Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system oscillation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Dynamic Oscillation and Motion of Oil‐in‐Water Emulsion Droplets

The interplay of interfacial tensions on droplets results in a range of self‐powered motions that mimic those of living systems and serve as a tunable model to understand their complex non‐equilibrium behavior. Spontaneous shape deformations and oscillations are crucial features observed in nature but difficult to incorporate in synthetic artificial systems. Here, we report sessile oil‐in‐water emulsions that exhibit rapid oscillating behavior. The oscillations depend on the nature and concentration of the surfactant, the chemical composition of the oil, and the wettability of the solid substrate. The rapid changes in the contact angle per oscillation are observed using side‐view optical microscopy. We propose that the changes in the interfacial tension of the oil droplets is due to the partitioning of the surfactant into the oil phase and the movement of self‐emulsified oil out of the parent droplets giving rise to the rhythmic variation in droplet contact‐line. The ability to control and understand droplet oscillation can help model similar oscillations in out‐of‐equilibrium systems in nature and reproduce biomimetic behavior in artificial systems for various applications, such as microfluidic lab‐on‐a‐chip and adaptive materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic Oscillation and Motion of Oil‐in‐Water Emulsion Droplets

Abstract The interplay of interfacial tensions on droplets results in a range of self‐powered motions that mimic those of living systems and serve as a tunable model to understand their complex non‐equilibrium behavior. Spontaneous shape deformations and oscillations are crucial features observed in nature but difficult to incorporate in synthetic artificial systems. Here, we report sessile oil‐in‐water emulsions that exhibit rapid oscillating behavior. The oscillations depend on the nature and concentration of the surfactant, the chemical composition of the oil, and the wettability of the solid substrate. The rapid changes in the contact angle per oscillation are observed using side‐view optical microscopy. We propose that the changes in the interfacial tension of the oil droplets is due to the partitioning of the surfactant into the oil phase and the movement of self‐emulsified oil out of the parent droplets giving rise to the rhythmic variation in droplet contact‐line. The ability to control and understand droplet oscillation can help model similar oscillations in out‐of‐equilibrium systems in nature and reproduce biomimetic behavior in artificial systems for various applications, such as microfluidic lab‐on‐a‐chip and adaptive materials.

Krishna Mani, Sanjana↗

Coherency-Aware Learning Control of Inverter-Dominated Grids: A Distributed Risk-Constrained Approach

Here, this letter investigates the importance of integrating the coherency knowledge for designing controllers to dampen sustained oscillations in wide-area power networks with significant penetration of inverter-interfaced resources. Coherency is a fundamental property of power systems, where time-scale separation in frequency dynamics leads to clustered behavior among generators of different groups. Large-scale penetration of inverter-driven low inertia resources replacing conventional synchronous generators (SGs) can lead to perturbation in the coherent partitioning; hence, integrating such information is of utmost importance for oscillation control designs. We present the coherency-aware design of a distributed output feedback-based reinforcement learning method that additionally incorporates risk constraints to capture the uncertainties related to net-load fluctuations. The use of domain-aware coherency information has produced improved training and oscillation performance than the coherency-agnostic control design, hence proving to be effective in controller design. Finally, we validated the proposed method with numerical experiments on the benchmark IEEE 68-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar PV and BESS Plant-Level Voltage Control and Interactions: Experiments and Analysis

In real world operation, low-frequency oscillations associated with plant-level voltage control of inverter-based resources (IBRs) have been a concern of grid operators. Here, this research aims to demonstrate and analyze the effect of plant-level voltage control on system stability and potential interactions among IBRs. The experiment results of a 13.2-kV system interconnected with two IBRs—a 1-MW battery energy storage system (BESS) and a 430-kW solar photovoltaic (PV) plant—are presented. Both 0.5-Hz and 3-Hz oscillations become visible at certain conditions. The phenomenon is further explained by use of a feedback system consisting of the plant-level droop control and the effect of reactive power or var injection on voltage. The main components of the block diagram are obtained via frequency scan measurements. The analysis offers an understanding of the main contributors and other influencing factors of the 3-Hz and 0.5-Hz modes. It also reveals the role of the volt-var droop gain, the low-pass filter time constant, and the system impedance in stability.

14 SOLAR ENERGY↗

Universal Passive Synchronization Method for Grid-Forming Inverters Without Mode Transition

Power systems are transforming with increasing levels of inverter-based resources (IBRs). This transformation requires critical roles of grid-forming (GFM) inverters replacing synchronous generators for bulk power system stabilization and ancillary services, also allowing flexible power system operation, such as microgrid that is operated by multiple GFM IBRs to achieve system resilience against contingencies. To realize the resilient power systems allowing flexible in-and-out operation of GFM IBRs potentially programmed with different primary controls, a synchronization method universally applicable, i.e., independent of control types, would be beneficial to ease the integration process, but it has not been actively studied. To fill the gap, this paper proposes a universal synchronization method that achieves a passive synchronization to enable a smooth transition in a grid with off-nominal system parameters, i.e., voltage and frequency. The logic proposed requires no modification on the primary control, thus applicable to any type of GFMs with a voltage reference input. To validate the concept, a simulation of an IEEE 13-bus benchmark system modified with 3 GFM inverters is presented. It simulates an inverter-driven black start scenario in which GFM inverters autonomously turn on and connect to the grid under heavy loading, using the synchronization logic. The case study demonstrates that GFM inverters can tune their voltage reference to smoothly synchronize without severe transients, and contribute to a seamless black start of the grid under unbalanced load conditions. Two GFM methods - Droop and dispatchable virtual oscillator control - are used for the demo to validate feasibility and interoperability of the passive synchronization.

black start↗

Bulk Power System Dynamics with Varying Levels of Synchronous Generators and Grid-Forming Power Inverters

Inverters using phase-locked loops for control depend on voltages generated by synchronous machines to operate. This might be problematic if much of the conventional generation fleet is displaced by inverters. To solve this problem, grid-forming control for inverters has been proposed as being capable of autonomously regulating grid voltages and frequency. Presently, the performance of bulk power systems with massive penetration of grid-forming inverters has not been thoroughly studied as to elucidate benefits. Hence, this paper presents inverter models with two grid-forming strategies: virtual oscillator control and droop control. The two models are specifically developed to be used in positive-sequence simulation packages and have been implemented in PSLF. The implementations are used to study the performance of bulk power grids incorporating inverters with gridforming capability. Specifically, simulations are conducted on a modified IEEE 39-bus test system and the microWECC test system with varying levels of synchronous and inverter-based generation. The dynamic performance of the tested systems with gridforming inverters during contingency events is better than cases with only synchronous generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Oscillator for adiabatic computational circuitry

An adiabatic resonator, an adiabatic oscillator, and an adiabatic oscillator system are disclosed. An adiabatic system is one that ideally transfers no heat outside of the system, thereby reducing the required operating power. The adiabatic resonator, which includes a plurality of tank circuits, acts as an energy reservoir, the missing aspect of previously attempted adiabatic computational systems. By using the adiabatic resonator as a feedback element with an amplifier, an adiabatic oscillator is formed. An adiabatic oscillator system is formed with a primary adiabatic oscillator feeding a plurality of secondary adiabatic oscillators. In this manner, the adiabatic oscillator system may be used to generate the multiple clock signals required of adiabatic computational logic elements, such as Split-level Charge Recovery Logic and 2-Level Adiabatic Logic. The adiabatic oscillator system stores enough energy to drive many individual adiabatic computational logic elements, permitting implementation of complex logic circuits.

Brocato, Robert W.↗

Efficacy of vibro-impact energy harvesting absorbers on controlling dynamical systems under vortex-induced vibrations and base excitation

Here this study investigates improving the efficacy of an energy harvesting absorber's ability to control a structure under vortex-induced vibrations, base excitation, and a combination of the two by including mechanical amplitude stoppers. The nonlinear reduced-order model is developed through modifying trilinear spring models to represent the impact forces, a modified van der Pol oscillator to represent the forcing due to the vortex-induced vibrations and using the Euler-Lagrange principle to express the equations of motion. It is seen that a soft stopper stiffness and a 5mm gap performs the most effectively of increasing the power generated from the absorber while still greatly reducing the primary structure's amplitude. By changing the stopper's location towards the middle of the energy harvesting absorber, the large effects of the impact forces are reduced and improves the efficacy of medium and hard stopper stiffnesses to generate near the amount of power the soft stopper does, while greatly improving the control of the primary structure. When the system is under combined loadings, the large oscillations of the synchronization region cause the effective configuration to be that of a 27.5 mm gap with soft stiffnesses. The results shows that medium stiffness stoppers with small gaps generate large aperiodic regions due to the high impact force. When the oscillations are close to the stoppers, the beating phenomenon is observed and is not overpowered by the vibro-impact force.

16 TIDAL AND WAVE POWER↗

Decentralized Distribution System Restoration with Grid-Forming/Following Inverter-Based Resources

The high penetration of distributed energy resources (DERs) in active distribution systems has posed challenges to the centralized distribution system restoration (DSR) strategies in current practice. On the other hand, the advancement in smart inverter technologies enables the bottom-up restoration capability. This paper is motivated to develop a 3-layered hierarchical framework for decentralized DSR, based on the grid-forming (GFM) and grid-following (GFL) grid-edge inverters. The first layer presents the tertiary control, which determines the load pickup schedule and generation dispatch of DERs, using the alternating direction method of the multipliers algorithm. The second layer consists of two control functions: GFM control, which regulates voltage and frequency, establishing a stable grid for GFL inverters to follow; and GFL control, which regulates the real and reactive power. In the third layer, the primary control is proposed to regulate the inverter voltage and current, which is developed based on the virtual oscillator control (VOC). Furthermore, the developed framework is tested in the modified IEEE 13-node test feeder. Two scenarios of grid-connected and islanded operating modes are designed, and simulation results demonstrate the effectiveness of decentralized DSR strategies for controlling grid-edge inverters to enhance the distribution system resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Measurement and Analysis of Frequency and RoCoF for Low-Inertia Power Systems

The frequency measurement and rate of change of frequency (RoCoF) calculations are important for active power, frequency control, and frequency-related protection in power system operations. With the rapid decrease in inertia under modern power systems, however, multiple power variations introduced by variable renewable energy bring large RoCoF and introduce oscillations in frequency measurements. To shed light on this issue, this article proposes a frequency measurement and RoCoF analysis technology, as well as the sensitivity analysis for the real low-inertia power grid. First, a real-world event in an island power grid is analyzed as an example, and an event numerical model is estimated considering four uncertainties, including event RoCoF, oscillation magnitude, oscillation frequency, and underfrequency load-shedding threshold. Then, a sensitivity analysis is performed using the Sobol indices method and quasi-Monte Carlo simulations to identify the dominant uncertainties based on the event model. Here, the dominant uncertainties are compared to provide a guideline for the frequency estimation algorithm selection under different event cases. This algorithm is compared with an enhanced zero-crossing algorithm and gives a 3.41% better RoCoF error rate. Finally, an experiment is conducted using universal grid analyzers to validate the simulation results and the theoretical analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Single-mode squeezed-light generation and tomography with an integrated optical parametric oscillator

Quantum optical technologies promise advances in sensing, computing, and communication. A key resource is squeezed light, where quantum noise is redistributed between optical quadratures. We introduce a monolithic, chip-scale platform that exploits the χ (2) nonlinearity of a thin-film lithium niobate (TFLN) resonator device to efficiently generate squeezed states of light. Our system integrates all essential components—except for the laser and two detectors—on a single chip with an area of one square centimeter, reducing the size, operational complexity, and power consumption associated with conventional setups. Using the balanced homodyne measurement subsystem that we implemented on the same chip, we measure a squeezing of 0.55 decibels and an anti-squeezing of 1.55 decibels. We use 20 milliwatts of input power to generate the parametric oscillator pump field by using second harmonic generation on the same chip. Our work represents a step toward compact and efficient quantum optical systems posed to leverage the rapid advances in integrated nonlinear and quantum photonics.

97 MATHEMATICS AND COMPUTING↗

Model-Agnostic Algorithm for Real-Time Attack Identification in Power Grid using Koopman Modes

Malicious activities on measurements from sensors like Phasor Measurement Units (PMUs) can mislead the control center operator into taking wrong control actions resulting in disruption of operation, financial losses, and equipment damage. In particular, false data attacks initiated during power systems transients caused due to abrupt changes in load and generation can fool the conventional model-based detection methods relying on thresholds comparison to trigger an anomaly. In this paper, we propose a Koopman mode decomposition (KMD) based algorithm to detect and identify false data attacks in real-time. The Koopman modes (KMs) are capable of capturing the nonlinear modes of oscillation in the transient dynamics of the power networks and reveal the spatial embedding of both natural and anomalous modes of oscillations in the sensor measurements. The Koopman-based spatio-temporal nonlinear modal analysis is used to filter out the false data injected by an attacker. The performance of the algorithm is illustrated on the IEEE 68-bus test system using synthetic attack scenarios generated on GridSTAGE, a recently developed multivariate spatio-temporal data generation framework for simulation of adversarial scenarios in cyber-physical power systems.

Nandanoori, Sai Pushpak↗

Real-World Subsynchronous Oscillation Events in Power Grids with High Penetrations of Inverter-Based Resources

This paper presents a survey of real-world sub-synchronous oscillation events associated with inverter-based resources (IBR) over the past decade. The focus is on those oscillations in the subsynchronous frequency range known to be influenced by power grid characteristics, e.g., series compensation or low system strength. A brief overview of the historical events is presented followed by detailed descriptions of a series of events. This paper also examines causation mechanisms and proposes future research directions to meet grid needs worldwide.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchro-Waveform-Based Event Identification Using Multi-Task Time-Frequency Transform Networks

Influenced by the transient dynamics and reduced inertia characteristics of high-penetration renewable energy systems, power system events frequently exhibit distinct characteristics such as high-frequency components including wide-band oscillations and hyper-harmonics. This makes standard systems face challenges including significant latency and reduced accuracy due to limited data resolution. However, current methods face significant limitations, including insufficient pattern capture ability, low noise immunity, limited feature learning, and restricted localization capabilities, thereby hindering real-time performance. To tackle this issue, this paper proposed a novel synchro-waveform-based event identification approach via a Multi-task Time-frequency Transform Network (MTTNet). Initially, a Time-frequency Transform Block (TTB) is developed to extract both local and global information. The TTB leverages both Fourier and S-transforms to derive comprehensive time-frequency information from synchro-waveforms. Subsequently, a multi-task learning strategy is employed to identify the type and distinguish localization of events. Integrating the TTB and multi-task learning, the MTTNet is designed for synchro-waveform-based event identification, incorporating an adaptive weighting strategy and simplified computation for the S-transform. Two different datasets, comprising simulated and actual synchro-waveforms, are collected from the IEEE 123 bus system and a real-world high-penetration renewable energy system using a universal grid analyzer. Extensive experiments on various conditions are carried out. In conclusion, results demonstrated that the MTTNet consistently surpasses both basic and advanced baselines, with maximum improvements of 13.24% and 9.86%, respectively, while reducing the calculation burden by 15-19 times to achieve real-time event identification.

Event identification↗

A Comparison of Power Take-Off Architectures for Wave-Powered Reverse Osmosis Desalination of Seawater with Co-Production of Electricity

Several power take-off (PTO) architectures for wave-powered reverse osmosis (RO) desalination of seawater are introduced and compared based on the annual average freshwater production and the size of the components, which strongly relate to the costs of the system. The set of architectures compared includes a novel series-type PTO architecture not previously considered. These seawater hydraulic PTO architectures are composed of a WEC-driven pump, an RO module, an intake charge pump driven by an electric motor, and a hydraulic motor driving an electric generator for electric power production. This study is performed using an efficient two-way coupled steady-state model for the average performance of the system in a given sea state, including freshwater permeate production, electric power production, and electric power consumption. A multi-objective design problem is formulated for the purposes of this comparative study, with the objectives of maximizing annual freshwater production, minimizing the displacement of the WEC-driven pump, and minimizing the installed RO membrane area. This establishes a framework for comparison in the absence of a mature techno-economic model. The requirement that the system produces enough electric power to meet its consumption is applied as a constraint on the operation of the system. The oscillating wave surge converter Oyster 1 is assumed as the WEC. Weights on performance of the system in a given sea state are based on historical data from Humboldt Bay, CA. This study finds that (1) architectures in a series configuration allow for a reduction in the WEC-driven pump size of 59–92% compared to prior work, (2) varying the displacement of the WEC-driven pump between sea conditions does not provide any significant advantage in performance, and (3) varying the active RO membrane area between sea condition offers improvements between 7% and 41% in each design objective.

Energy & Fuels↗

High-Temperature Wireless Sensor Platform Powered by Energy Scavenging

This paper reports on the development of key components required for a self-powered oscillator unit designed to wirelessly transmit its signal under full insertion in high-temperature (HT) harsh-environments (HE), such as those present in power plants and industrial settings (metallurgic, oil extraction, molding, and aerospace). The oscillator employed a silicon carbide (SiC) power transistor and HT passive components on a screen-printed alumina circuit board capable of operation beyond 300 °C. The HT oscillator circuit was powered solely by in-situ energy scavenging thermoelectric generator (TEG) modules using passive cooling, eliminating the need for an external power supply or active cooling. In addition, a silicon-based external booster circuit was used to achieve the required TEG voltage regulation to test the TEG-powered HT oscillator circuit. The TEG-powered oscillator circuit was tested inside a non-metallic furnace from room temperature to over 300 °C for transmission of a wireless signal, which was detected outside the furnace at 11 ft (3.4 m). Such a wireless transmitting system powered only by in-situ TEGs, with no requirement for external power or active cooling, is very attractive for flexible, mobile stand-alone control and sensor units targeted for operation in HT HE conditions found in power plants and industrial settings.

20 FOSSIL-FUELED POWER PLANTS↗

Improved Control Strategy of Grid Interface for EV High-Power Dynamic Wireless Charging

This paper proposes a control strategy for the grid interface converter in high-power dynamic wireless charging system (DWCS) to address two issues on distribution network integration. Due to the unique pulsating load profile of DWCS, load transient response capability is critical for the grid interface to maintain the dc-bus voltage stable. Besides, the inherent unbalanced situation of distribution network would lead to 2nd-order oscillations on the dc-bus voltage, which would further affect the stable operation of the entire system. In this paper, the DWCS model is developed, and the relationship between the dc-bus voltage and the input/output power is analyzed. Based on the developed model, a control strategy based on direct power control is presented. Both simulation results and hardware-in-the-loop (HIL) results demonstrate that the proposed control strategy not only improves load transient response capability, but also eliminates the 2nd-order oscillations on the dc-bus voltage under imbalanced distribution network conditions.

Zeng, Rong↗

Multi-millijoule hollow-core fiber compression of short-wave infrared pulses to a single cycle

Approaches for efficient pulse compression can enable dramatic increases in the available peak power, as well as enable the generation of isolated attosecond X-ray pulses. Achieving high compression ratios for longer wavelength drivers has, however, been challenging. We present the compression of few-cycle 2.1 µm central wavelength short-wave infrared laser pulses to 6.9 fs with 2.35 mJ pulse energy at a 10 kHz repetition rate. Electric field resolved measurements reveal a single cycle light field oscillation. With a carrier-envelope-phase stability of 131 mrad and average power fluctuations below 1 %, the system constitutes an excellent light source for strong-field experiments and attosecond physics.

Blöchl, Johannes [Ludwig Maximilian Univ. of Munic↗