Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pixel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The Impact of Transition Edge Sensor Design on Achievable Performance Uniformity of Kilo-Pixel Arrays

Future astronomy missions using x-ray transition-edge sensor (TES) microcalorimeters, such as X-IFU on Athena, will require large arrays of 1000s of pixels fabricated on a single wafer. To wire out so many pixels the current array designs have pixels with different rotational orientations. Fabrication is done in multiple layers and so, dependent on method, there is potential for spatial misalignment between layers. Because of the variation of orientation of pixels, misalignment may not impact each pixel equally. This has the potential to degrade the achievable uniformity of performance across an array. How well aligned do different layers need to be? How does sensitivity to misalignment depend on choice of pixel design?

Wakeham, Nicholas↗

The Impact of Pixel Size on the Characterization of Deep Convective Clouds for Calibration

The NASA CERES project provides the scientific community the observed TOA SW and LW fluxes for climate monitoring and climate model validation. CERES utilizes hourly geostationary imager derived broadband fluxes, which rely on the channel radiances and associated cloud retrievals, to estimate the broadband fluxes between CERES observations. This requires stable imager visible channel calibration, which the CERES project verifies by utilizing deep convective clouds (DCC) as an invariant Earth target. GSICS, which is an international collaboration, is also evaluating the DCC invariant target calibration methodology to provide consistent calibration coefficients across geostationary imagers anchored to the Aqua-MODIS calibration reference. Tropical DCC are the brightest, coldest, most Lambertian, top of the atmosphere Earth targets. The DCC invariant target calibration methodology relies on a large ensemble of tropical DCC-identified pixel-level reflectances, which are histogrammed to find the mode reflectance of the probability density function (PDF). The imager stability is monitored by tracking the monthly DCC PDF mode reflectance over time. Radiometric scaling is accomplished by ratioing the GEO and VIIRS DCC mode reflectance values. The PDF shape and mode dependency on sensor pixel resolution, which varies among sensors, is unknown. This study will characterize the impact of pixel resolution on the DCC PDFs by aggregating Landsat 30-m pixel reflectances into various coarser pixel resolutions ranging from 100-m to 4-km, and comparing the corresponding PDF statistics. This analysis will assist in improving the uncertainty in a DCC-based intercalibration between instruments with different pixel resolutions.

Conor Haney↗

Consistent Pixel Resolution Characterization of Deep Convective Clouds for Calibration

The NASA CERES project provides global TOA shortwave and longwave fluxes for climate monitoring and validation that spans over 20 years. CERES utilizes broadband fluxes derived from geostationary (GEO) imagers to estimate broadband fluxes between the CERES observations. In order for these fluxes to be viable, the GEO imager calibration must be stable over time. One such calibration method used by CERES is to evaluate ensemble sets of deep convective clouds (DCC) as invariant targets (IT) over time. DCC targets can also provide radiometric scaling between sensors. An international collaboration through GSICS is also evaluating the DCC-IT calibration methodology to provide consistent calibration coefficients across geostationary sensors. Tropical DCC are the coldest, brightest, and most Lambertian TOA Earth targets identified using a window channel brightness temperature threshold. The DCC-IT technique involves a large ensemble of TOA pixel-level reflectances, which are binned into probability density functions (PDF). The PDF structure dependency on sensor pixel resolution, which can vary greatly among sensors, is not well known. This study will identify the impact of pixel resolution on the DCC PDFs by aggregating VIIRS and Landsat OLI/TIRS pixel resolutions into various coarser pixel resolutions and comparing the shape and statistics of the resulting PDFs. This study should assist in mitigating the pixel resolution dependency in the DCC-IT approach for providing scaling factors between sensors.

Conor Haney↗

A low-noise CMOS pixel direct charge sensor, Topmetal-II -

In this paper, we report the design and characterization of a CMOS pixel direct charge sensor, Topmetal-II-, fabricated in a standard 0.35 μm CMOS Integrated Circuit process. The sensor utilizes exposed metal patches on top of each pixel to directly collect charge. Each pixel contains a low-noise charge-sensitive preamplifier to establish the analog signal and a discriminator with tunable threshold to generate hits. The analog signal from each pixel is accessible through time-shared multiplexing over the entire array. Hits are read out digitally through a column-based priority logic structure. Tests show that the sensor achieved a <15e - analog noise and a 200e - minimum threshold for digital readout per pixel. The sensor is capable of detecting both electrons and ions drifting in gas. Lastly, these characteristics enable its use as the charge readout device in future Time Projection Chambers without gaseous gain mechanism, which has unique advantages in low background and low rate-density experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Attenuating Stereo Pixel-Locking via Affine Window Adaptation

For real-time stereo vision systems, the standard method for estimating sub-pixel stereo disparity given an initial integer disparity map involves fitting parabolas to a matching cost function aggregated over rectangular windows. This results in a phenomenon known as 'pixel-locking,' which produces artificially-peaked histograms of sub-pixel disparity. These peaks correspond to the introduction of erroneous ripples or waves in the 3D reconstruction of truly Rat surfaces. Since stereo vision is a common input modality for autonomous vehicles, these inaccuracies can pose a problem for safe, reliable navigation. This paper proposes a new method for sub-pixel stereo disparity estimation, based on ideas from Lucas-Kanade tracking and optical flow, which substantially reduces the pixel-locking effect. In addition, it has the ability to correct much larger initial disparity errors than previous approaches and is more general as it applies not only to the ground plane.

pixel locking effect↗

Mapping Electrical Crosstalk in Pixelated Sensor Arrays

Electronic coupling effects such as Inter-Pixel Capacitance (IPC) affect the quantitative interpretation of image data from CMOS, hybrid visible and infrared imagers alike. Existing methods of characterizing IPC do not provide a map of the spatial variation of IPC over all pixels. We demonstrate a deterministic method that provides a direct quantitative map of the crosstalk across an imager. The approach requires only the ability to reset single pixels to an arbitrary voltage, different from the rest of the imager. No illumination source is required. Mapping IPC independently for each pixel is also made practical by the greater S/N ratio achievable for an electrical stimulus than for an optical stimulus, which is subject to both Poisson statistics and diffusion effects of photo-generated charge. The data we present illustrates a more complex picture of IPC in Teledyne HgCdTe and HyViSi focal plane arrays than is presently understood, including the presence of a newly discovered, long range IPC in the HyViSi FPA that extends tens of pixels in distance, likely stemming from extended field effects in the fully depleted substrate. The sensitivity of the measurement approach has been shown to be good enough to distinguish spatial structure in IPC of the order of 0.1%.

focal plane array↗

Pixel Detector Developments for Tracker Upgrades of the High Luminosity LHC

This paper reports on the INFN (Istituto Nazionale di Fisica Nucleare, Italy) research activity in collaboration with FBK foundry, which is aiming at the development of new pixel detectors for the LHC Phase-2 upgrades. The R&D covers both planar pixel devices and 3D detectors built using columnar technology. All sensors are low thickness n-in-p type, as this is the general direction envisaged for the High Luminosity LHC pixel detector upgrades. Hybrid modules with 100 $\upmu $ m and 130 $\upmu $ m active thickness, connected to the PSI46dig readout chip, have been tested on beam test experiments. Selected preliminary results from test beams are described for both planar and 3D devices. The results on the 3D pixel sensors before irradiation are very satisfactory and support the conclusion that columnar devices are very good candidates for the inner layers of the upgrade pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automatic Organ Segmentation for CT Scans Based on Super-Pixel and Convolutional Neural Networks

Accurate segmentation of specific organ from computed tomography (CT) scans is a basic and crucial task for accurate diagnosis and treatment. To avoid time-consuming manual optimization and to help physicians distinguish diseases, an automatic organ segmentation framework is presented. The framework utilized convolution neural networks (CNN) to classify pixels. To reduce the redundant inputs, the simple linear iterative clustering (SLIC) of super-pixels and the support vector machine (SVM) classifier are introduced. To establish the perfect boundary of organs in one-pixel-level, the pixels need to be classified step-by-step. First, the SLIC is used to cut an image into grids and extract respective digital signatures. Next, the signature is classified by the SVM, and the rough edges are acquired. Finally, a precise boundary is obtained by the CNN, which is based on patches around each pixel-point. The framework is applied to abdominal CT scans of livers and high-resolution computed tomography (HRCT) scans of lungs. The experimental CT scans are derived from two public datasets (Sliver 07 and a Chinese local dataset). Experimental results show that the proposed method can precisely and efficiently detect the organs. This method consumes 38 s/slice for liver segmentation. The Dice coefficient of the liver segmentation results reaches to 97.43%. For lung segmentation, the Dice coefficient is 97.93%. This finding demonstrates that the proposed framework is a favorable method for lung segmentation of HRCT scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The pixel tracking telescope at the Fermilab Test Beam Facility

An all silicon pixel telescope has been assembled and used at the Fermilab Test Beam Facility (FTBF) since 2009 to provide precise tracking information for different test beam experiments with a wide range of Detectors Under Test (DUTs) requiring high resolution measurement of the track impact point. The telescope is based on CMS pixel modules left over from the CMS forward pixel production. Eight planes are arranged to achieve a resolution of less than 8 μm on the 120 GeV proton beam transverse coordinate at the DUT position. In order to achieve such resolution with 100 × 150 μm 2 pixel cells, the planes were tilted to 25 degrees to maximize charge sharing between pixels. Crucial for obtaining this performance is the alignment software, called Monicelli, specifically designed and optimized for this system. This paper will describe the telescope hardware, the data acquisition system and the alignment software constituting this particle tracking system for test beam users.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unsupervised Learning for Improved Gamma-Ray Spectrometry in Pixelated Cadmium Zinc Telluride (CZT) Detectors

Machine learning has been found to be ubiquitously useful across many industries, presenting an opportunity to improve radiation detection performance using data-driven algorithms. Improved detector resolution can aid in the detection, identification, and quantification of radionuclides. Here, in this work, a novel, data-driven, unsupervised learning approach is developed to improve detector spectral characteristics by learning, and subsequently rejecting, poorly performing regions of the pixelated detector. Feature engineering is used to fit individual characteristic photo peaks to a Doniach lineshape with a linear background model. Then, principal component analysis is used to learn a lower-dimension latent space representation of each photo peak where the pixels are clustered, and subsequently ranked, based on the cluster mean distance to an optimal point. Pixels within the worst cluster(s) are rejected to improve the full-width at half-maximum (FWHM) by 10% to 15% (relative to the bulk detector) at 50% net efficiency when applied to training data obtained from measurements of a 100 μCi 154 Eu source using a H3D M400i pixelated cadmium zinc telluride detector. These results compare well with, but do not outperform, a greedy algorithm that accumulates pixels in order of FWHM from lowest to highest used as a benchmark. In the future, this approach can be extended to include the detector energy and angular response. Finally, the model is applied to newly seen natural and enriched uranium spectra relevant for nuclear safeguards applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and correction of charge-induced pixel shifts in DECam

Interaction of charges in CCDs with the already accumulated charge distribution causes both a flux dependence of the point-spread function (an increase of observed size with flux, also known as the brighter/fatter effect) and pixel-to-pixel correlations of the Poissonian noise in flat fields. We describe these effects in the Dark Energy Camera (DECam) with charge dependent shifts of effective pixel borders, i.e. the Antilogus et al. (2014) model, which we fit to measurements of flat-field Poissonian noise correlations. The latter fall off approximately as a power-law r -2.5 with pixel separation r, are isotropic except for an asymmetry in the direct neighbors along rows and columns, are stable in time, and are weakly dependent on wavelength. They show variations from chip to chip at the 20% level that correlate with the silicon resistivity. The charge shifts predicted by the model cause biased shape measurements, primarily due to their effect on bright stars, at levels exceeding weak lensing science requirements. We measure the flux dependence of star images and show that the effect can be mitigated by applying the reverse charge shifts at the pixel level during image processing. Differences in stellar size, however, remain significant due to residuals at larger distance from the centroid.

79 ASTRONOMY AND ASTROPHYSICS↗

The DAQ and control system for the CMS Phase-1 pixel detector upgrade

In 2017 a new pixel detector was installed in the CMS detector. This so-called Phase-1 pixel detector features four barrel layers in the central region and three disks per end in the forward regions. The upgraded pixel detector requires an upgraded data acquisition (DAQ) system to accept a new data format and larger event sizes. A new DAQ and control system has been developed based on a combination of custom and commercial microTCA parts. Custom mezzanine cards on standard carrier cards provide a front-end driver for readout, and two types of front-end controller for configuration and the distribution of clock and trigger signals. Before the installation of the detector the DAQ system underwent a series of integration tests, including readout of the pilot pixel detector, which was constructed with prototype Phase-1 electronics and operated in CMS from 2015 to 2016, quality assurance of the CMS Phase-1 detector during its assembly, and testing with the CMS Central DAQ. This paper describes the Phase-1 pixel DAQ and control system, along with the integration tests and results. A description of the operational experience and performance in data taking is included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensor response and radiation damage effects for 3D pixels in the ATLAS IBL Detector

Pixel sensors in 3D technology equip the outer ends of the staves of the Insertable B Layer (IBL), the innermost layer of the ATLAS Pixel Detector, which was installed before the start of LHC Run 2 in 2015. 3D pixel sensors are expected to exhibit more tolerance to radiation damage and are the technology of choice for the innermost layer in the ATLAS tracker upgrade for the HL-LHC programme. While the LHC has delivered an integrated luminosity of ≃ 235 fb -1 since the start of Run 2, the 3D sensors have received a non-ionising energy deposition corresponding to a fluence of ≃ 8.5 × 10 14 1 MeV neutron-equivalent cm -2 averaged over the sensor area. This paper presents results of measurements of the 3D pixel sensors' response during Run 2 and the first two years of Run 3, with predictions of its evolution until the end of Run 3 in 2025. Data are compared with radiation damage simulations, based on detailed maps of the electric field in the Si substrate, at various fluence levels and bias voltage values. These results illustrate the potential of 3D technology for pixel applications in high-radiation

47 OTHER INSTRUMENTATION↗

First constraints on a pixelated universe in light of DESI observations

Pixelated dark energy is a string theory scenario with a quantum mechanically stable cosmological constant. The number of pixels that make up the universe slowly increases, manifesting as a time-dependent source of dark energy. DESI has recently reported evidence for dynamical dark energy that fits within this framework. In light of this, we perform the first cosmological analysis of the pixelated model. We find that the simplest model where the pixel growth rate is constant is able to accommodate the data, providing a marginally better fit than Λ⁢ CDM; and we show that models where the pixel growth rate is increasing and of order the Hubble constant today could provide better fits. Our analysis helps to clarify the features of UV constructions of dark energy necessary to accommodate the data.

dark energy↗

SU-F-J-177: A Novel Image Analysis Technique (center Pixel Method) to Quantify End-To-End Tests

Purpose: To implement a novel image analysis technique, “center pixel method”, to quantify end-to-end tests accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy was determined by delivering radiation to an end-to-end prototype phantom. The phantom was scanned with 0.8 mm slice thickness. The treatment isocenter was placed at the center of the phantom. In the treatment room, CBCT images of the phantom (kVp=77, mAs=1022, slice thickness 1 mm) were acquired to register to the reference CT images. 6D couch correction were applied based on the registration results. Electronic Portal Imaging Device (EPID)-based Winston Lutz (WL) tests were performed to quantify the errors of the targeting accuracy of the system at 15 combinations of gantry, collimator and couch positions. The images were analyzed using two different methods. a) The classic method. The deviation was calculated by measuring the radial distance between the center of the central BB and the full width at half maximum of the radiation field. b) The center pixel method. Since the imager projection offset from the treatment isocenter was known from the IsoCal calibration, the deviation was determined between the center of the BB and the central pixel of the imager panel. Results: Using the automatic registration method to localize the phantom and the classic method of measuring the deviation of the BB center, the mean and standard deviation of the radial distance was 0.44 ± 0.25, 0.47 ± 0.26, and 0.43 ± 0.13 mm for the jaw, MLC and cone defined field sizes respectively. When the center pixel method was used, the mean and standard deviation was 0.32 ± 0.18, 0.32 ± 0.17, and 0.32 ± 0.19 mm respectively. Conclusion: Our results demonstrated that the center pixel method accurately analyzes the WL images to evaluate the targeting accuracy of the radiosurgery system. The work was supported by a Research Scholar Grant, RSG-15-137-01-CCE from the American Cancer Society.

60 APPLIED LIFE SCIENCES↗

RiverPIXELS: paired Landsat images and expert-labeled sediment and water pixels for a selection of rivers v1.0

RiverPIXELS contains GeoTIFFs of hand-labeled water and sediment pixels from Landsat images containing rivers. Each of the 104 labeled patches contains 256 x 256 Landsat pixels (30 meter resolution). Our aim in releasing RiverPIXELS is to provide an "off-the-shelf" training and testing dataset for building machine-learned models to automatically identify rivers from multispectral imagery. While a number of trained models and/or surface water products already exist, RiverPIXELS aims for pixel-level accuracy in order to precisely identify river boundaries in particular. Our selection of rivers is heavily Arctic, but we include tropical and temperate rivers as well. Patches are provided for the Colville (7), Indigirka (6), Kolyma (4), Ucayali (54), Waitaki (21), and Yana (12) Rivers. For each patch, all surface water pixels are labeled (1) and all in-channel sediment pixels are labeled (2). Sediments not in-channel are considered part of the land (0) class. RiverPIXELS also includes paired surface water data from the Global Surface Water dataset that may be useful as additional features in machine learning models. Each patch therefore contains four aligned GeoTIFFs: labeled, landsat, gswmo, and gswocc.

54 ENVIRONMENTAL SCIENCES↗

High Energy Micron Scale Pixel Hybrid Detector

The objective of this technology development project has been to fabricate and characterize a new X-ray area image sensor innovation designed for high efficiency detection and imaging of hard X-rays (>20 KeV) with micron scale pixel resolution. A key technology component consists of a monolithic hybrid X-ray detector built by layering an amorphous Selenium X-ray photoconductor film directly deposited on a small pitch (7.8μm) CMOS active pixel readout array. A specific goal of this work is to provide a new detector tool to researchers working with synchrotron light sources, to extend the depth of exploration into nanoscale structures, and do so cost effectively. Early generation X-ray imaging detector tools fail to provide adequate resolving power and efficiency at high energies and our innovation provides a solution. A majority of proposed phase I tasks were completed. Those tasks included, in collaboration with KA Imaging, successful fabrication of specified a-Se layers on a 1Mpixel CMOS readout array to create the direct hybrid X-ray imaging array, packaging of the imaging array, assembly of electronics into a shielded detector box, loading user interface software for camera control and image capture, and performing initial (no X-ray) detector evaluation at Farrier Microengineering facilities. After initial tests, extensive testing using the X-ray beam line 1-BM source at Argonne National Laboratory Advanced Photon Source(ANL-APS) was performed. Imaging performance studies were conducted at multiple X-ray beam energies. Studies included X-ray response vs. X-ray energy, vs. applied detector field strength (HV), response linearity vs. integration time, MTF vs. beam energy, image lag measurements, and micron scale resolution pattern target imaging. This high energy micron scale X-ray detection technology is a first of a kind to be evaluated at the ANL-APS and is supported by Dr. Antonino Miceli, head of the detector physics group. Accomplishments include the first successful demonstration of a 1Mpix amorphous Selenium on CMOS readout direct hybrid X-ray imaging detector at a DOE sponsored National Laboratory. Modeled performance predictions were confirmed, proving micron scale resolution as well as an order of magnitude increase in conversion efficiency over conventional scintillator detector performance. A discovery of evidence of propagation-based phase contrast edge enhancement was unplanned and will be exploited in future experiments. This phase 1 technology demonstration verifies the efficacy of proposed high energy micron scale pixel X-ray hybrid a-Se imaging array products. The new detector products will cost effectively replace early generation detector technologies that currently fail to address increasing demand for tools to study nano structures and physical processes at high X-ray energies above 20keV. For example, current systems for transmission X-ray microscopy have low efficiency and available large pixel (~55µm) direct detectors do not offer sufficient resolution for Bragg fringe imaging at high energies. This detector innovation will solve these inadequacies. The new detector technology will compete in a $50M scientific X-ray detector market, growing at 6%, and will benefit Microtomography(µCT), X-ray diffractometry (XRD), Coherent Diffraction Imaging (CDI) applications. One application specified by Dr. Miceli at ANL is the 3D reconstruction of compact crystals at high energies requires small pixel high efficiency X-ray detectors. Farrier Microengineering, working with colleagues at KA Imaging and the University of Waterloo, successfully achieved the critical objectives of the Phase I proposal. We have proven the technical feasibility of this innovation by building and successfully testing a 1Mpixel a-Se/CMOS hybrid direct X-ray imaging array. Our commercialization roadmap of detector products will be implemented during a phase II project. We will demonstrate a migration of the technology to larger detector array sizes, improved temporal performance with detector layer engineering, and improved environmental and operational stability. Manufacturability and cost effectiveness are key objectives and product designs will leverage current state of the art CMOS wafer fabrication quality and volume manufacturing economics.

36 MATERIALS SCIENCE↗

Equalizing the Pixel Response of the Imaging Photoelectric Polarimeter Onboard the IXPE Mission

The Gas Pixel Detector is a gas detector, sensitive to the polarization of X-rays, currently flying onboard the Imaging X-ray Polarimetry Explorer (IXPE)—the first observatory dedicated to X-ray polarimetry. It detects X-rays and their polarization by imaging the ionization tracks generated by photoelectrons absorbed in the sensitive volume, and then reconstructing the initial direction of the photoelectrons. The primary ionization charge is multiplied and ultimately collected on a finely pixellated ASIC specifically developed for X-ray polarimetry. The signal of individual pixels is processed independently and gain variations can be substantial, of the order of 20%. Such variations need to be equalized to correctly reconstruct the track shape, and therefore its polarization direction. The method to do such equalization is presented here and is based on the comparison between the mean charge of a pixel with respect to the other pixels for equivalent events. The method is shown to finely equalize the response of the detectors onboard IXPE, allowing a better track reconstruction and energy resolution, and can in principle be applied to any imaging detector based on tracks.

79 ASTRONOMY AND ASTROPHYSICS↗