Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power electronics cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Enhanced thermoelectric performance of SnSe by controlled vacancy population

Abstract The thermoelectric performance of SnSe strongly depends on its low-energy electron band structure that provides high density of states in a narrow energy window due to the multi-valley valence band maximum (VBM). Angle-resolved photoemission spectroscopy measurements, in conjunction with first-principles calculations, reveal that the binding energy of the VBM of SnSe is tuned by the population of Sn vacancy, which is determined by the cooling rate during the sample growth. The VBM shift follows precisely the behavior of the thermoelectric power factor, while the effective mass is barely modified upon changing the population of Sn vacancies. These findings indicate that the low-energy electron band structure is closely correlated with the high thermoelectric performance of hole-doped SnSe, providing a viable route toward engineering the intrinsic defect-induced thermoelectric performance via the sample growth condition without an additional ex-situ process. Graphical Abstract

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Overview on Current Activities of Conduction-Cooled SRF Accelerators and their Applications

When Nb3Sn was reintroduced to the SRF community as an alternative to pure niobium, one key motivation has been to reduce the cryogenic requirements of new and existing accelerators by shifting from 2 K to 4 K operation. Meanwhile, a variety of implementations beyond research machines are being explored. The combination of Nb3Sn with conventional cryocoolers, enabling cryogen-free operation, has paved the way for the development of compact, standalone systems suitable for applications far beyond research, such as enhancing the durability of synthetics via crosslinking or sterilizing food and medical equipment, as well as environmental cleanup when it comes to decontaminating liquid and solid waste material. So, while fundamental R&D continues to refine Nb3Sn resonators, exploring improvements such as replacing the niobium substrate with copper, parallel research efforts are investigating how the increased beam power provided by SRF could expand the commercial use of electron beams. This presentation aims to deliver a comprehensive overview of ongoing research efforts to harness the benefits of SRF through Nb3Sn and conduction cooling.

Vennekate, John [Thomas Jefferson National Acceler↗

Polarized positrons at Ce\(^+\)BAF

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab [1]. This concept is based on positron beam generation by a high current polarized electron beam (1 mA, 120 MeV, >85% polarization) irradiating a 4 mm thick rotating water-cooled tungsten target or liquid metal target. The update on the development of the Ce+BAF injector concept including the polarized electron source, the development of high power targets, simulations of positron capture, the design of the transport line from the positron injector to the CEBAF North Linac and the planned experiment to measure the upper limits of transverse and longitudinal emittances accepted by the 12 GeV CEBAF optics are presented. [1] J. Grames et al., "Positron beams at Ce+BAF", in Proc. 14th Int. Particle Accelerator Conf. (IPAC’23), Venice, Italy, MOPL152, pp. 896–899 (2023). doi:10.18429/JACoW-IPAC2023-MOPL152

Ushakov, Andriy↗

Combining molecular beam epitaxy and low-energy electron microscopy with in situ magnetic susceptibility measurements within an integrated ultrahigh vacuum system

Quantum two-dimensional materials, including ultrathin superconducting films, are of great current research interest. These films are typically fabricated under ultra-high vacuum (UHV) conditions and are sensitive to the environment—prone to oxidation and contamination when exposed to the atmosphere. This hampers the study of their intrinsic properties by standard ex situ techniques. Here, we present a variable-temperature mutual inductance probe system integrated under UHV with molecular beam epitaxy (MBE) synthesis and low-energy electron microscopy, enabling nondestructive in situ characterization of superconducting thin films. The system employs a reflection-type configuration and reaches a low temperature (∼4 K) using a high-cooling-power, vibration-isolated cryocooler. In conclusion, we demonstrate the system performance by measuring the superconducting critical temperature in a copper-oxide thin film.

2D materials↗

The Synchrotron Low-energy Spectrum Arising from the Cooling of Electrons in Gamma-Ray Bursts

This work is a continuation of a previous effort (Panaitescu) to study the cooling of relativistic electrons through radiation (synchrotron and self-Compton) emission and adiabatic losses, with application to the spectra and light curves of the synchrotron gamma-ray burst (GRB) produced by such cooling electrons. Here, we derive the low-energy slope β LE of a GRB pulse-integrated spectrum and quantify the implications of the measured distribution of β LE . Radiative processes that produce soft integrated spectra can accommodate the harder slopes measured by CGRO/BATSE and Fermi/GBM only if the magnetic field lifetime t B is shorter than the time during which the typical GRB electrons cool to radiate below 1–10 keV, which is less than (at most) 10 radiative cooling timescales t rad of the typical GRB electron. In this case, there is a one-to-one correspondence between t B and β LE . To account for low-energy slopes β LE > -3/4, the adiabatic electron-cooling requires a similar restriction on t B . In this case, the diversity of slopes arises mostly from how the electron-injection rate varies with time (temporal power-law injection rates yield power-law low-energy GRB spectra) and not from the magnetic field timescale.

79 ASTRONOMY AND ASTROPHYSICS↗

A 4 x 4 SiPM Sensor Array with Fast Preamplified Output Engineered for the PWO Detectors of the EIC EEEMCAL

The PbWO4 scintillation detectors for the Electron-Ion Collider Electron Endcap Electromagnetic Calorimeter (EEEMCAL) cannot use vacuum photomultipler tubes due to the high magnetic field environment. We are presenting a readout solution with a 4 x 4 SiPM array directly coupled to a preamplification and summing stage. A second amplification stage with variable gain and offset adjustments is also included in the compact electronics module. The integrated power supply feeds the signal processing chain and the adjustable bias control. The parameter settings are saved locally on a EEPROM and are adjustable via the integrated communication interface through USB or RS485. The design was optimized to maximize signal collection energy resolution, for fast timing and wide dynamic range while keeping a small footprint with low power consumption and heat dissipation. The output response is fast enough to meet the 100 ? 200 ns digitization gate requirements for the detector. The electronics assembly requires no active cooling and includes a temperature sensor and a gain compensation of thermal variations which are important features for stable operation in large scale detector structures. A detector prototype was constructed with 20 mm x 20 mm x 200 mm PWO crystals affixed with individual SiPM array readouts and arranged in a 3 x 3 array. This detector was tested at the Thomas Jefferson National Accelerator Facility with 5GeV positrons. We will present the results of these detector characterization measurements.

Philip, O.↗

Integrated solid-state rapid thermo-cycling system

Techniques, systems, and devices are disclosed for implementing a portable lab system for PCR testing. An example method for operating an integrated thermal cycling system includes depositing samples into the integrated thermal cycling system that includes a thermal cycling device and an electronic interface. The thermal cycling device includes multiple wells to receive the samples to be thermally cycled, a thermoelectric cooling (TEC) element connected to the multiple wells, a substrate on which the TEC element is positioned, and a controller coupled to the TEC element. The multiple wells are positioned within the substrate that includes a thermally conductive ground positioned between adjacent wells. Supplying power to the integrated thermal cycling system, via the electronic interface, allows the multiple wells to exchange heat with the substrate and for each well to operate independently from other wells.

Beer, N. Reginald↗

First High-Gradient Results of UED/UEM SRF Gun at Cryogenic Temperatures

Benefiting from the rapid progress on RF photogun technologies in the past two decades, the development of MeV range ultrafast electron diffraction/microscopy (UED and UEM) has been identified as an enabling instrumentation. UEM or UED use low power electron beams with modest energies of a few MeV to study ultrafast phenomena in a variety of novel and exotic materials. SRF photoguns become a promising candidate to produce highly stable electrons for UEM/UED applications because of the ultrahigh shot-to-shot stability compared to room temperature RF photoguns. SRF technology was prohibitively expensive for industrial use until two recent advancements: Nb₃Sn and conduction cooling. The use of Nb₃Sn allows to operate SRF cavities at higher temperatures (4K) with low power dissipation which is within the reach of commercially available closed-cycle cryocoolers. Euclid is developing a continuous wave (CW), 1.5-cell, MeV-scale SRF conduction cooled photogun operating at 1.3 GHz. In this paper, we present first high gradient results of the gun conducted in liquid helium.

43 PARTICLE ACCELERATORS↗

A Low Cost SIPM Evaluation and Control Prototyping System including accurate bias voltage generation, leakage current measurement, and temperature control using Peltier cooling

We describe an electronics system to operate SIPMs in the laboratory. The system is comprised of a single channel amplifier board (SIPM Amp) and a 4-channel control board to which up to 4 SIPM Amp boards can be connected. The control board supplies a common low voltage power for the amplifiers. All channels feature individually regulated bias and Peltier power voltages, along withPt10K RTD readout. A graphical user interface allows control of the bias voltages, amplifier voltage, Peltier voltages, and also provides for readback of leakage currents and other voltages. The GUI app has a feedback loop to measure the SIPM temperature (with the PT10K) and generate correction voltages to the Peltier to regulate the temperature. The temperatures, which can be achieved by Peltier cooling depend on the thermal design of the setup, the practical limit being about 50C below ambient. The SIPM Amp. board is a small (3x5cm) PCB that has a single SIPM readout channel. The SIPM scan be surface mounted on the pcb or connected to a 2-pin 0.100" socket. The area around the SIPM footprint is thermally isolated by perforations in the PCB. The RTD is located inside the thermal break. Onboard is BV and LV filtering. The 10X amplifier is based on MiniCircuits' GALI-S66+ integrated circuit, tweaked for a 6V power. The amplifier was selected for a combination of high bandwidth, low noise, and low power. An accoupled amplifier output is connected to an SMA connector. For best operation of this inverting amplifier the output signal should be in the range of 0 to -1V.The Amplifier board is connected to the Control board with a 10-conductor 0.025" pitch ribbon cable, carrying all the services. Peltier power for currents more than 1A should use a separate 2-contact connector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HIGHLY-EFFICIENT 20-MW L-BAND MULTI-BEAM KLYSTRON

The overall goal of this project was to develop and demonstrate a novel two-stage multi-beam klystron (TS-MBK) for use in accelerator, medical, national security, medical, and environmental cleanup applications. The novelties embodied in the TS-MBK design include use of hollow beams to obtain strong coupling to cavities, and post acceleration after bunching to reduce the beam’s energy spread to allow an exceptional electronic efficiency that we predict can reach 90%. During Phase I of this project, Omega-P R&D refined its conceptual design of the 1.0 GHz TS-MBK, and collector design and cooling requirements for several levels of average power output. If, as was the case, it turned out that estimated costs for fabrication and testing of a full 12-beam TS-MBK prototype would exceed available Phase II funding, our Plan-B would have be adopted. In it, a single-beam version would have been designed and built, with all specifications identical to the 12-beam version, except that the average power level would be reduced by a factor of about 12. This one-beam version would still allow evaluation of the efficacy of our design concept for implementing two stages, including prevention of radiation loss at the HV gap, and for demonstrating the predicted 90% electronic efficiency and the absence of reflected electrons from the collector reaching the cathodes. But the absence of the expected industrial partner in further development of this novel RF source made it impractical for advancing the project into Phase II.

43 PARTICLE ACCELERATORS↗

Influence of conical wire array geometry on plasma flow and temperature profiles of radiatively cooled jets

The influence of conical wire array geometry on the formation and dynamics of pulsed-power driven plasma jets is investigated. In the experiments, the jet becomes isolated from the inflows as it passes through an aperture, allowing the study of its intrinsic evolution for different conical angles. Here, our results show that, regardless of the array opening angle, the jets are supersonic, highly collisional, and exhibit an exponential axial density decay with a characteristic scale length of 𝐿 𝑛 ≈ 3 mm, significantly shorter than the overall length of the jet. In contrast, axial velocity systematically increases with larger array opening angles. The near invariance of the density profile is attributed to a compensating mechanism between geometric divergence and axial acceleration, consistent with an asymptotically steady flow regime. Additionally, temperature measurements reveal ion-electron thermal decoupling near the base of the jet, with equilibration downstream. Analysis of radiative cooling and collisional energy exchange timescales indicates that the plasma evolves in a radiatively stable regime and that the two-temperature profile is fully described by the competition between both methods. These findings provide valuable information into the internal structure and evolution of pulsed-power plasma jets in regimes dominated by geometric shaping and radiative cooling, demonstrating experimental control over flow acceleration and collimation relevant to both laboratory and astrophysical contexts.

Physics - Plasma physics↗

Experimental evaluation of the vapor box divertor concept with an open vapor box module in Magnum-PSI

A promising approach to handle the intense plasma heat flux in the divertor region of a tokamak is the Vapor Box Divertor (VBD). Here plasma-lithium interaction creates a dense lithium vapor cloud which interacts with the incoming plasma, effectively shielding the tungsten surface beneath, therefore preventing overheating and sputtering of the tungsten and increasing the component’s lifetime. Two key steps must be addressed to validate this concept: investigating plasma-Li interactions and the transport mechanism of the latter in the presence of plasma. To explore this, a Vapor Box Module (VBM) has been designed for use with the linear plasma generator Magnum-PSI. The VBM consists of a series of three cylindrical boxes, with Li being evaporated at a controlled temperature in the central box (CB). Divertor-like plasma enters the VBM from an upstream aperture, interacts with the Li vapor cloud and exits through a downstream aperture ultimately impacting a target equipped with a calorimetry system. Optical diagnostics Thomson scattering, Filtered fast camera Imaging and optical emission spectroscopy provided information on plasma parameters in terms of electron density n e , temperature T e and plasma composition before and after this interaction. A significant reduction in plasma power was observed upon the establishment of lithium vaporization determined via cooling water calorimetry and embedded thermocouples at the downstream target. This resulted in a drop of the target temperature from ∼800 °C to ∼350 °C (57%) at the highest applied power (11.1 MW m −2 ) and CB temperature (∼700 °C). Lithium condensation at the side boxes of the VBM in combination with strong plasma momentum transfer effectively prevented upstream migration of lithium, while enhancing Li transport toward the target. The achievement of the two main goals of reducing plasma power and confining the Li in the VBM, are consistent with earlier published preliminary SOLPS-ITER simulations. This study shows that the presence of lithium in a VBD-like configuration can result in a strong reduction of power to the target surface, while at the same time the lithium vapor is effectively confined by the VBM, aided by the incoming plasma, preventing its escape from the VBM geometry. This represents a valuable step toward validating the feasibility of the VBD configuration in future fusion reactors.

Magnum-PSI↗

Recovering the Waste Energy from the Electron-Ion Collider Cooling Water Systems

While only a fraction of the electricity required for the EIC goes into the collision itself, most of the energy ultimately ends up being rejected to the environment via the infrastructure cooling systems. The energy utilized by the RF amplifiers, power supplies, magnets, vacuum systems, and cryogenics systems is rejected to the cooling towers that ultimately dissipate the energy to the atmosphere. Current estimates indicate approximately 50 MW of heat is dissipated at a low temperature by the cooling towers. This technical note is prepared to conceptually demonstrate that feasible options exist to recover the low temperature energy from the EIC cooling water systems.

43 PARTICLE ACCELERATORS↗

Snowmass2021 Topical Group Report from AF07: Targets and Sources

For the next multi-megawatt accelerator generation, targets and other beam-intercepting components will face even more severe challenges due to the higher power densities, higher energy, and higher radiation. A comprehensive research and development program must be implemented to address the challenges. International collaborations such as RaDIATE or High Power Targetry Workshop should be leveraged and expanded to accelerate knowledge gain and avoid duplicated efforts. The next generation of high power targets will need novel designs allowing better high heat flux cooling methods, novel materials, advanced simulations, and better instrumentation. Four main R&D tracks were identified and discussed for targets. For electron sources, current state of art and challenges we are facing for key components such as cathodes, guns and injector design for sources R&D are presented for highly polarized electrons and unpolarized high current high brightness beams. For ion sources such as electron cyclotron resonance ion source (ECRIS), laser ion source (LIS), charge breeders, status of development are reviewed, and areas require investment for future R&D are discussed separately. Facilities critical for various source development are recommended.

43 PARTICLE ACCELERATORS↗

Thermal Management for Planar Package Power Electronics (CRADA Final Report)

The National Renewable Energy Laboratory (NREL) and John Deere Electronic Solutions (JDES) collaborated to develop and evaluate computer models and simulations related to the thermal performance of semiconductor device packaging for an inverter of an off-road vehicle ("Semiconductor Packaging"). The objective of the research was for NREL and JDES to develop a two or three-dimensional computer-aided design model of the Semiconductor Packaging ("Computer Model") for thermal performance evaluation in a simulation. The project developed computer models of a Semiconductor Package of silicon-carbide semiconductor devices with appropriate thermal dissipation via one or more of the following thermal features: a double-sided planar cooling configuration, an air-cooled configuration, a liquid-cooled configuration for off-road inverter applications in a relevant simulated operating environment. It is noted that surface area and prototype product embodiment consisting of air-cooled and liquid-cooled configurations may and may not be in direct contact with power semiconductor chips. The idea was to explore and develop packaging and thermal management technology for power semiconductors that was most effective in the performance yet had least burden in overall product cost for a given application.

33 ADVANCED PROPULSION SYSTEMS↗

Degradation of Poly- and Perfluoroalkyl Substances (PFAS) in Water via High Power, Energy-Efficient Electron Beam Accelerator

The goal of the 2-year workplan was to see if electron beam (EB) could be used to break down a sub-set of the larger chemical family of per and polyfluoroalkylated substances (PFAS) in an energy efficient and economical manner when compared to conventional water treatment technologies. Year one (Y1) work focused on sample EB treatment work in the Fermi National Accelerator Laboratory’s (FNALs) Accelerator Applications Demonstration and Development (A2D2) EB accelerator. While there are reportedly thousands of types of PFAS, for the point of most of the work herein, a small subset was examined, typically perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA). PFOA and PFOS are two of the most well studied PFAS and are studied for baseline evaluations and are considered most useful. The work from Y1 provided information about the optimal operating parameters and additives to use when treating PFOS and PFOA via EB. The data were then used to see where in a water treatment system an EB accelerator would be best suited to treat PFAS. A conventional water treatment technology, GAC, was then compared to e-beam treatment technology with respect to energy and costs for treatment. In year two (Y2), several conventional e-beam accelerator designs, and FNAL’s developmental compact SRF accelerator design, were evaluated for their suitability in PFAS treatment, from an energy efficiency and cost standpoint. Several EB parameters were evaluated and optimized for the removal of PFOA and PFOS from water at normal pressure and temperature, measured as total PFAS removal. Under the optimized test conditions both PFOA showed complete destruction to inorganic fluoride, and PFOS to inorganic fluoride and sulfate, with mass balance. The effect on PFAS removal relative to solution pH, total EB dose, EB dose rate, dissolved oxygen concentration (DO), temperature, and initial PFAS concentration were evaluated. In general, PFOA was easier to destroy than PFOS. Degradation products, typically observed under less-than-optimal EB conditions, provided insight to degradation mechanisms. Products were identified to rule out possible deleterious biproduct formation. The water radiolysis radical reaction kinetics with PFOS and PFOA were not dependent on the initial concentration over 5-orders of magnitude from 2 μg/L to 20 mg/L. This is thought to be because there was an overabundance of the reactive water radiolysis radicals relative to PFAS molecules and largely attributed to aqueous electrons. The reaction rates appeared to be diffusion limited. Testing at higher concentrations (100-200 mg/L) showed a decrease in removal efficiency, suggesting alternative kinetics, possibly second order rates, at higher concentrations. In all, we successfully defined a set of optimal EB parameters to treat PFOA and PFOS at concentrations of 20 mg/L in water with destruction efficiencies near 100%. We further tested the optimized EB parameters with other types of PFAS, including shorter and longer fluorocarbon chain homologs of PFOA and PFOS, and PFAS with alternative functional groups such as sulfonamides. Based on our results EB can be optimized as an effective destructive technology for removing PFAS from water. The conditions optimized for PFOA and PFOS were less effective with ultra-short fluorocarbon compounds like TFMS, PFES, PFPS and PFBS, and likely require re-optimization of parameters to them. In all, it was determined that from a cost and energy efficiency standpoint, EB would be best applied to waste streams with relatively high concentrations of PFOS and PFOA and is not as cost effective as GAC treatment for removing low concentrations of PFAS from water. Higher concentrations of PFAS can be found in the wastewater of conventional treatment processes such as RO and IE and therefore EB may be used to supplement such treatment technologies. Some real-world IE regeneration wash water and RO reject water containing higher concentrations of PFAS and obtained from pilot scale industrial wastewater treatment system at a fluorochemical manufacturing facility, showed that EB could remove PFAS from such types of wastewaters. The IE regenerant wash water appeared to be the most efficient of the two types of wastewaters tested. However, some further optimization of the EB parameters for the specific PFAS types present in those wastewaters may be required. Also, the effects of co-present TOC and mineral salts should be considered during such optimization efforts. From the experimental Y1 results it was seen that the aqueous electron drives degradation of the PFAS. In a hypothetical water treatment skid using EB for PFAS destruction the parameters of the system should be optimized to promote aqueous electron production. Before EB treatment, the PFAS should be preconcentrated when possible, the pH should be raised to pH 10 or higher to enhance aqueous electron production, and the water should be nitrogen purged to remove dissolved oxygen to minimize aqueous electron scavenging. An excel spreadsheet was created that calculates optimal conditions based on inlet PFAS concentration and desired outlet concentration, by optimizing the accelerator power, dose rate, water treatment rate, pH and dissolved oxygen levels to reach the desired endpoint. Given this information on accelerator operating conditions five different EB accelerator systems were compared. One EB system was a continuous-wave, linear superconducting accelerator being designed at Fermilab. Three other EB systems (IMPELA at 5% and 25% duty factor and the ILU-14) were normal conducting pulsed linear accelerators. The fifth system was an IBA Rhodotron which is a normal conducting, circular, continuous-wave accelerator. The accelerator efficiency (% of the incoming power that is used in water treatment) was the dominating factor in accelerator choice. The radio frequency (RF) power supply and the accelerator design (superconducting versus warm technology) drive the accelerator efficiency. The IBA Rhodotron was seen to be the most energy efficient commercially available technology with a wall-plug (total) power efficiency of 43% at 400 kW. The Fermilab design, with a prototype for a different application currently being fabricated, was the most energy efficient at 55% when driven by a Klystron RF power supply and as high as 77% when powered by a magnetron. As the Fermilab design was the most energy efficient by approximately 10-30%, further design work was done on the accelerator and beam delivery system specific to the destruction of PFAS in water. The Fermilab design is unique from industrial accelerators in that is superconducting. Superconducting technology allows for the acceleration of electrons without losses. The accelerator must be cooled to below the point where it is superconducting and is operated around 4 degrees Kelvin. The bulk of the design work for the accelerator is on making the accelerator as energy efficient as possible so that it does not require liquid helium and can be cooled with conduction cooling via cryocoolers. Final design work resulted in an EB accelerator that would operate at minimally 200 kW and 10 MeV. Prototype construction would cost $\$ $7.8 million dollars when driven by a Klystron power supply. A second version of the same accelerator would cost $\$ $5.5 million dollars when driven by a magnetron that is still under development. The commercially available 300 kW IBA Rhodotron cost was estimated at approximately $\$ $9 million. While it is hard to directly compare, an operational GAC system used by 3M for groundwater treatment capital cost (2022 dollars) was estimated to cost $\$ $3.3 million. While the capital expense of the EB accelerator systems was higher than GAC, the accelerator EB treatment would result in destruction of the PFAS and not just sequestration of PFAS to form a new waste stream that requires further treatment or disposal. The operating cost to destroy the PFAS via 400 kw EB system was less than $\$ $1000/kg of PFAS destroyed when treating at a 20 mg/L PFAS concentration, compared to GAC with operating costs that calculated at $\$ $27,530 per kg of PFAS sequestered when treating 100 μg/L PFOA and PFOS combined concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

Integrated solid-state rapid thermo-cycling system

Techniques, systems, and devices are disclosed for implementing a portable lab system for PCR testing. The portable lab system comprises a thermal cycling device including a first well and a second well to receive samples to be thermally cycled, a thermoelectric cooling (TEC) element coupled to the first well and the second well, and a controller to control operation of the TEC element. The portable lab system further includes an electronic interface including a power interface to supply power to the TEC element and the controller of the thermal cycling device to allow the TEC element to transfer energy from the first well to the second well when current flows through the TEC element in a first direction, and from the second well to the first well when current flows through the TEC element in a second direction, and a data interface to collect data from the controller.

59 BASIC BIOLOGICAL SCIENCES↗