Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Gimballed Tracking Mount Pointing Angle Qualification

Tonopah Test Range (TTR), in support of its testing mission and modernization effort acquired a fleet of new gimballed tracking mounts (GTMs) manufactured by BAE Systems. The new GTMs can be operated remotely during flight tests and provide near real-time target tracking data. Furthermore, test vehicle Time-Space-Position-Information (TSPI) is evaluated using post-test synchronized imagery and pointing angle measurements acquired from each tracking mount. To comply with the Nuclear Enterprise Assurance Program (NEAP), all measurements devices must be certified. In keeping with the NEAP program, qualification of the new GTMs have been assessed to confirm that their pointing angle measurements produce acceptable TSPI results. This study only evaluated the four GTMs as a stand-alone solution and found that the GTMs meet their performance requirement of 0.006 degrees RMS error (or less) for post-processed pointing angles and produced TSPI solution with error volumes on the order of one meter or less. The new GTMs will be utilized in combination with existing optical tracking mounts, which will only improve the accuracy of the resulting TSPI data product. Details regarding the approach, analysis, summary results, and conclusions are presented.

42 ENGINEERING↗

Photon Counting Using Edge-Detection Algorithm

New applications such as high-datarate, photon-starved, free-space optical communications require photon counting at flux rates into gigaphoton-per-second regimes coupled with subnanosecond timing accuracy. Current single-photon detectors that are capable of handling such operating conditions are designed in an array format and produce output pulses that span multiple sample times. In order to discern one pulse from another and not to overcount the number of incoming photons, a detection algorithm must be applied to the sampled detector output pulses. As flux rates increase, the ability to implement such a detection algorithm becomes difficult within a digital processor that may reside within a field-programmable gate array (FPGA). Systems have been developed and implemented to both characterize gigahertz bandwidth single-photon detectors, as well as process photon count signals at rates into gigaphotons per second in order to implement communications links at SCPPM (serial concatenated pulse position modulation) encoded data rates exceeding 100 megabits per second with efficiencies greater than two bits per detected photon. A hardware edge-detection algorithm and corresponding signal combining and deserialization hardware were developed to meet these requirements at sample rates up to 10 GHz. The photon discriminator deserializer hardware board accepts four inputs, which allows for the ability to take inputs from a quadphoton counting detector, to support requirements for optical tracking with a reduced number of hardware components. The four inputs are hardware leading-edge detected independently. After leading-edge detection, the resultant samples are ORed together prior to deserialization. The deserialization is performed to reduce the rate at which data is passed to a digital signal processor, perhaps residing within an FPGA. The hardware implements four separate analog inputs that are connected through RF connectors. Each analog input is fed to a high-speed 1-bit comparator, which digitizes the input referenced to an adjustable threshold value. This results in four independent serial sample streams of binary 1s and 0s, which are ORed together at rates up to 10 GHz. This single serial stream is then deserialized by a factor of 16 to create 16 signal lines at a rate of 622.5 MHz or lower for input to a high-speed digital processor assembly. The new design and corresponding hardware can be employed with a quad-photon counting detector capable of handling photon rates on the order of multi-gigaphotons per second, whereas prior art was only capable of handling a single input at 1/4 the flux rate. Additionally, the hardware edge-detection algorithm has provided the ability to process 3-10 higher photon flux rates than previously possible by removing the limitation that photoncounting detector output pulses on multiple channels being ORed not overlap. Now, only the leading edges of the pulses are required to not overlap. This new photon counting digitizer hardware architecture supports a universal front end for an optical communications receiver operating at data rates from kilobits to over one gigabit per second to meet increased mission data volume requirements.

Gin, Jonathan W.↗

Controlled Organization of Inorganic Materials Using Biological Molecules for Activating Therapeutic Functionalities

Precise control over the assembly of biocompatible three-dimensional (3D) nanostructures would allow for programmed interactions within the cellular environment. Nucleic acids can be used as programmable crosslinkers to direct the assembly of quantum dots (QDs) and tuned to demonstrate different interparticle binding strategies. In this work, morphologies of self-assembled QDs are evaluated via gel electrophoresis, transmission electron microscopy, small-angle X-ray scattering, and dissipative particle dynamics simulations, with all results being in good agreement. The controlled assembly of 3D QD organizations is demonstrated in cells via the colocalized emission of multiple assembled QDs, and their immunorecognition is assessed via enzyme-linked immunosorbent assays. RNA interference inducers are also embedded into the interparticle binding strategy to be released in human cells only upon QD assembly, which is demonstrated by specific gene silencing. The programmability and intracellular activity of QD assemblies offer a strategy for nucleic acids to imbue the structure and therapeutic function into the formation of complex networks of nanostructures, while the photoluminescent properties of the material allow for optical tracking in cells in vitro.

36 MATERIALS SCIENCE↗

Revealing and Engineering Assembly Pathways of 3D DNA Origami Crystals

Recent developments in nanomaterial self-assembly demonstrate the capability to create tailored nanostructures by engineering both the binding coordination and specificity of interactions between material subunits. DNA origami frames allow for the design and fabrication of a broad variety of ordered 3D nanoscale architectures through self-assembly, facilitated by frame-to-frame bonds with designable strength and specificity. While the bond design is critical to lattice formation, the assembly process itself is often dependent on a thermal pathway. Highly ordered nanoscale frameworks, assembled from DNA frames, are predominantly crystallized through thermal annealing pathways that typically follow a “slow” cooling approach, with experiments on the time scale of days yielding DNA origami crystals in the range of 1−10 μm. This extended assembly time scale hinders the study of crystal formation pathways, necessitating a deeper understanding of factors governing successful annealing. Lack of insight into time scale also presents a practical limitation for material fabrication. Here, we investigate key factors affecting lattice assembly pathways and demonstrate that precise engineering of assembly conditions greatly reduces assembly times by up to nearly 2 orders of magnitude. We evaluate the nucleation and growth of crystals via optical and electron microscopy, and small-angle X-ray scattering techniques, mapping the time−temperature-transformation of superlattices from the melt through single-crystal optical tracking. The results show that origami frame assembly can be described by classical nucleation and growth theory, which can, in turn, be used to prescribe the growth of the crystals. Lastly, these findings are applied to demonstrate thermal pathway-dependent assembly, forming distinct assemblies based on different thermal annealing profiles.

36 MATERIALS SCIENCE↗

Exploring fingerprints of ultrafast structural dynamics in molecular solutions with an X-ray laser

We apply ultrashort x-ray laser pulses to track optically excited structural dynamics of [Ir 2 (dimen) 4 ] 2+ molecules in solution. In our exploratory study we determine angular correlations in the scattered x-rays, which comprise a complex fingerprint of the ultrafast dynamics. Model-assisted analysis of the experimental correlation data allows us to elucidate various aspects of the photoinduced changes in the excited molecular ensembles. We unambiguously identify that in our experiment the photoinduced transition dipole moments in [Ir 2 (dimen) 4 ] 2+ molecules are oriented perpendicular to the Ir-Ir bond. The analysis also shows that the ground state conformer of [Ir 2 (dimen) 4 ] 2+ with a larger Ir–Ir distance is mostly responsible for the formation of the excited state. We also reveal that the ensemble of solute molecules can be characterized with a substantial structural heterogeneity due to solvent influence. In conclusion, the proposed x-ray correlation approach offers an alternative path for studies of ultrafast structural dynamics of molecular ensembles in the liquid and gas phases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct quantification of ion composition and mobility in organic mixed ionic-electronic conductors

Ion transport in organic mixed ionic-electronic conductors (OMIECs) is crucial due to its direct impact on device response time and operating mechanisms but is often assessed indirectly or necessitates extra assumptions. Operando x-ray fluorescence (XRF) is a powerful, direct probe for elemental characterization of bulk OMIECs and was used to directly quantify ion composition and mobility in a model OMIEC, poly(3,4-ethylenedioxythiophene)-poly(styrene sulfonate) (PEDOT:PSS), during device operation. The first cycle revealed slow electrowetting and cation-proton exchange. Subsequent cycles showed rapid response with minor cation fluctuation (~5%). Comparison with optical-tracked electrochromic fronts revealed mesoscale structure–dependent proton transport. The calculated effective ion mobility demonstrated thickness-dependent behavior, emphasizing an interfacial ion transport pathway with a higher mobile ion density. The decoupling of interfacial effects on bulk ion mobility and the decoupling of cation and proton migration elucidate ion transport in conventional and emerging OMIEC-based devices and has broader implications for other ionic conductors writ large.

42 ENGINEERING↗

Electron Beam Irradiation for Water Treatment of Per- and Polyfluoroalkyl Substances (PFAS)

Per- and polyfluoroalkyl substances (PFAS) are widely used but are now considered a water contamination risk. Fermi National Accelerator Laboratory’s IARC group has demonstrated that passing water through electron beam radiation can destroy PFAS. This project aims to develop a process to scale the system for bulk water treatment. The key is efficient radiation usage, ensuring that all water receives only the minimum dose. Software was developed for this purpose, consisting of a computational fluid dynamics model (CFD) in COMSOL, which calculates particle trajectories through the radiation area. A MATLAB script integrates the radiation dose of these particles, and statistical analysis is performed to evaluate the radiation utilization efficiency. These models are validated with a flow test where colored dye is injected and optically tracked. Radiation dose is measured by testing under an e-beam to measure the degradation of a PFAS analog.

Mueller, Scott [Northern Illinois U.]↗

Tests and comparisons of gravity models.

Optical observations of the GEOS satellites were used to obtain orbital solutions with different sets of geopotential coefficients. The solutions were compared before and after modification to high order terms (necessary because of resonance) and were then analyzed by comparing subsequent observations with predicted trajectories. The most important source of error in orbit determination and prediction for the GEOS satellites is the effect of resonance found in most published sets of geopotential coefficients. Modifications to the sets yield greatly improved orbits in most cases. The results of these comparisons suggest that with the best optical tracking systems and gravity models, satellite position error due to gravity model uncertainty can reach 50-100 m during a heavily observed 5-6 day orbital arc. If resonant coefficients are estimated, the uncertainty is reduced considerably.

Marsh, J. G.↗

Wave transmission characteristics and anisotropy of canine carotid arteries

A method was developed to generate and record three types of small amplitude waves (pressure, torsion and axial) in the exposed carotid artery of anesthetized dogs. The pressure waves were studied with the aid of miniature pressure transducers; electro-optical tracking units monitored the axial and circumferential surface displacements. Results from 6 dogs are presented in the form of the phase velocities and attenuation of three types of waves. The data demonstrate incompatibility with an isotropic elastic model for the mechanical behavior of the artery. The measured damping appears to be primarily due to the viscoelastic properties of the vessel wall material.

Moritz, W. E.↗

Accuracy of estimating the masses of Phobos and Deimos from multiple Viking orbiter encounters

The problem was investigated of estimating the masses of Phobos and Deimos from Doppler and onboard optical measurements during the Viking extended mission. A Kalman filter was used to analyze the effects of gravitational uncertainties and nongravitational accelerations. These accelerations destroy the dynamical integrity of the orbit, and multibatch or limited memory filtering is preferred to single batch processing. Optical tracking is essential to improve the relative orbit geometry. The masses can be determined to about 10% and 25% respectively for Phobos and Deimos, assuming satellite densities of about 3 gr/cu cm.

Tolson, R. H.↗