Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “phenol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Determination of Phenols and Trimethylamine in Industrial Effluents

For regulatory purposes to control certain odorous compounds the analysis of phenols and trimethylamines in industrial effluents is necessary. The Bay Area Air Pollution Control District laboratory has been determining these gases by gas chromatographic techniques. The procedures for sample collection, preparation for analysis and determination are described in detail. Typical data from various sources showing the effect of proposed regulations is shown. Extensive sampling and usage of these procedures has shown them to be accurate, reliable and suitable to all types of source effluents.

Levaggi, D. A.↗

HPLC Characterization of Phenol-Formaldehyde Resole Resin Used in Fabrication of Shuttle Booster Nozzles

A reverse phase High Performance Liquid Chromatographic method was developed to rapidly fingerprint a phenol-formaldehyde resole resin similar to Durite(R) SC-1008. This resin is used in the fabrication of carbon-carbon composite materials from which Space Shuttle Solid Rocket Booster nozzles are manufactured. A knowledge of resin chemistry is essential to successful composite processing and performance. The results indicate that a high quality separation of over 35 peaks in 25 minutes were obtained using a 15 cm Phenomenex LUNA C8 bonded reverse phase column, a three-way water-acetonitrile-methanol nonlinear gradient, and LTV detection at 280 nm.

Young, Philip R.↗

A Study of Upgraded Phenolic Curing for RSRM Nozzle Rings

A thermochemical cure model for predicting temperature and degree of cure profiles in curing phenolic parts was developed, validated and refined over several years. The model supports optimization of cure cycles and allows input of properties based upon the types of material and the process by which these materials are used to make nozzle components. The model has been refined to use sophisticated computer graphics to demonstrate the changes in temperature and degree of cure during the curing process. The effort discussed in the paper will be the conversion from an outdated solid modeling input program and SINDA analysis code to an integrated solid modeling and analysis package (I-DEAS solid model and TMG). Also discussed will be the incorporation of updated material properties obtained during full scale curing tests into the cure models and the results for all the Reusable Solid Rocket Motor (RSRM) nozzle rings.

Smartt, Ziba↗

Use of GC/MS and Microtome Techniques as Methods to Evaluate ODC Free Cleaner Diffusion and Evaporation in Insulation and Phenolic Case Material

Because of the 1990 Clean Air Act Amendment (CAAA) many chlorinated solvents used in the aerospace industry are being phased out. Replacement of the ODC (ozone-depleting chemicals) with less volatile, non-ozone depleting cleaners has been extensively studied over the past seven years at Thiokol Propulsion, a Division of Cordant Technologies, Inc. The down selection of ODC replacement cleaners has been based on several factors including the diffusion evaporation of the cleaners in selected substrates. Methodologies were developed to evaluate the cleaner content in substrates. Methods of cutting thin slices of material (microtoming) were combined with GC/MS (gas chromatography/mass spectroscopy) analysis. Substrates evaluated in this study include potential solid rocket motor materials: ASNBR (asbestos-filled nitrile butadiene rubber) and CFEPDM (carbon-filled ethylene propylene dimonomer) insulation and glass (GCP), carbon (CCP) and silica (SCP) cloth phenolic substrates with fibers either parallel (0 deg) or perpendicular (90 deg) to the surface. Residue profiles indicate both cleaner and substrate composition affect the diffusion and subsequent evaporation of the cleaner from the substrate surface.

Biegert, L. L.↗

Thermal/Pyrolysis Gas Flow Analysis of Carbon Phenolic Material

Provided in this study are predicted in-depth temperature and pyrolysis gas pressure distributions for carbon phenolic materials that are externally heated with a laser source. Governing equations, numerical techniques and comparisons to measured temperature data are also presented. Surface thermochemical conditions were determined using the Aerotherm Chemical Equilibrium (ACE) program. Surface heating simulation used facility calibrated radiative and convective flux levels. Temperatures and pyrolysis gas pressures are predicted using an upgraded form of the SINDA/CMA program that was developed by NASA during the Solid Propulsion Integrity Program (SPIP). Multispecie mass balance, tracking of condensable vapors, high heat rate kinetics, real gas compressibility and reduced mixture viscosity's have been added to the algorithm. In general, surface and in-depth temperature comparisons are very good. Specie partial pressures calculations show that a saturated water-vapor mixture is the main contributor to peak in-depth total pressure. Further, for most of the cases studied, the water-vapor mixture is driven near the critical point and is believed to significantly increase the local heat capacity of the composite material. This phenomenon if not accounted for in analysis models may lead to an over prediction in temperature response in charring regions of the material.

Clayton, J. Louie↗

Phenol-formaldehyde intumescent coating composition and coating prepared therefrom

Intumescent coatings which form a thick, uniform, fine celled, low density foam upon exposure to a high intensity heat flux or flame are disclosed, the invention coatings comprise phenolic resin prepolymer containing a blowing agent and a nucleating agent; in the preferred embodiments the coatings also contains a silicone surfactant, the coatings are useful in thermal and fire protection systems.

Salyer, Ival O.↗

Effect of Water on the Thermo-Mechanical Behavior of Carbon Cloth Phenolic

The results of thermo-mechanical experiments, which were conducted previously by one of the authors, are reviewed. The strain in the direction normal to the fabric plane was measured as a function of temperature for a variety of initial moisture contents and heating rates. In this paper, the general features of the thermo-mechanical response are discussed and the effect of heating rate and initial moisture content are highlighted. The mechanical interaction between the phenolic polymer and water trapped within its free volumes as the polymer is heated to high temperatures is discussed. An equation for the internal stresses which are generated within the polymer due to trapped water is obtained from the total stress expression for a binary mixture of polymer and water. Numerical solutions for moisture diffusion in the thermo-mechanical experiments were performed and the results of these solutions are presented. The results of the moisture diffusion solutions help to explain the effects of heating rate and moisture content on the strain behavior normal to the fabric plane.

Sullivan, Roy M.↗

Ablation and Thermal Response Property Model Validation for Phenolic Impregnated Carbon Ablator

Phenolic Impregnated Carbon Ablator was the heatshield material for the Stardust probe and is also a candidate heatshield material for the Orion Crew Module. As part of the heatshield qualification for Orion, physical and thermal properties were measured for newly manufactured material, included emissivity, heat capacity, thermal conductivity, elemental composition, and thermal decomposition rates. Based on these properties, an ablation and thermal-response model was developed for temperatures up to 3500 K and pressures up to 100 kPa. The model includes orthotropic and pressure-dependent thermal conductivity. In this work, model validation is accomplished by comparison of predictions with data from many arcjet tests conducted over a range of stagnation heat flux and pressure from 107 Watts per square centimeter at 2.3 kPa to 1100 Watts per square centimeter at 84 kPa. Over the entire range of test conditions, model predictions compare well with measured recession, maximum surface temperatures, and in depth temperatures.

Milos, F. S.↗

Explicit Pore Pressure Material Model in Carbon-Cloth Phenolic

An explicit material model that uses predicted pressure in the pores of a carbon-cloth phenolic (CCP) composite has been developed. This model is intended to be used within a finite-element model to predict phenomena specific to CCP components of solid-fuel-rocket nozzles subjected to high operating temperatures and to mechanical stresses that can be great enough to cause structural failures. Phenomena that can be predicted with the help of this model include failures of specimens in restrained-thermal-growth (RTG) tests, pocketing erosion, and ply lifting

Gutierrez-Lemini, Danton↗

Nonequilibrium Ablation of Phenolic Impregnated Carbon Ablator

In previous work, an equilibrium ablation and thermal response model for Phenolic Impregnated Carbon Ablator was developed. In general, over a wide range of test conditions, model predictions compared well with arcjet data for surface recession, surface temperature, in-depth temperature at multiple thermocouples, and char depth. In this work, additional arcjet tests were conducted at stagnation conditions down to 40 W/sq cm and 1.6 kPa. The new data suggest that nonequilibrium effects become important for ablation predictions at heat flux or pressure below about 80 W/sq cm or 10 kPa, respectively. Modifications to the ablation model to account for nonequilibrium effects are investigated. Predictions of the equilibrium and nonequilibrium models are compared with the arcjet data.

Milos, Frank S.↗

Investigation of Performance Envelope for Phenolic Impregnated Carbon Ablator (PICA)

The present work provides the results of a short exploratory study on the performance of Phenolic Impregnated Carbon Ablator, or PICA, at high heat flux and pressure in an arcjet facility at NASA Ames Research Center. The primary objective of the study was to explore the thermal response of PICA at cold-wall heat fluxes well in excess of 1500 W/cm (exp 2). Based on the results of a series of flow simulations, multiple PICA samples were tested at an estimated cold wall heat flux and stagnation pressure of 1800 W/cm (exp 2) and 130 kPa, respectively. All samples survived the test, and no failure was observed either during or after the exposure. The results indicate that PICA has a potential to perform well at environments with significantly higher heat flux and pressure than it has currently been flown.

Ablative Material↗

Pressure Venting Tests of Phenolic Impregnated Carbon Ablator (PICA)

A series of tests was devised to investigate the pressure venting behavior of one of the candidate ablators for the Orion capsule heat shield. Three different specimens of phenolic impregnated carbon ablator (PICA) were instrumented with internal pressure taps and subjected to rapid pressure changes from near vacuum to one atmosphere and simulated Orion ascent pressure histories. The specimens vented rapidly to ambient pressure and sustained no detectable damage during testing. Peak pressure differences through the thickness of a 3-inch-thick specimen were less than 1 psi during a simulated ascent pressure history.

Blosser, Max L.↗

Assessment of a One-Dimensional Finite Element Charring Ablation Material Response Model for Phenolic-Impregnated Carbon Ablator

In this study, mathematical formulations to model charring ablation problems were numerically implemented using finite element analysis (FEA) with ABAQUS, which account for the material decomposition and progressive surface removal in the heat conduction and the surface energy balance equations. FEA was performed for a one-dimensional model to predict the temperature and ablation histories of a phenolic-impregnated carbon ablator sample (i.e., a common heat shield material for hypersonic vehicles and spacecraft) subjected to oxy-acetylene torch flame (i.e., 0.8 SLPM acetylene gas to 2.7 SLPM oxygen gas). The recovery enthalpy and convective heat transfer coefficient for the ablation model were calculated based on gas compositions and two assumed surface conditions (i.e., equilibrium and frozen). Simulations using the calculated recovery enthalpy and convective heat transfer coefficient resulted in a recession rate of 6.38 times (equilibrium) and 14.08 times (frozen) higher than the experimental data, despite fair agreement of the surface temperature. In addition, the effect of the heat transfer coefficient was investigated through a steady-state ablation analysis. The results of the analysis indicate that there is not one single value for the heat transfer coefficient that would allow the prediction to match both measured recession rate and surface temperature. Possible reasons for such an inconsistency are provided and discussed.

Thermal Protection System↗

Development of Lyocell Based Phenolic Impregnated Carbon Ablators (PICA-D) for Future NASA Missions

Phenolic Impregnated Carbon Ablator (PICA) is a low-density ablator that has been used as the planetary entry heatshield for several NASA missions since 1999. Due to the obsolescence of the input fiber source, new PICA materials were developed using Lyocell, a domestic rayon fiber source. Results are presented from this effort. Manufacturing included fiber conversion, fabrication of tile component and near net shaped heatshield preforms, and conversion to PICA materials. Thermal, mechanical, and representative environment arc-jet testing have been conducted. Initial testing indicates comparable performance with respect to heritage PICA material, and likely "drop-in" replacement for future NASA mission needs.

Thermal Protection↗

Development of Lyocell Based Phenolic Impregnated Carbon Ablator (PICA-D) for Future NASA Missions

Phenolic Impregnated Carbon Ablator (PICA) is a low-density ablator that has been used as the planetary entry heatshield for several NASA missions since 1999. Due to the obsolescence of the input fiber source, new PICA materials were developed using Lyocell, a domestic rayon fiber source. Results are presented from this effort. Manufacturing included fiber conversion, fabrication of tile component and near net shaped heatshield preforms, and conversion to PICA materials. Thermal, mechanical, and representative environment arc-jet testing have been conducted. Initial testing indicates comparable performance with respect to heritage PICA material, and likely "drop-in" replacement for future NASA mission needs.

thermal protection↗

Sustaining Phenolic Impregnated Carbon Ablator (PICA) for Future NASA Missions Including Discovery and New Frontiers

Phenolic Impregnated Carbon Ablator (PICA) was invented in the mid 1990's and due to its relatively low density and efficient performance has been the heat shield TPS of choice for a range of missions includ-ing, Stardust, OSIRIS-Rex, Mars Science Laboratry (MSL) and Mars 2020. PICA has also been the TPS solution on numerous Discovery and New Frontiers proposals, as both the heat shield and back shell TPS and is under consideration as both for the Mars Sample Return Earth Entry Vehicle (EEV) and the heat shield on the Sample Retrieval Lander (SRL). Recently NASA's Science Mission Directorate (SMD) has funded an activity to develop a more sus-tainable version of PICA and to expand the demon-strated capabilities of PICA both in manufacturing and aerothermal performance.

Thermal Protection Material↗

A Computational Study of a Phenolic Based Polymer with a Spring-Like Structure

We report the stretching potentials for a helical phenolic-based polymer with high symmetry and a spring-like structure that can be stretched by a factor of 4 along the spring direction and still return to its original structure. We hope that synthetic polymer chemists assess if this polymer or a similar one can be synthesized and tested.

Charles W Bauschlicher↗

Development of Domestic Lyocell Based Phenolic Impregnated Carbon Ablator (PICA-D) for Future NASA Missions

Phenolic Impregnated Carbon Ablator (PICA) is a low-density ablator that has been used as the planetary entry heatshield for several NASA missions since the late 90's. Its low density and efficient performance characteristics have proven effective for use from Discovery to Flag-ship class missions. The rayon-based carbon precursor raw material used in PICA preform manufacturing has experienced multiple supply chain issues and required replacement and requalification at least twice in the past 25 years, and a third substitution is now needed. Due to the obsolescence of the input foreign rayon fiber source, a new variant of PICA has been developed using a domestic rayon-like fiber source, Lyocell. Results are presented from this effort including fiber conversion, fabrication of tile component and near net shaped heatshield preforms, and conversion to PICA materials. Thermal, mechanical, and representative environment arc-jet tests have been conducted. Initial testing of PICA-Domestic (PICA-D) indicates comparable performance with respect to "heritage" PICA materials and thus PICA-D is expected to be a sustainable solution for future NASA missions.

Drop-In Replacement↗