Effect of orifice size and heat-transfer rate on measured static pressures in a low-density arc-heated wind tunnel
Orifice effect on heat transfer and pressure measurements in low density wind tunnel
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Orifice effect on heat transfer and pressure measurements in low density wind tunnel
Experiments are performed in choked circular hot and cold nitrogen jets issuing from a 2.44 cm diameter sharp-edged orifice at a fully expanded jet Mach number of 1.85 in an effort to investigate the character of screech phenomenon. The stagnation temperature of the cold and the hot jets are 299 K and 319 K respectively. The axial distribution of the centerline Mach number was obtained with a pitot tube, while the screech data (frequency and amplitude) at different axial and radial stations were measured with the aid of microphones. The fundamental screech frequency of the hot jet is slightly increased relative to that of the cold jet. It is concluded that temperature effects on the screech amplitude are manifested with regard to the fundamental and the subharmonic even at relatively small temperature range considered.
Understanding the hydrodynamics of adiabatic two-phase flows in packed bed reactors offers numerous benefits. It enables the optimization of chemical reactions rates and products, crucial for pharmaceuticals and energy production industries. Additionally, this understanding aids in designing more efficient and compact reactors, reducing space and resource requirements. Insights gained from studying such flows in microgravity contribute to advancements of space technologies and the enhancement of our capabilities for undertaking future long duration safe, and sustainable space exploration missions. The Packed Bed Reactor Experiment-Water Recovery Series (PBRE-WRS) is a flight experiment planned for operation on the Microgravity Science Glove box (MSG) facility of the International Space Station (ISS). The objective of the experiment is to validate hydrodynamic models at a range of gas and liquid flow rates. The microgravity environment allows for measurement and observation of aspects of fluid dynamics that are unique when compared to observations made in full or partial gravity environments. The experiment consists of testing two-phase flow hydrodynamics in three different filters, four (4) orifices and one check valve test articles. The experiment utilizes the hardware of the previously flown PBRE and PBRE-2 with packed beds of different packings materials and sizes. The fluid system of the PBRE-WRS consists of a nitrogen gas delivery and water delivery subsystems. The gas delivery subsystem can accommodate two ranges of gas flow rates, just as for the water delivery system. The nitrogen gas loop is open whereas the water loop is closed. Gas is separated from the water using a gas-liquid phase separator which is located in the water delivery module. Preliminary results from ground testing show the pressure drop increasing at different rates with the liquid and gas flow rates in the Brine filter. In this work, a detailed system description is presented along with a summary of results from ground performance testing of different test sections in an end-to-end preflight testing campaign.
Understanding the hydrodynamics of adiabatic two-phase flows in packed bed reactors offers numerous benefits. It enables the optimization of chemical reactions rates and products which results in more efficient and compact reactors, thus reducing space and resource requirements, crucial for long duration space missions. The Packed Bed Reactor Experiment-Water Recovery Series (PBRE-WRS) is a flight experiment planned for operation on the Microgravity Science Glove box (MSG) facility of the International Space Station (ISS). The objective of the experiment is to validate hydrodynamic models at a range of gas and liquid flow rates, where these models are used in the design of processes for life support systems in microgravity. The microgravity environment allows for measurement and observation of aspects of fluid dynamics that are unique when compared to observations made in full or partial gravity environments. The experiment consists of testing two-phase flow hydrodynamics in three different filters, four (4) orifices and one check valve test articles. The experiment utilizes the hardware of the previously flown PBRE and PBRE-2 with packed beds of different packings materials and sizes. The fluid system of the PBRE-WRS consists of a nitrogen gas delivery and water delivery subsystems. The gas delivery subsystem can accommodate two ranges of gas flow rates, just as for the water delivery system. The nitrogen gas loop is open whereas the water loop is closed. Gas is separated from the water using a gas-liquid phase separator which is located in the water delivery module. Preliminary results from ground testing show the pressure drop across the filters increasing at different rates with the liquid and gas flow rates. In this work, a detailed system description is presented along with a summary of results from ground performance testing of different test sections in an end-to-end preflight testing campaign.
Understanding the hydrodynamics of adiabatic two-phase flows in packed bed reactors enables the optimization of chemical reaction rates and products that crucial in pharmaceuticals and energy production industries. Additionally, this understanding aids in designing more efficient and compact reactors and reducing space and resource requirements. Insights gained from studying and understanding such flows in microgravity contribute to advancements of space technologies and the enhancement of our capabilities for undertaking future long duration safe, and sustainable space exploration missions. The objective of the Packed Bed Reactor Experiment series (PBRE and PBRE-2) was to develop a fundamental understanding of the hydrodynamics of adiabatic two-phase flows through porous media in microgravity. This work provides a description of the PBRE fluid system and presents the highlights of the PBRE and PBRE-2 previously flown with different packings and operated onboard of the International Space Station Microgravity Science Glovebox (ISS-MSG). These highlights include flow patterns and two-phase pressure drop, and the impact of capillary effects on pressure drop at various gas and liquid flow rates. This work also presents preliminary results from the Packed Bed Reactor Experiment-Water Recovery Series (PBRE-WRS) recently flown with filters and orifices, which was also operated on the ISS-MSG. The objective of the experiment is to validate hydrodynamic models at a range of gas and liquid flow rates pertinent to the operation of these test articles. The microgravity environment allows for measurement and observation of aspects of fluid dynamics that are unique when compared to observations made in full or partial gravity environments.
A technique for evaluating the dynamic characteristics of free-liquid jets on a comparative basis is presented. This method consists of determining the pressure distribution produced by the perpendicular impingement of a jet upon a flat plate and using these data for comparing and categorizing jets with unknown properties in terms of similar data produced by jets having known characteristics-i.e., with jets produced by fully developed turbulent flow, fully developed laminar flow, and a jet having a near-uniform velocity profile. The visual characteristics, as well as both the mean and the fluctuating pressure distributions, are presented for these three reference configurations and for a number of jets produced by orifices having varying length-diameter ratios, combined with varying degrees of surface roughness in the initial five diameters of straight bore.
Solutions for knudsen flow flux distributions with particles entering circular tube through small axial orifice - rocket thrustor application
Exhaust of pinched plasma from axial orifice involves electromagnetic current profile diffraction and thermal expansion of gas column
Exhaust of pinched plasma from axial orifice involves electromagnetic current profile diffraction and thermal expansion of gas column
Cesium vapor flow from orifices and tubes into vacuum analyzed, noting dependence of angular distribution and center line intensity on Knudsen numbers
Installation and fairing of flush, static pressure orifices on wing surfaces of supersonic aircraft
Computer calculation of spacecraft compartment dynamic pressure with orifices and outgassing materials
Scaling and similarity study of liquids discharged from containers through orifices and tubes
Dynamic transient pressure of spacecraft compartment containing outgassing materials and orifice passages exposed to known external pressure profile
Multiple-orifice throttle valve is not subject to cold welding in a vacuum environment and is compatible with strong oxidizing fluid. The valve is of all metal construction using simple components that do not slide or rotate and excludes static or dynamic seals.
Optimum design and testing of injector orifices
Flow characteristics of orifices for venting launch vehicle compartments
Approximated gas flow rate through subsonic orifices