Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Electrochemical performance studies of MnO{sub 2} nanoflowers recovered from spent battery

Highlights: • MnO{sub 2} is recovered from spent zinc–carbon batteries as nanoflowers structure. • Recovered MnO{sub 2} nanoflowers show high specific capacitance. • Recovered MnO{sub 2} nanoflowers show stable electrochemical cycling up to 900 cycles. • Recovered MnO{sub 2} nanoflowers show low resistance in EIS data. - Abstract: The electrochemical performance of MnO{sub 2} nanoflowers recovered from spent household zinc–carbon battery is studied by cyclic voltammetry, galvanostatic charge/discharge cycling and electrochemical impedance spectroscopy. MnO{sub 2} nanoflowers are recovered from spent zinc–carbon battery by combination of solution leaching and electrowinning techniques. In an effort to utilize recovered MnO{sub 2} nanoflowers as energy storage supercapacitor, it is crucial to understand their structure and electrochemical performance. X-ray diffraction analysis confirms the recovery of MnO{sub 2} in birnessite phase, while electron microscopy analysis shows the MnO{sub 2} is recovered as 3D nanostructure with nanoflower morphology. The recovered MnO{sub 2} nanoflowers exhibit high specific capacitance (294 F g{sup −1} at 10 mV s{sup −1}; 208.5 F g{sup −1} at 0.1 A g{sup −1}) in 1 M Na{sub 2}SO{sub 4} electrolyte, with stable electrochemical cycling. Electrochemical data analysis reveal the great potential of MnO{sub 2} nanoflowers recovered from spent zinc–carbon battery in the development of high performance energy storage supercapacitor system.

36 MATERIALS SCIENCE↗

Performance study of LMS based adaptive algorithms for unknown system identification

Adaptive filtering techniques have gained much popularity in the modeling of unknown system identification problem. These techniques can be classified as either iterative or direct. Iterative techniques include stochastic descent method and its improved versions in affine space. In this paper we present a comparative study of the least mean square (LMS) algorithm and some improved versions of LMS, more precisely the normalized LMS (NLMS), LMS-Newton, transform domain LMS (TDLMS) and affine projection algorithm (APA). The performance evaluation of these algorithms is carried out using adaptive system identification (ASI) model with random input signals, in which the unknown (measured) signal is assumed to be contaminated by output noise. Simulation results are recorded to compare the performance in terms of convergence speed, robustness, misalignment, and their sensitivity to the spectral properties of input signals. Main objective of this comparative study is to observe the effects of fast convergence rate of improved versions of LMS algorithms on their robustness and misalignment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electromagnetic 3D-guidance device: A preliminary performance study

Purpose: In order to increase the accuracy and speed of catheter reconstruction in a high-dose-rate (HDR) prostate implant procedure, an automatic tracking system has been developed using an electromagnetic (EM) device (trakSTAR, Ascension Technology, VT). The performance of the system, including the accuracy and noise level with various tracking parameters and conditions, were investigated. Methods: A direct current (dc) EM transmitter (midrange model) and a sensor with diameter of 1.3 mm (Model 130) were used in the trakSTAR system for tracking catheter position during HDR prostate brachytherapy. Localization accuracy was assessed under both static and dynamic analyses conditions. For the static analysis, a calibration phantom was used to investigate error dependency on operating room (OR) table height (bottom vs midposition vs top), sensor position (distal tip of catheter vs connector end of catheter), direction [left-right (LR) vs anterior-posterior (AP) vs superior-inferior (SI)], sampling frequency (40 vs 80 vs 120 Hz), and interference from OR equipment (present vs absent). The mean and standard deviation of the localization offset in each direction and the corresponding error vectors were calculated. For dynamic analysis, the paths of five straight catheters were tracked to study the effects of directions, sampling frequency, and interference of EM field. Statistical analysis was conducted to compare the results in different configurations. Results: When interference was present in the static analysis, the error vectors were significantly higher at the top table position (3.3 {+-} 1.3 vs 1.8 {+-} 0.9 mm at bottom and 1.7 {+-} 1.0 mm at middle, p < 0.001), at catheter end position (3.1 {+-} 1.1 vs 1.4 {+-} 0.7 mm at the tip position, p < 0.001), and at 40 Hz sampling frequency (2.6 {+-} 1.1 vs 2.4 {+-} 1.5 mm at 80 Hz and 1.8 {+-} 1.1 at 160 Hz, p < 0.001). So did the mean offset errors in the LR direction (-1.7 {+-} 1.4 vs 0.4 {+-} 0.5 mm in AP and 0.8 {+-} 0.8 mm in SI directions, p < 0.001). The error vectors were significantly higher with surrounding interference (2.2 {+-} 1.3 mm) vs without interference (1.0 {+-} 0.7 mm, p < 0.001). An accuracy of 1.6 {+-} 0.2 mm can be reached when using optimum configuration (160 Hz at middle table position). When interference was present in the dynamic tracking, the mean tracking errors in LR direction (1.4 {+-} 0.5 mm) was significantly higher than that in AP direction (0.3 {+-} 0.2 mm, p < 0.001). So did the mean vector errors at 40 Hz (2.1 {+-} 0.2 mm vs 1.3 {+-} 0.2 mm at 80 Hz and 0.9 {+-} 0.2 mm at 160 Hz, p < 0.05). However, when interference was absent, they were comparable in the both directions and at all sampling frequencies. An accuracy of 0.9 {+-} 0.2 mm was obtained for the dynamic tracking when using optimum configuration. Conclusions: The performance of an EM tracking system depends highly on the system configuration and surrounding environment. The accuracy of EM tracking for catheter reconstruction in a prostate HDR brachytherapy procedure can be improved by reducing interference from surrounding equipment, decreasing distance from transmitter to tracking area, and choosing appropriated sampling frequency. A calibration scheme is needed to further reduce the tracking error when the interference is high.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Probability friends-of-friends (PFOF) group finder: Performance study and observational data applications on photometric surveys

In tandem with observational data sets, we utilize realistic mock catalogs, based on a semi-analytic galaxy formation model, constructed specifically for Pan-STARRS1 Medium Deep Surveys to assess the performance of the Probability Friends-of-Friends (PFOF) group finder, and aim to develop a grouping optimization method applicable to surveys like Pan-STARRS1. Producing mock PFOF group catalogs under a variety of photometric redshift accuracies (σ{sub Δz/(1+z{sub s)}}), we find that catalog purities and completenesses from 'good' (σ{sub Δz/(1+z{sub s)}}∼ 0.01) to 'poor' (σ{sub Δz/(1+z{sub s)}}∼ 0.07) photo-zs gradually degrade from 77% and 70% to 52% and 47%, respectively. A 'subset optimization' approach is developed by using spectroscopic-redshift group data from the target field to train the group finder for application to that field and demonstrated using zCOSMOS groups for PFOF searches within PS1 Medium Deep Field04 (PS1MD04) and DEEP2 EGS groups in PS1MD07. With four data sets spanning the photo-z accuracy range from 0.01 to 0.06, we find purities and completenesses agree with their mock analogs. Further tests are performed via matches to X-ray clusters. We find PFOF groups match ∼85% of X-ray clusters identified in COSMOS and PS1MD04, lending additional support to the reliability of the detection algorithm. In the end, we demonstrate, by separating red and blue group galaxies in the EGS and PS1MD07 group catalogs, that the algorithm is not biased with respect to specifically recovering galaxies by color. The analyses suggest the PFOF algorithm shows great promise as a reliable group finder for photometric galaxy surveys of varying depth and coverage.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance studies on solar collector with grooved absorber tube configuration using aqueous ZnO–ethylene glycol nanofluids

Solar flat plate collector (SFPC) is regarded as one of the best renewable energy devices to acquire hot water for domestic usage. Though its theoretical efficiency is projected at higher scale, its conversion efficiency is observed to be low due to various collector losses. Hence, to achieve improved performance of collector different techniques for heat transfer augmentation in circular pipes can be adopted. Among passive and active techniques available, passive is preferred over active due to economics and saving in exergy. Hence, in the present study absorber tube configuration is modified with internal grooves in the collector setup to enhance the rate of heat transfer. Also, fluids dispersed with metal oxide particles provide an increase in thermal conductivity such that ZnO-based aqueous EG mixture nanofluid is used as working medium to analyze the performance of collector setup. Also, the change in heat transfer rate and temperature profile of grooved tubes under forced laminar conditions for different working fluids are compared and reported.

14 SOLAR ENERGY↗

Structured light scanning artifact-based performance study

Structured light scanning is used to create a digital twin of a manufactured part, where features are extracted to determine if the part meets the designer’s intent and required tolerances. This paper describes repeatability and reproducibility analyses for a commercially-available structured light scanning system and measurement artifact. The repeatability study used five repeated scans at 15 measurement positions. Repeatability was assessed by randomly selecting one of the five scans at each of the 15 positions and creating a part mesh. This process was performed 50 times and the statistics for the dimension variations were calculated to isolate the scanning effects only. The same sequence was then performed for 10 of the 15 positions and five of the 15 positions to evaluate the repeatability sensitivity to the number of measurement positions. Reproducibility was assessed by selecting 15 positions to create a mesh and repeating the 15-position measurement sequence 10 times using different positions for each mesh construction. The statistics for the dimension variations were then calculated. This incorporated the effects of both scanning and the position and orientation of the part relative to the scanner. This sequence was repeated for 10-position and five-position scans to evaluate the corresponding sensitivity. Finally, the artifact dimensions from structured light scanning were compared to coordinate measuring machine measurements of the same features.

42 ENGINEERING↗

NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system

Purpose: The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study. Despite the complementary imaging capabilities of PET and MRI, their respective hardware tends to be incompatible due to mutual interference. In this work, the GE SIGNA PET/MR is evaluated in terms of PET performance and the potential effects of interference from MRI operation. Methods: The NEMA NU 2-2012 protocol was followed to measure PET performance parameters including spatial resolution, noise equivalent count rate, sensitivity, accuracy, and image quality. Each of these tests was performed both with the MR subsystem idle and with continuous MR pulsing for the duration of the PET data acquisition. Most measurements were repeated at three separate test sites where the system is installed. Results: The scanner has achieved an average of 4.4, 4.1, and 5.3 mm full width at half maximum radial, tangential, and axial spatial resolutions, respectively, at 1 cm from the transaxial FOV center. The peak noise equivalent count rate (NECR) of 218 kcps and a scatter fraction of 43.6% are reached at an activity concentration of 17.8 kBq/ml. Sensitivity at the center position is 23.3 cps/kBq. The maximum relative slice count rate error below peak NECR was 3.3%, and the residual error from attenuation and scatter corrections was 3.6%. Continuous MR pulsing had either no effect or a minor effect on each measurement. Conclusions: Performance measurements of the ToF-PET whole body GE SIGNA PET/MR system indicate that it is a promising new simultaneous imaging platform.

60 APPLIED LIFE SCIENCES↗

Performance study of polycrystalline CVD diamond detectors for fast neutron monitoring

Diamond detectors using polycrystalline CVD diamond substrates of thickness 300μm and 100μm were fabricated for fast neutron monitoring application.. The characterization of detectors was carried out using various tests such as leakage current, capacitance and alpha particle response. The performance of detectors was evaluated for fast neutrons at different neutron yields. The results presented in this work demonstrate that the diamond detectors will be suitable for monitoring fast neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single cell performance studies on the Fe/Cr Redox Energy Storage System using mixed reactant solutions at elevated temperature

Experimental studies in a 14.5 sq cm single cell system using mixed reactant solutions at 65 C are described. Systems were tested under isothermal conditions i.e., reactants and the cell were at the same temperature. Charging and discharging performance were evaluted by measuring watt-hour and coulombic efficiencies, voltage-current relationships, hydrogen evolution and membrane resistivity. Watt-hour efficiencies ranged from 86% at 43 ma/sq cm to 75% at 129 ma/sq cm with corresponding coulombic efficiencies of 92% and 97%, respectively. Hydrogen evolution was less than 1% of the charge coulombic capacity during charge-discharge cycling. Bismuth and bismuth-lead catalyzed chromium electrodes maintained reversible performance and low hydrogen evolution under normal and adverse cycling conditions. Reblending of the anode and cathode solutions was successfully demonstrated to compensate for osmotic volume changes. Improved performance was obtained with mixed reactant systems in comparison to the unmixed reactant systems.

Gahn, R. F.↗

Single cell performance studies on the FE/CR Redox Energy Storage System using mixed reactant solutions at elevated temperature

Experimental studies in a 14.5 sq cm single cell system using mixed reactant solutions at 65 C are described. Systems were tested under isothermal conditions, i.e., reactants and the cell were at the same temperature. Charging and discharging performance were evaluated by measuring watt-hour and coulombic efficiencies, voltage-current relationships, hydrogen evolution and membrane resistivity. Watt-hour efficiencies ranged from 86 percent at 43 ma/sq cm to 75 percent at 129 ma/sq cm with corresponding coulombic efficiencies of 92 percent and 97 percent, respectively. Hydrogen evolution was less than 1 percent of the charge coulumbic capacity during charge-discharge cycling. Bismuth amd bismuth-lead catalyzed chromium electrodes maintained reversible performance and low hydrogen evolution under normal and adverse cycling conditions. Reblending of the anode and cathode solutions was successfully demonstrated to compensate for osmotic volume changes. Improved performance was obtained with mixed reactant systems in comparison to the unmixed reactant systems. Previously announced in STAR as N83-25042

Gahn, R. F.↗

HIRIS performance study

The remote sensing system simulation is used to study a proposed sensor concept. An overview of the instrument and its parameters is presented, along with the model of the instrument as implemented in the simulation. Signal-to-noise levels of the instrument under a variety of system configurations are presented and discussed. Classification performance under these varying configurations is also shown, along with relationships between signal-to-noise ratios, feature selection, and classification performance.

Kerekes, John P.↗

Chimera Events for Performance Studies of the MicroBooNE Deep Learning-based Low Energy Excess Search

MicroBooNE is a short baseline neutrino oscillation experiment based at Fermilab that employs Liquid Argon Time Projection Chamber (LArTPC) technology. One of its target measurements is to investigate the nature of the excess of low energy electron-like events observed by MiniBooNE. This measurement will require an excellent understanding of systematic uncertainties, obtained through testing the performance of reconstruction algorithms on samples with known properties. However, using exclusively Monte Carlo events for this task is limited by how well the discrepancies between simulation and data are understood. An alternative is to test against samples of “chimera” events, which are made up of separate single-particle components from data that are combined to create neutrino-like events. These chimera events can be used to help quantify systematic uncertainties. This note covers the performance and status of creating and using chimera events that match a target neutrino topology in MicroBooNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AMTEC system performance studies using the detailed electrode kinetic and transport model

A detailed electrochemical model of the alkali metal thermoelectric converter (AMTEC) electrode and current collector grid has been developed recently. Comparative evaluations of the resulting differences in model predictions reveal that the new detailed model predicts up to 50 percent higher electrode power densities at condenser operating temperatures above 600 K. The new model, with experimentally determined parameters, was used to recalculate the projected system performance of previously reported 1- and 100-kWe AMTEC space power systems that had incorporated earlier electrolyte/electrode models. It was found that when the detailed model was used to determine the electrode power densities, enhanced specific power and efficiencies are predicted.

Sievers, Robert K.↗

Beam test performance studies of CMS Phase-2 Outer Tracker module prototypes

A new tracking detector will be installed as part of thePhase-2 upgrade of the CMS detector for the high-luminosity LHC era.This tracking detector includes the Inner Tracker, equipped withsilicon pixel sensor modules, and the Outer Tracker, consisting ofmodules with two parallel stacked silicon sensors. The Outer Trackerfront-end ASICs will be able to correlate hits from chargedparticles in these two sensors to perform on-module discriminationof transverse momenta (p$_{T}$). The p$_{T}$information is generated at a frequency of 40 MHz and will be usedin the Level-1 trigger decision of CMS. Prototypes of theso-called 2S modules were tested at the Test Beam Facility at DESYHamburg between 2019 and 2020. These modules use the finalfront-end ASIC, the CMS Binary Chip (CBC), and for the firsttime the Concentrator Integrated Circuit (CIC), optical readoutand on-module power conversion. In total, seven modules were tested,one of which was assembled with sensors irradiated with protons. Animportant aspect was to show that it is possible to read out modulessynchronously. A cluster hit efficiency of about 99.75 % wasachieved for all modules. The CBC p$_{T}$ discriminationmechanism has been verified to work together with the CIC andoptical readout. The measured module performance meets therequirements for operation in the upgraded CMS tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Performance Study of Quantum ESPRESSO’s PWscf Code on Multi-core and GPU Systems

We describe the porting of PWscf (Plane-Wave Self Consistent Field), a key component of the Quantum ESPRESSO open-source suite of codes for materials modeling, to GPU systems using CUDA Fortran. Kernel loop directives (CUF kernels) have been extensively used in order to have a single source code for both CPU and GPU implementations. The results of the GPU version have been carefully validated and the performance of the code on several GPU systems (both x86 and POWER8 based) has been compared with traditional Intel multi-core (CPU only) systems. This current GPU version can reduce the time-to-solution by an average factor of 2–3 running two different input cases widely used as benchmarks on small and large high performance computing systems.

CUDA Fortran↗

Kinetic and Performance Studies of the Regeneration Phase of Model Pt/Ba/Rh NOx Traps for Design and Optimization

In this project a combined experimental and theoretical approach was taken to advance our understanding of lean NOx trap (LNT) technology. Fundamental kinetics studies were carried out of model LNT catalysts containing variable loadings of precious metals (Pt, Rh), and storage components (BaO, CeO{sub 2}). The Temporal Analysis of Products (TAP) reactor provided transient data under well-characterized conditions for both powder and monolith catalysts, enabling the identification of key reaction pathways and estimation of the corresponding kinetic parameters. The performance of model NOx storage and reduction (NSR) monolith catalysts were evaluated in a bench scale NOx trap using synthetic exhaust, with attention placed on the effect of the pulse timing and composition on the instantaneous and cycle-averaged product distributions. From these experiments we formulated a global model that predicts the main spatio-temporal features of the LNT and a mechanistic-based microkinetic models that incorporates a detailed understanding of the chemistry and predicts more detailed selectivity features of the LNT. The NOx trap models were used to determine its ability to simulate bench-scale data and ultimately to evaluate alternative LNT designs and operating strategies. The four-year project led to the training of several doctoral students and the dissemination of the findings as 47 presentations in conferences, catalysis societies, and academic departments as well 23 manuscripts in peer-reviewed journals. A condensed review of NOx storage and reduction was published in an encyclopedia of technology.

54 ENVIRONMENTAL SCIENCES↗

Analytical design and performance studies of the nuclear light bulb engine

Analytical studies were conducted to investigate in detail the heat balance characteristics of the nuclear light bulb engine. Distributions of energy deposition to all engine components from the fission process, conduction and convection, and thermal radiation were considered. Where uncertainties in basic data or heat transfer characteristics were encountered, ranges of heat loads were calculated and reference values were selected. The influence of these heat loads on engine performance, space radiator requirements, and cooling sequence and cooling circuit designs was determined. The analyses resulted in revisions to the previously reported reference engine characteristics, principally in the heat loads to some engine components and in the cooling sequence. These revisions were incorporated in the engine dynamics digital computer simulation program. No significant changes occurred in the dynamic response of the engine to perturbations in fuel injection rate, reactivity or exhaust nozzle area.

Rodgers, R. J.↗