Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “permanence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Prospects for nanoparticle-based permanent magnets

Magnetic nanoparticles smaller than similar to 15 nm in diameter and with high magnetocrystalline anisotropies K-1 >= 1 MJ m(-3) can be used as building blocks for next-generation permanent magnets. Advances in processing steps are discussed, such as self-assembly, alignment of the easy axes and appropriate nanostructuring that will enable the fabrication of densely packed nanopartide assemblies with improved permanent-magnet properties. This study also proposes an idealized nanocomposite structure for nanoparticle-based future permanent magnets with enhanced energy products. (C) 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Balamurugan, B↗

Permanent uncoupling of male-specific CYP2C11 transcription/translation by perinatal glutamate

Perinatal exposure of rats and mice to the typically reported 4 mg/g bd wt dose of monosodium glutamate (MSG) results in a complete block in GH secretion as well as obesity, growth retardation and a profound suppression of several cytochrome P450s, including CYP2C11, the predominant male-specific isoform — all irreversible effects. In contrast, we have found that a lower dose of the food additive, 2 mg/g bd wt on alternate days for the first 9 days of life results in a transient neonatal depletion of plasma GH, a subsequent permanent overexpression of CYP2C11 as well as subnormal (mini) GH pulse amplitudes in an otherwise normal adult masculine episodic GH profile. The overexpressed CYP2C11 was characterized by a 250% increase in mRNA, but only a 40 to 50% increase in CYP2C11 protein and its catalytic activity. Using freshly isolated hepatocytes as well as primary cultures exposed to the masculine-like episodic GH profile, we observed normal induction, activation, nuclear translocation and binding to the CYP2C11 promoter of the GH-dependent signal transducers required for CYP2C11 transcription. The disproportionately lower expression levels of CYP2C11 protein were associated with dramatically high expression levels of an aberrant, presumably nontranslated CYP2C11 mRNA, a 200% increase in CYP2C11 ubiquitination and a 70–80% decline in miRNAs associated, at normal levels, with a suppression of CYP2C expression. Whereas the GH-responsiveness of CYP2C7 and CYP2C6 as well as albumin was normal in the MSG-derived hepatocytes, the abnormal expression of CYP2C11 was permanent and irreversible. - Highlights: • A “low” neonatal dose of MSG causes an immediate but transient growth hormone depletion. • Adult circulating growth hormone contains mini pulses in an otherwise male profile. • CYP2C11 is permanently overexpressed > 250%; CYP2C6, 2C7 and albumin remain normal. • The bulk of the overexpressed CYP2C11 mRNA consists of an intron-retained form. • SOCS2 and miRNAs are subnormal, ubiquitination is elevated but JAK2/STAT5b is normal.

60 APPLIED LIFE SCIENCES↗

Charge trapping and de-trapping in isolated CdSe/ZnS nanocrystals under an external electric field: Indirect evidence for a permanent dipole moment

Single nanoparticle studies of charge trapping and de-trapping in core/shell CdSe/ZnS nanocrystals incorporated into an insulating matrix and subjected to an external electric field demonstrate the ability to reversibly modulate the exciton dynamics and photoluminescence blinking while providing indirect evidence for the existence of a permanent ground state dipole moment in such nanocrystals. A model assuming the presence of energetically deep charge traps physically aligned along the direction of the permanent dipole is proposed in order to explain the dynamics of nanocrystal blinking in the presence of a permanent dipole moment.

36 MATERIALS SCIENCE↗

Effect of atom substitutions on the magnetic properties in Ce 2 Fe 17 : Toward permanent magnet applications

Due to the rapidly developing technologies and huge market demand, there has been increasing interest internationally in exploring permanent magnet formulations in addition to the well-known Nd 2 Fe 14 B and SmCo 5 /Sm 2 Co 17 . Given Fe's low materials cost and generally high magnetization, Fe-rich rare earth binaries such as Ce 2 Fe 17 comprise a rich “hunting ground” for such new materials. While this compound suffers from a low ordering point and is a heli magnet, these difficulties are easily remedied by the substitution of appropriate amounts of cobalt for Fe, with room-temperature saturation magnetization as high as 1.5 T. In this work, we try to switch the all-important magnetic anisotropy from planar to uniaxial behavior in Ce 2 Fe 17 via 18 h - and 6 c -type atom substitutions with Si, Ir, and numerous other atoms. The uniaxial magnetocrystalline anisotropy is successfully achieved in the 6 c -site-substituted Ce 2 Fe 15 Ir 2 systems, along with large magnetization. We find that iridium substitution, in particular, induces a substantial uniaxial anisotropy of 11.25 MJ/m 3 , which is comparable to most of the current rare earth permanent magnets. Although the iridium substitution is costly, the finding of Ir-triggered uniaxial magnetic anisotropy indicates the potential of Ce–Fe-based alloys for permanent magnets.

36 MATERIALS SCIENCE↗

Greedy permanent magnet optimization

Abstract A number of scientific fields rely on placing permanent magnets in order to produce a desired magnetic field. We have shown in recent work that the placement process can be formulated as sparse regression. However, binary, grid-aligned solutions are desired for realistic engineering designs. We now show that the binary permanent magnet problem can be formulated as a quadratic program with quadratic equality constraints, the binary, grid-aligned problem is equivalent to the quadratic knapsack problem with multiple knapsack constraints, and the single-orientation-only problem is equivalent to the unconstrained quadratic binary problem. We then provide a set of simple greedy algorithms for solving variants of permanent magnet optimization, and demonstrate their capabilities by designing magnets for stellarator plasmas. The algorithms can a-priori produce sparse, grid-aligned, binary solutions. Despite its simple design and greedy nature, we provide an algorithm that compares with or even outperforms the state-of-the-art algorithms while being substantially faster, more flexible, and easier to use.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Theory of dissociative recombination of a linear triatomic ion with permanent electric dipole moment: Study of HCO{sup +}

We present a theoretical description of dissociative recombination of triatomic molecular ions having large permanent dipole moments. The study has been partly motivated by a discrepancy between experimental and theoretical cross sections for dissociative recombination of the HCO{sup +} ion. The HCO{sup +} ion has a considerable permanent dipole moment (Dapprox =4 D), which has not been taken explicitly into account in previous theoretical studies. In the present study, we include explicitly the effect of the permanent electric dipole on the dynamics of the incident electron using the generalized quantum defect theory, and we present the resulting cross section obtained. This demonstrates the possibility of applying generalized quantum defect theory to the dissociative recombination of molecular ions.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-performance permanent-magnet materials based on CeFe 12

We perform first-principles calculations on the Mo/Zr-alloyed ThMn 12 -structure prototype CeFe 12 to explore its electronic and magnetic properties and potential for permanent magnet applications. A recent experiment has shown that the Mo/Zr-alloyed CeFe 12 phase with the symmetry 𝐼⁢4/𝑚⁢𝑚⁢𝑚 can be stabilized in bulk. It encourages an investigation into the intrinsic magnetic characteristics of the base structure CeFe 12 and the effect of transition metal alloying in it. Our calculations reveal that the base structure prototype CeFe 12 in its tetragonal phase exhibits uniaxial magnetic anisotropy with a magnetic anisotropy energy (𝐾 1 ) ∼ 1 MJ/m −3 and a substantial magnetic moment of ∼ 1.8T, showing its promise as a permanent magnet. The introduction of the stabilizing transition metals Zr, Mo, and W reduces these values but still keeps the materials very promising. Notably, when 50% of Ce is substituted by Sm in Mo-alloyed CeFe 12 , the 𝐾 1 is significantly enhanced, accompanied by a fairly decent magnetic moment of ∼ 1.2T. These findings establish this alloy as a strong candidate for high-performance permanent magnet applications. In conclusion, this study emphasizes the importance of strategic element substitution and site selection in transition metal-alloyed CeFe 12 to achieve both structural stability and remarkable magnetic properties.

Density of states↗

Comparative Life Cycle Assessment of Injection Molded and Big Area Additive Manufactured NdFeB Bonded Permanent Magnets

Permanent magnets are expected to play a crucial role in the realization of the clean economy. In particular, the neodymium-iron-boron (Nd2Fe14B or NdFeB) magnets, which have the highest energy density among rare earth permanent magnets, are needed for building more efficient windmill generators, electric vehicle motors, etc. Currently, near-net shape magnets can be either made through sintering and compression molding with extensive post machining or directly through injection molding. However, injection molding has a loading volume fraction limitation of 0.65 for nylon binders. A novel method of manufacturing bonded permanent magnets with loading fraction greater than 0.65 has been demonstrated using Big Area Additive Manufacturing (BAAM) printers. As energy density is directly proportional to the square of the magnet loading fraction, magnets produced using BAAM printers require less volume and magnetic material compared to that of injection molded magnets on average. A comparative LCA shows that this difference in magnetic powder consumption nearly constitutes the difference in the environmental impact categories. Even after assuming recycled magnetic input, the BAAM magnets perform better environmentally than injection molded magnets, especially in the ozone depletion category. Since BAAM printers can accommodate even higher loading fractions, at scale, BAAM printers possibly can bring about a significant decrease in rare earth mineral consumption and environmental emissions. So furthermore, single screw extrusion enables BAAM printers to have high print speeds and allow them to be economically competitive against injection molding. Therefore, BAAM printed magnets show promise in transitioning towards the clean economy.

36 MATERIALS SCIENCE↗

Experimental evaluation of an online gamma-camera imaging of permanent seed implantation (OGIPSI) prototype for partial breast irradiation

Previously, our team used Monte Carlo simulation to demonstrate that a gamma camera could potentially be used as an online image guidance device to visualize seeds during permanent breast seed implant procedures. This could allow for intraoperative correction if seeds have been misplaced. The objective of this study is to describe an experimental evaluation of an online gamma-camera imaging of permanent seed implantation (OGIPSI) prototype. The OGIPSI device is intended to be able to detect a seed misplacement of 5 mm or more within an imaging time of 2 min or less. The device was constructed by fitting a custom built brass collimator (16 mm height, 0.65 mm hole pitch, 0.15 mm septal thickness) on a 64 pixel linear array CZT detector (eValuator-2000, eV Products, Saxonburg, PA). Two-dimensional projection images of seed distributions were acquired by the use of a digitally controlled translation stage. Spatial resolution and noise characteristics of the detector were measured. The ability and time needed for the OGIPSI device to image the seeds and to detect cold spots was tested using an anthropomorphic breast phantom. Mimicking a real treatment plan, a total of 52 {sup 103}Pd seeds of 65.8 MBq each were placed on three different layers at appropriate depths within the phantom. The seeds were reliably detected within 30 s with a median error in localization of 1 mm. In conclusion, an OGIPSI device can potentially be used for image guidance of permanent brachytherapy applications in the breast and, possibly, other sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-55: Biological Equivalent Dose (BED) Comparison Between Permanent Interstitial Brachytherapy and Conventional External Beam Radiotherapy for Prostate Cancer

Purpose: The goal of this research is to calculate and compare the Biological Equivalent Dose (BED) between permanent prostate Iodine-125 implant brachytherapy as monotherapy with the BED of conventional external beam radiation therapy (EBRT). Methods: A retrospective study of 605 patients treated with Iodine-125 seed implant was performed in which physician A treated 274 patients and physician B treated 331 patients. All the Brachytherapy treatment plans were created using VariSeed 8 planning system. The Iodine-125 seed source activities and loading patterns varied slightly between the two physicians. The prescription dose is 145 Gy to PTV for each patient. The BED and Tumor Control Probability (TCP) were calculated based on the TG 137 formulas. The BED for conventional EBRT of the prostate given in our institution in 2Gy per fraction for 38 fractions was calculated and compared. Results: Physician A treated 274 patients with an average BED of 123.92±0.87 Gy and an average TCP of 99.20%; Physician B treated 331 patients with an average BED of 124.87±1.12 Gy and an average TCP of 99.30%. There are no statistically significant differences (T-Test) between the BED and TCP values calculated for these two group patients.The BED of the patients undergoing conventional EBRT is calculated to be 126.92Gy. The BED of the patients treated with permanent implant brachytherapy and EBRT are comparable. Our BED and TCP values are higher than the reported values by TG 137 due to higher Iodine-125 seed activity used in our institution. Conclusion: We calculated the BED,a surrogate of the biological response to a permanent prostate brachytherapy using TG 137 formulas and recommendation. The TCP of better than 99% is calculated for these patients. A clinical outcome study of these patients correlating the BED and TCP values with PSA and Gleason Levels as well as patient survival is warranted.

60 APPLIED LIFE SCIENCES↗

SU-F-J-167: Use of MR for Permanent Prostate Implant Preplanning

Purpose: To study the feasibility using MR imaging to improve target definition on ultrasound during permanent prostate implants and aid in source strength determination for treatment planning in the OR. Methods: Patients who receive permanent prostate implants undergo MR and CT imaging prior to the implant procedure to determine the volume of the prostate, bony restriction to the procedure, bladder extension, external sphincter length and neurovascular bundle. The volume of the prostate is generally used to order seeds for the procedure. In 10 patients, the MR was used as the preplanning study with the PTV defined as a 2 mm expansion of the MR prostate in all directions except the posterior. Various dose volume parameters for the MR prostate and the PTV were compared to the actual preplan developed and executed in the OR. In addition, there parameters were compared to the post implant dosimetry performed 3 weeks after the implant procedure. Results: The results show that the number of seeds used using MR and US (ultrasound) planning was generally with 2 seeds and the maximum difference was 7 seeds. There is no significant difference between any of the dose index parameters of V100, V150, V200, D99 and D90 parameters between MR planning, US planning and postimplant evaluation There was a significant difference between planned D99 (avg of 105%) and achieved D99 (avg 91%). Conclusion: MR imaging is an invaluable tool to improve target definition for permanent prostate implants. Use of MR images for preplanning improves the confidence with which source can be ordered for the procedure that is OR planned. Ordering a maximum of 10 seeds more than planned would be sufficient to deliver a plan in the OR using US. Moving ahead to non-rigid registration between MR ad US images could further increase the confidence level of MR planning.

60 APPLIED LIFE SCIENCES↗

Status Update of Permanent Magnet Radiation Resiliency Studies at CEBAF

The proposed energy upgrade of the Continuous Electron Beam Accelerator Facility (CEBAF) incorporates Fixed-Field Alternating-gradient (FFA) arcs utilizing permanent magnet technology. Given the radiation environment within the CEBAF tunnel enclosure, validating the long-term magnetic stability of these materials is a critical step for the project's technical feasibility. This contribution presents an overview of the ongoing permanent magnet radiation resiliency program at Jefferson Lab. We briefly review the experimental methodology used to monitor demagnetization in situ and summarize the operational experience from the initial data-taking campaign. Furthermore, we discuss the upgrades implemented for the second exposure campaign, currently underway, which aims to refine dose correlation and reduce systematic uncertainties. We report on the general status of the program and the roadmap for certifying permanent magnet optics for the proposed upgrade energies.

Bodenstein, R. [Thomas Jefferson National Accelera↗

Optimizing accuracy of determinations of CO₂ storage capacity and permanence, and designing more efficient storage operations: An example from the Rock Springs Uplift, Wyoming

At a potential injection site on the Rock Springs Uplift in southwest Wyoming, an investigation of confining layers was undertaken to develop and test methodology, identify key data requirements, assess previous injection scenarios relative to detailed confining layer properties, and integrate all findings in order to reduce the uncertainty of CO₂ storage permanence. The assurance of safe and permanent storage of CO₂ at a storage site involves a detailed evaluation of the confining layers. Four suites of field data were recognized as crucial for determining storage permanence relative to the confining layers; seismic, core and petrophysical data from a wellbore, formation fluid samples, and in-situ formation tests. Core and petrophysical data were used to create a vertical heterogenic property model that defined porosity, permeability, displacement pressure, geomechanical strengths, and diagenetic history. These analyses identified four primary confining layers and multiple redundant confining layers. In-situ formation tests were used to evaluate fracture gradients, regional stress fields, baseline microseismic data, step-rate injection tests, and formation perforation responses. Seismic attributes, correlated with the vertical heterogenic property models, were calculated and used to create a 3-D volume model over the entire site. The seismic data provided the vehicle to transform the vertical heterogenic property model into a horizontal heterogenic property model, which allowed for the evaluation of confining layers across the entire study site without risking additional wellbore perforations. Lastly, formation fluids were collected and analyzed for geochemical and isotopic compositions from stacked reservoir systems. These data further tested primary confining layers, by evaluating the evidence of mixing between target reservoirs (mixing would imply an existing breach of primary confining layers). All data were propagated into a dynamic, heterogenic geologic property model used to test various injection scenarios. These tests showed that the study site could retain 25MT of injected CO₂ over an injection lifespan of 50 years. Major findings indicate that active reservoir pressure management through reservoir fluid production (minimum of three production wells) greatly reduces the risk of breaching a confining layer. To address brine production, a well completion and engineering study was incorporated to reduce the risks of scaling and erosion during injection and production. These scenarios suggest that the dolostone within the Mississippian Madison Limestone is the site’s best injection/production target by two orders of magnitude, and that commercial well equipment would meet all performance requirements. This confirms that there are multiple confining layers in southwest Wyoming that are capable of retaining commercial volumes of CO₃, making Wyoming’s Paleozoic reservoirs ideal storage targets for low-risk injection and long-term storage. This study also indicates that column height retention calculations are reduced in a CO₂-brine system relative to a hydrocarbon-brine system, which is an observation that affects all potential CCS sites. Likewise, this study identified the impacts that downhole testing imparts on reservoir fluids, and the likelihood of introducing uncertainty in baseline site assumptions and later modeling.

25 ENERGY STORAGE↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

Methods for Measuring Carbon Dioxide Uptake and Permanence: Review and Implications for Macroalgae Aquaculture

Carbon dioxide removal (CDR) is gaining recognition as a necessary action in addition to emissions reduction to prevent some of the worst effects of climate change. Macroalgae aquaculture has been identified as a potential CDR strategy and significant research investments have been made in this area. This article reviews current methods for monitoring carbon to assess the potential for application in the context of macroalgae aquaculture as a CDR strategy. In total, 382 papers were included in the review and categorized by carbon uptake methods, carbon permanence methods, and comprehensive frameworks for assessing carbon capture. While methods for measuring carbon uptake are well established, methods to assess the permanence of carbon in the natural life cycle of macroalgae and in products following harvest are lacking. To achieve the full benefit of macroalgae cultivation as a climate solution, monitoring, reporting, and verification standards and improved methods for assessing carbon uptake and permanence need to be developed.

59 BASIC BIOLOGICAL SCIENCES↗

Lodestone: Nature's own permanent magnet

Magnetic hysteresis and microstructural details are presented which explain why the class of magnetic iron ores defined as proto-lodestones, can behave as permanent magnets, i.e. lodestones. Certain of these proto-lodestones which are not permanent magnets can be made into permanent magnets by charging in a field greater than 1000 oersted. This fact, other experimental observations, and field evidence from antiquity and the middle ages, which seems to indicate that lodestones are found as localized patches within massive ore bodies, suggests that lightning might be responsible for the charging of lodestones. The large remanent magnetization, high values of coercive force, and good time stability for the remanent magnetization are all characteristics of proto-lodestone iron ores which behave magnetically as fine scale ( 10 micrometer) intergrowths when subjected to magnetic hysteresis analysis. The magnetic results are easily understood by analysis of the complex proto lodestone microstructural patterns observable at the micrometer scale and less.

Wasilewski, P.↗

The Manned Space Platform as an evolutionary means to achieve a permanent manned orbital operations facility

An evolutionary approach to permanently manned on-orbit facilities is discussed, and it is noted that the Science and Applications Manned Space Platform, which is the first step in this evolution, can be based primarily on existing and currently planned hardware. It is shown how by upgrading the systems capabilities of the Spacelab modules, the platform can be reconfigured to provide a permanent manned research and operations facility. The facility can grow in size and capability to accommodate increases in user requirements, more experiment modules, and larger crews and to provide additional power and heat rejection. It is noted that the Growth-Permanently Manned Facility can be used for science activities and/or to support various operations functions such as space construction, servicing and maintaining space systems, and vehicle assembly.

Schwartz, J. M.↗

Self-Centering Reciprocating-Permanent-Magnet Machine

New design for monocoil reciprocating-permanent-magnet electric machine provides self-centering force. Linear permanent-magnet electrical motor includes outer stator, inner stator, and permanent-magnet plunger oscillateing axially between extreme left and right positions. Magnets arranged to produce centering force and allows use of only one coil of arbitrary axial length. Axial length of coil chosen to provide required efficiency and power output.

Bhate, Suresh↗