Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “parabolic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Prolonging Microgravity on Parabolic Airplane Flights

Three techniques have been proposed to prolong the intervals of time available for microgravity experiments aboard airplanes flown along parabolic trajectories. Typically, a pilot strives to keep an airplane on such a trajectory during a nominal time interval as long as 25 seconds, and an experimental apparatus is released to float freely in the airplane cabin to take advantage of the microgravitational environment of the trajectory for as long as possible. It is usually not possible to maintain effective microgravity during the entire nominal time interval because random aerodynamic forces and fluctuations in pilot control inputs cause the airplane to deviate slightly from a perfect parabolic trajectory, such that the freely floating apparatus bumps into the ceiling, floor, or a wall of the airplane before the completion of the parabola.

Robinson, David W.↗

Parabolic Flight Evaluation of Bacterial Adhesion on Multiple Antimicrobial Surface Treatments

This report describes the development of a test method and the evaluation of the effectiveness of antimicrobial technologies in reduced gravity based on parabolic flight experiments. Microbial growth is a common occurrence on fully immersed wetted surfaces in spacecraft environmental control and life support systems despite the use of chemical and/or physical \disinfection. Many materials and surface treatments with antimicrobial properties are commercially available but none have been vetted for spaceflight applications. Herein a test method is explained that included ground and reduced gravity parabolic flight experiments with a standard microorganism recovered from spacecraft, Pseudomonas aeruginosa, added at a concentration of 1 x 10(exp 5) cells per milliliter (mL) onto challenge material coupon surfaces. Several experimental materials were observed to slightly reduce microbial attachment in reduced gravity flight experiments, but none were capable of eliminating all challenge bacteria. Lunar gravity had an increased antimicrobial effect in 28 out of 36 test coupons compared to microgravity when provided otherwise identical conditions for growth, suggesting trace .amounts of gravity may be required for maximum antimicrobial performance. Bacterial cells exposed to variable gravity had more than twice as ,much intracellular adenosine triphosphate (ATP) when compared to control cells exposed only to Earth gravity due to a short duration response to environmental stress. An ATP luminescence assay was the method most amenable to development of an in-flight microbial monitoring assay

Birmele, Michele↗

High Energy Laser Beam Propagation in the Atmosphere: The Integral Invariants of the Nonlinear Parabolic Equation and the Method of Moments

The method of moments is used to define and derive expressions for laser beam deflection and beam radius broadening for high-energy propagation through the Earth s atmosphere. These expressions are augmented with the integral invariants of the corresponding nonlinear parabolic equation that describes the electric field of high-energy laser beam to propagation to yield universal equations for the aforementioned quantities; the beam deflection is a linear function of the propagation distance whereas the beam broadening is a quadratic function of distance. The coefficients of these expressions are then derived from a thin screen approximation solution of the nonlinear parabolic equation to give corresponding analytical expressions for a target located outside the Earth s atmospheric layer. These equations, which are graphically presented for a host of propagation scenarios, as well as the thin screen model, are easily amenable to the phase expansions of the wave front for the specification and design of adaptive optics algorithms to correct for the inherent phase aberrations. This work finds application in, for example, the analysis of beamed energy propulsion for space-based vehicles.

Manning, Robert M.↗

Functional Task Tests in Partial Gravity During Parabolic Flight

BACKGROUND Critical mission tasks that are required by crews immediately after landing on a planetary surface are seat egress, jump, and walk. To be able to define an effective and comprehensive countermeasure strategy for preserving crew performance during exploration-class missions, there is a need to understand how these functional tasks are actually performed in partial gravity such as on the Moon or Mars. We propose to study the performance in the execution of these tasks during the partial gravity and hypergravity phases of parabolic flight. These tasks will be completed using the same equipment and procedures as the Standard Measures Sensorimotor protocol, which is performed by astronauts returning from spaceflight and by ground-based subjects after prolonged axial body unloading during bed rest. HYPOTHESIS We hypothesize that partial gravity during parabolic flight will cause acute changes in vestibular, proprioceptive, and sensorimotor functions, and these changes will impact the performance of mission critical tasks such as standing, walking, and jumping. The largest changes in performance are expected at the lowest gravity level (0.25g) because subjects will no longer be able to use the gravitational reference for the perception of vertical. Ultimately, this information could be used to assess performance risks and inform the design of countermeasures for NASA exploration-class human missions. METHODS Twelve subjects will be tested during three flights of 30 parabolas, including 10 parabolas at 0.25g, 10 parabolas at 0.5g and 10 parabolas at 0.75g. Subject also will perform tests in 1g between parabolas and in hypergravity (1.8g) during the pull-out phases. Subjects will perform the same tasks as those tested on astronauts returning from spaceflight: sit-to-stand and obstacle walk, tandem walk, jump down, and recovery from fall. Measurements will include: (a) the time for the subject to complete the test (sit-to-stand and obstacle walk, recovery from fall); (b) the time elapsed between the start of motion and the stabilization of upright posture (recovery from fall, jump down); (c) the mean sway speed during quiet standing (recovery from fall, jump down); (d) changes in heart rate and blood pressure (recovery from fall); (e) the percentage of correct steps and torso acceleration (tandem walk); and (f) the severity of motion sickness symptoms. RELEVANCE Although gravitational dose-response curves have been obtained for some biochemical systems in animals, these dose-responses are unknown for most human physiologic systems. Our study will compare the outcomes of 5 functional task tests in 0.25g, 0.5g, 0.75g, 1g, and 1.8g with those previously obtained in ground-based subjects after prolonged axial body unloading and in astronauts immediately after spaceflight. This comparison will help understanding the true extent of functional task performance deficits in partial gravity. The dose-response relationship between gravity level and task performance decrement also will help determining the gravity threshold for these functional tasks. ACKNOWLEDGEMENT This work is supported by the NASA’s Human Research Program Human Health Countermeasures Element

Gilles Clement↗

Functional Task Tests in Partial Gravity During Parabolic Flight

BACKGROUND Critical mission tasks required by crews immediately after landing on a planetary surface include walking, jumping, and egressing from a seat. Understanding how these functional tasks are performed in partial gravity such as on the moon or Mars is necessary to define effective and comprehensive countermeasure strategies for preserving crew performance during exploration-class missions. We propose to study the performance of these tasks during the partial gravity phases of parabolic flight. These tasks will be performed using the same equipment and procedures as those used with astronauts returning from spaceflight and with ground-based subjects after prolonged axial body unloading during bed rest (sensorimotor standard measures). HYPOTHESIS We hypothesize that partial gravity during parabolic flight will cause acute changes in vestibular, proprioceptive, and sensorimotor functions, and these changes will impact the performance of mission critical tasks such as standing, walking, and jumping. The largest changes in performance are expected at the lowest gravity level (0.25g) because subjects will no longer be able to use the gravitational reference for the perception of upright. Ultimately, this information could be used to assess performance risks and inform the design of countermeasures for NASA exploration-class human missions. METHODS Twelve subjects will be tested during three flights of 30 parabolas, including 10 parabolas at 0.25g, 10 parabolas at 0.5g, and 10 parabolas at 0.75g. Subjects also will perform tests in 1g between parabolas. The tasks will be the same as those tested on astronauts returning from spaceflight: sit-to-stand with obstacle walk, tandem rail balance, jump down, and recovery from fall. Measurements will include: (a) time to test completion (sit-to-stand with obstacle walk, recovery from fall); (b) time elapsed between the start of motion and the stabilization of upright posture (recovery from fall, jump down); (c) mean sway speed during quiet standing (recovery from fall, jump down); (d) changes in heart rate and blood pressure (recovery from fall); (e) balance time and torso accelerations (tandem rail balance); (f) cone of stability (jump down); and (g) severity of motion sickness symptoms. RELEVANCE Although gravitational dose-response curves have been obtained for some biochemical systems in animals, these dose-responses are unknown for most human physiologic systems. Our study will compare the outcomes of four functional task tests in 0.25g, 0.5g, 0.75g, and 1g with those previously obtained in ground-based subjects after prolonged axial body unloading and in astronauts immediately after spaceflight. These comparisons will help us understand the true extent of functional task performance deficits in partial gravity. The dose-response relationship between gravity level and task performance decrement also will help determining the gravity threshold for these functional tasks. ACKNOWLEDGEMENT This work is supported by the NASA’s Human Research Program Human Health Countermeasures Element.

T. R. Macaulay↗

CESO 22-4: Parabolic and Suborbital Glovebox in Support of Space Crop Production

Space crop production research approaches and technologies can be validated for microgravity using parabolic or suborbital flight opportunities, and this will save considerable risk, time, and money for implementing new strategies in spaceflight. While the durations of microgravity in these tests are insufficient to grow crops, there are numerous examples of the value of microgravity testing for subsystems such as plant water and nutrient delivery, where multiphase fluid flow can be elucidated in short durations, and horticultural operations, such as harvesting and produce sanitation where containment and contamination can be assessed. Containment in any operational test is essential, as crop operations involve fluids and biological samples, which are potential hazards. This project consists of designing, developing, and constructing a parabolic/suborbital glovebox for experiment containment. The design involves modifications and upgrades to an existing glovebox developed at the University of Louisville. The University of Louisville glovebox was used by KSC researchers for space crop parabolic flight tests in 2021, and lessons learned from that testing have driven design modifications and improvements in the KSC-generated glovebox. Requirements were identified, parts were ordered, an operational science glovebox was fabricated, and a detailed materials specification list was generated. Analyses that are required for flight, remain to be performed to meet airworthiness requirements, and that work will have to be conducted in the future before use in flight.

Food Production↗

Functional Task Tests in Partial Gravity During Parabolic Flight

BACKGROUND Understanding how critical mission tasks are performed in partial gravity such as on the moon or Mars is necessary to define effective and comprehensive countermeasure strategies for preserving crew performance during exploration missions. We studied the performance of tasks such as standing, walking, and jumping during the partial gravity phases of parabolic flight. We hypothesized that the acute effects of partial gravity on vestibular, proprioceptive, and sensorimotor functions would negatively impact performance. METHODS Twelve subjects were tested over three flights of 30 parabolas each, including 10 parabolas at 0.25g, 10 parabolas at 0.5g, and 10 parabolas at 0.75g. Subjects also performed tests in 1g between parabolas. During the sit-to-stand with obstacle walk task, subjects rose from a seated position and walked as quickly as possible straight ahead towards a cone (4 m distance), walked around the cone making a 180° left turn, returned, and sat in the chair. On the way to and from the cone, subjects stepped over a 30 cm high obstacle. For the recovery from fall task, subjects lay prone for the pull-up phase and initial 10 sec of the parabola. Then they were asked to rise as quickly as possible and maintain a quiet stance for 10 sec. The tandem rail balance task involved standing with both feet on a 4.5 cm wide rail. The time ended when subjects either stepped off the rail or grabbed on to support straps. The jump down task started with the subjects standing on a 30 cm high platform, then the subjects were instructed to step off the platform, land with both feet simultaneously, and settle in a quiet stance. The cone of stability task involved subjects leaning about the ankles as far as they could in the anterior, posterior, and lateral directions without unfolding their arms or taking a step. The center of pressure distance between endpoints was calculated. Data were collected using inertial measurement units (Opal V2, APDM, Portland, OR) worn on the head and trunk, heart rate monitors (RS800CX, Polar, Kempele, Finland), and a force plate (Bertec, Columbus, OH). RESULTS Gravity level had a significant effect on performance, with the greatest changes from 1g tending to be at the 0.25g level (Table 1). Lower gravity levels were associated with increased times to complete the sit-to-stand obstacle walk task and the recovery from fall task, decreased change in heart rate during the recovery from fall task, decreased rail balance times, and increased cone of stability distance in the anterior-posterior direction. Table 1. Functional task performance at different gravity levels during parabolic flight. Measure0.25g0.5g0.75g1gp-valueSit-to-stand with obstacle walk time (sec)9.8 ±1.4*7.2 ±0.76.9 ±0.8*7.4 ±0.9<0.001Recovery from fall time to settle (sec)5.3 ± 0.9*4.6 ± 0.84.2 ± 0.64.3 ± 0.70.002Recovery from fall change in heart rate (bpm)6.0 ± 7.3*11.2 ± 6.5*14.9 ± 4.915.9 ± 6.5<0.001Rail balance with eyes open time (sec)2.7 ±0.8*4.8 ±2.16.6 ±4.78.4 ±6.70.031Rail balance with eyes closed time (sec)1.6 ±0.4*2.1 ±0.42.4 ±0.62.6 ±0.8<0.001Jump down time to settle (sec)2.1 ± 0.41.9 ± 0.42.0 ± 0.31.8 ± 0.30.328Cone of stability –anterior-posterior (cm)20.8 ±2.7*18.8 ±2.218.6 ±1.717.9 ±2.00.039Cone of stability –lateral (cm)26.8 ±6.624.4 ±2.123.0 ±2.123.8 ±2.30.215p-value: one-way repeated measures analysis of variance; *Significant pairwise difference from 1g (p<0.05). DISCUSSION These data suggest that there is a dose-response relationship between gravity level and functional task performance. The largest changes in performance were expected at the lowest gravity level (0.25g) because subjects would no longer be able to use the gravitational reference for the perception of upright. Understanding the extent of performance deficits informs the risks and design of countermeasures for exploration spaceflight missions. ACKNOWLEDGEMENT This work is supported by NASA’s Human Research Program Human Health Countermeasures Element.

T R Macaulay↗

The Parabolic Deformable Mirror Testbed at NASA Goddard Space Flight Center

One of the primary goals of future coronagraph space missions is to spectrally characterize Earth-like exoplanets. Observing efficiency is critical and directly related to how large of a field of view we can correct and the bandwidth of that correction. In addition to the coronagraph itself, the bandwidth and depth of contrast is related to the wavefront control system, which classically uses two deformable mirrors (DMs) in series. The minimum distance between these DMs is determined by the Talbot distance of the beam, meaning it scales as the square of the beam size. NASA Goddard is exploring an alternative design architecture to the two-DM approach in which the reimaging optics for the coronagraph are also deformable and we only retain a high-order pupil DM. With these off-axis parabolic elements being made deformable, the long propagation distance between the two DMs is eliminated. Goddard has procured an off-axis parabolic DM (PDM or OAP DM) from vendor ALPAO, France. A testbed is currently being built to test the PDM and demonstrate its utility for achieving high contrast in a coronagraph. The testbed is also being built with an integrated low-order wavefront sensing capability, allowing for integrated testing of a dynamic environment with multiple estimation and control loops.

Hari Subedi↗

Parabolic Deformable Mirror Project Development and Device Characterization

Existing state-of-the-art wavefront sensing and control setups for the imaging of exoplanets utilize two high-actuator count flat deformable mirrors (DMs) to control both phase and amplitude aberrations. One of the objectives of the Exoplanet Spectroscopy (ExoSpec) project at Goddard Space Flight Center (GSFC) is to improve upon this regime through the development of parabolic deformable mirrors (PDMs), which can address several of the key limitations in existing setups. Specifically, the need for flat DMs to be located in conjugate pupil planes drives unique packaging challenges that can be overcome by allowing the off-axis imaging elements to be controllable as well. In addition, simulations show that the use of deformable powered elements will increase the overall controllable bandwidth, up to 35% over 5-12 lambda/D. To pursue this effort, the ExoSpec group has begun testing a first-generation parabolic DM, which is already informing a second generation design. This paper will provide a comprehensive update on its characterization, including influence function measurements, linearity analysis, closed-loop wavefront control performance, and thermal stability assessment.

spectroscopy↗

CFD Modeling of Bi-Directional PMD inside Cryogenic Propellant Tanks Onboard Parabolic Flights

Future cryogenic propulsion systems will require efficient methods with which to transfer cryogenic propellants from a depot storage tank to a customer receiver tank to minimize cost and maximize reusability. The Reduced Gravity Cryogenic Transfer project is currently developing advanced cryogenic fluid management technology and developing and validating new numerical models for three phases of transfer: line chilldown, tank chilldown, and tank fill. Additionally, multiple liquid nitrogen (LN 2 ) parabolic flight transfer rigs are being designed by universities and NASA to investigate the gravitational sensitivities that exist in these three technologies. In order to maximize the collection of low-g data during flights, it is required to extract as much (LN 2 as possible from the supply tank, despite variable gravity levels. The purpose of this paper is to present computational fluid dynamics (CFD) volume of fluid simulations of (LN 2 behavior in the supply tank onboard parabolic flights to validate the optimal design of a bi-directional propellant management device (PMD) using the commercial software FLOW-3D. A parametric study is conducted on the effects of gravity level, fill level, pore size, open area, thickness, and type of baffle on PMD performance. Based on results, the PMD as designed exceeds the targeted expulsion efficiency.

Jason Hartwig↗

Influence of the concentration ratio on the thermal and economic performance of parabolic trough collectors

The thermal and economic performance of parabolic trough collectors (PTCs) and PTCs with double glass envelope (DGE-PTCs) are analyzed in this work. A model including thermal and optical effects is developed to evaluate the efficiency of vacuum and air-filled DGE-PTCs, while an economic model based on two commercial PTCs (SkyTrough and Ultimate Trough collectors) was developed to assess the economic performance. The efficiency and thermal output per unit cost of the proposed DGE-PTCs are analyzed as a function of the concentration ratio and are respectively compared with the thermal and economic performance of traditional and commercial PTCs. The optimum concentration ratio for maximum thermal performance varies from 11.0 to 23.3 for operation temperatures (T HTF ) between 100 degrees C and 400 degrees C, while the optimum concentration ratio for maximum economic performance ranges between 28.9 and 33.2 for the SkyTrough and between 40.0 and 43.8 for the Ultimate Trough collector designs. Finally, the DGE-PTCs present higher thermal and economic performance at high operating temperatures, which presents a valuable opportunity for implementation in new PTC designs pursuing higher operating temperatures to achieve superior thermal cycle efficiencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Analyses of Supercritical Carbon Dioxide-Based Parabolic Trough Collectors with Double-Glazed Receivers

Supercritical carbon dioxide is becoming a hot research topic as a potential heat transfer fluid in parabolic trough concentrators since it enables operating the solar system at high temperatures for a higher quality of energy. However, the corresponding inflated thermal losses necessitate alternative receiver designs. This work examines four double-glazed receivers, with each annular space being evacuated or non-evacuated, in terms of the absorber tube's diameter (53-80 mm) and the diameter ratios of the two glass shells (1.2-2.0). An analytical model is developed and validated for this purpose, and the four designs are further examined using ground-level solar and meteorological measurements. The results demonstrate higher performance in the case of fully evacuating the receiver and using the smallest possible diameters of the three concentric cylinders, where the energy and exergy efficiencies reach 65.3 and 40.3%, respectively. Yet, evacuating only the inner annular space is sufficient to achieve virtually the same performance level. This energy efficiency decreases to 62% in case of increasing the tube diameter to 80 mm. As the operating temperature increases from 423 to 850 K, the specific thermal losses increase by 3.98-4.34 folds, depending on the receiver design. Double glazing the receivers is favorable only at high operating temperatures of sCO2, where the reduction in thermal losses overcomes the drop in optical efficiency. For an inlet sCO2 temperature of 850 K, thermal losses are reduced by 33.64 and 53.92%, compared to evacuated and non-evacuated single-glazed receivers, respectively. Throughout the year, the fully evacuated and fully non-evacuated double-glazed receivers have energy efficiencies of 54.96 and 52.39%, exergy efficiencies of 33.64 and 32.06%, and thermal losses of 348.8 and 402.5 W/m, respectively.

analytical model↗

Simulating a solar parabolic trough collector plant used for industrial process heat using an optimized operating scheme that utilizes flexible heat integration

This study focuses on the modeling and simulation of a novel design and operation of a solar industrial process heat (SIPH) plant that uses a parabolic trough collector system for generating process heat. The SIPH plant incorporates flexible heat integration (FHI) by having two options for heat sinks as well as a flexible collection temperature for the heat transfer fluid. Leveraging the degrees of freedom created by FHI allows an optimized operating scheme to be created which maximizes the solar heat delivered to the industrial processes. Yearly results for a 27 MW-t plant located in Salt Lake City, UT are simulated for a base case and a case utilizing optimized FHI. For the main process temperature case presented, FHI increases the total solar share by 13.0% and reduces the levelized cost of heat of the SIPH plant by 10.4% relative to the base case. Furthermore, three case study days are presented which highlight how FHI maximizes solar share, specifically during mornings, afternoons, and days with intermittent solar conditions. An environmental analysis is also performed showing that the SIPH plant can reduce harmful emissions by 15.4% for the base case and 17.4% for the FHI case compared to a plant that only utilizes a natural gas furnace for process heat. Overall, the work thoroughly explores an effective operating scheme for a SIPH plant, helping to make it more economical and environmentally beneficial.

14 SOLAR ENERGY↗

Theoretical and numerical studies of inverse source problem for the linear parabolic equation with sparse boundary measurements

We consider the inverse source problem in the parabolic equation, where the unknown source possesses the semi-discrete formulation. Theoretically, we prove that the flux data from any nonempty open subset of the boundary can uniquely determine the semi-discrete source. This means the observed area can be extremely small, and that is the reason we call it sparse boundary data. For the numerical reconstruction, we formulate the problem from the Bayesian sequential prediction perspective and conduct the numerical examples which estimate the space-time-dependent source state by state. To better demonstrate the method’s performance, we solve two common multiscale problems from two models with a long source sequence. The numerical results illustrate that the inversion is accurate and efficient.

97 MATHEMATICS AND COMPUTING↗

On the Convergence of Physics Informed Neural Networks for Linear Second-Order Elliptic and Parabolic Type PDEs

Physics informed neural networks (PINNs) are deep learning based techniques for solving partial differential equations (PDEs) encountered in computational science and engineering. Guided by data and physical laws, PINNs find a neural network that approximates the solution to a system of PDEs. Such a neural network is obtained by minimizing a loss function in which any prior knowledge of PDEs and data are encoded. Despite its remarkable empirical success in one, two or three dimensional problems, there is little theoretical justification for PINNs. As the number of data grows, PINNs generate a sequence of minimizers which correspond to a sequence of neural networks. We want to answer the question: Does the sequence of minimizers converge to the solution to the PDE? We consider two classes of PDEs: linear second-order elliptic and parabolic. By adapting the Schauder approach and the maximum principle, we show that the sequence of minimizers strongly converges to the PDE solution in C 0 . Furthermore, we show that if each minimizer satisfies the initial/boundary conditions, the convergence mode becomes H 1 . Computational examples are provided to illustrate our theoretical findings. To the best of our knowledge, this is the first theoretical work that shows the consistency of PINNs.

97 MATHEMATICS AND COMPUTING↗