Performance Evaluation of Counter-Based Dynamic Load Balancing Schemes for Massive Contingency Analysis with Different Computing Environments

Contingency analysis is a key function in the Energy Management System (EMS) to assess the impact of various combinations of power system component failures based on state estimation. Contingency analysis is also extensively used in power market operation for feasibility test of market solutions. High performance computing holds the promise of faster analysis of more contingency cases for the purpose of safe and reliable operation of today’s power grids with less operating margin and more intermittent renewable energy sources. This paper evaluates the performance of counter-based dynamic load balancing schemes for massive contingency analysis under different computing environments. Insights from the performance evaluation can be used as guidance for users to select suitable schemes in the application of massive contingency analysis. Case studies, as well as MATLAB simulations, of massive contingency cases using the Western Electricity Coordinating Council power grid model are presented to illustrate the application of high performance computing with counter-based dynamic load balancing schemes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Statistical Performance Evaluation Of Soft Seat Pressure Relief Valves

Risk-based inspection methods enable estimation of the probability of failure on demand for spring-operated pressure relief valves at the United States Department of Energy's Savannah River Site in Aiken, South Carolina. This paper presents a statistical performance evaluation of soft seat spring operated pressure relief valves. These pressure relief valves are typically smaller and of lower cost than hard seat (metal to metal) pressure relief valves and can provide substantial cost savings in fluid service applications (air, gas, liquid, and steam) providing that probability of failure on demand (the probability that the pressure relief valve fails to perform its intended safety function during a potentially dangerous over pressurization) is at least as good as that for hard seat valves. The research in this paper shows that the proportion of soft seat spring operated pressure relief valves failing is the same or less than that of hard seat valves, and that for failed valves, soft seat valves typically have failure ratios of proof test pressure to set pressure less than that of hard seat valves.

42 ENGINEERING↗

Review on Seismic Rehabilitation of a 56-Story RC Tall Building having Shear Wall System Based on A Nonlinear Dynamic Performance Evaluation

Tehran tower is a 56 story reinforced concrete tall building consisting of three wings with identical plan dimensions each approximately 48 meters by 22 meters. The three wings are at 120 degree from each other and have no expansions/seismic Joints. This paper contains the consideration of the retrofitting of the Tehran tower based on the findings of an exhaustive investigation of the nonlinear performance evaluation efforts. It has tried to show the procedure followed, methodologies utilized, and the results obtained for life-safety and collapse-prevention evaluation of the building. More over the weak zones of the structure due to analysis results are introduced and appropriate retrofit technique for satisfaction related life-safety and collapse-prevention criteria is presented. Actually in this project to improve the local behavior of coupling panels which are located regularly in main walls and definitely have been recognized as the most vulnerable structural elements, making use of steel plates which are connected to concrete members by chemical anchors has been used as the best retrofitting method for this case. Therefore in the final section of this paper it has been tried to explain the professional practical method utilized to perform the mentioned retrofitting project.

36 MATERIALS SCIENCE↗

Implementation and Performance Evaluation of a Community-Scale Adobe Evaporative Cooling Chamber for Vegetable Preservation

The construction of evaporative coolers in remote areas can increase the longevity of vegetables, improving food security and the local economy of small farmers in remote, impoverished communities without access to electricity. This work presents a 1:1 scale prototype of an 8 m 3 (2.1 × 2.1 × 2.3 m) stabilized adobe evaporative cooler, with a design based on the appropriate technology framework, and it was built as a chamber using double adobe walls, filled with wet sand, to induce evaporative cooling. Furthermore, the paper presents the prototype’s performance evaluation. The tests were carried out in the dry and wet states, with different volumes of water. The results show good performance compared with other prototypes, although the optimum watering volume could not be determined because of the high climate variance (outside temperature and humidity) that prevented the repetition of the experiments in identical operating conditions. Stabilized adobe proved to be a good choice for use in the cooler, even when subject to moisture accumulation, indicating an estimated long lifetime for the cooler. The data obtained about the efficiency of evaporative cooling show that the cooler, as expected, has its best performance on the hottest and driest days, reducing the internal temperature (up to 13.24 °C) and managing to keep the internal humidity. The cost, efficiency, durability, and replicability make the proposed evaporative cooler a feasible solution for food preservation.

42 ENGINEERING↗

On the validity and limitations of 1D model for heat and mass transfer performance evaluation in a multilayer binder-free desiccant dehumidifier: isothermal dehumidification with internal cooling

Efficient humidity control is essential for maintaining indoor thermal comfort, yet conventional vapor-compression-based dehumidifiers are energy-intensive. Employing separate sensible and latent cooling through desiccant-coated heat exchangers (DCHEs) combined with evaporative coolers offers energy savings of up to 80 % compared to conventional systems. However, the dehumidification performance of DCHEs remains limited due to the use of polymer binders for coating desiccant materials onto heat exchange surfaces. In our previous study, we developed a multilayer fixed-bed binder-free desiccant dehumidifier (MFBDD) that demonstrated high dehumidification capacity and low pressure drop compared to rotary desiccant wheels. Nevertheless, its potential for further enhancement through internal cooling and the use of step-shaped adsorption isotherms has not been explored. In this study, a physics-based one-dimensional (1D) transient model is developed and validated to capture the coupled heat and mass transfer processes in the MFBDD and extended to simulate internal cooling using a high-capacity composite metal–organic framework, MIL-101/GO-6 (water uptake ≈1.6 g/g within 35–47 % RH). The model enables detailed analysis of local air and bed temperature dynamics and quantifies how internal cooling affects the dehumidification performance under a wide range of operating conditions. Results show that integrating internal cooling and using MIL-101/GO-6 enhance mass adsorbed, moisture removal capacity, and dehumidification effectiveness by 50 %–99 % compared with the M.S. Gel baseline. The study further reveals that achieving near-isothermal operation requires simultaneous enhancement of the convective heat transfer coefficient and heat exchange surface area. In conclusion, this work provides the first detailed physical insight into the interplay between internal cooling and step-shaped isotherms in a binder-free desiccant device and establishes a validated modeling framework for scaling up and system-level performance evaluation of next-generation energy-efficient dehumidification systems.

Heat and mass transfer↗

Synthesis and Performance Evaluation of Unsaturated Polyester Blends of Resins and Its Application on Non-woven/Fabric Jute Fibers Reinforced Composites

The present study focuses on the generation of eco-friendly value added product by utilizing bio-based material as reinforced and matrix phase. Processing of soy and alkyd resin as matrix was carried out by utilization of soy flour and Ricinodendron heudelotii oil, followed essential modification in few inferior properties of soy flour resin by blending with alkyd resin. Separate sets of resin were prepared by maintaining 0%, 5% and 10% of alkyd resin in 100 g of soy flour resin respectively in each set to attain a comparative study on performance of prepared sets of resin blend. Subsequently, performance evaluation of polyester blends was evaluated by processing with non-woven/fabric jute fibers reinforced composites. The blend of R. heudelotii oil based alkyd and soy-flour resin in processing of composites was the noval approach of the study. The resins blend were characterized by FT–IR, viscosity and zeta potential measurements while thermo-mechanical analyses, water absorbancy and surface analyses were performed in composites. Significant increases noticed in the viscosity of blend, the blend containing 10% alkyd resin is two times more viscous compared to soy-flour resin. Furthermore, improvement in properties including water absorption, thermo-mechanical properties and better fiber-matrix interfacial adhesion of the composite could be observed. Higher glass transition temperature T{sub g} value i.e. 126.8 °C obtained for composites with 10% blend as matrix might emphasizes on increase of the degree of cross linking provided by the α-eleostearic fatty acid chain moiety. The enhancements in properties indicate extending opportunities for fiber-reinforced composites in several industries including building material, furniture, aerospace, nano etc.

36 MATERIALS SCIENCE↗

Performance Evaluation of Undulator Radiation at CEBAF

The performance of undulator radiation (UR) at CEBAF with a 3.5 m helical undulator is evaluated and compared with APS undulator-A radiation in terms of brilliance, peak brilliance, spectral flux, flux density and intensity distribution.

43 PARTICLE ACCELERATORS↗

Performance Evaluation of High-Temperature Ultrasonic Communication System

Ultrasonic communication is a technique that allows transmitting information through a solid material such as tubes or bars using high-frequency elastic waves. The communication channels often extend into a high-temperature range in the field of power, oil, or nuclear industry. When the temperature is taken into consideration, the ultrasonic wave propagation through the solid channel is complex and unpredictable. It is necessary to study the influence of temperature on the ultrasonic guided wave to improve ultrasonic communication. In this study, a temperature control system is assembled to adjust the temperature of a steel pipe channel ranging from room temperature to 150 degrees C. The temperature performance evaluation is conducted to estimate the signal-to-noise ratio (SNR) and bit error rate (BER) of transferring the ultrasonic signal. The work aims to develop a reliable ultrasonic communication system in a high-temperature environment. The system temperature can be maintained at 150 degrees C and the LiNbO3 transducers are used as transmitters and receivers. No power amplifier is used in the communication system. The high-temperature ultrasonic communication system (HT-UCS) is feasible at 150 degrees C and can achieve a bit rate of 10 kbps without any error.

HT-UCS↗

Smith Newton Vehicle Performance Evaluation (Revised) [Brochure]

The Fleet Test and Evaluation Team at the U.S. Department of Energy's National Renewable Energy Laboratory is evaluating and documenting the performance of electric and plug-in hybrid electric drive systems in medium-duty trucks across the nation. Through this project, Smith Electric Vehicles will build and deploy 500 all-electric medium-duty trucks. The trucks will be deployed in diverseclimates across the country.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PERFORMANCE EVALUATION OF CEILING RADIANT COOLING SYSTEM IN COMPOSITE CLIMATE

Radiant cooling systems are proving to be an energy efficient solution due to higher thermal capacity of cooling fluid especially for the buildings that require individual zone controls and where the latent loads are moderate. The Conventional air conditioners work at very low temperature i.e.5-8 c (refrigerant evaporator inlet) while the radiant cooling systems, also referred as high temperature cooling system, work at high temperatures i.e. 14-18 c. The radiant cooling systems can maintain lower MRT (Mean Radiant Temperature) as ceiling panels maintain uniform temperature gradient inside room and provide higher human comfort. The radiant cooling systems are relatively new systems and their operation and energy savings potential are not quantified for a large number of buildings and operational parameters. Moreover, there are only limited numbers of whole building simulation studies have been carried out for these systems to have a full confidence in the capability of modelling tools to simulate these systems and predict the impact of various operating parameters. Theoretically, savings achieve due to higher temperature set point of chilled water, which reduces chiller-running time. However, conventional air conditioner runs continuously to maintain requisite temperature. In this paper, experimental study for performance evaluation of radiant cooling system carried out on system installed at Malaviya National Institute of Technology Jaipur. This paper quantifies the energy savings opportunities and effective temperature by radiant cooling system at different chilled water flow rates and temperature range. The data collected/ analysed through experimental study will used for calibration and validation of system model of building prepared in building performance simulation software. This validated model used for exploring optimized combinations of key parameters for composite climate. These optimized combinations will used in formulation of radiant cooling system operations control strategy.

Ceiling Panels↗

Navistar eStar Vehicle Performance Evaluation - Cumulative (Brochure)

The Fleet Test and Evaluation Team at the U.S. Department of Energy's National Renewable Energy Laboratory is evaluating and documenting the performance of electric and plug-in hybrid electric drive systems in medium duty trucks across the nation. U.S. companies participating in this evaluation project received funding from the American Recovery and Reinvestment Act to cover part of the cost of purchasing these vehicles. Through this project, Navistar will build and deploy all-electric medium-duty trucks. The trucks will be deployed in diverse climates across the country.

33 ADVANCED PROPULSION SYSTEMS↗

Navistar eStar Vehicle Performance Evaluation - Cumulative; Energy Efficiency & Renewable Energy (EERE), NREL (National Renewable Energy Laboratory)

The Fleet Test and Evaluation Team at the U.S. Department of Energy's National Renewable Energy Laboratory is evaluating and documenting the performance of electric and plug-in hybrid electric drive systems in medium duty trucks across the nation. U.S. companies participating in this evaluation project received funding from the American Recovery and Reinvestment Act to cover part of the cost of purchasing these vehicles. Through this project, Navistar will build and deploy all-electric medium-duty trucks. The trucks will be deployed in diverse climates across the country. This cumulative report covers the project from initiation through the second quarter of 2013.

33 ADVANCED PROPULSION SYSTEMS↗

Navistar eStar Vehicle Performance Evaluation – 4th Quarter 2013; Energy Efficiency & Renewable Energy (EERE), Vehicle Technologies Office (VTO)

The Fleet Test and Evaluation Team at the U.S. Department of Energy's National Renewable Energy Laboratory is evaluating and documenting the performance of electric and plug-in hybrid electric drive systems in medium duty trucks across the nation. U.S. companies participating in this evaluation project received funding from the American Recovery and Reinvestment Act to cover part of the cost of purchasing these vehicles. Through this project, Navistar will build and deploy all-electric medium-duty trucks. The trucks will be deployed in diverse climates across the country.

33 ADVANCED PROPULSION SYSTEMS↗

Navistar eStar Vehicle Performance Evaluation -- Cumulative; NREL (National Renewable Energy Laboratory)

The Fleet Test and Evaluation Team at the U.S. Department of Energy's National Renewable Energy Laboratory is evaluating and documenting the performance of electric and plug-in hybrid electric drive systems in medium duty trucks across the nation. U.S. companies participating in this evaluation project received funding from the American Recovery and Reinvestment Act to cover part of the cost of purchasing these vehicles. Through this project, Navistar will build and deploy all-electric medium-duty trucks. The trucks will be deployed in diverse climates across the country.

33 ADVANCED PROPULSION SYSTEMS↗

Navistar eStar Vehicle Performance Evaluation - 1st Quarter 2014; Energy Efficiency & Renewable Energy (EERE), Vehicle Technologies Office (VTO)

The Fleet Test and Evaluation Team at the U.S. Department of Energy's National Renewable Energy Laboratory is evaluating and documenting the performance of electric and plug-in hybrid electric drive systems in medium duty trucks across the nation. U.S. companies participating in this evaluation project received funding from the American Recovery and Reinvestment Act to cover part of the cost of purchasing these vehicles. Through this project, Navistar will build and deploy all-electric medium-duty trucks. The trucks will be deployed in diverse climates across the country.

33 ADVANCED PROPULSION SYSTEMS↗

Smith Newton Vehicle Performance Evaluation - Cumulative (Brochure)

The Fleet Test and Evaluation Team at the U.S. Department of Energy's National Renewable Energy Laboratory is evaluating and documenting the performance of electric and plug-in hybrid electric drive systems in medium-duty trucks across the nation. U.S. companies participating in this evaluation project received funding from the American Recovery and Reinvestment Act to cover part of the cost of purchasing these vehicles. Through this project, Smith Electric Vehicles is building and deploying 500 all-electric medium-duty trucks that will be deployed by a variety of companies in diverse climates across the country.

33 ADVANCED PROPULSION SYSTEMS↗

Smith Newton Vehicle Performance Evaluation - Gen 2 - Cumulative (Brochure)

The Fleet Test and Evaluation Team at the U.S. Department of Energy's National Renewable Energy Laboratory is evaluating and documenting the performance of electric and plug-in hybrid electric drive systems in medium-duty trucks across the nation. U.S. companies participating in this evaluation project received funding from the American Recovery and Reinvestment Act to cover part of the cost of purchasing these vehicles. Through this project, Smith Electric Vehicles is building and deploying 500 all-electric medium-duty trucks that will be deployed by a variety of companies in diverse climates across the country.

33 ADVANCED PROPULSION SYSTEMS↗

Smith Newton Vehicle Performance Evaluation - Gen2 - 1Q2014 (Brochure)

The Fleet Test and Evaluation Team at the U.S. Department of Energy's National Renewable Energy Laboratory is evaluating and documenting the performance of electric and plug-in hybrid electric drive systems in medium-duty trucks across the nation. U.S. companies participating in this evaluation project received funding from the American Recovery and Reinvestment Act to cover part of the cost of purchasing these vehicles. Through this project, Smith Electric Vehicles is building and deploying 500 all-electric medium-duty trucks that will be deployed by a variety of companies in diverse climates across the country.