Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plasma diagnostic techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Demonstration of a laser-driven, narrow spectral bandwidth x-ray source for collective x-ray scattering experiments

X-ray Thomson scattering (XRTS) is a powerful diagnostic technique that involves an x-ray source interacting with a dense plasma sample, resulting in a spectrum of elastically and inelastically scattered x-rays. Depending on the plasma conditions, one can measure a range of parameters from the resulting spectrum, including plasma temperature, electron density, and ionization state. To achieve sensitivity to collective electron oscillations, XRTS measurements require limited momentum transfer where the spectral separation of elastic and inelastic scattering is small. Such measurements require an x-ray probe source with a narrow bandwidth in order to reduce the spectral overlap between scattering contributions, allowing for the different features to be more precisely deconvolved. In this investigation, we discuss the theory behind how the bandwidth for a common XRTS probe, Zn He-α emission at 9 keV, can be reduced using a Cu K-edge filter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of tokamak vertical stability control based on non-inductive Faraday-effect polarimetry measurements

Long-pulse or steady-state fusion reactors are envisioned to control vertical stability based on non-inductive measurements, i.e. that do not rely on temporal change of magnetic field. For the first time, vertical stability control using non-inductive Faraday-effect polarimetry measurements has been demonstrated. The Radial Interferometer-Polarimeter system on DIII-D is capable of microsecond resolution and was used to absolutely determine the vertical position of the plasma magnetic axis Z 0 . A vertical stability controller was developed to robustly stabilize diverted plasmas using Faraday-based measurements. The system was able to stabilize against vertical displacement events with growth rates up to 350 s -1 in elongated and elliptical plasma shapes, and instabilities with even higher growth rates are likely to be controllable with further improvements to controller tuning. Tests show that the Faraday-based controller remains effective and is capable of recovering from loss of control even when the plasma vertical position is far from the region where the linear model used to calculate Z 0 is most valid. Faraday control has also been activated during plasma ramp-up, demonstrating the robustness of the technique to larger systematic diagnostic uncertainty at low electron density.

Faraday-effect polarimetry↗

Understanding Coronal Heating with Emission Measure Distributions

It is widely believed that the cross-field spatial scale of coronal heating is small, so that the fundamental plasma structures (loop strands) are spatially unresolved. We therefore must appeal to diagnostic techniques that are not strongly affected by spatial averaging. One valuable observable is the emission measure distribution, EM(T), which indicates how much material is present at each temperature. Using data from the Extreme-ultraviolet Imaging Spectrograph on the Hinode mission, we have determined emission measure distributions in the cores of two active regions. The distributions have power law slopes of approximately 2.4 coolward of the peak. We compare these slopes, as well as the amount of emission measure at very high temperature, with the predictions of a series of models. The models assume impulsive heating (nanoflares) in unresolved strands and take full account of non equilibrium ionization. A variety of nanoflare properties and initial conditions are considered. We also comment on the selection of spectral lines for upcoming missions like Solar Orbiter.

Klimchik, James A.↗

Multimodal super-resolution: discovering hidden physics and its application to fusion plasmas

Understanding complex physical systems often requires integrating data from multiple diagnostics, each with limited resolution or coverage. We present a machine learning framework that reconstructs synthetic high-temporal-resolution data for a target diagnostic using information from other diagnostics, without direct target measurements during the inference. This multimodal super-resolution technique improves diagnostic robustness and enables monitoring even in case of measurement failures or degradation. Applied to fusion plasmas, our method targets edge-localized modes (ELMs), which can damage plasma-facing materials. By reconstructing super-resolution Thomson Scattering data from complementary diagnostics, we uncover fine-scale plasma dynamics and validate the role of resonant magnetic perturbations (RMPs) in ELM suppression through magnetic island formation. The approach provides new observation supporting the plasma profile flattening due to these islands. Our results demonstrate the framework’s ability to generate high-fidelity synthetic diagnostics, offering a powerful tool for ELM control development in future reactors like ITER. The approach is broadly transferable to other domains facing sparse, incomplete, or degraded diagnostic data, opening new avenues for discovery.

Jalalvand, Azarakhsh [Princeton Univ., NJ (United ↗

Implementation of high-speed data acquisition at DIII-D

Research at the DIII-D National Fusion Facility in San Diego focuses on short pulse plasma discharges that specialize on various shaping profiles. High-speed data collection is a critical component for the operation of many of DIII-D’s diagnostics and is fundamental for capturing high-resolution data used in experimental data analysis. Differing techniques enable the plasma control system (PCS) to perform complex real-time feedback control on microsecond time scales. This work presents a comprehensive overview of data acquisition, focusing on the hardware and software used in reliable data acquisition at DIII-D. The robust nature of the data acquisition system allows for various techniques to coexist seamlessly. However, as modern systems capable of nanosecond resolution become more common, existing architectures will need to be modified. Here, by addressing the key challenges of high-speed data acquisition, DIII-D is able to provide real-time data used in plasma operation and has the ability to acquire high fidelity data needed for future experimental fusion reactors, such as ITER.

Control↗

X-ray absorption spectroscopy measurements of radiatively ionized argon gas

X-ray absorption spectroscopy is a diagnostic tool that can characterize the temperature and ionization state of a plasma. This technique requires experiments to characterize the platform, careful data calibration, and comparison with atomic models to understand the plasma parameters. We performed ionizing radiation wave experiments at the OMEGA Laser Facility that used an ∼ 80 eV X-ray source to heat an Argon (Ar) gas cell at fill pressures of 3 atm. To diagnose the Ar plasma, we used a capsule backlighter offset 10 mm from the gas cell, to produce X-rays that were absorbed by the ionized Ar gas. The absorption analysis was calibrated using the significant line structure in the backlighter spectrum, which served as independent energy fiducials enabling definitive measurements of a 50-eV shift in the energy of the Ar K-edge due to ionization. We compare the measured absorption spectra to two independent atomic models, PrismSPECT and SCRAM, and show that the observed K-edge shift in the heated gas is consistent with ionization up to Ar 4+ and temperatures of 10 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laboratory plasma resonances

Stable plasma resonance behavior, calculating small signal and nonlinear responses for theory verification and diagnostic techniques

Crawford, F. W.↗

X-ray line ratios from helium-like ions - Updated theory and SMM flare observations

The potential which the conduction of measurements of the three principal lines emitted from helium-like ions has for the determination of plasma electron density was initially pointed out by Gabriel and Jordan (1969). The diagnostic technique is based on the fact that the ratio, R, of the intensity of a forbidden line to the intensity of an intercombination line decreases as electron density increases due to collisional excitation of levels. In the present investigation a further refinement of this procedure is provided by specifically calculating the effects of cascades from levels with principal quantum numbers up to n=6. Two improved spectrometers recently placed in operation include the SOLEX instrument on the satellite P78-1 and the X-ray Polychromator (XRP) instrument on the NASA Solar Maximum Mission satellite. Measurements obtained with one of the spectrometers making up the XRP are presented, taking into account the emission from Ne IX ions.

Wolfson, C. J.↗

Application of the coded long-pulse technique to plasma line studies of the ionosphere

Recently, the coded long-pulse radar technique was tested at Arecibo Observatory, Puerto Rico using photoelectron-enhanced plasma lines in the daytime ionosphere. The technique immediately proved to be a powerful diagnostic tool for studying natural ionospheric phenomena. Our initial observations indicate that extremely accurate measurements of absolute electron density (0.01 to 0.03% error bars) can be achieved with an altitude resolution of 150 m and a temporal resolution of approx. 2 s. In addition, the technique provides information about electron density structure within a 150-m altitude cell and yields parameters from which the energy spectrum of suprathermal electrons (equal to or greater than 5 eV) can be deduced. Our earliest measurements are used to illustrate applications of the coded long-pulse technique to several aeronomic/ionsospheric areas of current interest. These include studies of neutral wave motions in the lower thermosphere, measurements of ion composition in the F(sub 1) region/upper ionosphere, and investigations of electron-gas thermal balance and photoelectron energy loss processes. The technique can be utilized to examine irregularity formation in the F region, probe electron acceleration processes in ionospheric modification experiments, verify the magnetic field dependence of Langmuir wave damping, and more generally test higher order corrections suggested for the Langmuir dispersion relation. It is anticipated that the latter tests will facilitate measurements of ionospheric currents.

Djuth, Frank T.↗

Study of the performance of antennas in magnetized plasmas

The antenna studies were performed in a large magnetized plasma source, a schematic drawing of which is shown. The plasma diagnostics consist of a 70 GHz (4 mm) microwave interferometer for density measurements and of various Langmuir probes for spatially resolved measurements of t sub e, n sub e and the shape of the electron distribution function. All diagnostic data are time-resolved by sample-and-hold techniques so as to yield information about the plasma build-up, the steady-state discharge, and the plasma decay in the afterglow. Whistler waves are excited and detected with various antennas which are inserted into the center of the plasma column through one axial and two orthogonal radial ports. The antennas were tested for their proper dipole response and then calibrated in a known field geometry in air. For the electric dipole, a parallel plate capacitor field was used; the magnetic loop is calibrated in the near-zone field of a long linear conductor of known radio frequency current distribution. Results are presented and discussed.

Stenzel, R. L.↗

A New Diagnostic Technique for the Solar Corona

Over the last 30-40 years spectroscopic observation of the EUV (extreme ultraviolet) line emission has proved invaluable as a diagnostic of the solar coronal plasma state. Line ratios have been used to determine electron density, electron temperature and ion flow velocity. In this paper, we present results obtained with a new measurement technique that uses spectroscopic observations of the white light corona to obtain the electron density, temperature, and flow velocity. A prototype instrument has been designed and built to obtain visible light spectra (3800-4300 A) with modest resolution. This instrument was used to obtain coronal observations during the June 2001 eclipse in Zambia. The data were corrected for sky and instrument transmission to derive the electron temperature and flow speed. Results from these measurements will be discussed.

Nelson, R.↗

Tomographic optical emission spectroscopy of an atmospheric pressure plasma jet and surface ionization waves on planar and structured surfaces

Here in this paper, an approach for 3D plasma structure diagnostics using tomographic optical emission spectroscopy (Tomo-OES) of a nanosecond pulsed atmospheric pressure plasma jet (APPJ) is presented. In contrast to the well-known Abel inversion, Tomo-OES does not require cylindrical symmetry to recover 3D distributions of plasma light emission. Instead, many 2D angular projections are measured with intensified cameras and the multiplicative algebraic reconstruction technique is used to recover the 3D distribution of light emission. This approach solves the line-of-sight integration problem inherent to optical diagnostics, allowing recovery of localized OES information within the plasma that can be used to better infer plasma parameters within complex plasma structures. Here, Tomo-OES was applied to investigate an APPJ operated with helium in ambient air and impinging on planar and structured dielectric surfaces. Surface charging caused the guided streamer from the APPJ to transition to a surface ionization wave (SIW) that propagated along the surface. The SIW experienced variable geometrical and electrical material properties as it propagated, leading to 3D configurations that were non-symmetric and spatially complex. Light emission from He, N$_2^+$, and N2 were imaged at ten angular projections and the respective time-resolved 3D emission distributions in the plasma were then reconstructed. The spatial resolution of each tomographic reconstruction was 7.4 µm and the temporal resolution was 5 ns, sufficient to observe the guided streamer and the effects of the structured surface on the SIW. Emission from He showed the core of the jet and emission from N$_2^+$ and N2 indicated effects of entrainment of ambient air. Penning ionization of N2 created a ring or outer layer of N$_2^+$ that spatially converged to form the 'plasma bullet' or spatially diverged across a surface as part of a SIW. The SIW entered trenches of size 150 µm, leading to decreases in plasma light emission in regions above the trenches. The plasma light emission was higher in some regions with trenches, possibly due to effects of field enhancement.

plasma interactions with complex surfaces↗

Upgrade of DIII-D radial interferometer–polarimeter for large bandwidth, low noise, and toroidal mode number measurements

Near ion-cyclotron frequency (f ci ) fluctuations, such as those originating from Global and Compressional Alfvén Eigenmodes (GAEs/CAEs), are expected to be present in future fusion reactors but are not well understood due to the limited availability of core measurements in present-day tokamaks. The measurement bandwidth of the Radial Interferometer–Polarimeter (RIP) diagnostic has been upgraded from 1 to 5 MHz to detect these fluctuations in DIII-D. RIP adopts the three-wave technique for simultaneous polarimetric and interferometric measurements. Solid-state microwave sources operating at 650 GHz are used as probe beams and provide 5 MHz bandwidth for both polarimetric and interferometric measurements. Bandwidths of related hardware, including mixer amplifier, signal cable, and digital phase demodulator, are increased correspondingly. Measurement noise is minimized by reducing the time delay between reference and probe signals to nanosecond level and employing correlation-based techniques. Using the upgraded diagnostic, CAE/GAE-like bursting fluctuations are observed in neutral-beam heated plasmas with toroidal magnetic field B φ ≈ 1 T. Current upgrades being undertaken would enable the evaluation of toroidal mode number for these modes. Furthermore, this work opens the possibility of better understanding near ion-cyclotron frequency fluctuations in fusion relevant plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proton radiography inversions with source extraction and comparison to mesh methods

In this article, proton radiography is a central diagnostic technique for measuring electromagnetic (EM) fields in high-energy-density, laser-produced plasmas. In this technique, protons traverse the plasma where they accumulate small EM deflections which lead to variations in the proton fluence pattern on a detector. Path-integrated EM fields can then be extracted from the fluence image through an inversion process. In this work, experiments of laser-driven foils were conducted on the OMEGA laser and magnetic field reconstructions were performed using both “fluence-based” techniques and high-fidelity “mesh-based” methods. We implement nonzero boundary conditions into the inversion and show their importance by comparing against mesh measurements. Good agreement between the methods is found only when nonzero boundary conditions are used. We also introduce an approach to determine the unperturbed proton source profile, which is a required input in fluence reconstruction algorithms. In this approach, a fluence inversion is embedded inside of a mesh region, which provides overconstrained magnetic boundary conditions. A source profile is then iteratively optimized to satisfy the boundary information. This method substantially enhances the accuracy in recovering EM fields. Lastly, we propose a scheme to quantify uncertainty in the final inversion that is introduced through errors in the source retrieval.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-Crystal X-Ray Spectropolarimeter

X-ray spectropolarimetry is a diagnostics technique suitable for measuring intense electron beams and strong magnetic fields in hot, dense plasmas. To increase the accuracy achievable, we investigated the possibility of measuring both orthogonal components of linear polarization simultaneously using a single crystal. We demonstrated experimentally for the first time that crystals with cubic symmetry can be used as polarizing beam splitters. We also found that the polarization-splitting planes in cubic crystals can be accessed in two crystal orientations, a property that can be used to decrease the clutter in polarized spectra. In parallel, we developed a ray-tracing code and are working to add the crystal reflectivity to instrument modeling codes, to help us interpret the spectra and to design spectroscopic and spectropolarimetric instruments. This work is motivated by the need to perform measurements of important quantities in difficult experimental conditions, such as the axial magnetic field at stagnation in magnetized liner inertial fusion loads.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a multi-detector, single line-of-sight, time-of-flight system to measure time-resolved neutron energy spectra

In the dynamic environment of burning, thermonuclear deuterium–tritium plasmas, diagnosing the time-resolved neutron energy spectrum is of critical importance. Strategies exist for this diagnosis in magnetic confinement fusion plasmas, which presently have a lifetime of ~10 12 longer than inertial confinement fusion (ICF) plasmas. In this work, we present a novel concept for a simple, precise, and scale-able diagnostic to measure time-resolved neutron spectra in ICF plasmas. The concept leverages general tomographic reconstruction techniques adapted to time-of-flight parameter space, and then employs an updated Monte Carlo algorithm and National Ignition Facility-relevant constraints to reconstruct the time-evolving neutron energy spectrum. Reconstructed spectra of the primary 14.028 MeV n DT peak are in good agreement with the exact synthetic spectra. The technique is also used to reconstruct the time-evolving downscattered spectrum, although the present implementation shows significantly more error.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗