A Commercial Building Plug Load Management System that Uses Internet of Things Technology to Automatically Identify Plugged-In Devices and Their Locations

Plug and process loads (PPLs) account for a large portion of U.S. commercial building energy use. There is a huge potential to reduce whole building consumption by targeting PPLs for energy savings measures or implementing some form of plug load management (PLM). Despite this potential, there has yet to be a widely adopted commercial PLM technology. This paper describes the Automatic Type and Location Identification System (ATLIS), a PLM system framework with automatic and dynamic load detection (ADLD). ADLD gives PLM systems the ability to automatically identify devices as they are plugged into the outlets of a building. The ATLIS framework takes advantage of smart, connected devices to identify device locations in a building, meter and control their power, and communicate this information to a central database. ATLIS includes five primary capabilities: location identification, communication, control, energy metering, and data storage. A laboratory proof of concept (PoC) demonstrated all but the energy metering capability, and these capabilities were validated using a series of system tests. The PoC was able to identify when a device was plugged into an outlet and the location of the device in the building. When a device was moved, the PoC's dashboard and database were automatically updated with the new location. The PoC implemented controls to devices from the system dashboard so that devices maintained correct schedules regardless of where they were plugged in within the building. ATLIS's primary technology application is improved PLM, but other applications include asset management, energy audits, and interoperability for grid-interactive efficient buildings. An ATLIS-based system could also be used to direct power to critical devices, such as ventilators, during a brownout or blackout. Such a framework is an opportunity to make PLM more widespread and reduce the amount of energy consumed by PPLs in current and future commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Proposal for a Vehicle Level Test Procedure to Measure Air Conditioning Fuel Use

The air-conditioning (A/C) compressor load significantly impacts the fuel economy of conventional vehicles and the fuel use/range of plug-in hybrid electric vehicles (PHEV). A National Renewable Energy Laboratory (NREL) vehicle performance analysis shows the operation of the air conditioner reduces the charge depletion range of a 40-mile range PHEV from 18% to 30% in a worst case hot environment. Designing for air conditioning electrical loads impacts PHEV and electric vehicle (EV) energy storage system size and cost. While automobile manufacturers have climate control procedures to assess A/C performance, and the U.S. EPA has the SCO3 drive cycle to measure indirect A/C emissions, there is no automotive industry consensus on a vehicle level A/C fuel use test procedure. With increasing attention on A/C fuel use due to increased regulatory activities and the development of PHEVs and EVs, a test procedure is needed to accurately assess the impact of climate control loads. A vehicle thermal soak period is recommended, with solar lamps that meet the SCO3 requirements or an alternative heating method such as portable electric heaters. After soaking, the vehicle is operated over repeated drive cycles or at a constant speed until steady-state cabin air temperature is attained. With this method, the cooldown and steady-state A/C fuel use are measured. This method can be run at either different ambient temperatures to provide data for the GREEN-MAC-LCCP model temperature bins or at a single representative ambient temperature. Vehicles with automatic climate systems are allowed to control as designed, while vehicles with manual climate systems are adjusted to approximate expected climate control settings. An A/C off test is also run for all drive profiles. This procedure measures approximate real-world A/C fuel use and assess the impact of thermal load reduction strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Control Strategies for Electric Vehicle (EV) Charging Using Renewables and Local Storage

The increase of electric vehicle (EV) and plug-in hybrid-electric vehicle (PHEV) adoption creates a need for more EV supply equipment (EVSE) infrastructure (i.e., EV chargers). The impact of EVSE installations could be significant due to limitations in the electric grid and potential demand charges for residential and commercial customers. The use of renewables (e.g., solar) and local storage (e.g., battery bank) can mitigate loads caused by EVSE on the electric grid. This would eliminate costly upgrades needed by utilities and decrease demand charges for consumers. This paper aims to explore control systems that mitigate the impact of EVSE on the electric grid using solar energy and battery banks. Three control systems are investigated and compared in this study. The first control system discharges the battery bank at a constant rate during specific times of the day based on historical data. The second discharges the battery bank based on the number of EVs charging (linear) and the amount of solar energy being generated. The third discharges the battery bank based on a sigmoid function (non-linear) in response to the number of EVs charging, and also takes into consideration the amount of renewables being generated. The first and second control systems recharge the battery bank at night when demand charges are lowest. The third recharges the battery bank at night and during times of the day when there is an excess of solar. Experiments are conducted using data from a private site that has 25 solar-assisted charging stations at Oak Ridge National Laboratory (ORNL) in Oak Ridge, TN and 4 at a public site in Nashville, TN. Results indicate the third control system having better performance, negating up to 71% of EVSE load, compared with the second control system (up to 61%) and the first control system (up to 58%).

Castello, Charles C↗

Fast 704 MHz Ferroelectric Tuner for Superconducting Cavities

The Omega-P SBIR project described in this Report has as its goal the development, test, and evaluation of a fast electrically-controlled L-band tuner for BNL Energy Recovery Linac (ERL) in the Electron Ion Collider (EIC) upgrade of the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL). The tuner, that employs an electrically-controlled ferroelectric component, is to allow fast compensation to cavity resonance changes. In ERLs, there are several factors which significantly affect the amount of power required from the wall-plug to provide the RF-power level necessary for the operation. When beam loading is small, the power requirements are determined by (i) ohmic losses in cavity walls, (ii) fluctuations in amplitude and/or phase for beam currents, and (iii) microphonics. These factors typically require a substantial change in the coupling between the cavity and the feeding line, which results in an intentional broadening of the cavity bandwidth, which in turn demands a significant amount of additional RF power. If beam loading is not small, there is a variety of beam-drive phase instabilities to be managed, and microphonics will still remain an issue, so there remain requirements for additional power. Moreover ERL performance is sensitive to changes in beam arrival time, since any such change is equivalent to phase instability with its vigorous demands for additional power. In this Report, we describe the new modular coaxial tuner, with specifications suitable for the 704 MHz ERL application. The device would allow changing the RF-coupling during the cavity filling process in order to effect significant RF power savings, and also will provide rapid compensation for beam imbalance and allow for fast stabilization against phase fluctuations caused by microphonics, beam-driven instabilities, etc. The tuner is predicted to allow a reduction of about ten times in the required power from the RF source, as compared to a compensation system with narrower bandwidth. It is planned to build a 704 MHz version of the tuner, to check its underlying principles, and to make high-power tests at power densities aimed towards controlling 50 kW of average power. Steps towards this goal will be limited by, among other factors, losses in the actual ferroelectric elements in the ferroelectric assemblies. As the ferroelectric material loss tangent is reduced through efforts by the supplier Euclid TechLabs LLC, the concomitant power loss in its ferroelectric assemblies will drop, and the average power-handling capability of the Omega-P tuner will rise. It can thus be anticipated that the Phase II development project of the 704 MHz tuner will be iterative, but the pace and ultimate power-handling level of the tuner is difficult to predict at this early stage in Euclid's development program. Fortunately, since Omega-P's conceptual tuner is a simple module (nominally rated for 5 kW), so that the number of modules required in each tuner can be chosen, depending upon the cavity power level needed, plus the power for tuner losses.

43 PARTICLE ACCELERATORS↗

Optimization and Control Theory for Smart (Power) Grids [Slides]

The national interest in a broad class of problems loosely characterized as the smart grid is rapidly growing. At its core, the smart grid is the modernization of our existing electric power systems through improvements in efficiency, increased robustness and resiliency, integration of time-variable renewable generation, and reduction of environmental impacts. To date, the focus of most commercial entities has been on development of hardware such as smart meters and green technologies. However, with the exception of a handful of academic researchers, there has been limited research on optimization, control and more broadly, the information science required to effectively utilize this hardware. Our proposal targets development of the basic information science that will effectively bridge this gap. Using our expertise in information theory, network analysis, infrastructure analysis and power engineering, we will develop new algorithms for optimal design of the nation's next generation power transmission and distribution system that address the realities and challenges of the future grid. We focus on three core information science challenges in Grid Design, Grid Control and Grid Stability by considering a set of challenging problems. First, we study efficient and robust integration of geographically widespread renewable generation by solving large, cutting-edge optimization problems that incorporate difficult constraints imposed by the transmission of electrical power. Second, we consider two load balancing problems in the low-voltage distribution grid: development of robust and efficient distributed control techniques and algorithms based on queuing theory. These tools will enable high penetration of small-scale distributed generation and plug-in hybrid vehicles with limited or no communications. We will also develop efficient control algorithms for maintaining an operational distribution grid via switching of redundant lines. Third, we will develop a preventive toolbox capable of detecting instabilities and failures prior to their occurrence. Damaging failures and cascading outages, which can result in billions of dollars worth of damage, have substantial economic consequences. We will focus on estimating the probability of these outages, identifying their signatures and precursors, and developing detection algorithms for alerting the transmission grid operator. The new challenges in IS&T for smart grids require coherent advances in analysis and control, stability and reliability metrics, state estimation, data aggregation and assimilation, and communication middleware for the grid as well as understanding consumer response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Study of Performance, Comfort, and Sizing of Two Variable-Speed Heat Pumps Installed in a Single 2-Story Residence

With the recent advancements in the application of variable-speed (VS) compressors to residential HVAC systems, opportunities are now available to size heat pumps (HPs) to more effectively meet heating and cooling loads in many of the climate zones in the US with limited use of inefficient resistance heat. This is in contrast to sizing guidance for traditional single-speed HPs that limits the ability to oversize with regard to cooling loads, because of risks of poor dehumidification during the cooling season and increased cycling losses. VS-drive HPs can often run at 30-40% of their rated cooling capacity to reduce cycling losses, and can adjust fan speed to provide better indoor humidity control. Detailed air-side performance data was collected on two VS-drive heat pumps installed in a single unoccupied research house in Knoxville, TN, a mixed-humid climate. One system provided space conditioning for the upstairs, while the other unit provided space conditioning for the downstairs. Occupancy was simulated by operating the lights, shower, appliances, other plug loads, etc. to simulate the sensible and latent loads imposed on the building space by internal electric loads and human occupants according to the Building America Research Benchmark (2008). The seasonal efficiency and energy use of the units are calculated. Annual energy use is compared to that of the single speed minimum efficiency HPs tested in the same house previously. Sizing of the units relative to the measured building load and manual J design load calculations is examined. The impact of the unit sizing with regards to indoor comfort is also evaluated.

Munk, Jeffrey D↗

A Perspective of Energy Codes and Regulations for the Buildings of the Future

Today’s building energy codes focus on prescriptive requirements for features of buildings that are directly controlled by the design and construction teams and verifiable by municipal inspectors. Although these code requirements have had a significant impact, they fail to influence a large slice of the building energy use pie – including not only miscellaneous plug loads, cooking equipment and commercial/industrial processes, but the maintenance and optimization of the code-mandated systems as well. Currently, code compliance is verified only through the end of construction, and there are no limits or consequences for the actual energy use in an occupied building. In the future, our suite of energy regulations will likely expand to include building efficiency, energy use or carbon emission budgets over their full life cycle. Intelligent building systems, extensive renewable energy, and a transition from fossil fuel to electric heating systems will likely be required to meet ultra-low-energy targets. This paper lays out the authors’ perspectives on how buildings may evolve over the course of the 21st century and the roles that codes and regulations will play in shaping those buildings of the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Resources and Techniques to Evaluate Smart Home Technology: Preprint

Smart home technologies promise to make residential buildings more comfortable, less costly to operate, more energy efficient, and more integrated with the grid, but these systems are difficult to evaluate in traditional laboratory spaces. To aid in the development and evaluation of new home energy management systems (HEMS), NREL built the Systems Performance Laboratory (SPL) within the Energy Systems Integration Facility. SPL has electrical infrastructure for three residential buildings, complete with smart meters, breaker panels and a full complement of major and minor appliances in each 'home.' Cord and plug power connections mean that appliances can easily be swapped for different models. Distributed energy resources (DER), such as residential photovoltaic (PV) inverters and home batteries, are also available for integration. Sensors monitor the power consumption of all loads and controllers can simulate occupancy to drive the appliances in realistic ways. A novel hardware-in-the-loop application was developed to ensure air conditioner cycling by combining a building simulation with a physical air conditioner and a thermostat, which allows us to simulate performance in any climate with any building construction. Another application of the hardware-in-the-loop technique uses a grid simulation to model the grid impact for different control strategies related to smart home technologies. This laboratory is a powerful, flexible tool that can be employed to evaluate the effect that home energy management and other smart home technologies will have at the appliance, whole-home, and distribution feeder levels - all of which are important perspectives for different stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radio Frequency Sensing of Particulate Matter Accumulation on a Gasoline Particulate Filter

Filter Sensing Technology’s radio frequency (RF) sensor for particulate filter on-board diagnostics (OBD) was studied on a lean gasoline engine at the National Transportation Research Center (NTRC) at Oak Ridge National Laboratory (ORNL). The response of the RF sensor to particulate matter (PM) or “soot” accumulation on the gasoline particulate filter (GPF) installed in the engine exhaust was evaluated. In addition, end plugs of the GPF were purposely removed, and subsequent changes to the RF sensor measured soot loading on the GPF were characterized. Results from the study showed that the RF sensor can accurately measure soot accumulation on a GPF; furthermore, the predicted decreased soot accumulation due to plug removal was detected by the RF sensor. Overall, the studies were short and preliminary in nature; however, clearly, the RF sensor demonstrated the capability of measuring GPF soot loading at a level suitable for use in lean gasoline engine emission control OBD and control.

33 ADVANCED PROPULSION SYSTEMS↗

NREL RSF Measured Data 2011

Modern buildings are complex energy systems that must be controlled for energy efficiency. The Research Support Facility (RSF) at the National Renewable Energy Laboratory (NREL) has hundreds of controllers -- computers that communicate with the building's various control systems -- to control the building based on tens of thousands of variables and sensor points. These control strategies were designed for the RSF's systems to efficiently support research activities. Many events that affect energy use cannot be reliably predicted, but certain decisions (such as control strategies) must be made ahead of time. NREL researchers modeled the RSF systems to predict how they might perform. They then monitor these systems to understand how they are actually performing and reacting to the dynamic conditions of weather, occupancy, and maintenance. This submission includes the Measured Energy Data from the RSF Systems Model. The data includes a csv with measured data from NREL's Research and Support Facility (RSF) for 2011. The dataset contains hourly data for: Total Cooling (kW)- Total Heating (kW)- Total Mechanical (kW)- Total Lighting (kW)- Total Plug Loads (kW)- Total Data Center (kW)- Total Building (kW)- PV (kW)- Building Net (kW). Energy Model data and Weather data related to the RSF Systems Model can be found in the "Related Datasets" section of this submission.

2011↗

Leading in Los Angeles: Demonstrating scalable emerging energy efficient technologies for integrated façade, lighting, and plug loads INTER System FLEXLAB Test Report

This report is a part of the California Energy Commission (Energy Commission) EPIC study Leading in Los Angeles: Demonstrating scalable emerging energy efficient technologies for integrated façade, lighting, and HVAC. The set of technologies are called the Integrated Technologies for Energy-efficient Retrofits (INTER) and are comprised of automated shading products and LED lighting systems with networked luminaire-level sensors and controls. In addition, the project will include control modifications and assessments of HVAC savings. This document includes the test plan and test results for the FLEXLAB® testing of the shading and lighting INTER system and related energy use impact. The test plan describes the test objectives and features, test cases, schedule, and measurements. The test results cover system performance in the lab; including lighting and HVAC energy, visual comfort, and thermal comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Analysis Progress of ITER Diagnostic Equatorial Port #09

ITER is the world's largest fusion device currently under construction in the South of France with >50 diagnostic systems to be installed inside the port plugs (PPs), the interspace (IS), or the port cell region of various diagnostic ports. The plasma facing diagnostic first wall (DFW) and its supporting diagnostic shield modules (DSM) are designed to protect front-end diagnostics from plasma neutron and plasma radiation, while providing apertures for diagnostic access to the plasma. The design of ITER port plug structures including the DFW and the DSM is largely driven by the electromagnetic loads included on the PP structural components during plasma major disruptions and the vertical displacement events (VDEs). Unlike DFW and DSM, the design of diagnostic system, however, is likely driven by the steady-state thermal loads from plasma volumetric and surface heating and the dynamic response of the in-port components attached to the port-specific DSM or closure plate under transient loads induced on the vacuum vessel and the port extension during asymmetric VDEs. Three tenant diagnostic systems are integrated into the equatorial port 09. The toroidal interferometer/polarimeter, or TIP system, is installed in the left drawer (DSM3, left looking from plasma) for measuring the plasma density so to control the fuel input. The electron cyclotron emission (ECE) system is installed in the middle drawer (DSM2) to provide the high spatial and temporal resolution measurements of electron temperature evolution and the electron thermal transport inferences. The visible/infrared wide angle viewing system is installed in the right drawer (DSM1) to provide visible and infrared viewing and temperature data of the first wall for its protection in support of machine operation. The port plug integration design and multiphysics analyses are performed following port integration requirements including the weight limit (45 tones total), shut down dose rate limits, the cooling/heating and structural integrity validation. Mass distribution for TIP and ECE DSMs has been optimized to minimize the total weight by a new design of the boron carbide shielding pocket. Furthermore, the lightened DSM maintains its front-end load distribution and the structural stiffness with minimum impact to the DFW so to better protect on-board diagnostics; while still provides sufficient front-end stiffness for its structural integrity as well as the diagnostics function requirements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulating energy performance of buildings: a study using eQUEST and Energy Star ® portfolio manager

Commercial buildings consume significant energy in the United States and exhibit high potential for energy use reduction through retrofits. Benchmarking and energy simulation are well established tools in the industry to identify potential improvements and measure performance. Analysis to identify most sensitive retrofit parameters to energy performance can optimize investment and available energy savings. Presented study demonstrates methodology using a static model to determine sensitivity of building design and retrofit parameters with respect to energy performance. Calibrated simulation energy models (eQUEST) of two distribution centers (A, B) are presented. A fractional factorial analysis is conducted on retrofit parameters of efficiency measures targeting the highest energy consumers, and the results are benchmarked using Energy Star® Portfolio Manager. A custom Microsoft Excel® based simulation model is created to simulate occupancy levels, lighting, plug loads, and other equipment used in various spaces throughout the day. For Building A, efficient lighting was the most influential parameter for energy savings, carbon savings and benchmarking score; whereas, for Building B, HVAC efficiency was most influential for energy and demand controlled ventilation and economizers was most influential for benchmarking score. While retrofit projects can save energy and carbon emissions, variation in source-site ratios and state grid emissions, benchmarking scores may not always reflect equivalent improvement. State grid emissions factors, natural gas composition are difficult to model and hence not considered in this study. In conclusion, the synergistic analysis presented, emphasizes the importance of benchmarking and efficiency retrofits in promoting sustainable building practices to reduce energy consumption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Capturing Dynamics in the Power Grid: Formulation of Dynamic State Estimation through Data Assimilation

With the increasing complexity resulting from uncertainties and stochastic variations introduced by intermittent renewable energy sources, responsive loads, mobile consumption of plug-in vehicles, and new market designs, more and more dynamic behaviors are observed in everyday power system operation. To operate a power system efficiently and reliably, it is critical to adopt a dynamic paradigm so that effective control actions can be taken in time. The dynamic paradigm needs to include three fundamental components: dynamic state estimation; look-ahead dynamic simulation; and dynamic contingency analysis (Figure 1). These three components answer three basic questions: where the system is; where the system is going; and how secure the system is against accidents. The dynamic state estimation provides a solid cornerstone to support the other 2 components and is the focus of this study.

97 MATHEMATICS AND COMPUTING↗

Micropillar compression technique applied to micron-scale mudstone elasto-plastic deformation.

Mudstone mechanical testing is often limited by poor core recovery and sample size, preservation and preparation issues, which can lead to sampling bias, damage, and time-dependent effects. A micropillar compression technique, originally developed by Uchic et al. 2004, here is applied to elasto-plastic deformation of small volumes of mudstone, in the range of cubic microns. This study examines behavior of the Gothic shale, the basal unit of the Ismay zone of the Pennsylvanian Paradox Formation and potential shale gas play in southeastern Utah, USA. Precision manufacture of micropillars 5 microns in diameter and 10 microns in length are prepared using an ion-milling method. Characterization of samples is carried out using: dual focused ion - scanning electron beam imaging of nano-scaled pores and distribution of matrix clay and quartz, as well as pore-filling organics; laser scanning confocal (LSCM) 3D imaging of natural fractures; and gas permeability, among other techniques. Compression testing of micropillars under load control is performed using two different nanoindenter techniques. Deformation of 0.5 cm in diameter by 1 cm in length cores is carried out and visualized by a microscope loading stage and laser scanning confocal microscopy. Axisymmetric multistage compression testing and multi-stress path testing is carried out using 2.54 cm plugs. Discussion of results addresses size of representative elementary volumes applicable to continuum-scale mudstone deformation, anisotropy, and size-scale plasticity effects. Other issues include fabrication-induced damage, alignment, and influence of substrate.

03 NATURAL GAS↗

User-Loaded SlipChip for Equipment-Free Multiplexed Nanoliter-Scale Experiments

This paper describes a microfluidic approach to perform multiplexed nanoliter-scale experiments by combining a sample with multiple different reagents, each at multiple mixing ratios. This approach employs a user-loaded, equipment-free SlipChip. The mixing ratios, characterized by diluting a fluorescent dye, could be controlled by the volume of each of the combined wells. The SlipChip design was validated on an {approx}12 nL scale by screening the conditions for crystallization of glutaryl-CoA dehydrogenase from Burkholderia pseudomallei against 48 different reagents; each reagent was tested at 11 different mixing ratios, for a total of 528 crystallization trials. The total consumption of the protein sample was {approx}10 {micro}L. Conditions for crystallization were successfully identified. The crystallization experiments were successfully scaled up in well plates using the conditions identified in the SlipChip. Crystals were characterized by X-ray diffraction and provided a protein structure in a different space group and at a higher resolution than the structure obtained by conventional methods. In this work, this user-loaded SlipChip has been shown to reliably handle fluids of diverse physicochemical properties, such as viscosities and surface tensions. Quantitative measurements of fluorescent intensities and high-resolution imaging were straighforward to perform in these glass SlipChips. Surface chemistry was controlled using fluorinated lubricating fluid, analogous to the fluorinated carrier fluid used in plug-based crystallization. Thus, we expect this approach to be valuable in a number of areas beyond protein crystallization, especially those areas where droplet-based microfluidic systems have demonstrated successes, including measurements of enzyme kinetics and blood coagulation, cell-based assays, and chemical reactions.

59 BASIC BIOLOGICAL SCIENCES↗

Impact of plug-in hybrid electric vehicles on power systems with demand response and wind power.

This paper uses a new unit commitment model which can simulate the interactions among plug-in hybrid electric vehicles (PHEVs), wind power, and demand response (DR). Four PHEV charging scenarios are simulated for the Illinois power system: (1) unconstrained charging, (2) 3-hour delayed constrained charging, (3) smart charging, and (4) smart charging with DR. The PHEV charging is assumed to be optimally controlled by the system operator in the latter two scenarios, along with load shifting and shaving enabled by DR programs. The simulation results show that optimally dispatching the PHEV charging load can significantly reduce the total operating cost of the system. With DR programs in place, the operating cost can be further reduced.

17 WIND ENERGY↗

Solid State Power Substation DC Node Optimization and Controller Hardware-In-The-Loop Demonstration

A solid state power substation (SSPS) node is a microgrid that integrates distributed energy resources and loads and injects/absorbs power to/from the SSPS distribution network. It is an essential building block of a futuristic distribution grid network. This paper presents the development and demonstration of optimization use cases of a SSPS DC node. By adopting multi-layer hierarchical control architecture and developing automatic device identification and dynamic optimization formulation algorithms, the SSPS DC node can perform plug-and-play resource integration and seamless transition of the optimized node operation under on and off grid condition without sophisticated algorithms, control mode changes, and user interactions. Four optimization use cases including economic dispatches with price signal changes, a sudden PV power drop, and a single directional meter and its associated costs with sending power back to the grid, and resiliency under a grid inverter trip condition were demonstrated through the real-time controller hardware-in-the-loop simulation.