Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power gas simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Radio AGN in nearby dwarf galaxies: the important role of AGN in dwarf galaxy evolution

ABSTRACT We combine deep optical and radio data, from the Hyper Suprime-Cam and the Low-Frequency Array (LOFAR), respectively, to study 78 radio active galactic nuclei (AGN) in nearby (z < 0.5) dwarf galaxies. Comparison to a control sample, matched in stellar mass and redshift, indicates that the AGN and controls reside in similar environments, show similar star formation rates (which trace gas availability) and exhibit a comparable incidence of tidal features (which indicate recent interactions). We explore the AGN properties by combining the predicted gas conditions in dwarfs from a cosmological hydrodynamical simulation with a Monte Carlo suite of simulated radio sources, based on a semi-analytical model for radio-galaxy evolution. In the subset of LOFAR-detectable simulated sources, which have a similar distribution of radio luminosities as our observed AGN, the median jet powers, ages, and accretion rates are ∼1035 W, ∼5 Myr, and ∼10−3.4 M⊙ yr−1, respectively. The median mechanical energy output of these sources is ∼100 times larger than the median binding energy expected in dwarf gas reservoirs, making AGN feedback plausible. Since special circumstances (in terms of environment, gas availability, and interactions) are not necessary for the presence of AGN, and the central gas masses are predicted to be an order of magnitude larger than that required to fuel the AGN, AGN triggering in dwarfs is likely to be stochastic and a common phenomenon. Together with the plausibility of energetic feedback, this suggests that AGN could be important drivers of dwarf galaxy evolution, as is the case in massive galaxies.

Davis, F. (ORCID:0000000285224980)↗

Numerical simulation of an atmospheric pressure plasma jet with coaxial shielding gas

A two-dimensional ( r, z ) numerical simulation of the discharge characteristics of an atmospheric pressure plasma jet (APPJ), with coaxial shielding gas, was performed. The helium working gas flowed in a central capillary tube, engulfing a needle electrode powered by 13.7 MHz radio frequency sinusoidal voltage. The N 2 shielding gas flowed in the annular space of a coaxial tube. These gases emerged, in laminar flow, in a 78%N 2 -21%O 2 -1%Ar dry air ambient. The characteristics of the APPJ with shielding gas were compared to those of the APPJ without shielding gas. The nitrogen shielding gas hindered the diffusion of oxygen and argon from the ambient air into the helium jet. With the shielding gas present, more nitrogen penetrated into the helium core, causing a shorter plasma ‘plume’. The flow rates of the working and shielding gas, critically affected the gas temperature, and in turn the discharge characteristics. For a He flow of 2 standard liters per minute (slm), switching on the nitrogen shielding gas flow (at 4.5 slm) reduced the on-axis O 2 and Ar mole fractions from 3.9 × 10 - 4 to 6.8 × 10 - 5 and from 1.9 × 10 - 5 to 3.3 × 10 - 6 , respectively, at an axial distance of 3 mm downstream of the nozzle. The radial profiles of the mole fractions of the ambient gases were monotonically and strongly decreasing towards the system axis, for short axial distances from the nozzle (~1 mm), but became progressively flatter at longer distances from the nozzle (3 mm and 5 mm). Simulation predictions captured the salient features of experimental data of ambient species mole fractions in the plasma jet, and the 706 nm optical emission intensity profiles of the He 3 3 S excited state.

Physics↗

Pulsed power to control growth of silicon nanoparticles in low temperature flowing plasmas

Low-temperature plasmas have seen increasing use for synthesizing high-quality, mono-disperse nanoparticles (NPs). Recent work has highlighted that an important process in NP growth in plasmas is particle trapping—small, negatively charged nanoparticles become trapped by the positive electrostatic potential in the plasma, even if only momentarily charged. In this article, results are discussed from a computational investigation into how pulsing the power applied to an inductively coupled plasma (ICP) reactor may be used for controlling the size of NPs synthesized in the plasma. The model system is an ICP at 1 Torr to grow silicon NPs from an Ar/SiH 4 gas mixture. This system was simulated using a two-dimensional plasma hydrodynamics model coupled to a three-dimensional kinetic NP growth and trajectory tracking model. The effects of pulse frequency and pulse duty cycle are discussed. We identified separate regimes of pulsing where particles become trapped for one pulsed cycle, a few cycles, and many cycles—each having noticeable effects on particle size distributions. For the same average power, pulsing can produce a stronger trapping potential for particles when compared to continuous wave power, potentially increasing particle mono-dispersity. Pulsing may also offer a larger degree of control over particle size for the same average power. Experimental confirmation of predicted trends is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hybrid Solar Thermal Energy System for District Heating Application

Solar district heating (SDH) systems can be good alternatives to conventional systems when they are optimized with hybrid configurations and thermal energy storage (TES). In this scope, a hybrid renewable thermal energy system (RTES) model has been built combining flat plate collector (FPC) solar system with parabolic trough collector (PTC) system via a heat exchanger and coupled with TES. To undertake the hybridization of the system, System Advisor Model (SAM) software was modified, which allowed control over configurations and more accurate modelling of heat transfer between the collectors. The model is first compared to an existing hybrid solar district heating systems (DHS) system in Taars, Denmark. The results showed a good correlation with an overestimation of only 6.4% compared to most recent heat output. Then the same system configuration was modeled in different geographic locations to investigate the impact of changes in direct normal irradiance (DNI) to the heat sink thermal output of the hybrid system. The results showed that the annual net thermal power output in California, USA can be three times more than the annual net thermal power output in Taars, Denmark. Finally, multiple hybrid configurations with varying solar field sizes were simulated based on the heat demand of two different university campuses DHS. The results showed that, retrofit applications of this hybrid DHS system coupled with TES could reduce the natural gas consumption of the existing systems between 25% and 41%. The use of hybrid RTES highlighted in this paper can be extended to many more opportunities.

district heating↗

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power balance and divertor asymmetries in the Super-X divertors of MAST-U using SOLPS-ITER

Spherical tokamaks (STs) present unique challenges and opportunities in the area of particle and power exhaust, intensified due to their more compact sizes. Substantial efforts are underway in STs to determine the limits in dissipative operational regimes and advanced divertor solutions, including at MAST-U which provides access to the Super-X divertor configuration. Power balance, and upper/lower divertor asymmetries have been studied using SOLPS-ITER simulations of the MAST-U Super-X divertor. A set of simulations with experimentally inferred transport coefficients with E x B and diamagnetic drifts activated, consisting of density and power scans, and high field side vs low field side gas puff locations, have been used for code experimentation to uncover trends beyond the current experimental parameter space. The upper biased asymmetry (U:L > 1) of the ratio of the peaks of the plasma energy flux densities at the outer targets increases with heating power and decreases with gas puff strength, going from symmetric to up to a factor of 15. The upper target electron temperature has been found to be a good ordering quantity for the magnitude of this asymmetry for all heating powers, gas puff strength, and gas puff locations. The lower divertor biased asymmetry (U:L < 1) of the radiation patterns processed through SOLPS-based bolometry synthetic diagnostics is in qualitative agreement with resistive bolometry experimental results, and it is in quantitative agreement with the trend of the total volume radiation within the divertors of SOLPS. However, radiation measurements alone are not sufficient to infer the magnitude of the asymmetry of the peaks of the power loads at the targets.

MAST-U↗

Atacama Cosmology Telescope: Modeling the gas thermodynamics in BOSS CMASS galaxies from kinematic and thermal Sunyaev-Zel’dovich measurements

The thermal and kinematic Sunyaev-Zel'dovich effects (tSZ, kSZ) probe the thermodynamic properties of the circumgalactic and intracluster medium (CGM and ICM) of galaxies, groups, and clusters, since they are proportional, respectively, to the integrated electron pressure and momentum along the line-of-sight. We present constraints on the gas thermodynamics of CMASS galaxies in the Baryon Oscillation Spectroscopic Survey (BOSS) using new measurements of the kSZ and tSZ signals obtained in a companion paper. Combining kSZ and tSZ measurements, we measure within our model the amplitude of energy injection $\epsilon M_\star c^2$, where $M_\star$ is the stellar mass, to be $\epsilon=(40\pm9)\times10^{-6}$, and the amplitude of the non-thermal pressure profile to be $\alpha_{\rm Nth}<0.2$ (2$\sigma$), indicating that less than 20% of the total pressure within the virial radius is due to a non-thermal component. We estimate the effects of including baryons in the modeling of weak-lensing galaxy cross-correlation measurements using the best fit density profile from the kSZ measurement. Our estimate reduces the difference between the original theoretical model and the weak-lensing galaxy cross-correlation measurements in arXiv:1611.08606 by half, but does not fully reconcile it. Comparing the kSZ and tSZ measurements to cosmological simulations, we find that they under predict the CGM pressure and to a lesser extent the CGM density at larger radii. This suggests that the energy injected via feedback models in the simulations that we compared against does not sufficiently heat the gas at these radii. We do not find significant disagreement at smaller radii. These measurements provide novel tests of current and future simulations. Here, this work demonstrates the power of joint, high signal-to-noise kSZ and tSZ observations, upon which future cross-correlation studies will improve.

79 ASTRONOMY AND ASTROPHYSICS↗

A Machine Learning-based Reliability Evaluation Model for Integrated Power-Gas Systems

This article proposes a hybrid machine learning method for the reliability evaluation of integrated power-gas systems (IPGS) under the uncertain component failure probability distributions. The Random Forest (RF) method is designed to select important features to solve the insufficient quantity of data and the curse of dimensionality problems. The Extreme Gradient Boosting (XGBoost) regression algorithm is developed to quantify the relationship between the uncertain parameters and reliability metrics. Moreover, a ten-fold cross-validation method is employed to further improve the accuracy of the regression model. Simulation results on three test systems show that the proposed method can achieve high accuracy for the reliability evaluation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extragalactic CO emission lines in the CMB experiments: A forgotten signal and a foreground

High resolution cosmic microwave background (CMB) experiments have allowed us to precisely measure the CMB temperature power spectrum down to very small scales (multipole ℓ ~ 3000). Such measurements at multiple frequencies enable separating the power spectrum of the primary CMB anisotropies with the power spectrum of other signals like CMB lensing, thermal and kinematic Sunyaev-Zel’dovich effects (tSZ and kSZ), and cosmic infrared background (CIB). Here, in this paper, we explore another signal of interest at these frequencies that should be present in the CMB maps: extragalactic CO molecular rotational line emissions, which are the most widely used tracers of molecular gas in the line intensity mapping experiments. Using the SIDES simulations adopted for top hat bandpasses at 150 and 220 GHz, we show that the cross-correlation of the CIB with CO lines has a contribution similar to the CIB-tSZ correlation and the kSZ power, thereby contributing a non-negligible amount to the total power at these scales. This signal, therefore, may significantly impact the recently reported ≥3σ detection of the kSZ power spectrum from the South Pole Telescope collaboration, as the contribution of the CO lines is not considered in such analyses. Our results also provide a new way of measuring the CO power spectrum in cross-correlation with the CIB. Finally, these results show that the CO emissions present in the CMB maps will have to be accounted for in all the CMB auto-power spectrum and cross-correlation studies involving a large-scale structure tracer.

79 ASTRONOMY AND ASTROPHYSICS↗

Feasibility Analysis of Converter-Interfaced Combined Heat and Power System

As a promising new design concept, the converter-interfaced combined heat and power (CHP) system is coupled to the bulk grid through a rectifier and a grid-ready tied inverter. Compared to the traditional directly-coupled CHP system, it removes the requirement for oversizing the CHP generator, limits the short-circuit contribution of the generator and simplifies the grid integration process of CHP system. This paper evaluates the economic benefits of this concept by calculating the annualized Return-on-Investment (ROI) and comparing it to the directly-coupled system. The economic analysis includes timeseries simulations to compute energy transactions with the bulk grid as well as sizing the equipment to calculate the capital and operational costs. Obtained results indicate that in majority of user cases evaluated, the converter-interfaced CHP systems can provide better ROI than directly-coupled systems. Given the additional technical benefits provided by inverter-based distributed energy resources (DERs), the proposed concept is proved to be technically viable and economically feasible.

03 NATURAL GAS↗

Self-consistent integrated modeling of combined hybrid discharge-laser produced plasma devices for extreme ultraviolet metrology

Discharge- and laser-produced plasma (DLPP) devices are being used as light sources for extreme ultraviolet (EUV) generation. A key challenge for both, DPP and LPP, is achieving sufficient brightness to support the throughput requirements of nanometrology tools. To simulate the environment of a hybrid DLPP device and optimize the EUV output, we have developed an integrated HEIGHTS-DLPP computer simulation package. The package integrates simulation of two evolving plasmas (DPP and LPP) and includes modeling of a set of integrated self-consistent processes: external power source and plasma energy balance, plasma resistive magnetohydrodynamics, plasma heat conduction, detailed radiation transport (RT), and laser absorption and refraction. We simulated and optimized DLPP devices using Xe gas as a target material. We synchronized the external circuit parameters, chamber gas parameters, and laser beam temporal and spatial profiles to achieve maximum EUV output. The full 3D Monte Carlo scheme was integrated for detailed RT and EUV output calculations in Xe using more than 3600 spectral groups. The modeling results are in good agreement with Julich Forschungszentrum experimental data. Theoretical models, developed and integrated into the HEIGHTS package, showed wide capabilities and flexibility. In conclusion, the models and package can be used for optimization of the experimental parameters and settings, investigation of DLPP devices with complex design, analyzing the impact of integrated spatial effects and working timeline arrangement on the final EUV output, and EUV source size, shape, and angular distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Weak lensing combined with the kinetic Sunyaev–Zel’dovich effect: a study of baryonic feedback

ABSTRACT Extracting precise cosmology from weak lensing surveys requires modelling the non-linear matter power spectrum, which is suppressed at small scales due to baryonic feedback processes. However, hydrodynamical galaxy formation simulations make widely varying predictions for the amplitude and extent of this effect. We use measurements of Dark Energy Survey Year 3 weak lensing (WL) and Atacama Cosmology Telescope DR5 kinematic Sunyaev–Zel’dovich (kSZ) to jointly constrain cosmological and astrophysical baryonic feedback parameters using a flexible analytical model, ‘baryonification’. First, using WL only, we compare the $S_8$ constraints using baryonification to a simulation-calibrated halo model, a simulation-based emulator model, and the approach of discarding WL measurements on small angular scales. We find that model flexibility can shift the value of $S_8$ and degrade the uncertainty. The kSZ provides additional constraints on the astrophysical parameters, with the joint WL + kSZ analysis constraining $S_8=0.823^{+0.019}_{-0.020}$. We measure the suppression of the non-linear matter power spectrum using WL + kSZ and constrain a mean feedback scenario that is more extreme than the predictions from most hydrodynamical simulations. We constrain the baryon fractions and the gas mass fractions and find them to be generally lower than inferred from X-ray observations and simulation predictions. We conclude that the WL + kSZ measurements provide a new and complementary benchmark for building a coherent picture of the impact of gas around galaxies across observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Missing baryons recovered: A measurement of the gas fraction in galaxies and groups with the kinematic Sunyaev-Zel’dovich effect and CMB lensing

We present new constraints on the halo masses and matter density profiles of DESI galaxy groups by cross-correlating samples of luminous red galaxies (LRGs) and bright galaxy survey (BGS) galaxies with the publicly available CMB lensing convergence map from ACT DR6. This provides an independent, lensing-based calibration of halo masses, complementary to methods relying on clustering or dynamics. We derive constraints on the mean halo mass for three DESI-selected samples, finding log⁡(𝑀 halo /(𝑀 ⊙ /ℎ)) ≈ 13.18, 13.03 and 13.02 for the main LRG, extended LRG, and BGS samples, respectively. Using a halo model approach, we also compare the projected galaxy-matter density profiles with previously reported gas profiles inferred from measurements of the kinematic Sunyaev-Zel’dovich (kSZ) effect. This work addresses one of the key uncertainties in interpreting kSZ signals—the unknown host halo mass distribution—by providing an independent and consistent mass calibration. The agreement between the gas and total mass profiles at large aperture suggests that sufficiently far from the group center (2–3 virial radii), we recover all the baryons, offering a resolution to the missing baryon problem. We further study the cumulative gas fractions for all galaxies as well as for the most massive galaxy groups in the sample [log⁡(𝑀 halo /(𝑀 ⊙ /ℎ)) ≈ 13.5], finding values that are physically sensible and in agreement with previous findings using kSZ and x-ray data: compared to the TNG300 simulation, the observed gas fractions are systematically lower at fixed radius by ≳ 4⁢𝜎, providing compelling, independent evidence for stronger baryonic feedback in the real Universe. These findings highlight the power of combining CMB lensing with galaxy surveys to probe the interplay between baryons and dark matter in group-sized halos.

Hadzhiyska, Boryana [Lawrence Berkeley National La↗

Computational Evaluation of Thermal Response of Open-Cell Foam With Circular Pore (Computional Evaluation of Thermal Response of Open-Cell Foam with Circular Pore)

The evaluation of effective material properties in heterogeneous materials (e.g., composites or multicomponent structures) critically relevant to a wide spectrum of applications, including nuclear power, electronic packaging, flame retardants, hypersonics, and gas turbine power. The work described in this paper is centered around the numerical assessment of the thermal behavior of porous materials obtained from finite element thermal modeling and simulation. Here, two-dimensional, steady state analyses were performed on unit cells with centered, circular pores using a second order accurate Galerkin finite element method (FEM). The effective thermal conductivities of the porous systems were examined, encompassing a range of porosities from 4.9% to 60.1%. The geometries of the models were generated based on ordered circular pores for each modeled porosity level. The system response quantity (SRQ) under investigation was the dimensionless effective thermal conductivity across the unit cell. The dimensionless effective thermal conductivity was compared across all simulated cases, producing a trend between porosity and effective thermal conductivity. In the presented investigation, the method of manufactured solutions (MMS) was used to perform code verification, and the grid convergence index (GCI) was employed to estimate discretization uncertainty as solution verification. Code verification concluded an approximately second order accurate Galerkin FEM solver. It was found that the introduction of porosity to the unit cell material structure reduces effective thermal conductivity, as anticipated. Numerical results obtained in this study are compared to an analytical solution and to a sample of empirical data.

36 MATERIALS SCIENCE↗

Oscillatory Spreading and Inertia in Power Grids

The increase in variable renewable generators (VRGs) in power systems has altered the dynamics from a historical experience. VRGs introduce new sources of power oscillations, and the stabilizing response provided by synchronous generators (SGs, e.g., natural gas, coal, etc.), which help avoid some power fluctuations, will lessen as VRGs replace SGs. These changes have led to the need for new methods and metrics to quickly assess the likely oscillatory behavior for a particular network without performing computationally expensive simulations. This work studies the impact of a critical dynamical parameter - the inertia value - on the rest of a power system's oscillatory response to representative VRG perturbations. We use a known localization metric in a novel way to quantify the number of nodes responding to a perturbation and the magnitude of those responses. This metric allows us to relate the spread and severity of a system's power oscillations with inertia. We find that as inertia increases, the system response to node perturbations transitions from localized (only a few close nodes respond) to delocalized (many nodes across the network respond). We introduce a heuristic computed from the network Laplacian to relate this oscillatory transition to the network structure. We show that our heuristic accurately describes the spread of oscillations for a realistic power-system test case. Using a heuristic to determine the likely oscillatory behavior of a system given a set of parameters has wide applicability in power systems, and it could decrease the computational workload of planning and operation.

dynamical systems↗

Geothermal Deep Direct Use for Turbine Inlet Cooling in East Texas

The National Renewable Energy Laboratory (NREL), the Southern Methodist University Geothermal Laboratory (SMU), Eastman Chemical (Longview, TX), and TAS (Houston, TX) evaluated the feasibility of using geothermal heat to improve the performance of a natural-gas power plant in East Texas. The area of interest is the Eastman Chemical plant in Longview, Texas, which is on the northwestern margin of a geologic region known as the Sabine Uplift. The feasibility study focused on determining the potential for accessing a subsurface hot-water geothermal resource within a 10-km radius of the site to provide thermal energy for absorption chillers. Wells within a 20-km radius are included for broader geological comparison to determine the heat flow, temperature-at-depth, field porosity and permeability. The lithologies of most interest are the Lower Cretaceous Trinity Group and Upper Jurassic Cotton Valley Group. The deeper Cotton Valley formations are hotter (averaging 117 to 130°C), yet permeability and porosity are low. The shallower Trinity Group contains more variability in permeability and porosity and lower temperatures averaging about 98 to 117°C. The shallower formations are considered despite the lower temperature because of increased ability to produce larger volumes of water and extract enough heat before reinjection. The complete SMU analysis is available in the National Geothermal Data System (NGDS). Tapping such deep geothermal sources for direct heating (as opposed to power generation) is known as geothermal deep direct use (DDU). Geothermal DDU has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for what are typically small-scale, variable-demand projects. This project examines the feasibility of geothermal energy integration in a natural-gas combined cycle power station in East Texas. The DDU resource is tapped to drive absorption chillers (24/7) for production of chilled water at 5-10°C (41-50°F). This chilled water is stored until needed, which allows for continuous operation with a relatively small-capacity geothermal/absorption chiller system. When conditions are favorable, the chilled water is dispatched to cool the air entering the compressor stage of a gas combustion turbine. This process, known as turbine inlet cooling (TIC), boosts power production during periods of high temperature and high-power demand. Such systems can enhance grid reliability and reduce the cost for peak-demand power. A simulation model of the power plant was developed in IPSEpro software and validated against operational data from the plant. This model allowed the team to estimate the additional power that could be produced by applying TIC under different operating and ambient conditions. Absorption chiller performance was estimated from vendor sources to determine the production rate of chilled water from the geothermal resource. Geothermal drilling and development costs were estimated using NREL's GEOPHIRES 2.0. The expected lower drilling costs in this region led to an estimated cost of geothermal heat of about $4/MMBtu (1.4 cents/kWh t ). The estimated cost for the absorption chillers and TIC hardware were obtained from literature sources and project partners. Hourly data were obtained for weather, natural gas and electricity prices, and plant operating state for 2017, which served as a representative year. NREL estimated the capital cost, operating cost, and additional electricity production and revenue for different combinations of geothermal capacity, chiller capacity, and water storage-tank size. The analysis drove toward smaller geothermal and chiller systems to reduce equipment cost. A relatively low-cost water storage tank accumulated the near-continuous chilled water output for later use when TIC was most valued.

15 GEOTHERMAL ENERGY↗

Combined Cycle Integrated Thermal Energy Storage “CiTES” (Final Scientific/Technical Report)

The Phase I of this project confirmed the technical feasibility of a Combined Cycle integrated Thermal Energy Storage “CiTES” system, calculated the key performance parameters like power efficiency and costs, and proved its commercial value with full-year simulations for several US electricity markets with high degree of variable renewable generation and volatile hourly electricity prices. The core element of this project is the Electro Thermal Energy Storage (ETES) technology from Siemens Gamesa Renewable Energy GmbH, using thermally stable and inexpensive volcanic rocks as storage material and air as heat transfer medium. This technology is backed by more than 10 years of experience and a 440MMBTU (130MWh-th) pilot plant in Hamburg, Germany, which is in operation since 2019. The integration of this thermal storage in an existing combined cycle power plant (CCPP) is typical power plant technology without any major technology risks. It allows the storage of inexpensive renewable energy during times of surplus renewable generation and the discharge of this energy in times of high energy demand when the fossil plant is in operation. This supplements the fossil power generation with CO2-emission-free energy. The secondary effect of the CiTES system is that a small part of the stored thermal energy is used to keep the heat recovery steam generator (HRSG) and steam turbine (ST) of the combined cycle power plant in hot and ready-to-start condition. This enables the plant to start rapidly when fossil generation is required to satisfy demand as soon variable generation drops off in the evenings or during cloud cover and calm wind periods. Without pre-warming of the HRSG and ST, the CCPP would need several hours for a cold or warm start, burn a lot of gas and release high NOx emissions during start and wouldn’t be able to use the short times of high energy prices in an efficient or economical manner. The economic parameters of CiTES were determined by a full year “8760” simulation using a data set calculation for each of the hours of the year, and historical electricity and gas prices. For consistency, the simulations were focused on the pre-COVID year 2019. The financially most attractive markets were in the Energy Reliability Council of Texas (ERCOT) region, which allowed substantial value generation with arbitrage (charge with cheap energy during renewable surplus times and discharge when energy is needed and expensive). The improvement of flexibility with the CiTES system by pre-heating and warm-keeping of the CCPP allowed for additional power generation during short time periods when demand is high but renewable generation is down; when the hourly energy prices are highest in these markets. The simulations are based on 2019 data, when ERCOT had 27GW of installed photovoltaic (PV) and wind generation. They showed that the created revenue with the prototypically sized CiTES system of 1,000MMBTU (300MWh-th) falls a little bit short of what is expected from a commercially viable investment. The system has optimization opportunities for cost reduction and increased effectiveness which will be realized during a potential Phase II Pre-FEED study following this project. Furthermore, it is safe to assume that a lot of renewable generation capacity will be added all over the US in the coming years. As an example, ERCOT is predicting to more than double its renewable generation from 27GW in 2019 to a forecasted 63GW in 2023. This will increase the amount of renewable overproduction exponentially. This rapid increase of local overproduction and the need to curtail renewable generation is well documented by the California ISO (www.CAISO.com / managing oversupply). However, the simulations also revealed a weakness in the structure of the electricity markets in the US. More specifically, when electricity prices are very low and approaching negative levels, the owners of Variable Renewable Energy (VRE) will curtail a part of their facility to stabilize the price by reducing supply. This results in a situation in which storage facilities, which are integrated in existing fossil assets and don’t have the behind-the-meter benefit of a VRE, won’t be able to purchase low cost – otherwise curtailed – renewable energy off the grid. A special tariff, which motivates VRE owners to sell otherwise curtailed renewable energy to storage facilities (Hydrogen, thermal, pumped hydro, etc.) can solve this issue. The implementation of such a regulating tariff by Independent System Operators, thus avoiding renewable curtailment, is a pre condition for successful commercialization for renewable energy storage technologies. With this advancement of design and technology and improvements in the market environment, it can be expected that the Combined Cycle integrated Thermal Energy Storage proves itself as an important innovation to keep highly efficient, natural gas-based power generation economically successful and relevant for the power industry in the United States of America.

Wolf, Thorsten↗

What Sets the Star Formation Rate of Molecular Clouds? The Density Distribution as a Fingerprint of Compression and Expansion Rates

We use a suite of 3D simulations of star-forming molecular clouds, with and without stellar feedback, magnetic fields, and driven turbulence, to study the compression and expansion rates of the gas as functions of density. We show that, around the mean density, supersonic turbulence promotes rough equilibrium between the amounts of compressing and expanding gas, consistent with continuous gas cycling between high- and low-density states. We find that the inclusion of protostellar jets produces rapidly expanding and compressing low-density gas. We find that the gas mass flux peaks at the transition between the lognormal and power-law forms of the density probability distribution function (PDF). This is consistent with the transition density tracking the post-shock density, which promotes an enhancement of mass at this density (i.e., shock compression and filament formation). At high densities, the gas dynamics are dominated by self-gravity: the compression rate in all of our runs matches the rate of the run with only gravity, suggesting that processes other than self-gravity have little effect at these densities. The net gas mass flux becomes constant at a density below the sink formation threshold, where it equals the star formation rate. The density at which the net gas mass flux equals the star formation rate is one order of magnitude lower than our sink threshold density, corresponds to the formation of the second power-law tail in the density PDF, and sets the overall star formation rates of these simulations.

79 ASTRONOMY AND ASTROPHYSICS↗