Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “oven”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A traverse gravimeter for the lunar surface.

A semiautomatic, self-leveling lunar gravimeter has been designed for the purpose of measuring gravity at predetermined stops along the route of a Lunar Rover Vehicle to obtain a gravity profile. The Traverse Gravimeter is completely self-contained and is powered by an internal battery. The gravity sensor is a vibrating string accelerometer (VSA) which is enclosed in a precision oven. Gravity data are obtained by initiating a measurement. After the gravimeter has leveled, the VSA difference frequency is counted down and a gate is generated to enable a crystal-controlled clock to a BCD counter. The BCD counter stores the data which are a measurement of gravity. These data, displayed upon command by the astronaut, are transmitted by voice back to earth.

Mamon, G.↗

The effects of various cure cycles upon the viability of Bacillus subtillis var. niger spores within solid propellant.

Saturethane solid propellant was used in all tests. The spore inoculum was evenly distributed in the propellant. Samples weighing approximately 5 g were aseptically removed, placed into curing ovens, and exposed to cure temperatures. Initial tests were conducted at 82 and 93 C. Analysis of the obtained data indicated that the survivor curves were not linear. Exposure of the inoculated propellant samples to 93 C reduced the initial population to less than 0.01% in about 20 hours. At 82 C, approximately 168 hours were required for a similar reduction. Tests involving curing temperatures of 105 and 115 C were also conducted. It is pointed out that changes in the mechanism of spore inactivation due to chemical and physical changes in the propellant could account for the nonlinear survivor curves obtained.

Brewer, W. A.↗

Manufacture of large, lightweight parabolic antennas

Antenna was produced in segments. Parabole sections were built up as aluminum foil sandwich with core bonded by film adhesive; whole structure was oven-cured after assembly. Structure was assembled with special tool for splice-bonding segments into complete dish, and inflatable bladder to apply pressure at joints during cure.

Hooper, S. W.↗

Design and development of pressure and repressurization purge system for reusable space shuttle multilayer insulation system

The experimental determination of purge bag materials properties, development of purge bag manufacturing techniques, experimental evaluation of a subscale purge bag under simulated operating conditions and the experimental evaluation of the purge pin concept for MLI purging are discussed. The basic purge bag material, epoxy fiberglass bounded by skins of FEP Teflon, showed no significant permeability to helium flow under normal operating conditions. Purge bag small scale manufacturing tests were conducted to develop tooling and fabrication techniques for use in full scale bag manufacture. A purge bag material layup technique was developed whereby the two plys of epoxy fiberglass enclosed between skins of FEP Teflon are vacuum bag cured in an oven in a single operation. The material is cured on a tool with the shape of a purge bag half. Plastic tooling was selected for use in bag fabrication. A model purge bag 0.6 m in diameter was fabricated and subjected to a series of structural and environmental tests simulating various flight type environments. Pressure cycling tests at high (450 K) and low (200 K) temperature as well as acoustic loading tests were performed. The purge bag concept proved to be structurally sound and was used for the full scale bag detailed design model.

Source record↗

Traverse gravimeter experiment

A semiautomatic self-leveling lunar gravimeter has been designed for the Apollo 17 mission. This traverse gravimeter, which is completely self-contained and powered by an internal battery, was used to measure gravity at predetermined stops along the route of the Lunar Rover Vehicle. The gravity sensor is a vibrating string accelerometer (VSA) enclosed in a temperature-controlled oven and gimballed leveling assembly. This instrument is capable of resolving gravity differences as small as 0.035 milligal (1 mgal = 0.001 cm/s) on the moon and yet also is able to measure the earth's gravity field of 980,000 milligals. Twenty-two measurements were taken on the moon during the Apollo 17 mission, during which the VSA temperature never varied more than 0.005 C. The flight results indicate an instrument accuracy of better than 2 mgal.

Buck, S. W.↗

Services provided in support of the planetary quarantine requirements of the National Aeronautics and Space Administration

The project to evaluate thermal sterilization for unmanned landers is reported. A temperature controlled oven with a nitrogen gas supply containing a known concentration of water is discussed. The studies show that bacillus lentus, bacillus brevis, bacillus coagulans, atypical bacillus spp., and actinomycete are isolated heat survivors. The thermal resistance is given for naturally occurring airborne bacterial spores collected on exposed teflon ribbons.

Favero, M. S.↗

Cleaning and activation of beryllium-copper electron multiplier dynodes.

Description of a cleaning and activation procedure followed in preparing beryllium-copper dynodes for electron multipliers used in sounding-rocket experiments to detect auroral electrons. The initial degreasing step involved a 5-min bath in trichloroethylene in an ultrasonic cleaner. This was followed by an ultrasonic rinse in methanol and by a two-step acid pickling treatment to remove the oxides. Additional rinsing in water and methanol was followed by activation in a stainless-steel RF induction oven.

Pongratz, M. B.↗

Thermally-stable, syntactic pyrrone foams

Foam formulations may be readily emplaced in honeycomb structures after heating to soft, doughlike consistency and forcing heated mixture into honeycomb cells. Final cure can be accomplished by simple oven cure, with no need for containment or restriction of foam formulation during cure.

Kimmel, B. G.↗

Development of autoclavable addition type polyimides

Two highly promising approaches to yield autoclavable addition-type polyimides were identified and evaluated in the program. Conditions were established for autoclave preparation of Hercules HMS graphite fiber reinforced composites in the temperature range of 473 K to 505 K under an applied pressure of 0.7 MN/m2 (100 psi) for time durations up to four hours. Upon oven postcure in air at 589 K, composite samples demonstrated high mechanical property retention at 561 K after isothermal aging in air for 1000 hours. Promise was shown for shorter term mechanical property retention at 589 K upon exposure in air at this temperature.

Jones, R. J.↗

Filament winding S-glass/polyimide resin composite processing studies

The work performed in selecting a TRW A-type polyimide resin that would be suitable for fabrication of filament wound reinforced plastic structures is described. Several different formulations were evaluated after which the P105AC formulation was selected as the most promising. Procedures then were developed for preparing P105AC/S-glass roving prepreg and for fabricating filament wound structural composites. Composites were fabricated and then tested in order to obtain tensile and shear strength information. Small, closed-end cylindrical pressure vessels then were fabricated using a stainless steel liner and end fittings with a P105AC/S-glass polar wound overwrap. These pressure vessels were cured in an air circulating oven without augmented pressure. It is concluded that the P105AC resin system is suitable for filament winding; that low void content, high strength composites are obtained by the filament winding process; and that augmented pressure is not required to effect the fabrication of filament wound P105AC composites.

Vaughan, R. W.↗

TRW A-type polyimide resin for filament winding

Studies were conducted to select a TRW A-type polyimide resin that would be suitable for fabrication of filament wound reinforced plastics structures. Several different formulations were evaluated after which the P105AC formulation was selected as the most promising. Procedures were developed for preparing P105AC/S-glass roving prepreg and for fabricating filament wound structural composites. Composites were fabricated and then tested in order to obtain tensile and shear strength information. Small, closed-end cylindrical pressure vessels then were fabricated using a stainless steel liner and end-fittings with a P105AC/S-glass polar-wound overwrap. These pressure vessels were cured in an air circulating oven without augmented pressure. It was concluded upon completion of this study that the P105AC resin system is suitable for filament winding; that low void content, high strength composites are obtained by the filament winding process; and that augmented pressure is not required to effect the fabrication of filament wound P105AC composites.

Vaughan, R. W.↗

Results of the long range position-determining system tests

The long range position-determining system (LRPDS) has been developed by the Corps of Engineers to provide the Field Army with a rapid and accurate positioning capability. The LRPDS consists of an airborne reference position set (RPS), up to 30 ground based positioning sets (PS), and a position computing central (PCC). The PCC calculates the position of each PS based on the range change information provided by each Set. The positions can be relayed back to the PS again via RPS. Each PS unit contains a double oven precise crystal oscillator. The RPS contains a Hewlett-Packard cesium beam standard. Frequency drifts and off-sets of the crystal oscillators are taken in account in the data reduction process. A field test program was initiated in November 1972. A total of 54 flights were made which included six flights for equipment testing and 48 flights utilizing the field test data reduction program. The four general types of PS layouts used were: short range; medium range; long range; tactical configuration. The overall RMS radial error of the unknown positions varied from about 2.3 meters for the short range to about 15 meters for the long range. The corresponding elevation RMS errors vary from about 12 meters to 37 meters.

Rhode, F. W.↗

An aneroid pressure sensor for constant-level balloons

The pressure sensor for the Tropical Wind Energy conversion and Reference Level Experiment (TWERLE) is described. Key design features of the sensor are: capacitive coupling, reference at midrange, up-down counting, passive oven, storage at flight pressure and prelaunch calibration. Sensor specifications are given which are based on the production results of 440 units. Drift, as estimated from simulated life tests, is 1 mb per 6 months. The overall weight of the sensor, including thermal package, is 180 g.

Levanon, N.↗

Low-pressure low-temperature molding process

Use of expanding rubber mandrel allows for bonding of graphite/epoxy laminated parts in oven instead of expensive autoclave. Heavy-duty two-piece aluminum mold limits deflection. Manipulation of resin contact by precise control of mandrel-generated pressure eliminates complex bleeder system.

Bowman, E. L.↗

Development of improved amorphous materials for laser systems

Crystallization calculations were performed in order to determine the possibility of forming a particular type of laser glass with the avoidance of devitrification in an outer space laboratory. It was demonstrated that under the homogenuous nucleating conditions obtainable in a zero gravity laboratory this laser glass may be easily quenched to a virtually crystal-free product. Experimental evidence is provided that use of this material as a host in a neodymium glass laser would result in more than a 10 percent increase in efficiency when compared to laser glass rods of a similar composition currently commercially available. Differential thermal analysis, thermal gradient oven, X-ray diffraction, and liquidus determination experiments were carried out to determine the basics of the crystallization behavior of the glass, and small-angle X-ray scattering and splat-cooling experiments were performed in order to provide additional evidence for the feasibility of producing this laser glass material, crystal free, in an outer space environment.

Neilson, G. F.↗

Space shuttle galley water system test program

A water system for food rehydration was tested to determine the requirements for a space shuttle gallery flight system. A new food package concept had been previously developed in which water was introduced into the sealed package by means of a needle and septum. The needle configuration was developed and the flow characteristics measured. The interface between the food package and the water system, oven, and food tray was determined.

Source record↗

On-line mass spectrometric monitoring of the polymerization of a phenolic-resin-based material

Polymerization of phenolic-resin-based materials requires elevated temperatures. The low thermal conductivity of these materials has led to the use of dielectric heating techniques in lieu of standard convection oven heating to obtain a satisfactory cure. The curing rate and therefore the quality of the cured material depends on the heating rate and maximum temperature attained, parameters which are extremely difficult to measure in dielectric heating units. The dielectric curing of these materials was monitored by using a mass spectrometer to measure the partial pressure of phenol in the gas evolved during polymerization. The resulting plots of phenol partial pressure as a function of time have a characteristic shape, and these may be used to indicate the attainment of complete curing. The validity of the mass spectrometric technique was confirmed by chemical analysis of the polymerized samples.

Aikens, D. A.↗

Chemiluminescence Study on Thermal Degradation of Aircraft Tire Elastomers

Since the autoxidative process accounts in part for the degradation of rubber, including aircraft tires, it was felt that a study of the chemiluminescence from unsaturated elastomers could contribute significantly to an understanding of the degradation mechanism. The study revealed similarities in chemiluminescence behavior between four elastomers which were investigated, and it shows that similar oxidation mechanisms occur. Oxidative chemiluminescence was observed from purified samples of cis-1,4-polybutadiene, cis-1,4-polyisoprene, trans-polypentenamer, and 1,2-polybutadiene in an oxygen atmosphere at 25-150 C. The elastomer samples were placed in a 600 watt oven which is equipped with gas inlets for introducing any desired atmosphere. Chemiluminescence emission from the samples was focused with a two inch quartz lens onto the detector of a 12" photomultiplier which is connected to a photon counter. A strip-chart recorder, connected to the counter, permitted automatic data collection. Diagrams of the apparatus are included. The chemical reactions which occurred from the thermal decomposition of the polymer samples are described, and results (and tabulated data) are discussed.

Mendenhall, G. D.↗