Real-Time Testbed for Transmission Line Protection

Hardware in the loop (HIL) testing is crucial for designing and managing electric power grids. These grids are becoming larger and more complex. The importance for students to have safe and intuitive ways to interact with the devices associated with the power grids has never been more crucial. Since most of these tests involve high voltages, this can be a deterrent for instructors and students in undergraduate programs. HIL testing is a solution to these common issues. This method has become one of the most popular methods for testing these power systems. With the use of Western Michigan University’s (WMU) Real-Time Digital Simulator (RTDS) and SEL-421-7 protection relay, a HIL testbed has been created. These devices were interconnected using the communication protocol known as Generic Object-Oriented Substation Event (GOOSE). A simulated transmission line system was modeled in an RTDS software RSCAD as the basis for this testbed. This model simulated different types of faults that could occur in a transmission line while in operation. The SEL-421-7 relay is connected to the RSCAD simulation via GOOSE to protect our simulated transmission line. This testbed was set up to give students a clear understanding of how distance protection works as well as how the SEL-421-7 will react to various kinds of faults, in addition to how useful the RTDS can be when testing different power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

Integration of New Technology Considering the Trade-Offs Between Operational Benefits and Risks: A Case Study of Dynamic Line Rating

Electric grid operators are adept at handling complexity and uncertainty. However, with increasing introduction of renewable generation, distributed energy resources, and more frequent severe weather events, operators will experience new workload and challenging decision scenarios. Here, this paper quantifies risks and benefits from an operator's perspective of introducing weather based forecast Dynamic Line Ratings (DLR) using variable wind conditions in addition to ambient temperature to relieve transmission congestion and facilitating more offshore wind (OSW). A concept of operations (CONOPS) applied to a forecast DLR implementation and its integration with OSW is defined. A method for evaluating tradeoffs of derating to make the rating more conservative but decreasing the benefit was developed and applied to a case study for two existing overhead transmission lines on Long Island, New York. The CONOPS uses historical day-ahead and hour-ahead High Resolution Rapid Refresh weather forecasts and weather station data to support planning and real-time operations. The analysis determines the risk of downgrades in real-time operational rating compared to the forecast and quantifies the frequency and severity of last-minute downgrades. The risk is compared against the benefits in increased capacity to provide insights on the additional amount of uncertainty DLR and OSW will add to the operator's workload.

17 WIND ENERGY↗

BEAM COLLIMATION IN THE PIP-II LINAC TO BOOSTER TRANSFER LINE

The new PIP-II superconducting linac will deliver a 2 mA average H⁻ beam to the existing Booster synchrotron. The injected beam is accumulated by charge exchange over approximately 300 turns; phase space painting is used to mitigate space charge effects. To limit the power load on the internal waste beam absorber from the transverse tails of the H⁻ distribution missing the foil, the beam will be collimated in both planes in the linac to Booster transfer line using compact collimators of a novel design. Both the number of parasitic hits and the fraction of the beam missing the foil are sensitive functions of the H⁻ beam centroid position with respect to the edge of the foil. The positioning of the collimation is constrained by the availability of suitable space in the transfer line lattice, by specifics of the collimator design, by the phase space orientation at the collimator, and by the betatron phase advance to the foil needed to achieve proper orientation of the spatial distribution at the injection point. In this contribution, we describe the procedure by which collimator positions were optimized. We then discuss the expected performance of the overall system.

Johnson, David E.↗

Enabling DER Participation in Frequency Regulation Markets

Distributed energy resources (DERs) are playing an increasing role in ancillary services for the bulk grid, particularly in frequency regulation. In this article, we propose a framework for collections of DERs, combined to form microgrids and controlled by aggregators, to participate in frequency regulation markets. Our approach covers both the identification of bids for the market clearing stage and the mechanisms for the real-time allocation of the regulation signal. The proposed framework is hierarchical, consisting of a top layer and a bottom layer. The top layer consists of the aggregators communicating in a distributed fashion to optimally disaggregate the regulation signal requested by the system operator. The bottom layer consists of the DERs inside each microgrid whose power levels are adjusted so that the tie line power matches the output of the corresponding aggregator in the top layer. The coordination at the top layer requires the knowledge of cost functions, ramp rates, and capacity bounds of the aggregators. We develop meaningful abstractions for these quantities respecting the power flow constraints and taking into account the load uncertainties and propose a provably correct distributed algorithm for optimal disaggregation of regulation signals among the microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Forecasted Dynamic Line Ratings for Regional Transmission Lines

This report was prepared for the Wind Energy Technology Office for the FY 2022, quarter 3 deliverable. This details the use of forecasted dynamic line rating as an improvement over static rating for three transmission lines in three regions of interest. A selection of wind plants across Idaho, the Columbia River Gorge and offshore wind in the NYSERDA territory were modeled for their concurrent cooling effects for dynamic line rating. Regional transmission lines for the wind plant interconnections were determined and a CFD domain was created to determine local wind flows over the lines. A dynamic line rating for each of the lines was calculated for both weather observation data and HRRR model forecast data. The comparison of peaks in the wind power production were compared to the DLR peaks. It was determined that for shorter regional transmission lines, the effect of concurrent cooling that commonly occur with gen-tie lines were still valid. Concurrent cooling effects drop as the length of the regional transmission lines increase in distance from the wind plants. In addition, the accuracy of the forecasted ampacity to the weather observation data for ampacity was assessed. In general, the accuracy was best for the INL region with the NOAA-maintained sites. The Columbia River Gorge and Long Island sites showed similar levels of accuracy for the forecasted DLR. The accuracy levels were around 11% for the INL region, 15% for Columbia River Gorge and 7% for New York Long Island. The higher error for the Columbia Gorge region is likely due to the sparse availability of weather stations available, whereas both the INL site and Long Island are well instrumented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimized Dispatch of Distributed Energy Resources for Resiliency and Power Quality Improvements at the Grid-Edge

Distributed Energy Resources (DERs) installed on low-voltage distribution systems, both utility-owned and nonutility owned may be employed to make improvements to system resiliency and power quality, in addition to simply serving load demand. By selectively dispatching active and reactive power from these existing DERs, improvements in voltage profiles and service availability during adverse events may be achieved. Further benefits can be gained by optimally choosing which DERs to dispatch power from, and the distribution of power from those DERs. For a given operating condition, using Linear Programming methods, optimal power dispatch values for individual DERs can be determined, while considering variables such as voltage gains, losses in the lines and the DERs, and DER reserve capacities. One such optimization technique is developed in this paper, and results from a real-time simulation study on a modified IEEE 13-bus distribution system with three DERs, are being presented. The operation of the optimized DER selection and dispatch algorithm is shown during normal operation of the transmission system when the DERs operate in grid-connected mode. Similar analyses can drive decision making during transmission system failure when the DERs operate in grid-forming or islanded mode.

Chowdhury, Prithwiraj Roy↗

Microwave-enhanced catalytic ammonia synthesis under moderate pressure and temperature

In this study, an alternative approach based on microwave-enhanced ammonia synthesis for Haber-Bosch process was carried out under moderate pressure of 0.1–0.65 MPa and temperature range of 280–400 °C over a stable CsRu/CeO 2 catalyst. The ammonia production rate is significantly improved under microwave conditions. At 0.65 MPa and 320 °C, maximum ammonia production rate was achieved at H 2 /N 2 ratio of 1/1. Stable performance was obtained in a 6-cycles of startup-shutdown operation for cumulative on-line time of 80 h. The work demonstrates the potential of microwave catalytic technology for the distributed ammonia synthesis using renewable power having intermittent nature of energy supply.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photovoltaic Inverter Momentary Cessation: Recovery Process is Key

Momentary cessation refers to an inverter control mode. When the inverter terminal voltage falls below (or exceeds) a certain level, the inverter ceases to output any current, but attempts to maintain (or quickly regain) phase-locked loop synchronization to allow for quick reinjection of current when the voltage recovers to a certain point. This paper presents a photovoltaic (PV) momentary cessation model developed in PSS/E. Simulations are presented for a high voltage transmission line fault contingency in the Hawaiian island of Oahu power system on a validated PSS/E model, modified to include a custom distributed PV inverter model, and different near-future distributed PV penetration levels. Simulations for the island power system include different penetration levels of PV, and different recovery times (ramp rates and delays) after momentary cessation. The results indicate that during low voltage events, such as faults, momentary cessation can produce severe under frequency events, causing significant load shed and shortly thereafter, in some cases, over frequency events that cause generation to trip offline. The problem is exacerbated with higher penetration levels of PV. If momentary cessation is used (as is typically the case for distribution-connected resources), the recovery process after momentary cessation should be carefully considered to minimize impacts to bulk power system stability.

14 SOLAR ENERGY↗

Understanding Solar Photovoltaic System Performance: An Assessment of 75 Federal Photovoltaic Systems

This report presents a performance analysis of 75 photovoltaic systems based on PV system production data collected as part of a FEMP Federal PV Performance Assessment project combined with co-incident insolation, and ambient temperature to analyze how actual performance compares with a performance model. FEMP collaborated with 17 Federal agencies and sub-agencies to collect the information required to analyze the performance of each system. The systems represent a total capacity of 30,714 kW and range in size from 1 kW to 4,043 kW, with an average size of 410 kW, and were installed between 2011 and 2020. The data is analyzed for Key Performance Indicators, Availability, Performance Ratio and Energy Ratio by comparing the measured production data to model production data. The System Advisor Model (SAM) combines a description of the system (such as inverter capacity, de-rating for temperature, balance-of-system efficiency) with environmental parameters (coincident solar and temperature data) to calculate predicted performance. The performance metrics are calculated by lining up the measured production data with the model estimate on an hour-by-hour, day-by-day, or month-by-month basis (depending on the interval resolution of the production data). A report with system description, photo of the system, special assumptions made for the site, graph of measured production and model production, table of key performance indicators, and links to O&M resources that might improve performance was produced and delivered to site and agency staff with a short on-line briefing.

14 SOLAR ENERGY↗

A Review on Building Resilient Power Networks: Emphasizing Adjacent Span Dynamics

This research article presents a comprehensive review of resilience in power transmission and distribution systems, focusing on key studies that examine structural integrity, mechanical stress distribution, and system reliability under various conditions. The article synthesizes findings across multiple studies, covering assumptions, system topologies, methodologies, and challenges that affect resilience in these networks. Particular attention is given to identifying studies that address the influence of adjacent spans and tower--line interactions, as these factors play a crucial role in the stress distribution and structural dynamics within poles, towers, and transmission lines. In addition to identifying critical factors contributing to system vulnerability, this review emphasizes the importance of continued research to better understand and mitigate risks from extreme events, such as high winds combined with ice storms. By consolidating knowledge on current challenges and future needs, this work outlines future directions to advance resilience studies and contributes to ongoing efforts to strengthen power transmission and distribution networks, reducing disruptions in electricity supply and improving overall system resilience in an evolving climate landscape.

Ahmad, Tawsif [Pacific Northwest National Laborato↗

A New Window into the Baryon Cycle at Cosmic Noon with Line Intensity Mapping: Forecasts for auto- and cross-correlations in [CII]-158$μ$m, HI 21 cm, CO$_{J+1\rightarrow J}$, and H$α$ galaxies

Across the peak of cosmic star formation at $z\sim1-2$, inflow, processing, and feedback drive rapid changes in the spatial distribution and chemical composition of baryons in galaxies and surrounding reservoirs; this baryon cycle can be tomographically mapped by line intensity mapping (LIM) of atomic hydrogen, ionized carbon, and carbon monoxide. We present a simulation-based forecasting framework for detecting auto- and cross-power spectra between spectroscopic surveys of four such tracers at $z\sim0.5-1.7$ mapping the same deep field - TIM, EoRSpec/FYST, MeerKAT, & Euclid. We forward-model 3-D distributions for these tracers from magnetohydrodynamic simulations, directly capturing the two-halo, one-halo, and shot statistics without relying on analytical decompositions. We further detail a signal-to-noise formalism, tailored to LIM surveys with highly anisotropic geometries and Fourier-space coverage. We demonstrate that galaxy cross-correlations will be the dominant discovery channel for current-generation surveys. These instruments will detect the auto-spectra for CO and HI 21 cm and the CO $\times$ 21 cm cross-spectrum at modest S/N $\sim 1-10$, while placing upper limits on the [CII]-158$μ$m signals. [CII], CO, and HI LIM will be $\sim3-30\times$ ($0.5-1.5$ dex) more sensitive to cross-correlation with the Euclid survey, however, than their respective auto-correlations, constraining all three models of line emission at high significance (S/N $\sim 10-40$) within this decade. Finally, we formulate a staged instrumental trajectory with planned or reasonable improvements, including the as-proposed SKA-Mid. We forecast advancing the per-$k$-mode sensitivities of each auto-, galaxy-line, and line-line spectrum by several orders of magnitude, enabling new percent- and sub-percent level constraints on cosmology and the redshift evolution of star formation and the baryon cycle.

Agrawal, Shubh [Pennsylvania U., Dept. Math.]↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Report for Task 10: Controllability and Observability Analysis (Deliverable D7))

It is common to have less than full observability for distribution systems, as the number of available measurements are not sufficient. Considering increasing penetration of distributed energy resources (DERs), it is imperative to understand and control distribution systems better. Developed for the transmission system, the original numerical observability analysis methods were based on the canonical DC Power Flow (DC-PF) model. However, the DC-PF model is ill-suited for the distribution system in which line resistance to reactance (R/X) ratios can be near unity. In this report, we apply the non-iterative Observability Test (OT) and Observable Island Identification Procedure (OIIP) in to the gain matrix from the distribution system state estimator. Because sensors are few in distribution systems, pseudo-measurements based on historical load profiles and zero-injection virtual measurements are often employed to ensure observability. However, both the observability and the accuracy of the state estimates are uncertain when historical data is limited/unavailable.

42 ENGINEERING↗

Linear Approximation Line Pack Model for Integrated Electricity and Natural Gas Systems OPF

With the increasing installation of renewable energy electricity generation capacity, the penetration of natural gas fired generation is also substantailly increasing in power systems due to their fast response capability to mitigate system variability and uncertainty. The dependencies between the electricity system and the natural gas system are becoming more important to maintain the reliability of both systems. In integrated electricity and natural gas systems (IEGSs) operations, the nonlinearity of the natural gas system brings challenges to the system operators. In this paper, the IEGSs optimal power flow (OPF) model is proposed that includes the line pack of the gas system via linear approximation. The simulation results demonstrate that the proposed model can obtain optimal solutions efficiently that are comparable in accuracy as the nonlinear line pack model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimation of the Attenuation Caused by Power Line Towers on an E1-HEMP Induced Excitation

In a transmission line, the coupling between a line and a tower above ground is evaluated when the excitation is an E1 high-altitude electromagnetic pulse (HEMP). The model focuses on capturing correctly the effect of the coupling on the peak of the HEMP induced current that propagates along the line. This assessment is necessary to accurately estimate the effect of the excitation on the systems and components of the power grid. This analysis is a step towards a quantitative evaluation of HEMP excitation on the power grid. The results obtained indicate that the effect can be significant, especially for lines heights of 20 meters or more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of a Reduced-Order Model for IBR Fault Response Representation via OEM Blackbox Models

This paper presents a fully implemented inverter reduced-order-model (ROM) in an EMT simulation (PSCAD) library component for direct user utilization in protection studies. The developed inverter ROM has the following features: Equivalent to a full inverter-based resource (IBR) inverter model with positive- and negative-sequence current formulation and representation. A Python script is developed to fully automate this process, including training data generation, ROM parameter training, updating parameters, and model verification and validation. The ROM is validated using both IEEE 2800-compliant and non-compliant OEM modes in a real-world system, building confidence of its usability by protection engineers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preventive Power Outage Estimation Based on a Novel Scenario Clustering Strategy

The increasing occurrence of extreme weather events is challenging power grid operation. For extreme weather events, the system operator is responsible for estimating the power outages and scheduling the restoration resources. This paper proposes an outage evaluation framework to identify the possible unserved load profiles, vulnerable areas, and mobile energy adequacy. The outputs of an outage prediction model tool are used to generate numerous faulted line scenarios. Next, each scenario's nodal unserved load profile is obtained by solving a three-phase restoration model that considers repair crews and mobile energy resources (MERs). Then, a novel scenario clustering strategy is developed to cluster the unserved load profiles into multiple representative profiles which the system operator can focus on. Finally, case studies on a distribution system evaluate the damage caused by an extreme weather event and verify the effectiveness of the proposed scenario clustering strategy.

MATHEMATICS AND COMPUTING,POWER TRANSMISSION AND D↗