Clear Sky Toolkit: Decision Support User Guide

The Clear Sky Decision Support Template is a Microsoft Excel-based resource that enables users to screen and prioritize critical facilities for the addition of solar + storage. The Decision Support Template consolidates and streamlines the most relevant resources from the emergency management discipline, the electric utility sector, and national energy research institutions to assist in further site analysis and decision-making. The Decision Support Template is intended for use by local government and private sector decision-makers who aim to mitigate the effects of power outages on critical infrastructure, understand the potential for deploying photovoltaic (PV) and storage solutions on critical facilities, and align emergency management planning processes and utility needs with community resilience objectives. The Decision Support Template is divided into five modules that provide a structured, step-by-step approach users can follow and apply to unique circumstances. This process guides a more thorough and accurate assessment of a site's potential to accommodate a solar + storage system, provide grid benefits to utilities, and support community resilience and disaster mitigation for the broader region. After identifying potentially viable and preferred sites for solar + storage using the Decision Support Template, users should conduct a more detailed evaluation and consultation with a solar professional.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data Analyst - A Device for Continuous Repeating Real-Time Assay of HPGe, CZT, or Scintillation Gamma Spectra - 18574

There are many situations where a continuous repeating series of quantitative gamma spectral assays is desirable. These include measurements of fluid going through a pipe, of items on a conveyor passing under a detector, a detector aimed at the ground on a moving platform, or a detector in free air as a plume of radioactivity drifts by. While Canberra and many others have built and deployed many of these devices, they have all been custom built for that particular application, and rather expensive. The Data Analyst [DA] is a general purpose device that is designed to fulfill many of these applications without modification, but can be fairly-easily modified if needed. The DA is a small [12 x 18 x 5 cm], low-power [3 W] box that accepts the input from external MCAs, controls the acquisition cycle, analyzes the results, and transmits them to the outside world when needed. The detector-MCAs supported are HPGe with Lynx MCA, NaI or CeBr or LaBr with Osprey MCA, and CZT or CsI with internal MCAs. The DA internal software used for analysis is the full standard Genie analysis software, which is very widely used and well accepted in the industry. This allows exported spectral files to be reviewed and confirmed by Experts, and reanalyzed if needed. The DA hardware is totally autonomous. As soon as power is applied, it starts the pre-programmed sequences of acquisition and analysis. Multiple analysis sequences [called Workflows] can be in operation simultaneously, e.g. with different count times and different nuclide libraries. Only the detector with MCA, and the DA are required in the field. A PC can be connected to the DA locally or remotely via WiFi, USB, or Ethernet. The PC is needed to setup the DA, and to readout the results. The DA also supports [with application-specific programming] external Inputs/Outputs either for recording with the analysis results or for use in the computation of the result, e.g. temperature, flow rate, pressure, ... ]. The DA also has an internal GPS receiver with external antenna. Applications of the DA that are discussed include stack gas effluent activity where a portion of the effluent stream was extracted to flow through a shield with a HPGe detector and Lynx MCA, and measurement of reactor coolant activity where a shielded CZT detector and MCA were aimed at various sections of reactor primary coolant during a maintenance outage. Potential other applications are also described. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Operating and Managing a Backup Control Center

Due to the criticality of continuous mission operations, some control centers must plan for alternate locations in the event an emergency shuts down the primary control center. Johnson Space Center (JSC) in Houston, Texas is the Mission Control Center (MCC) for the International Space Station (ISS). Due to Houston s proximity to the Gulf of Mexico, JSC is prone to threats from hurricanes which could cause flooding, wind damage, and electrical outages to the buildings supporting the MCC. Marshall Space Flight Center (MSFC) has the capability to be the Backup Control Center for the ISS if the situation is needed. While the MSFC Huntsville Operations Support Center (HOSC) does house the BCC, the prime customer and operator of the ISS is still the JSC flight operations team. To satisfy the customer and maintain continuous mission operations, the BCC has critical infrastructure that hosts ISS ground systems and flight operations equipment that mirrors the prime mission control facility. However, a complete duplicate of Mission Control Center in another remote location is very expensive to recreate. The HOSC has infrastructure and services that MCC utilized for its backup control center to reduce the costs of a somewhat redundant service. While labor talents are equivalent, experiences are not. Certain operations are maintained in a redundant mode, while others are simply maintained as single string with adequate sparing levels of equipment. Personnel at the BCC facility must be trained and certified to an adequate level on primary MCC systems. Negotiations with the customer were done to match requirements with existing capabilities, and to prioritize resources for appropriate level of service. Because some of these systems are shared, an activation of the backup control center will cause a suspension of scheduled HOSC activities that may share resources needed by the BCC. For example, the MCC is monitoring a hurricane in the Gulf of Mexico. As the threat to MCC increases, HOSC must begin a phased activation of the BCC, while working resource conflicts with normal HOSC activities. In a long duration outage to the MCC, this could cause serious impacts to the BCC host facility s primary mission support activities. This management of a BCC is worked based on customer expectations and negotiations done before emergencies occur. I.

Marsh, Angela L.↗

Anticipating water distribution service outages from increasing temperatures

With projected temperature increases and extreme events due to climate change for many regions of the world, characterizing the impacts of these emerging hazards on water distribution systems is necessary to identify and prioritize adaptation strategies for ensuring reliability. To aid decision-making, new insights are needed into how water distribution system reliability to climate-driven heat will change, and the proactive maintenance strategies available to combat failures. To this end, we present the model Perses, a framework that joins a water distribution network hydraulic solver with reliability models of physical assets or components to estimate temperature increase-driven failures and resulting service outages in the long term. A theoretical case study is developed using Phoenix, Arizona temperature profiles, a city with extreme temperatures and a rapidly expanding infrastructure. By end-of-century under hotter futures there are projected to be 1%–5% more pump failures, 2%–5% more PVC pipe failures, and 3%–7% more iron pipe failures (RCP 4.5–8.5) than a baseline historical temperature profile. Service outages, which constitute inadequate pressure for domestic and commercial use are projected to increase by 16%–26% above the baseline under maximum temperature conditions. The exceedance of baseline failures, when compounded across a large metro region, reveals potential challenges for budgeting, management, and maintenance. An exploration of the mitigation potential of adaptation strategies shows that expedited repair times are capable of offsetting the additional outages from climate change, but will come with a cost.

54 ENVIRONMENTAL SCIENCES↗

2011 Annual Report [WESTERN AREA POWER ADMINISTRATION]

Western’s achievements for 2011 are reported and include: Experienced a banner water year – meaning more hydropower delivered; Changed energy scheduling— to better support intermittent renewable resources; Maintained reliability— ensuring maximum use of the grid by reducing the frequency and duration of planned and unplanned outages; Connected communities— providing customers energy products and related services at cost-based rates; Managed transmission projects.

13 HYDRO ENERGY↗

Embedded Optical Sensing Systems For Distribution Transformer Monitoring

Traditional utility monitoring systems do not provide real-time visibility into the condition of transformers or accurate performance measurements. This has resulted in the use of lagging indicators, such as oil sample analysis, typically requiring expensive field visits, grid outages, and laboratory sample testing. This presentation reviews the use of optical sensing systems for managing transformers and improving grid resiliency and safety. The sensing systems allow direct internal monitoring of critical transformer components. Versatility covering different monitoring parameters of interest in embedded configurations for new transformers and a retrofittable configuration for older transformers is achieved by applying hair-thin multiplexed fiber-optic and other low-profile optical sensors in combination with a high-resolution optical readout and advanced analytics. Under an initiative funded by the DOE Office of Electricity, PARC, GE and Con Edison built, tested, and qualified commercial network transformers with embedded optical sensing systems. The parameters monitored were validated across a range of scenarios with lab instruments typically used for qualification testing. An ongoing field trial to demonstrate the robustness of the technology for remote monitoring through the industrial internet under demanding grid deployment conditions in New York City is showing promise toward scale-up of the technology. This presentation will provide an overview of the typical pain points in managing transformers and parameters for monitoring. It will also cover the requirements for highly constrained installations that need to have a larger capacity and flexible rating but that must fit into a tight space. The unique capabilities of optical sensing systems and a low-cost approach to interpreting the signals from sensors in transformers for predictive maintenance will be covered. The presentation will discuss the compatibility of the sensors in the transformer environment. It will discuss the validation testing per IEEE standards that enabled the solution to be implemented in field-deployable commercial transformers. The initial results from the field deployment and the potential for the technology to provide systematic alerts for unsafe/unexpected events will be discussed. The technology could enable utility professionals to gain information they can use to better plan for maintenance/management, and improve grid performance. This would in turn accommodate DERs and other evolving grid market dynamics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydrogen Transportation and Distributed Energy Systems Risk Assessment for Airport Facilities (CRADA 555) (Final Report)

Portland International Airport (PDX), Oregon, operated by the Port of Portland (Port) is exploring the possibility of operating a fleet of 28 fuel cell electric buses and developing a distributed energy system to support airport operations during various operating modes including large-scale power outages. This study investigates the compatibility of these two missions, which will be key to resilience management at PDX. This study also investigated the risks associated with deploying a hydrogen system that could support bus operations and be utilized during an emergency to ensure continued operation of the airport. This will be a key innovation for the deployment of hydrogen systems at airports. Utilizing the unique benefits of hydrogen infrastructure for multiple roles will aid adopters in justifying new projects and serve to demonstrate the versatility of hydrogen as an energy-carrier to a wider market.

08 HYDROGEN↗

Computation Directorate 2008 Annual Report

Whether a computer is simulating the aging and performance of a nuclear weapon, the folding of a protein, or the probability of rainfall over a particular mountain range, the necessary calculations can be enormous. Our computers help researchers answer these and other complex problems, and each new generation of system hardware and software widens the realm of possibilities. Building on Livermore's historical excellence and leadership in high-performance computing, Computation added more than 331 trillion floating-point operations per second (teraFLOPS) of power to LLNL's computer room floors in 2008. In addition, Livermore's next big supercomputer, Sequoia, advanced ever closer to its 2011-2012 delivery date, as architecture plans and the procurement contract were finalized. Hyperion, an advanced technology cluster test bed that teams Livermore with 10 industry leaders, made a big splash when it was announced during Michael Dell's keynote speech at the 2008 Supercomputing Conference. The Wall Street Journal touted Hyperion as a 'bright spot amid turmoil' in the computer industry. Computation continues to measure and improve the costs of operating LLNL's high-performance computing systems by moving hardware support in-house, by measuring causes of outages to apply resources asymmetrically, and by automating most of the account and access authorization and management processes. These improvements enable more dollars to go toward fielding the best supercomputers for science, while operating them at less cost and greater responsiveness to the customers.

99 GENERAL AND MISCELLANEOUS↗

State of Electrical Cable Aging in U.S. Nuclear Power Plants

Nuclear energy has supplied one fifth of the electricity generation in the United States for the last thirty years, but headwinds for continued contribution of nuclear to the US energy mix include the aging state of existing plants and the challenge of remaining cost competitive with energy alternative such as natural gas. As an integral component of the power, control and safety operations of a nuclear power plant, electrical cables are a significant factor in both long term and resource-efficient plant operation. The cost and practical challenge of wholesale replacement of the thousands of miles of cables in each reactor make effective management of the existing cable inventory increasingly important as the cables age in service. Total generation costs for US nuclear reactors have increased in the last decade, due in part to safety and security upgrades. Passive, long-lived structures, systems and components may be subject to aging-related degradation, necessitating increase frequency of inspection and repair/replace decisions. Costs associated with cable aging management in long-term operation can be reduced with effective cable condition monitoring technology and sufficient understanding of material aging behavior. Technical basis for confidence in cable status can reduce the frequency of cable system inspections and align cable replacement decisions with physical need. Knowledge of cable remaining useful life can allow longer term cable maintenance planning and fewer unplanned outages. As methods for relating measurable key indicators of aging with cable status develop, industry has begun to demonstrate how informed cable aging management can help to minimize costs necessary for safe, long-term operation.

light water reactors, electrical cables, nuclear p↗

Distributed Energy Resource (DER) Reliability for Backup Electric Power Systems

Hospitals, emergency services, military bases, ports, airports, industries, commercial facilities, and others rely on backup power systems to provide electricity for their critical loads during grid outages. The purpose of this report it to provide accurate reliability information on commonly deployed distributed energy resources (DERs) to improve quantitative estimates for the reliability of these backup power systems during a grid outage. A backup power system consists of DERs, an electric distribution system with its associated switches and other devices, and mechanisms to control and manage the flow of electricity. Too often, facilities and campuses fail to properly quantify the reliability of their backup power systems. DERs are assumed to be 100% reliable, with the only concern being the availability of fuel. Such assumptions can lead to gross errors in the backup system's reliability estimates, particularly for long-duration outages. This report provides a set of estimates for reliability of emergency diesel generators (EDGs), natural gas prime generators and combined heat and power (CHP) prime movers, solar photovoltaics (PV), wind turbines, and Li-ion battery energy storage systems (BESS). The estimates are derived from empirical data when available and supplemented by modeling results when needed. These reliability estimates are for the DERs ability to provide power during a grid outage, ranging from an hour to 2 weeks.

14 SOLAR ENERGY↗

Springboard Engineering's Smart Grid Controller for Non-Smart Household Electricity-Consuming Appliances (Final Technical Report)

The Smart Grid opens the door to the development of many companion technologies which will in turn enable the development of a variety of devices for household electricity-consuming appliances that can communicate with it; especially, many major appliance manufacturers (such as Whirlpool and General Electric) have made public commitments to design their appliances to be Smart Grid-compatible over the next several years. Yet during that same time period, customers will purchase many millions of long-lasting appliances which are not compatible with the Smart Grid. This research project's purpose is to bring significant Smart Grid compatibility to previously-installed appliances that were not specifically designed for any Smart Grid communications, in a way that is both economical and attractive for users who want to share in the energy cost savings and reduction of peak power demand opportunities provided by the evolving Smart Grid infrastructure. The focus of this effort is to identify and research smart control solutions which take advantage of the effective strategies of demand-response (DR) communications from utilities [including time-of-day (TOD) and peak-demand pricing options] and function apart from any need for operational changes to be designed into the non-smart appliances. Our Phase I concepts promote technological advancements for enabling devices that shift the available-use time of millions of different appliances which otherwise have no Smart Grid capability. We researched low-cost microcontroller-based ways of creating devices with the ability to: (1) maintain an accurate time and day (with no need for battery backup throughout a power outage); (2) perform two-way wired and wireless communications directly with the utility company's demand management signals, to identify both low-cost time periods as well as critical-reduction periods when the cost of energy use would otherwise be much higher; (3) measure the power usage of the connected non-smart appliance; and (4) remove power for a period of time from the appliance (such as a dehumidifier, portable heater, or pool pump) in response to both time-pricing schedule and critical peak-load information from the utility, or inform the user of a batch-type appliance (such as a clothes dryer or dishwasher) regarding the current cost associated with using the appliance. The new products that could be developed as a result of this research into new consumer-centric features and characteristics includes smart wall outlets, smart outlet power-monitoring adapters, smart load switches and smart remote electric rate indicators associated with the non-smart appliances. Our Phase I goal of determining the feasibility of the above technologies was successful. The objectives were also met of developing concepts for a family of microprocessor-based control/indicator devices that can provide the above capabilities while connected in series between an appliance and its electrical power source and/or while indicating cost-of-use status to the appliance user.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Physics-informed Data-driven Degradation and Prognostic For Hydropower System

The hydropower system is a cyber-physical system, and the industry is experiencing high operation and maintenance (O&M) costs along with increasing unplanned outages, primarily due to aging equipment and new asset loading patterns. Current (O&M) practices in asset management are predominantly reactive rather than predictive and systematic. To address these challenges, a proposed physics-informed data-driven degradation model aims to simulate the health of components in various environments. Its purpose is to accurately characterize wear and fatigue in the pilot components of hydropower systems. Additionally, the model provides informed confidence in prognostic predictions concerning asset degradation and remaining life.

13 HYDRO ENERGY↗

Use of VIIRS DNB Data to Monitor Power Outages and Restoration for Significant Weather Events

NASA fs Short-term Prediction Research and Transition (SPoRT) project operates from NASA's Marshall Space Flight Center in Huntsville, Alabama. The team provides unique satellite data to the National Weather Service (NWS) and other agencies and organizations for weather analysis. While much of its work is focused on improving short-term weather forecasting, the SPoRT team supported damage assessment and response to Hurricane Superstorm Sandy by providing imagery that highlighted regions without power. The team used data from the Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership (Suomi NPP) satellite. The VIIRS low-light sensor, known as the day-night-band (DNB), can detect nighttime light from wildfires, urban and rural communities, and other human activity which emits light. It can also detect moonlight reflected from clouds and surface features. Using real time VIIRS data collected by our collaborative partner at the Space Science and Engineering Center of the University of Wisconsin, the SPoRT team created composite imagery to help detect power outages and restoration. This blackout imagery allowed emergency response teams from a variety of agencies to better plan and marshal resources for recovery efforts. The blackout product identified large-scale outages, offering a comprehensive perspective beyond a patchwork GIS mapping of outages that utility companies provide based on customer complaints. To support the relief efforts, the team provided its imagery to the USGS data portal, which the Federal Emergency Management Agency (FEMA) and other agencies used in their relief efforts. The team fs product helped FEMA, the U.S. Army Corps of Engineers, and U.S. Army monitor regions without power as part of their disaster response activities. Disaster responders used the images to identify possible outages and effectively distribute relief resources. An enhanced product is being developed and integrated into a web mapping service (WMS) for dissemination and use by a broader end user community.

Jedlovec, Gary↗

Estimating the Spatial Distribution of Population without Power during Extreme Weather Events

One challenge in emergency preparedness and response during extreme weather events such as hurricanes and ice storms is estimating how many people may be without power and how long they could be without power. In this presentation, we will discuss a method for estimating the spatial distribution of people without power during extreme weather events. The method is based on a directional nearest-neighbor approach in which grid cells representing substation locations acquire other grid cells representing customers/population demand with respect to the capacity of each substation. We also present a method for estimating restoration time in case of an outage. The application of these methods during the 2008 hurricane season will also be discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Light Water Reactor Sustainability Program: Analysis of Pressurized Water Reactor Station Blackout Caused by External Flooding Using the RISMC Toolkit

The existing fleet of nuclear power plants is in the process of extending its lifetime and increasing the power generated from these plants via power uprates. In order to evaluate the impact of these factors on the safety of the plant, the Risk Informed Safety Margin Characterization (RISMC) project aims to provide insight to decision makers through a series of simulations of the plant dynamics for different initial conditions (e.g., probabilistic analysis and uncertainty quantification). This report focuses, in particular, on the application of a RISMC detailed demonstration case study for an emergent issue using the RAVEN and RELAP-7 tools. This case study looks at the impact of a couple of challenges to a hypothetical pressurized water reactor, including: (1) a power uprate, (2) a potential loss of off-site power followed by the possible loss of all diesel generators (i.e., a station black-out event), (3) and earthquake induces station-blackout, and (4) a potential earthquake induced tsunami flood. The analysis is performed by using a set of codes: a thermal-hydraulic code (RELAP-7), a flooding simulation tool (NEUTRINO) and a stochastic analysis tool (RAVEN) – these are currently under development at the Idaho National Laboratory.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Update on Nuclear Energy Projects and Plans in Ukraine (Meeting Report)

Following the 1986 disastrous accident at Chernobyl, gaining independence following the fall of the former Soviet Union, two revolutions, and on-going Russian intervention, Ukrainea is seeking to expand its use of commercial nuclear energy and to further reduce its dependence on Russia for energy. Nuclear energy in Ukraine has made a significant contribution toward achieving sustainable development and social goals. Ukraine is very vulnerable to the effects of climate change and nuclear is a cornerstone of the country’s effort to combat the effects. With broad support from the U.S. government, Ukraine is cooperating with the U.S. on fresh nuclear fuel supply, civilian nuclear security, outage optimization, spent fuel storage, and future nuclear technology. And is looking to tap U.S. expertise on plant management, and electric grid operations and expansion. NEIc hosted this virtual event to provide an update on nuclear energy projects and plans in Ukraine. Featured speakers included Yaroslav Demchenkov, Deputy Minister of Energy, Taras Kachka, Deputy Minister – Trade Representative, Petro Kotin, CEO, Energoatom,d and Ann K. Ganzer, Senior Bureau Official, Bureau of International Security and Nonproliferation, U.S. Dept. of State. Maria Korsnick, NEI CEO, moderated the discussion. About forty individuals attended representing the Ukraine and U.S. governments, and U.S. suppliers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Valuing the Resilience Provided by Solar and Battery Energy Storage Systems

This paper explores the impact of valuing resilience on the economics of photovoltaics (PV) and storage systems for commercial buildings. The analysis presented here illustrates that accounting for the cost of grid power outages can change the breakeven point for PV and storage system investment, and increase the size of systems designed to deliver the greatest economic benefit over time. In other words, valuing resilience can make PV and storage systems economical in cases where they would not be otherwise. As storage costs decrease, and outages occur more frequently, PV and storage are likely to play a larger role in building design and management considerations.

14 SOLAR ENERGY↗