Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plasma measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Optimal choice of multiple line-of-sight measurements determining plasma hotspot velocity at the National Ignition Facility

The measurement of plasma hotspot velocity provides an important diagnostic of implosion performance for inertial confinement fusion experiments at the National Ignition Facility. The shift of the fusion product neutron mean kinetic energy as measured along multiple line-of-sight time-of-flight spectrometers provides velocity vector components from which the hotspot velocity is inferred. Multiple measurements improve the hotspot velocity inference; however, practical considerations of available space, operational overhead, and instrumentation costs limit the number of possible line-of-sight measurements. Here, we propose a solution to this classical “experiment design” problem that optimizes the precision of the velocity inference for a limited number of measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-voltage space-plasma interactions measured on the PASP Plus test arrays

The Photovoltaic Array Space Power Plus Diagnostics (PASP Plus) experiment was developed by the Air Force's Phillips Laboratory with support from NASA's Lewis Research Center. It was launched on the Advanced Photovoltaic and Electronics EXperiments (APEX) satellite on August 3, 1994 into a 70 degree inclination, 363 km by 2550 km elliptical orbit. This orbit allows the investigation of space plasma effects on high-voltage operation (leakage current at positive voltages and arcing at negative voltages) in the perigee region. PASP Plus is testing twelve solar arrays. There are four planar Si arrays: an old standard type (used as a reference), the large-cell Space Station Freedom (SSF) array, a thin 'APSA' array, and an amorphous Si array. Next are three GaAs on Ge planar arrays and three new material planar arrays, including InP and two multijunction types. Finally, there are two concentrator arrays: a reflective-focusing Mini-Cassegrainian and a Fresnel-lens focusing Mini-Dome. PASP Plus's diagnostic sensors include: Langmuir probe to measure plasma density, an electrostatic analyzer (ESA) to measure the 30 eV to 30 KeV electron/ion spectra and determine vehicle negative potential during positive biasing, and a transient pulse monitor (TPM) to characterize the arcs that occur during the negative biasing. Through positive biasing of its test arrays, PASP Plus investigated the snapover phenomenon, which took place over the range of +100 to +300 V. It was found that array configurations where the interconnects are shielded from the space plasma (i.e., the concentrators or arrays with 'wrap-through' connectors) have lower leakage current. The concentrators exhibited negligible leakage current over the whole range up to +500 V. In the case of two similar GaAs on Ge arrays, the one with 'wrap-through' connectors had lower leakage current than the one with conventional interconnects. Through negative biasing, PASP Plus investigated the arcing rates of its test arrays. The standard Si array, with its old construction (exposed rough-surface interconnects), arced significantly over a wide voltage and plasma-density range. The other arrays arced at very low rates, mostly at voltages greater than -350 V and plasma densities near or greater than 10(exp 5)/cm(exp -3). AS expected according to theory, arcing was more prevalent when array temperatures were cold (based on biasing in eclipse).

Guidice, Donald A.↗

Single-shot spatiotemporal plasma density measurements with a chirped probe pulse

In this work, we present the development and demonstration of a diagnostic for the measurement of the spatial and temporal evolution of plasma density in a single shot. Single-shot Advanced Plasma Probe HolographIc REconstruction (SAPPHIRE) utilizes a chirped probe pulse, a diffractive optical element, a self-referenced interferometer, and an interference bandpass filter to achieve high-fidelity electron density measurements suitable for underdense plasmas that exhibit cylindrical symmetry. The method overcomes limitations in conventional diagnostics, such as reliance on shot-to-shot reproducibility, while capturing plasma dynamics on picosecond timescales with micron-level spatial resolution. The capabilities of SAPPHIRE are demonstrated through measurements of laser-driven plasma channels in helium–nitrogen gas jets. SAPPHIRE demonstrates the formation and expansion of plasma channels in a single shot and the propagation of supersonic ionization fronts while revealing shot-to-shot variations in the plasma profiles. Experimental results are validated against theoretical models and scaling laws, underscoring the robustness and accuracy of this technique. By enabling ultrafast, high-resolution plasma diagnostics in a single exposure, SAPPHIRE represents a transformative advancement in plasma measurement technology.

Grace, Elizabeth S. [Lawrence Livermore National L↗

A Hybrid Electrostatic Retarding Potential Analyzer for the Measurement of Plasmas at Extremely High Energy Resolution

Many space plasmas (especially electrons generated in planetary ionospheres) exhibit fine-detailed structures that are challenging to fully resolve with the energy resolution of typical space plasma analyzers (10% → 20%). While analyzers with higher resolution have flown, generally this comes at the expense of sensitivity and temporal resolution. We present a new technique for measuring plasmas with extremely high energy resolution through the combination of a top-hat Electrostatic Analyzer (ESA) followed by an internally mounted Retarding Potential Analyzer (RPA). When high resolutions are not required, the RPA is grounded, and the instrument may operate as a typical general-purpose plasma analyzer using its ESA alone. We also describe how such an instrument may use its RPA to remotely vary the geometric factor (sensitivity) of a top hat analyzer, as was performed on the New Horizons Solar Wind at Pluto and MAVEN SupraThermal and Thermal Ion Composition instruments. Finally, we present results from laboratory testing of our prototype, showing that this technique may be used to construct an instrument with 1.6% energy resolution, constant over all energies and angles.

Collinson, Glyn A.↗

Time-resolved interferometric measurements of plasma density evolution in laser-driven capacitor-coil targets

Laser-driven capacitor-coil targets provide a compact platform for generating strong magnetic fields and are widely used in magnetized high-energy-density (HED) plasma experiments. In addition to magnetic-field generation, these targets also produce plasma in the coil region, which can influence the subject physical processes and interact with secondary targets or external plasmas in their applications. However, direct, time-resolved measurements of the plasma density surrounding the coil remain limited. Here, we report interferometric measurements of the plasma density evolution in laser-driven capacitor-coil targets irradiated by the University of Osaka LFEX laser. Two-dimensional electron density maps reveal two distinct plasma sources loading the coil region: plasma generated in the coil itself and plasma produced by laser ablation of the target plates. These results provide quantitative information on plasma loading and evolution in capacitor-coil targets and are directly relevant to the design and modeling of magnetized HED plasma experiments.

Zhang, Yang [Princeton University, NJ (United Stat↗

Multi-physics modeling of tungsten collector probe samples during the WEST C4 He campaign

Abstract We describe the results of a multi-scale, multi-physics modeling assessment of SOLPS-ITER, hPIC2, RustBCA and Xolotl, in which five single-crystal tungsten (W) samples were placed in a reciprocating collector probe and exposed to helium (He) plasma in the WEST fusion device. In our models, we considered a pure (100 %) He plasma, as well as one with oxygen (O) present (95% He 5% O) corresponding to the impurity concentration estimated during the C4 He campaign in WEST. Our SOLPS simulations approximately match experimental reciprocating Langmuir probe plasma measurements of plasma density and temperature. Using these plasma parameters as input, hPIC2 and RustBCA predict that the presence of oxygen impurities lead to a 15%–20% decrease in ion and heat fluxes to the surface, and an order of magnitude higher sputtering yields (compared with a pure He plasma). Xolotl predictions for the response of tungsten to plasma surface interactions (PSIs) agree with experimental LAMS analysis, and indicate large near-surface He concentrations, which quickly decay with depth. Our model also shows an increasing role of erosion—in removing the near-surface He—with time. Overall, slightly higher retention is predicted for tungsten exposed to a pure He plasma, with the largest differences in the near-surface gas content caused by the large oxygen-induced erosion. This highlights the important role that impurities play in PSI. Therefore, future work will focus on providing a fully self-consistent description of oxygen (and oxides, etc.) in our models, through multi-species implementation in GITR and inclusion of oxygen and tungsten oxide formation in Xolotl.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Carbon dioxide as working gas for laboratory plasmas

Measurements with a RF probe, retarding potential analyzer and mass spectrometer in a laboratory plasma tank were performed using the gases CO2, N2, A and He in order to compare their properties as working gases for laboratory plasma production. The overall result of that CO2 leads to higher plasma densities at lower neutral-gas pressures as well as to a larger Maxwellian component of the electron population, while the electron temperature is lower than that when N2, A and He are used.

Kist, R.↗

Measurements of plasma density and turbulence near the shuttle orbiter

In August 1985 the University of Iowa's Plasma Diagnostics Package was used in the Spacelab 2 mission to study the plasma environment near the shuttle orbiter. Measurements of the plasma density and the percentage density fluctuations yielded information about the structure of the orbiter's wake. These data appear to be in general agreement with previous shuttle results and with laboratory observations of plasma flow-body interactions.

Tribble, A.↗

Comparison of plasma wave measurements in the bow shocks at Earth, Jupiter, Saturn, Uranus and Neptune

Plasma wave measurements from the Voyager 2 crossing of Neptune's bow shock are presented and compared with measurements from the bow shocks of Earth, Jupiter, Saturn, and Uranus. The wave amplitudes above 0.01fp, when normalized to the solar wind ion thermal energy density at each planet, are significantly higher at the outer planets than at Earth. Despite the differences in amplitude, the shock spectra of all the planets can be fitted to curves of similar form in this frequency range. The total normalized electric field energy densities exhibit an exponential dependence on ion thermal Mach number, Magnetosheath wave energies are comparable at all of the planets when normalized to the downstream plasma pressure.

Moses, S. L.↗

Comparative In Situ Measurements of Plasma Instabilities in the Equatorial and Auroral Electrojets

This presentation provides a comparison of in situ measurements of plasma instabilities gathered by rocket-borne probes in the equatorial and auroral electrojets. Specifically, using detailed measurements of the DC electric fields, current density, and plasma number density within the unstable daytime equatorial electrojet from Brazil (Guara Campaign) and in the auroral electrojet from Sweden (ERRIS Campaign), we present comparative observations and general conclusions regarding the observed physical properties of Farley-Buneman two-stream waves and large scale, gradient drift waves. The two stream observations reveal coherent-like waves propagating near the E x B direction but at reduced speeds (nearer to the presumed acoustic velocity) with wavelengths of approximately 5-10m in both the equatorial and auroral electrojet, as measured using the spaced-receiver technique. The auroral electrojet data generally shows extensions to shorter wavelengths, in concert with the fact that these waves are driven harder. With respect to gradient-drift driven waves, observations of this instability are much more pronounced in the equatorial electrojet, given the more favorable geometry for growth provided by the vertical gradient and horizontal magnetic field lines. We present new analysis of Guara rocket observations of electric field and plasma density data that reveal considerable structuring in the middle and lower portion of the electrojet (90-105 km) where the ambient plasma density gradient is unstable. Although the electric field amplitudes are largest (approximately 10-15 mV/m) in the zonal direction, considerable structure (approximately 5-10 mV/m) is also observed in the vertical electric field component as well, implying that the dominant large scale waves involve significant vertical interaction and coupling within the narrow altitude range where they are observed. Furthermore, a detailed examination of the phase of the waveforms show that on some, but not all occasions, locally enhanced eastward fields are associated with locally enhanced upwards (polarization) electric fields. The measurements are discussed in terms of theories involving the non-linear evolution and structuring of plasma waves.

Pfaff, Robert F.↗

Spatially resolved measurements of plasma ion velocity distributions in a dipole magnetic field

The equilibrium flows of a plasma discharge in a dipole magnetic field are a topic of interest in low temperature plasma physics. Experimentalists typically rely on probe-based and line-integrated diagnostic techniques in these environments to describe plasma behavior. Presented here are measurements of argon ion dynamics with laser induced fluorescence techniques to provide insight into plasma dynamics in dipole magnetic fields with nonperturbative, spatially localized measurements. Simulation results from a Lagrangian approach to track particle orbits are compared to measured density profiles and provide evidence to support the mechanism distinguishing experimental configurations is the initial approach of particles. Applying a negative DC bias to the magnet induces strong E×B flows around the magnet, even exceeding the ion acoustic speed as measured far from the magnet. A strong enough bias also produces two distinct ion populations and provides a method for controlling the density gradient on the equator.

McLaughlin, Jacob W. (ORCID:0000000152661888)↗

Magnetogasdynamic heat transfer to a hemispherical body in a supersonic argon plasma.

Measurements of the heat transfer to a hemispherical body in a Mach 4.6, low density, argon plasma are reported. The experiments demonstrated that local wall currents affected the heat flux to the electrically conducting surface, both without and with internally applied magnetic fields. Such currents were induced by a nonuniform shock-layer plasma potential; but with applied fields, Hall currents dominated. Magnetic fields significantly increased the stagnation-region heat flux while causing a reduction over the remainder of the hemisphere. For an electrically nonconducting surface, the local heat flux was reduced, and magnetic fields insignificantly affected the heat flux. Analytical treatments indicate that joule and radiation heating were negligible.

Nowak, R. J.↗

Inductive Measurement of Plasma Jet Electrical Conductivity

An inductive probing scheme, originally developed for shock tube studies, has been adapted to measure explosive plasma jet conductivities. In this method, the perturbation of an applied magnetic field by a plasma jet induces a voltage in a search coil, which, in turn, can be used to infer electrical conductivity through the inversion of a Fredholm integral equation of the first kind. A 1-inch diameter probe was designed and constructed, and calibration was accomplished by firing an aluminum slug through the probe using a light-gas gun. Exploratory laboratory experiments were carried out using plasma jets expelled from 15-gram high explosive shaped charges. Measured conductivities were in the range of 3 kS/m for unseeded octol charges and 20 kS/m for seeded octol charges containing 2% potassium carbonate by mass.

Turner, Matthew W.↗