Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peak load reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Influence of Phase-Change Materials and Operating Periods on Load Shifting for Thermal Storage Heat Pumps in European Climate Zones

As the reliance on heat pumps (HPs) for space conditioning increases worldwide, ex-tensive grid strains during utility peak hours are expected. Significant research efforts focus on investigating the use of integrated thermal energy storage (TES) systems to reduce peak energy demands. Conventionally, TES systems are often integrated to store and provide either cooling or heating, but not both. In this work, a single room-temperature phase-change material (PCM)-TES was integrated for dual-mode opera-tion with an R290 air-to-water 10.5 kW (3-Ton) HP. Two PCM melting temperatures (17°C, 22°C) were assessed to investigate their impact on system performance and cost reductions for Milan, Italy (4A); Barcelona, Spain (3A); and Oslo, Norway (6A). HP and HP-TES performance maps were generated using Modelica-based transient models and co-simulated with a prototype residential building using the Spawn of En-ergyPlusTM with simple rule-based controls. Our simulations indicate that PCM-17°C provided annual cost savings at higher peak-to-off-peak cost ratios, as the demand re-duction dominated the savings potential. The recharge energy costs and requirements became more dominant at lower cost ratios, making PCM-22°C more beneficial at lower cost ratios. Finally, despite Oslo's heating-dominated climate, the utility peak hours favor cooling demand reductions, making PCM-17°C more appealing. In all cases, the cost savings potential stabilized between 4 – 10% regardless of cost ratio, suggesting that system-level component and operation control optimization is required to maximize cost savings further.

25 ENERGY STORAGE↗

A Finite Element Study of Stress Reduction Techniques in REBCO HTS Conductor on a Round Cable (CORC) Cable

ReBCO high-temperature superconducting (HTS) tape is critical for achieving the high magnetic fields needed in next-generation particle accelerators. Enhancing the mechanical performance of ReBCO tape increases its critical current by reducing internal stress, especially in the superconducting layer. A finite element study examined how copper layer properties affect stress in ReBCO conductor on a round core (CORC) cables. The cable was modeled as a doubly supported beam under uniform compressive stresses."cable was modeled as a doubly supported beam under uniform load to simulate bending. A staged modeling approach from a single tape to a six-layer stack enabled validation and efficient parameter studies. Increasing the yield strength and Young s modulus of the copper layers reduced peak stress in the ReBCO layer. These results support development of improved tape stacks for high-field accelerator magnets

Mueller, Scott [Northern Illinois U.]↗

A Unified Beam-Dynamics and Hardware Design Framework for Hybrid Nonlinear-Kicker Injection in NSLS-II

Nonlinear kickers (NLKs) enable off-axis injection in ultralow-emittance storage rings by providing a strong kick to the injected beam while remaining nearly transparent to the stored beam. In hybrid schemes, a conventional four-kicker bump defines the injected trajectory, and the NLK reduces the first-turn action under constrained beam offset and optics conditions. Effective operation additionally requires stable and reproducible first-turn injection trajectories. We develop a compact action–angle framework that expresses NLK dynamics in terms of Courant–Snyder invariants and yields an analytical bound on achievable action reduction. This formulation provides direct design rules for NLK placement, phase advance, injected-beam offset, and kicker field profile. Within this framework, we identify the 8-wire NLK as a practical baseline and extend its design by relaxing the square-geometry constraint, enabling inward shifting of the off-axis field peak while preserving on-axis field and gradient cancellation. Application to the NSLS-II lattice shows how aperture, pulsed-power, and mechanical constraints combine to determine a coupled design solution. Multi-turn tracking confirms that candidate NLK locations maintain sufficient stay-clear (aperture-clearance) margin, while the optimized wire geometry reduces the required current and Lorentz force load. The results establish a unified approach for NLK-assisted injection design and provide a practical pathway for upgrades in diffraction-limited storage rings.

36 MATERIALS SCIENCE↗

Fuel Behavior Implications of Reactor Design Choices in Pressurized Water SMRs

Small pressurized water reactors (PWRs) can feature boron free operation, natural circulation mode, reduced height assemblies and/or long refueling cycles. This paper attempts to explore core design optimization for each of these design evolutions. In consequence, five core design layouts are developed incorporating boron free operation with continuous control rods insertion, natural circulation with low burnup/low power density design, natural circulation with high burnup/low power density design, forced circulation with standard core power density design, and forced circulation with high power density design. These cores’ performance is compared to a standard 4-loop PWR. The design process aims to improve the fuel cycle cost under safety constraints through core design optimization using CASMO4E/SIMULATE3 reactor physics codes and FRAPCON4.1 fuel performance assessment tool. Core modeling assumes standard 17x17 PWR fuel assemblies loaded with low enriched uranium (LEU) up to 5wt% or LEU+ (i.e., below 10wt% enrichment) pellets with gadolinium oxide (Gd2O3) as the burnable poison. Satisfactory core and fuel performances are obtained for all the designed cores under steady state and considered overpower transients. For low power density operation, long cycle lengths are achieved reaching a 2.5- and a 5-year cycles and peak rod-average burnup is pushed to 83 MWd/kgU. Other cycle lengths are maintained at 18 months. Boron free operation exhibits the ability to achieve longer cycle lengths at the cost of higher peaking factors leading to high local power and fuel temperatures which prevents sizable power uprates and is deemed uneconomical. Fuel assembly height reduction allows coolant velocity retrofit which enables higher core power density without violating structural integrity of the fuel assembly. As a result, a core power density of 123 kW/l is reached where total cladding hoop strain becomes the limiting parameter.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Rapid detection of rare events from in situ X-ray diffraction data using machine learning

High-energy X-ray diffraction methods can non-destructively map the 3D microstructure and associated attributes of metallic polycrystalline engineering materials in their bulk form. These methods are often combined with external stimuli such as thermo-mechanical loading to take snapshots of the evolving microstructure and attributes over time. However, the extreme data volumes and the high costs of traditional data acquisition and reduction approaches pose a barrier to quickly extracting actionable insights and improving the temporal resolution of these snapshots. This article presents a fully automated technique capable of rapidly detecting the onset of plasticity in high-energy X-ray microscopy data. The technique is computationally faster by at least 50 times than the traditional approaches and works for data sets that are up to nine times sparser than a full data set. This new technique leverages self-supervised image representation learning and clustering to transform massive data sets into compact, semantic-rich representations of visually salient characteristics ( e.g. peak shapes). These characteristics can rapidly indicate anomalous events, such as changes in diffraction peak shapes. It is anticipated that this technique will provide just-in-time actionable information to drive smarter experiments that effectively deploy multi-modal X-ray diffraction methods spanning many decades of length scales.

Zheng, Weijian↗

Performance Assessment of a Heat Pump Integrated with Thermal Energy Storage in Cooling & Heating Modes

Thermal Energy Storage (TES) systems have demonstrated significant potential to manage the fluctuating nature of energy demand and shifting peak loads. This technology has made significant recent advances, including new research on the integration of TES with residential and commercial Heating, Ventilation, and Air-Conditioning (HVAC) systems. In this paper, we present the use of a novel laboratory assessment framework for a prototype heat pump system integrated with latent heat phase change material-based TES. The assessment framework consists of 22 total test points (11 heating, 11 cooling) using psychrometric conditions from AHRI Standard 210/240 and includes transient conditions to evaluate TES charging and discharging modes. In addition, both continuous mode and cyclic mode were evaluated for charging and discharging to explore the benefits to TES heat transfer from repeated transient operation. The ambient conditions evaluated include heating mode charging at cold-climate heat pump conditions when winter-peaking utilities may most require demand reduction (H4Full conditions, 5°F/-15°C) and cooling mode charging at high ambient temperature that may occur during times of day when excess solar power generation results in low-cost electricity (105°F/40.6°C). The work demonstrates the demand reduction capabilities of integrating TES with HVAC, including up to 44% in cooling mode and 60% in heating mode compared to conventional HVAC equipment without TES.

25 ENERGY STORAGE↗

From Fundamental Interfacial Reaction Kinetics to Macroscopic Current–Voltage Characteristics: Case Study of Solid Acid Fuel Cell Limitations and Possibilities

The unique properties of solid acid electrolytes, in particular CsH 2 PO 4 , are in many ways ideal for fuel cell operation. However, the technology is constrained by high cathode overpotentials. Here a simplified cathode geometry is employed to obtain the fundamental electrochemical parameters (exchange current density and charge transfer coefficient) describing the oxygen reduction reaction (ORR) at the CsH 2 PO 4 -Pt-gas interface. The parameters are incorporated into a 1D model of the voltage–current characteristics of realistic SAFC cathodes, which reproduced the measured polarization behavior of such cathodes without recourse to fitting adjustable parameters. Following this validation, the model is utilized to evaluate the impact of changes to cathode properties, microstructure, and operating conditions. Of these, the charge transfer coefficient, measured to have a value of ≈0.6 for ORR on Pt in the SAFC cathode environment, is found to have the greatest impact on power output. Nevertheless, even without material modifications, a combination of microstructural and operational modifications are identified with projected performance metrics meeting Department of Energy targets (0.8 V at 300 mA cm –2 , and peak power density of 1 W cm –2 ), albeit at high Pt loadings. However, the analysis indicates that truly meaningful advances will likely necessitate the discovery of alternative ORR catalysts.

36 MATERIALS SCIENCE↗

ASPIRE Aerodynamic Models and Flight Performance

NASA's Advanced Supersonic Parachute Inflation Research Experiments (ASPIRE) project was established to test full-scale supersonic parachutes at Mars-relevant conditions, as a risk-reduction activity for NASA's upcomingMars2020 mission. Deployment and inflation of Disk-Gap-Band (DGB) parachutes were examined at Mach number and dynamic pressure conditions relevant to Mars2020, using a sounding rocket platform. The flight tests examined two parachutes: a build-to-print version of the parachute used by the Mars Science Laboratory and a strengthened version of this parachute that has the same geometry but differs in materials and construction. The first flight test (SR01) of the built-to-print parachute took place on October 4, 2017, followed by the first test of the strengthened parachute during flight SR02 on March 31, 2018. A second test of the strengthened parachute with a higher target load, SR03, took place on September 7, 2018. Over the sequence of the three tests, the parachute was exposed to increasing aerodynamic loads with the peak load during SR03 being significantly larger than is expected during a Martian descent. All three tests were successful: the parachute deployment and inflation occurred at the intended conditions, the measurement systems performed as designed and provided the data, and the parachutes survived the aerodynamic loads they were exposed to. The flight tests yielded valuable data on parachute forces and high-speed imagery of the deployment and inflation process.

Parachute↗

Charger 1: A New Facility for Z-Pinch Research

Charger 1 is a multipurpose pulsed power laboratory located on Redstone Arsenal, with a focus on fusion propulsion relevant experiments involving testing z-pinch diodes, pulsed magnetic nozzle and other related physics experiments. UAH and its team of pulsed power researchers are investigating ways to increase and optimize fusion production from Charger 1. Currently the team has reached high-power testing. Due to the unique safety issues related to high power operations the UAH/MSFC team has slowed repair efforts to develop safety and operations protocols. The facility is expected to be operational by the time DZP 2017 convenes. Charger 1 began life as the Decade Module 2, an experimental prototype built to prove the Decade Quad pinch configuration. The system was donated to UAH by the Defense Threat Reduction Agency (DRTA) in 2012. For the past 5 years a UAH/MSFC/Boeing team has worked to refurbish, assemble and test the system. With completion of high power testing in summer 2017 Charger 1 will become operational for experimentation. Charger 1 utilizes a Marx Bank of 72 100-kV capacitors that are charged in parallel and discharged in series. The Marx output is compressed to a pulse width of approximately 200 ns via a pulse forming network of 32 coaxial stainless steel tubes using water as a dielectric. After pulse compression a set of SF6 switches are triggered, allowing the wave front to propagate through the output line to the load. Charger 1 is capable of storing 572-kJ of energy and time compressing discharge to less than 250 ns discharge time producing a discharge of about 1 TW of discharge with 1 MV and 1 MA peak voltage and current, respectively. This capability will be used to study energy yield scaling and physics from solid density target as applied to advanced propulsion research.

Taylor, Brian↗

Recharge Demand Mitigation for Latent Heat Thermal Energy Storage at Off-peak Hours

The utilization of integrated heat pump thermal energy storage (HP-TES) systems for space conditioning applications can reduce electrical power demand and achieve utility savings resulting from peak shaving and load shifting. However, issues arise when the energy required to recharge the TES exceeds the shifted energy demand, especially in extreme climates where high-temperature lifts between the outdoor air conditions and phase-change materials (PCMs) during recharging may occur. In this work, a single room-temperature (22°C) PCM-TES is integrated into a single-speed heat pump system using a secondary hydronic loop where the TES is recharged using the outdoor unit during off-peak hours. Three recharge strategies were investigated as potential pathways to reduce recharging power demand: (i) considering different heat source/sink temperatures, (ii) using a variable-speed compressor, and (iii) using a variable-speed pump. Simulations were conducted using Modelica for HP-TES recharging at different heat source/sink temperatures from -30 – 20℃ in heating mode and 0 – 30℃ in cooling mode. Results show that the most effective recharge demand reduction strategy is an HP-TES system using a single-speed compressor with a variable-speed pump for the hydronic loop run at preferable heat source/sink temperatures when the temperature lifts were reduced. Utilizing a variable-speed compressor for the HP-TES system reduced recharge time in extreme cases at the cost of additional compressor power input. The findings motivate potential control strategies that minimize recharge energy and maximize peak energy savings, hence reducing overall operating costs and annual energy consumption for HP-TES systems for space conditioning applications.

25 ENERGY STORAGE↗

Response Of Mineralizing And Non-Mineralizing Bone Cells To Fluid Flow: An In Vitro Model For Mechanotransruction

Humans reach peak bone mass at age 30. After this point, we lose 1 to 2 percent of bone mass each decade. In the microgravity environment of space, astronauts lose bone mass at an accelerated rate of 1 to 2 percent each month. When astronauts travel to Mars, they may be in space for as long as 3 years. During this time, they may lose about half of their bone mass from weight-bearing bones. This loss may be irreversible. The drastic loss in bone that astronauts experience in space makes them much more vulnerable to fractures. In addition, the corresponding removal of calcium from bone results in higher levels of calcium in the blood, which increases the risk of developing kidney stones. Currently, studies are being conducted which investigate factors governing bone adaptation and mechanotransduction. Bone is constantly adapting in response to mechanical stimuli. Increased mechanical loading stimulates bone formation and suppresses bone resorption. Reduction in mechanical loading caused by bedrest, disuse, or microgravity results in decreased bone formation and possibly increased bone resorption. Osteoblasts and osteoclasts are the two main cell types that participate in bone remodeling. Osteoblasts are anabolic (bone-forming) cells and osteoclasts are catabolic (bone-resorbing) cells. In microgravity, the activity of osteoblasts slows down and the activity of osteoclasts may speed up, causing a loss of bone density. Mechanotransduction, the molecular mechanism by which mechanical stimuli are converted to biochemical signals, is not yet understood. Exposure of cells to fluid flow imposes a shear stress on the cells. Several studies have shown that the shear stress that results from fluid flow induces a cellular response similar to that induced by mechanical loading. Thus, fluid flow can be used as an in vitro model to simulate the mechanical stress that bone cells experience in vivo. Previous in vitro studies have shown that fluid flow induces several responses in osteoblasts, including increased proliferation, osteoblastic differentiation, alkaline phosphatase activity, and production of nitric oxide, prostaglandins, and osteopontin. Several proteins have been implicated in osteoblastic mechanotransduction including Bone Morphogenetic Protein-2 (BMP-2), parathyroid hormone, 1,25-dihydroxyvitamin D3 receptor, osteopontin (OPN), osteoprotegerin (OPG), and alkaline phosphatase (AP). We will characterize relative levels of each protein in mineralizing or non-mineralizing MC3T3 osteoblastic cells that have been exposed to fluid flow compared to non-fluid flow using immunofluorescent staining and two- photon laser microscopy as well as western blotting. Because calcium-mediated pathways are important in osteoblastic signaling, we will transfect MC3T3 cells with cameleon probes for Ca2+ containing YFP and CFP. Results will be analyzed using FRET/FLIM to study differential release of intracellular Ca(2+) in response to fluid flow and conditions inducing matrix mineralization. In addition, we plan to conduct several microarray experiments to determine differential gene expression in MC3T3 cells in response to fluid flow and conditions inducing mineralization.

Makuch, Lauren A.↗

Increased renal tubular sodium reabsorption during exercise-induced hypervolemia in humans

We tested the hypothesis that renal tubular Na(+) reabsorption increased during the first 24 h of exercise-induced plasma volume expansion. Renal function was assessed 1 day after no-exercise control (C) or intermittent cycle ergometer exercise (Ex, 85% of peak O(2) uptake) for 2 h before and 3 h after saline loading (12.5 ml/kg over 30 min) in seven subjects. Ex reduced renal blood flow (p-aminohippurate clearance) compared with C (0.83 +/- 0.12 vs. 1.49 +/- 0.24 l/min, P < 0.05) but did not influence glomerular filtration rates (97 +/- 10 ml/min, inulin clearance). Fractional tubular reabsorption of Na(+) in the proximal tubules was higher in Ex than in C (P < 0.05). Saline loading decreased fractional tubular reabsorption of Na(+) from 99.1 +/- 0.1 to 98.7 +/- 0.1% (P < 0.05) in C but not in Ex (99.3 +/- 0.1 to 99.4 +/- 0.1%). Saline loading reduced plasma renin activity and plasma arginine vasopressin levels in C and Ex, although the magnitude of decrease was greater in C (P < 0.05). These results indicate that, during the acute phase of exercise-induced plasma volume expansion, increased tubular Na(+) reabsorption is directed primarily to the proximal tubules and is associated with a decrease in renal blood flow. In addition, saline infusion caused a smaller reduction in fluid-regulating hormones in Ex. The attenuated volume-regulatory response acts to preserve distal tubular Na(+) reabsorption during saline infusion 24 h after exercise.

NASA Discipline Cardiopulmonary↗

Aerothermal Analysis of the Rocket Lab Venus Probe Heatshield

This document provides an overview of the aerothermodynamic analyses performed by the Aerothermodynamics Branch at NASA Langley Research Center for the Rocket Lab Venus Probe (RLVP). In addition to defining the baseline heating environment to the heatshield, this document pursues the experimental validation of key physical models at RLVP-relevant conditions. This experimental validation analysis, which captures the model form uncertainty, is used as one of two primary components of the margin assessment, where the other component is the parametric uncertainty. These model form (experimental) and parametric uncertainty components are used to construct a spatial and time varying margin for the heating to the RLVP heatshield. The margin is evaluated as the sum of the parametric and model form uncertainty components. The model form uncertainty is defined as the difference between the RLVP-relevant measurements and their simulations, using the upper limit uncertainty bounds for both the measurements and simulations in the comparisons. The differences in the dominant physics in the stagnation region and flank lead to the separate RLVP-relevant measurements for assessing the model form uncertainty in these two regions. These regions are addressed as follows: Stagnation Region Heating Environment: For the high-temperature stagnation-region, both the radiative heating and impact of blowing on convective heating are significant, while the impacts of turbulence and roughness are negligible. Coupled radiation and ablation LAURA/HARA solutions with ray-tracing provide the radiative heating over the entire vehicle, including the contributions from the Venus atmosphere and ablation species. Non-ablating LAURA simulations provide the convective heating. During the material-response computation typically used for TPS sizing, this non-ablating convective heating is corrected for the impact of ablation using the blowing correction. Coupled ablation LAURA simulations that capture finite-rate sur-face processes show that this blowing correction may be non-conservative over most of the heatshield. This non-conservatism is due to hydrogen recombination in the finite-rate surface model, which tends to increase the coupled ablation convective heating to near the non-ablating values, therefore making any reduction in the non-ablating value through the blowing correction non-conservative. This non-conservatism due to H catalysis is captured in the parametric component of the margin. The best available ground-test measurements that capture the impact of blowing on stagnation region convective heating, at RLVP-relevant conditions, indicate that the current blowing reduction model is non-conservative by up to 20% at RLVP-relevant blowing rates (the coupled blowing simulations were also non-conservative). Because of the relatively low velocity of the ground tests and the non-Venus atmospheric chemistry, these measurements do not capture the chemistry and therefore do not inform the uncertainty due to H catalysis. However, they do capture the fluid mechanics of blowing. The non-conservatism of the blowing correction implied by these measurements is covered by the model form component of the margin, which leads to total margin values over 50%. For the radiative heating, the shock-tube informed bias approach suggests a model form uncertainty of roughly 20%, while the parametric uncertainty analysis suggests values over 100%. The combined stagnation-point radiation margin of over 100% leads to peak margined radiative heating values of over300 W/cm2, which remains small relative to the peak margined convective heating of nearly 2000 W/cm2. Based on this analysis, at the stagnation point, the peak margined heat rate is 2203 W/cm2 and the margined total heat load is 31.5 kJ/cm2 for the current nominal trajectory. Flank Heating Environment: The forebody flank (and near-shoulder) heating environment is dominated by the impact of turbulence, roughness augmentation, and ablation on the convective heating. An extensive collection of ground test measurements with RLVP-relevant turbulence and roughness is studied to show that the maximum difference between the simulated and measured convective heating is 5%. However, with the exception of the Holden measurements from the 1980s, these measurements do not include roughness elements extending into the supersonic region of the boundary layer, which is likely to occur for RLVP (due to the 45 degree sphere-cone geometry). The interaction between the supersonic flow and roughness could cause convective heating augmentation fundamentally different than for locally subsonic flow. Although these Holden measurements are consistent with the other measurements considered, another path was pursued to assure that the rough-ness height extending into supersonic flow does not fundamentally change the roughness augmentation. This additional path was a computational effort to resolve the roughness elements in the CFD grid, so that the interaction be-tween the roughness elements and locally supersonic flow may be simulated in detail. This roughness-resolved CFD simulation is feasible because of the RLVP forebody TPS’s patterned roughness, which may be approximated analytically, and because of the axisymmetric nominal flow field, which allows a narrow surface region to be simulated and therefore make the computational expense feasible. These grid-resolved roughness simulations, which are performed at actual RLVP flight conditions, result in heating augmentation values that are below the design approach for roughness augmentation. This provides evidence that the design approach for RLVP roughness augmentation is sufficient. Based on this analysis, at this flank or near-shoulder location, the peak margined total heat rate is 2088 W/cm2and the margined total heat load is 26.0 kJ/cm2for the current nominal trajectory. Heat flux, shear, pressure and heat transfer coefficient at the RLVP stagnation point and near shoulder location are evaluated for the entire trajectory, and curved fit to a functional form of F=AρB∞UC∞. These simplified relationships for the nominal and margined aerothermal environments are referred to as aerothermal indicators, and presented at the end of this document.

Christopher O Johnston↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗

Cruise-Efficient Short Takeoff and Landing (CESTOL): Potential Impact on Air Traffic Operations

The National Aeronautics and Space Administration (NASA) is investigating technological and operational concepts for introducing Cruise-Efficient Short Takeoff and Landing (CESTOL) aircraft into a future US National Airspace System (NAS) civil aviation environment. CESTOL is an aircraft design concept for future use to increase capacity and reduce emissions. CESTOL provides very flexible takeoff, climb, descent and landing performance capabilities and a high-speed cruise capability. In support of NASA, this study is a preliminary examination of the potential operational impact of CESTOL on airport and airspace capacity and delay. The study examines operational impacts at a subject site, Newark Liberty Intemational Airport (KEWR), New Jersey. The study extends these KEWR results to estimate potential impacts on NAS-wide network traffic operations due to the introduction of CESTOL at selected major airports. These are the 34 domestic airports identified in the Federal Aviation Administration's Operational Evolution Plan (OEP). The analysis process uses two fast-time simulation tools to separately model local and NAS-wide air traffic operations using predicted flight schedules for a 24-hour study period in 2016. These tools are the Sen sis AvTerminal model and NASA's Airspace Concept Evaluation System (ACES). We use both to simulate conventional-aircraft-only and CESTOL-mixed-with-conventional-aircraft operations. Both tools apply 4-dimension trajectory modeling to simulate individual flight movement. The study applies AvTerminal to model traffic operations and procedures for en route and terminal arrival and departures to and from KEWR. These AvTerminal applications model existing arrival and departure routes and profiles and runway use configurations, with the assumption jet-powered, large-sized civil CESTOL aircraft use a short runway and standard turboprop arrival and departure procedures. With these rules, the conventional jet and CESTOL aircraft are procedurally separated from each other geographically and in altitude during tenninal airspace approach and departure operations, and each use a different arrival runway. AvTeminal implements its unique Focal-point Scheduling Process to sequence, space and delay aircraft to resolve spacing and overtake conflicts among flights in the airspace and airport system serving KEWR. This Process effectively models integrated arrival and departure operations. AvTerminal assesses acceptance rates and delay magnitude and causality at selected locations, including en route outer boundary fixes, tenninal airspace arrival and departure boundary fixes, terminal airspace arrival merge and departure diverge fixes, and runway landing and takeoff runways. The analysis compares the resulting capacity impacts, flight delays and delay sources between CESTOL and conventional KEWR operations. AvTerminal quantitative results showed that CESTOL has significant capability to increase airport arrival acceptance rates (35-40% at KEWR) by taking advantage of otherwise underused airspace and runways where available. The study extrapolates the AvTerminal-derived KEWR peak arrival and departure acceptance rates to estimate capacity parameter values for each of the OEP airports in the ACES modeling of traffic through the entire NAS network. The extrapolations of acceptance rates allow full, partial or no achievement of CESTOL capacity gains at an OEP airport as determined by assessments of the degree to which local procedures allow leveraging of CESTOL capabilities. These assessments consider each OEP airport's runway geometries, runway system configurations, airport and airspace operations, and potential CESTOL traffic loadings. The ACES modeling, simulates airport and airspace spacing constraints imposed by airport runway system, terminal and en route air traffic control and traffic flow management operations using airport acceptance rates representing conventional-aircraft-only and CESTOL-mixed operations. CEOL aircraft are assumed to have Mach 0.8, and alternatively Mach 0.7, cruise speeds to examine compatibility with conventional aircraft operations in common airspace. The ACES results provides estimates of CESTOL delay impact NAS-wide and at OEP airports due to changes in OEP airport acceptance rates and changes in en route airspace potential conflict rates. Preliminary results show meaningful nationwide delay reductions (20%) due to CESTOL operations at 34 major domestic airports.

Couluris, G. J.↗

Thermal Protection System to Enable Ice Giant Aerocapture Mission for Delivering Both an Orbiter and an In Situ Probe

The Ice Giants have been identified as high priority science destinations in the last Decadal Survey [1] and could benefit from aerocapture as the primary method for orbit insertion [2]. A mass-efficient aerocapture system will enable the delivery of an orbiter along with an atmospheric probe (for in situ measurements to anchor global data collected by the orbiter) and possibly a lander at Triton [3]. Aerocapture could be executed either using low L/D rigid aeroshell with lift modulation (LMA) [4] or using deployable aeroshell using drag modulation (DMA) [3]. Nearly two decades ago, a NASA-funded team performed Neptune-Triton aerocapture studies with a mid-L/D lifting configuration [5] for achieving orbit using LMA. This study showed aerocapture challenges. Due to very high peak entry conditions combined with very high heat-load, a suite of TPS materials was required and this suite was deemed problematic from a qualification perspective, due test facility limitations. In the past 20 years, progress made in GN&C for lift-guided entry missions such as MSL, Orion EFT1, Mars 2020 and the upcoming Artemis missions, and the expertise in blunt body aerodynamics at large scale (~ 5m) has led the EDL community to conclude that aerocapture is a “go do” engineering activity and most technologies are in hand to propose missions with aerocapture [6] [7]. Aerocapture using DMA, currently in development, is an option for Ice Giant Missions. While DMA is simpler in some sense, due to ballistic entry and no need for lift-guided maneuvering, it has challenges and it’s maturity is lower. LMA and DMA both require one or more ablative Thermal Protection System (TPS) materials for the rigid aeroshell element. The ablative TPS needs to be robust and mass efficient due to the high heat loads and size of the rigid aeroshell. Currently, there are capable ablative thermal protection materials, e.g., Heatshield for Extreme Entry Environments Technology (HEEET), 3-D woven Mid-Density Carbon- Phenolic (3MDCP), and PICA (Phenolic-Impregnated Carbon Ablator) that are mature, i.e., at TRL 6 or higher. NASA also invested in Conformal PICA that was matured to TRL 5. Our goal is to evaluate the applicability of high TRL TPS and consider other design options. We first establish bounding aerocapture trajectories for a wide range of arrival conditions and the associated aerothermal environment. Based on the environments, we then determine the predicted TPS mass for the aeroshell [4]. In this presentation, we will outline the process by which we establish bounding aerocapture trajectories for hyperbolic excess velocities ranging from 27 km/s to 35 km/s, which are shown to be a range of velocities that can reduce the trip time from ~14 years to 8 years. The above velocity range translates to ~12 km/s to ~24 km/s arrival velocities at the planetary entry interface [2]. The velocity reduction required to achieve orbit ranges between ~2.5 km/s to 9.5 km/s for both Neptune and Triton. Propulsive insertion alone, due to the amount of fuel required to achieve the required velocity reduction, limits the science returned [2]. We establish the bounding aerocapture trajectories for a low L/D (~ 0.4) configuration for three different ballistic coefficients. The ballistic coefficient range is determined from three different aeroshell diameters of 3m, 4m and 5m and with an entry system mass of 2200 kg. With the above range of design parameters, we then determine conservative/bounding estimates of aerothermal environments by using a combination of CFD simulations and stagnation point heating estimates [7]. This engineering approach allows us to first assess the TPS need vs. TPS capability and determine the applicability of existing TPS. Once an applicable suite of TPS is determined, the TPS thickness and mass are computed. We show that the TPS mass fraction can be as low as 5% to as high as 20%, depending on total trip time reduction and other design parameters for a range of TPS. This is a large range for TPS mass fraction. We show PICA and HEEET can indeed enable aerocapture missions, but the missions incur a mass penalty. TPS mass savings, can be further reduced with the use of conformal PICA. Advancing the development of Conformal PICA to make it robust across the entire aerothermal environment (peak heat-flux, pressure and shear) range will result in TPS mass fractions of < 10% for Ice Giant aerocapture missions such as the Neptune-Triton mission. Aerocapture allows for not only shortening the trip time but enables larger mass to be placed in orbit. Furthermore, probes deployed from orbit will benefit in reduced entry environments allowing for a lower risk TPS implementation as compared to mission designs where the probe is released prior to orbit insertion. One of the challenges for the Ice Giant community is to ensure mission designs that maximize science and allow flexibility in the placement of the entry probe. The traditional approach to release the probe ahead of the orbiter may not optimize returned science. In this presentation, we will make the case for mature TPS such as HEEET and PICA. While these materials can enable aerocapture missions, completing the development of conformal PICA and extending Conformal PICA to be more robust, will have significant impact to TPS mass efficiency and significantly enhance science return for future Gas- and Ice-Giant missions.

E Venkatapathy↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

ASPIRE Aerodynamic Models and Flight Performance

The Advanced Supersonic Parachute Inflation Research Experiments (ASPIRE) project waslaunched to develop the capability for testing supersonic parachutes at Mars-relevant conditions.Three initial parachute tests, targeted as a risk-reduction activity for NASA's upcomingMars2020 mission, successfully tested two candidate parachute designs and provided valuabledata on parachute inflation, forces, and aerodynamic behavior. Design of the flight tests dependedon flight mechanics simulations which in turn required aerodynamic models for the payload, andthe parachute. Computational Fluid Dynamics (CFD) was used to generate these models preflightand are compared against the flight data after the tests. For the payload, the reconstructedaerodynamic behavior is close to the pre-flight predictions, but the uncertainties in thereconstructed data are high due to the low dynamic pressures and accelerations during the flightperiod of comparison. For the parachute, the predicted time to inflation agrees well with the preflightmodel; the peak aerodynamic force and the steady state drag on the parachute are withinthe bounds of the pre-flight models, even as the models over-predict the parachute drag atsupersonic Mach numbers. Notably, the flight data does not show the transonic drag decreasepredicted by the pre-flight model. The ASPIRE flight tests provide previously unavailablevaluable data on the performance of a large full-scale parachute behind a slender leading bodyat Mars-relevant Mach number, dynamic pressure and parachute loads. This data is used topropose a new model for the parachute drag behind slender bodies to aid future experiments.

Muppidi, Suman↗