for precision extraction of the specific shear viscosity

The n th -order linear flow coefficients v n L ( n = 2 , 3 , 4 , 5 ) , and the corresponding nonlinear mode-coupled ( mc ) coefficients v 4 , ( 2 , 2 ) mc , v 5 , ( 2 , 3 ) mc , v 6 , ( 3 , 3 ) mc , and v 6 , ( 2 , 2 , 2 ) mc , are studied for Pb+Pb collisions at s N N = 2.76 TeV. Both sets of coefficients suggest a common acoustic scaling pattern of exponential viscous modulation, with a rate proportional to the square of the harmonic numbers and the mean transverse momenta (respectively), and inversely proportional to the cube root of the charged particle multiplicity [ ( N ch ) 1 / 3 ] , which characterizes the dimensionless size of the systems produced in the collisions. These patterns and their associated scaling parameters offer new stringent constraints for eccentricity-independent estimates of the specific shear viscosity η s ( T ) and the viscous correction to the thermal distribution function for the matter produced in the collisions. They also give crucial constraints for extraction of the initial-state eccentricity spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗