Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “outdoor lighting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Toward an IMU-Based Space Suit Motion Capture System

Spacesuits are complex engineering systems that sustain human health and enable performance outside Earth-like environments. These systems must support human mobility and physical workload demands while minimizing injury risk during extravehicular activity (EVA). Future EVA operations on the Lunar surface are expected to be more frequent and require higher physical workloads than previously during the ISS, Shuttle, and Apollo programs. To characterize the workloads and ergonomics needs a suit must support, the kinematics of the space suit must be measured during operationally-relevant tasks in ground analog environments. Kinematics capture of the suit is challenging for traditional optical motion capture (OMC) approaches due to marker occlusion, harsh lighting or environmental conditions, and tests with suit surrogates in outdoor field environments. To this end, engineers at NASA are developing the Augmented Suit Inverse Kinematics (ASIK) system, a complete motion capture method and inverse kinematics solver which relies solely on a network of wireless inertial measurement units (IMUs) attached to the major kinematic segments of the spacesuit. The ASIK modeling language allows for the simple inclusion of probabilistic priors such as suit size and shape or IMU poses. The ASIK system was tested in a 7-subject pilot study. Each subject donned NASA’s new prototype exploration spacesuit in the Active Response Gravity Offload System (ARGOS) facility at Johnson Space Center in Houston, TX. The suits were outfitted with 12 IMUs to estimate lower body and trunk kinematics. The suits were also outfitted with a set of reflective OMC markers, and traditional OMC data was collected and processed. Characterization of the ASIK-derived suit joint angles’ accuracy against an optical motion capture datum will be presented. Discussion of these results, as well as discussion of system calibration and nuances of mathematical observability, will be included.

IMU↗

Polymers in solar energy utilization

A laser photoacoustic technique (LPAT) has been verified for performing accelerated life testing of outdoor photooxidation of polymeric materials used in solar energy applications. Samples of the material under test are placed in a chamber with a sensitive microphone, then exposed to chopped laser radiation. The sample absorbs the light and converts it to heat by a nonradiative deexcitation process, thereby reducing pressure fluctuations within the cell. The acoustic signal detected by the microphone is directly proportional to the amount of light absorbed by the specimen. Tests were performed with samples of ethylene/methylacrylate copolymer (EMA) reprecipitated from hot cyclohexane, compressed, and molded into thin (25-50 microns) films. The films were exposed outdoors and sampled by LPAT weekly. The linearity of the light absorbed with respect to the acoustic signal was verified.Correlations were established between the photoacoustic behavior of the materials aged outdoors and the same kinds of samples cooled and heated in a controlled environment reactor. The reactor tests were validated for predicting outdoor exosures up to 55 days.

Liang, R. H.↗

Dual-Zone Solar Control Indoor Shade: Demonstration at the Ronald V. Dellums Federal Building and U.S. Courthouse, 1301 Clay Street, Oakland, California and the Lawrence Berkeley National Laboratory Advanced Windows Testbed, Berkeley, California

Standard window shades are used to control sunlight, glare, window heat gains, and daylight. The challenge with conventional shades is that once the shades are lowered to reduce discomfort, daylight is reduced, which, in turn, increases the need for electric lighting. View is also obstructed, reducing the occupants’ connection to the outdoors. The strategy of subdividing the window wall and admitting daylight from above and controlling sunlight and view through the lower aperture can yield significant energy and peak demand savings over conventional shading systems, and improve the daylight quality of the indoor environment. This study evaluated a dual zone solar control (DZSC) shade with an upper, automated, horizontal, venetian blind with concave-up, matte white slats and a lower, manually operated, roller shade made of a transparent, reflective film. The automatic controls were designed to adjust the upper slat angle to maximize daylight to the room interior. The lower shade, when lowered, provided an unobstructed view to the outdoors. For the qualitative analysis, the DZSC shades were installed on windows in the southeast half of one floor in the Ronald V. Dellums Federal Building and U.S. Courthouse or hereafter referred to as the Oakland Federal Building (OFB) in Oakland, California. The position of the DZSC shades were observed and recorded periodically. Surveys were issued to occupants in the private offices and open plan workstations affected by the shades. For the quantitative analysis, the DZSC shades were installed in the south-facing windows of thermally isolated, fully instrumented, test chambers in the Advanced Windows Testbed at the Lawrence Berkeley National Laboratory (LBNL) in Berkeley, California. Measurements of window heat loads, daylight illuminance and environmental conditions related to visual and thermal comfort were collected over a six-month, solstice-to-solstice period. The performance of the DZSC shade was compared to fabric roller shades and venetian blinds since these are the two most common types of shades used in both commercial and Federal buildings. Several DZSC design permutations were evaluated: 1) manual or automated control of the upper louver system (“man” or “auto”) and 2) tinted or silvered reflective film for the lower shade (“Gray-Gray (GG)” or “Gray-Silver (GS)”1). The automated, reflective shade (auto-GS) reduced dimmable fluorescent lighting energy use by 51% and window cooling load by 13-15% compared to a conventional fabric roller shade with dual-pane, spectrally selective, low-e windows during the summer period (winter period was not measured). Qualitative analysis revealed that the auto-GS shade was preferred by 80% of the survey respondents compared to the existing vertical fabric blinds with single-pane, tinted windows in the occupied building. Survey results indicated that visual discomfort was reduced and thermal discomfort was also reduced during warm or hot weather. Occupants expressed greater satisfaction with the unobstructed view. Installation and commissioning of the DZSC shades was fairly straightforward with some minor problems due to inadequate installation instructions and improper wiring. A few occupants expressed dissatisfaction with the automatic controls for the upper louvers due to visual discomfort, erroneous control, and motor noise.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Revealing Urban Morphology and Outdoor Comfort through Genetic Algorithm-Driven Urban Block Design in Dry and Hot Regions of China

In areas with a dry and hot climate, factors such as strong solar radiation, high temperature, low humidity, dazzling light, and dust storms can tremendously reduce people’s thermal comfort. Therefore, researchers are paying more attention to outdoor thermal comfort in urban environments as part of urban design. This study proposed an automatic workflow to optimize urban spatial forms with the aim of improvement of outdoor thermal comfort conditions, characterized by the universal thermal climate index (UTCI). A city with a dry and hot climate—Kashgar, China—is further selected as an actual case study of an urban block and Rhino & Grasshopper is the platform used to conduct simulation and optimization process with the genetic algorithm. Results showed that in summer, the proposed method can reduce the averaged UTCI from 31.17 to 27.43 °C, a decrease of about 3.74 °C, and reduce mean radiation temperature (MRT) from 43.94 to 41.29 °C, a decrease of about 2.65 °C.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solventless Dual‐Cure Liquid Resins Via Circular Use of Phthalic Anhydride for Recyclable Composite Applications

Abstract Fiber‐reinforced composites (FRCs) possess a remarkable strength‐to‐weight ratio, making them ideal light‐weighing alternative materials of metals used in automotive, aerospace, and outdoor equipment applications, but their recycling is challenging. Chemically recyclable thermoset polymers can enable fiber recovery and reuse; however, challenges remain in the separation and purification of depolymerized small molecules for efficient polymer recycling. To this end, a series of liquid resins for chemically recyclable polymer networks is designed based on phthalic anhydride, a widely produced and inexpensive chemical. The straightforward sublimation of phthalic anhydride is leveraged to enable a simple and efficient separation process for polymer recycling. To liquefy phthalic anhydride, five mono‐acryloyl‐phthalates are synthesized to obtain stable liquid resins together with phthalic diglycidyl ester. These liquid resins undergo dual‐cure reactions that comprise photopolymerization of acrylate and, subsequently, heat‐mediated epoxy‐acid polymerization reactions. These liquid resins exhibit moderate viscosities (2600–6400 cP @ 22 °C), fast curing, and robust thermomechanical properties (T g s from 71 to 116 °C). It is demonstrated that hydrolysis of the dual‐cured polymers completes within 2 h at 80 °C, and direct sublimation produces phthalic anhydride with 82% yield. This resin system is expected to provide a cost‐competitive, highly efficient platform for recyclable FRCs.

Polymer Science↗

Enhanced Photovoltaic Soiling in an Urban Environment

Natural soiling, or the deposition of ambient particulate matter (PM) onto the surface of solar glass, causes losses in PV production around the world. Much work in the PV community has focused on soiling in dusty desert environments. However, PV systems in urban environments are exposed to different contaminants and thus soil differently. We present an analysis of PV soiling in such an urban environment considering the impacts of meteorological parameters. We present 1 year of results from a soiling station in an urban location in Colorado. Bare glass samples were exposed outdoors for 11 days alongside the station; results from microscopy and light transmittance measurements show how moisture and dew affect the morphology and optics of contamination on glass. The coupon results suggest that natural (rain) cleanings may not be sufficient to clean solar panels in urban environments. Ion chromatography of soiling on the reference cell surfaces suggest that dry brush cleanings may not sufficiently clean chemicals deposited on solar panel surfaces in urban environments.

14 SOLAR ENERGY↗

Solar energy meter

An instrument was developed to continually integrate the energy available in incident light on a specifically oriented surface. The unit was designed for outdoor use in remote locations and is capable of operation over a temperature range of -20 to +60 C with good accuracy. The unit is weather resistant, requires low power, has a high input impedance, is inexpensive, and has a visual readout and an analog output for recording.

Masters, R. M.↗

Sequential Stress Identifies Processing Defects in Bifacial Photovoltaic Modules That Limit Durability

Here, we use sequential stress to investigate hurdles to bifacial photovoltaic (PV) module durability from lamination defects. We test mini-modules with glass/glass (G/G) and glass/transparent-backsheet (G/TB) constructions using either ethylene vinyl acetate or polyolefin elastomer (POE) based encapsulants under a modified IEC 63209-2 sequential stress. This sequence includes multiple iterations of damp heat (DH200), full spectrum light exposure (A3), thermal cycling (TC50), and humidity/freeze (HF10). We compare indoor stress with outdoor exposure. Results show similar relative trends in degradation after a year outdoors compared to our first stress cycle. Subsequent stress cycles impart more severe damage than outdoor exposure for the short outdoor duration used here. Edge-pinch lamination defects in G/G mini-modules limit durability causing delamination and cell cracks. Conversely, we observe greater degradation in G/TB mini-modules compared to G/G in the later stages of the stress sequence when the backsheets are directly exposed to UV-containing light. Our results highlight: 1) the utility of sequential stress testing to uncover degradation modes in bifacial PV, 2) implications of using mini-modules for testing PV quality, and 3) the importance of lamination defects that must be avoided to ensure durability as the industry adopts G/G or G/TB packaging.

14 SOLAR ENERGY↗

Adoption of Light-Emitting Diodes in Common Lighting Applications

Report estimating LED energy savings between 2012 and 2014 in 10 applications where LEDs competed with traditional lighting sources such as incandescent, halogen, high-pressure sodium, and fluorescent. The analysis includes indoor lamp, indoor luminaire, and outdoor luminaire applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Energy and Operational Impacts of Using 0-10V Control for LED Streetlights

Lighting systems have historically utilized either a proprietary control method, or one of a handful of standardized methods (e.g., 0-10V, DALI, DMX512) aimed at facilitating vendor interoperability. The utility and market success of the standardized methods has been limited for a variety of reasons. Although 0-10V is presently the most commonly available control interface for indoor and outdoor products in North America – even after the emergence of LED products and “connected lighting systems” with more modern network interfaces and luminaire-level sensors and intelligence – the use of 0-10V methods has significant tradeoffs. For instance, it is difficult to predict relative luminaire light output and input power at any particular control voltage, and performance across luminaires is inconsistent. This study characterizes 23 LED streetlights that claimed dimmability via a 0-10V interface, quantifies the performance variation found in market-available LED drivers, and explores the potential impact of the most recent 0-10V voluntary standard (ANSI C137.1-2022). Notably, the tested products were all manufactured prior to the release of this standard, and thus do not make compliance claims. Variation in response to 0-10V control voltages was expected to be more significant across different make/model luminaires than different units of the same make/model; the test population was structured based on this expectation. The 23 tested luminaires comprised 21 unique make/model streetlights from 14 different manufacturers. Three samples of one make/model streetlight were included in the test population to facilitate a limited exploration of unit-to-unit variation. The 21 unique make/model luminaires contained 20 unique make/model LED drivers from eight different driver manufacturers. Luminaire input power and current were measured at 11 control voltages (0.5 V and 1–10 V in 1 V increments).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exposure of Polymeric Glazing Materials Using NREL's Ultra-Accelerated Weathering System (UAWS)

NREL's Ultra-Accelerated Weathering System (UAWS) selectively reflects and concentrates natural sunlight ultraviolet irradiance below 475 nm onto exposed samples to provide accelerated weathering of materials while keeping samples within realistic temperature limits. This paper will explain the design and implementation of the UAWS which allow it to simulate the effect of years of weathering in weeks of exposure. Exposure chamber design and instrumentation will be discussed for both a prototype UAWS used to test glazing samples as well as a commercial version of UAWS. Candidate polymeric glazing materials have been subjected to accelerated exposure testing at a light intensity level of up to 50 UV suns for an equivalent outdoor exposure in Miami, FL exceeding 15 years. Samples include an impact modified acrylic, fiberglass, and polycarbonate having several thin UV-screening coatings. Concurrent exposure is carried out for identical sample sets at two different temperatures to allow thermal effects to be quantified along with resistance to UV.

14 SOLAR ENERGY↗

What to measure and report in studies of discomfort from glare for pedestrian applications

We report in outdoor environments after dark, pedestrians may experience discomfort from glare caused by lighting. Several models to predict discomfort from glare have been proposed or extended for pedestrian applications; these models use different luminous and geometrical quantities to predict discomfort. Consistent measurements and reporting in studies of discomfort from glare are important for identifying best performing models; however, previous studies proposing a new model tended to only report the performance of the new model and its quantities. This practice makes it difficult to evaluate how a new model performs compared to other existing models. To promote more consistent and complete reporting, this research note proposes measuring and reporting all relevant quantities that are used in existing models. This can make it easier for researchers to use a study dataset to compare the performance of several models or to combine datasets from several studies to address between-study variance.

42 ENGINEERING↗

Dual-Image Color Normalization to Enable High-Performance Concentrating Solar Optical Metrology

Concentrating Solar Power (CSP) requires precision mirrors, and these in turn require metrology systems to measure their optical slope. In this project we studied a color-based approach to the correspondence problem, which is the association of points on an optical target with their corresponding points seen in a reflection. This is a core problem in deflectometry-based metrology, and a color solution would enable important new capabilities. We modeled color as a vector in the [R,G,B] space measured by a digital camera, and explored a dual-image approach to compensate for inevitable changes in illumination color. Through a series of experiments including color target design and dual-image setups both indoors and outdoors, we collected reference/measurement image pairs for a variety of configurations and light conditions. We then analyzed the resulting image pairs by selecting example [R,G,B] pixels in the reference image, and seeking matching [R,G,B] pixels in the measurement image. Modulating a tolerance threshold enabled us to assess both match reliability and match ambiguity, and for some configurations, orthorectification enabled us to assess match accuracy. Using direct-direct imaging, we demonstrated color correspondence achieving average match accuracy values of 0.004 h, where h is the height of the color pattern. We found that wide-area two-dimensional and linear one-dimensional color targets outperformed hybrid linear/lateral gradient targets in the cases studied. Introducing a mirror degraded performance under our current techniques, and we did not have time to evaluate whether matches could be reliably achieved despite varying light conditions. Nonetheless, our results thus far are promising.

14 SOLAR ENERGY↗

Adoption of Light-Emitting Diodes in Common Lighting Applications

Report estimating LED energy savings in nine applications where LEDs compete with traditional lighting sources such as incandescent, halogen, high-pressure sodium, and certain types of fluorescent. The analysis includes indoor lamp, indoor luminaire, and outdoor luminaire applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing Outdoor to Indoor Performance for Bifacial Modules Affected by Polarization-Type Potential-Induced Degradation

Bifacial photovoltaic (PV) modules have the advantage of using light reflected off of the ground to contribute to power production. Predicting the energy gain is challenging and requires complex models to do so accurately. Often, module degradation over time is neglected in models for the sake of simplicity or is underestimated. Comparing outdoor and indoor current–voltage (I–V) performance for bifacial modules is more challenging than for monofacial modules, as there are additional variables to consider such as rear albedo non-uniformity, cell mismatch, and their effects on temperature. This challenge is compounded when heterogeneous degradation modes occur, such as polarization-type potential-induced degradation (PID-p). To examine the effects of PID-p on I–V predictions using an empirical data-driven approach, 16 bifacial PERC modules are installed outdoors on racks with different albedo conditions. A subset is exposed to high-voltage biases of −1500 V or +1500 V. Outdoor data are traced at irradiance ranges of 150–250 W/m 2 , 500–600 W/m 2 , and 900–1000 W/m 2 . These curves are corrected using control module temperature, wire resistivity, and module resistance measured indoors. We examine several methods to transform indoor I–V curves to accurately, and more simply than existing methods, approximate outdoor performance for bifacial modules without and with varying levels of PID-p degradation. This way, bifacial performance modeling can be more accessible and informed by fielded, degraded modules. Distributions of percent errors between indoor and outdoor performance parameters and Mean Absolute Percent Errors (MAPEs) are used to assess method quality. Results including low-irradiance data (150–250 W/m 2 ) are discussed but are filtered for quantifying method quality as these data introduce substantial errors. The method with the most optimal tradeoff between low MAPE and analysis simplicity involves measuring the front side of a module indoors at an irradiance equal to plane-of-array irradiance plus the product of module bifaciality and albedo irradiance. This method gives MAPE values of 1–6.5% for non-degraded and 1.6–5.9% for PID-p degraded module performance.

14 SOLAR ENERGY↗

Electrical Bias as an Alternate Method for Reproducible Measurement of Copper Indium Gallium Diselenide (CIGS) Photovoltaic Modules: Preprint

Light-to-dark metastable changes in thin-film photovoltaic (PV) modules can introduce uncertainty when measuring module performance on indoor flash testing equipment. This study describes a method to stabilize module performance through forward-bias current injection rather than light exposure. Measurements of five pairs of thin-film copper indium gallium diselenide (CIGS) PV modules indicate that forward-bias exposure maintained the PV modules at a stable condition (within 1%) while the unbiased modules degraded in performance by up to 12%. It was additionally found that modules exposed to forward bias exhibited stable performance within about 3% of their long-term outdoor exposed performance. This carrier-injection method provides a way to reduce uncertainty arising from fast transients in thin-film module performance between the time a module is removed from light exposure and when it is measured indoors, effectively simulating continuous light exposure by injecting minority carriers that behave much as photocarriers do. This investigation also provides insight into the initial light-induced transients of thin-film modules upon outdoor deployment.

14 SOLAR ENERGY↗

Long-term impact of light- and elevated temperature-induced degradation on photovoltaic arrays

Low levelized cost of electricity (LCOE) has been identified as critical for widespread adoption of photovoltaics (PV) without subsidies. Maintaining decades-long high-energy production is often an under-recognized opportunity in meeting cost goals because component lifetimes are not fully quantified at the time of manufacture. Whereas certain standardized tests minimize risk of early failure, there is little guidance to quantitatively predict degradation (or lack thereof) over decades, based on accelerated tests. In this article, we move toward bridging the understanding between indoor accelerated tests and outdoor performance data, with the goal of predicting energy yield with enough accuracy to inform financial decisions. Light- and elevated temperature-induced degradation (LETID) in p-type Si modules is analyzed in terms of impact on long-term module performance and thus LCOE. A method to predict the progression of LETID, using fixed kinetic constants and a numerical solution to the basic reaction rate equations, is detailed. Predictions are compared against both published data and that new to this study. These data include both indoor accelerated tests and fielded modules. We use the results in financial models to derive LCOE of modules in different climates with varying amounts of LETID, including uncertainty. Cost models based on the predictions indicate that LETID has a significant and climate-dependent impact on LCOE. Finally, we show that - even given the uncertainties identified in the study - these financial calculations can provide useful guidance to quantify risk based on accelerated test results. The analysis serves as an example of developing a predictive approach to PV reliability using physics of failure.

14 SOLAR ENERGY↗

Climate-simulated raceway pond culturing: quantifying the maximum achievable annual biomass productivity of Chlorella sorokiniana in the contiguous USA

Chlorella sorokiniana (DOE 1412) emerged as one of the most promising microalgae strains from the NAABB consortium project, with a remarkable doubling time under optimal conditions of 2.57 hr-1. However, its maximum achievable annual biomass productivity in outdoor ponds in the contiguous United States remained unknown. In order to address this knowledge gap, this alga was cultured in indoor LED-lighted and temperature-controlled raceways in nutrient replete freshwater (BG-11) medium at pH 7 under conditions simulating the daily sunlight intensity and water temperature fluctuations during three seasons in Southern Florida, an optimal outdoor pond culture location for this organism identified by biomass growth modeling. Prior strain characterization indicated that the average maximum specific growth rate (µmax) at 36 ºC declined continuously with pH, with µmax corresponding to 5.92, 5.83, 4.89, and 4.21 day-1 at pH 6, 7, 8, and 9, respectively. In addition, the maximum specific growth rate declined nearly linearly with increasing salinity until no growth was observed above 35 g/L NaCl. In the climate-simulated culturing studies, the volumetric ash-free dry weight-based biomass productivities during the linear growth phase were 57, 69, and 97 mg/L-day for 30-year average light and temperature simulations for January (winter), March (spring), and July (summer), respectively, which corresponds to average areal productivities of 11.6, 14.1, and 19.9 g/m2-day at a constant pond depth of 20.5 cm. The photosynthetic efficiencies (PAR) in the three climate-simulated pond culturing experiments ranged from 4.1 to 5.1%. The annual biomass productivity was estimated as ca. 15 g/m2-day, nearly double the U.S. Department of Energy (DOE) 2015 State of Technology annual cultivation productivity of 8.5 g/m2-day, but this is still significantly below the projected 2022 target of ca. 25 g/m2-day (U.S. DOE, 2016) for economic microalgal biofuel production, indicating the need for additional research in strain biology and system engineering.

annual biomass productivity↗