Free jet phenomena in a 90 deg-sharp edge inlet geometry
The effects of free-jet phenomena, jetting, in a 90-deg-sharp-edge inlet tube are analyzed. Mass-limiting flow data and associated pressure profiles for tubes of 53, 64, 73 and 105 L/D with a 90 deg-sharp-edge or orifice-type inlet are compared to Borda-type inlet data to determine bounds of the free-jet phenomena. For smooth tubes the limits appear to be one-dimensional and dependent only on inlet stagnation conditions. The upper L/D boundary is related by stagnation characteristics and the lower bound appears to be saturation conditions at the inlet. It is noted that similar free-jet effects were found for fluid hydrogen indicating that fluid jetting might be common to all fluids flowing through 90 deg-sharp-edge inlet geometries.