Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “online”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A Codesign Framework for Online Data Analysis and Reduction at the Exascale

In this paper we discuss our design of a toolset for automating performance studies of composed HPC applications that perform online data reduction and analysis. We describe Cheetah, a new framework for performing parametric studies on coupled applications. Cheetah facilitates understanding the impact of various factors such as process placement, synchronicity of algorithms, and storage vs. compute requirements for online analysis of large data. Ultimately, we aim to create a catalog of performance results that can help scientists understand tradeos when designing next-generation simulations that make use of online processing techniques. We illustrate the design choices of Cheetah by using a reaction-diusion simulation (Gray-Scott) paired with an analysis application to demonstrate initial results of fine-grained process placement on Summit, a pre-exascale supercomputer at Oak Ridge National Laboratory

Cheetah↗

Two-dimensional liquid chromatography system for online top-down mass spectrometry

An online metal-free weak cation exchange-hydrophilic interaction liquid chromatography/reversed phase liquid chromatography (WCX-HILIC/RPLC) system has been developed for sensitive high-throughput top-down mass spectrometry. Analyzing posttranslational modifications (PTMs) of core histones, with focus on histone H4, tested the system. Using ~24 μg of core histones (H4, H2B, H2A and H3) purified from human fibroblasts, 41 H4 isoforms were identified, with the type and locations of PTMs unambiguously mapped for 20 of these variants. Compared to corresponding offline studies reported previously, online WCXHILIC/ RPLC platform offers significant improvement in sensitivity, with several orders of magnitude reduction in sample requirements and reduction in the overall analysis time. To the best of our knowledge, this study represents the first online two-dimensional (2D) LC-MS/MS characterization of core histone mixture at the intact protein level.

59 BASIC BIOLOGICAL SCIENCES↗

Photo-induced inhibition of insulin amyloid fibrillation on online laser measurement

Highlights: {yields} We compare the structures of insulin upon heating with or without laser irradiation. {yields} Laser irradiation inhibits insulin fibrillation and may be of insert for mechanistic disease studies. {yields} Online laser measurements should be carefully used in the study of amyloid proteins. -- Abstract: Protein aggregation and amyloid fibrillation can lead to several serious diseases and protein drugs ineffectiveness; thus, the detection and inhibition of these processes have been of great interest. In the present study, the inhibition of insulin amyloid fibrillation by laser irradiation was investigated using dynamic light scattering (DLS), transmission electron microscopy (TEM), far-UV circular dichroism (far-UV CD), and thioflavin T (ThT) fluorescence. During heat-induced aggregation, the size distribution of two insulin solutions obtained by online and offline dynamic light scattering were different. The laser-on insulin in the presence of 0.1 M NaCl exhibited fewer fibrils than the laser-off insulin, whereas no insulin fibril under laser irradiation was observed in the absence of 0.1 M NaCl for 45 h incubation. Moreover, our CD results showed that the laser-irradiated insulin solution maintained mainly an {alpha}-helical conformation, but the laser-off insulin solution formed bulk fibrils followed by a significant increase in {beta}-sheet content for 106 h incubation. These findings provide an inhibition method for insulin amyloid fibrillation using the laser irradiation and demonstrate that the online long-time laser measurements should be carefully used in the study of amyloid proteins because they may change the original results.

60 APPLIED LIFE SCIENCES↗

A machine learning based approach to online electron reconstruction at CLAS12

Online reconstruction is key for monitoring purposes and real time analysis in High Energy and Nuclear Physics experiments. A necessary component of reconstruction algorithms is particle identification that combines information left by a particle passing through several detector components to identify the particle’s type. Of particular interest to electro-production Nuclear Physics experiments such as CLAS12 is electron identification which is used to trigger data recording. A machine learning approach was developed for CLAS12 to reconstruct and identify electrons by combining raw signals at the data acquisition level from several detector components. Here, this approach achieves an electron identification purity above 75% whilst retaining an efficiency close to 100%. The machine learning tools are capable of running at high rates exceeding the data acquisition rates and will allow electron reconstruction in real-time. This work enhances online analyses and monitoring and can contribute to improved triggering at CLAS12. This machine learning driven approach will also be crucial for experiments aiming to transition to streaming readout operations where online reconstruction will be a key component of the data taking paradigm.

Artificial intelligence↗

Rules of the rooftop: Platform design and price reductions in an online solar photovoltaic marketplace in the United States

Residential solar photovoltaic (PV) customers typically obtain price quotes directly from installers, a process with high consumer search costs that enable price dispersion and can discourage adoption. Recently, however, customers are increasingly shopping for PV using third-party online platforms that make it easier to obtain and compare quotes from multiple installers. While early evidence indicates that these platforms make the PV market more transparent and lower prices, the literature suggests that market outcomes are critically linked to detailed aspects of platform design. In this study, we econometrically analyze a unique dataset of quotes offered in the online PV marketplace EnergySage to investigate how four changes to the platform design have influenced quote prices and transaction prices. We find that the largest reductions in quote prices ($0.11/ W) and transaction prices ($0.15/W) were associated with the introduction of a price guidance information feature for installers. While educating and informing customers has repeatedly emerged as a policy priority for bolstering PV markets, these results suggest that the same should be true on the supply side. We also find that customers are willing to pay higher transaction prices for systems with higher-quality panels, dispelling concerns that online PV marketplaces lead to a 'race to the bottom' phenomenon by emphasizing price at the expense of quality.

14 SOLAR ENERGY↗

Identification and Online Updating of Dynamic Models for Demand Response of an Industrial Air Separation Unit

Demand-response operation of air separation units requires frequent changes in production rate(s), and scheduling calculations must explicitly consider process dynamics to ensure feasibility of the solutions. To this end, scale-bridging models (SBMs) approximate the scheduling-relevant dynamics of a process and its controller in a low-order representation. In contrast to previous works that have employed nonlinear SBMs, this paper proposes linear SBMs, developed using time-series analysis, to facilitate online scheduling computations. Using a year-long industrial dataset, we nd that compact linear SBMs are suitable approximations over typical scheduling horizons, but that their accuracies are unpredictable over time. We introduce a strategy for online updating of the SBMs, based on Kalman ltering schemes for online parameter estimation. The approach greatly improves the accuracy of SBM predictions and will enable the use of linear SBM-based demand-response scheduling in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Online Adaptive Radiotherapy for Muscle-Invasive Bladder Cancer: Results of a Pilot Study

Purpose: To determine the advantages and disadvantages of daily online adaptive image-guided radiotherapy (RT) compared with conventional RT for muscle-invasive bladder cancer. Methods and Materials: Twenty-seven patients with T2-T4 transitional cell carcinoma of the bladder were treated with daily online adaptive image-guided RT using cone-beam computed tomography (CBCT). From day 1 daily soft tissue-based isocenter positioning was performed using CBCT images acquired before treatment. Using a composite of the initial planning CT and the first five daily CBCT scans, small, medium, and large adaptive plans were created. Each of these adaptive plans used a 0.5-cm clinical target volume (CTV) to planning target volume expansion. For Fractions 8-32, treatment involved daily soft tissue-based isocenter positioning and selection of suitable adaptive plan of the day. Treating radiation therapists completed a credentialing program, and one radiation oncologist performed all the contouring. Comparisons were made between adaptive and conventional treatment on the basis of CTV coverage and normal tissue sparing. Results: All 27 patients completed treatment per protocol. Bladder volume decreased with time or fraction number (p < 0.0001). For the adaptive component (Fractions 8-32) the small, medium, large, and conventional plans were used in 9.8%, 49.2%, 39.5%, and 1.5% of fractions, respectively. For the adaptive strategy, 2.7% of occasions resulted in a CTV V95 <99%, compared with 4.8% of occasions for the conventional approach (p = 0.42). Mean volume of normal tissue receiving a dose >45 Gy was 29% (95% confidence interval, 24-35%) less with adaptive RT compared with conventional RT. The mean volume of normal tissue receiving >5 Gy was 15% (95% confidence interval, 11-18%) less with adaptive RT compared with conventional RT. Conclusions: Online adaptive radiotherapy is feasible in an academic radiotherapy center. The volume of normal tissue irradiated can be significantly smaller without reducing CTV coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Oncology and Online Patient Education Materials: Deviating From NIH and AMA Recommendations

Purpose: Physicians encourage patients to be informed about their health care options, but much of the online health care–related resources can be beneficial only if patients are capable of comprehending it. This study's aim was to assess the readability level of online patient education resources for radiation oncology to conclude whether they meet the general public's health literacy needs as determined by the guidelines of the United States National Institutes of Health (NIH) and the American Medical Association (AMA). Methods: Radiation oncology–related internet-based patient education materials were downloaded from 5 major professional websites (American Society for Radiation Oncology, American Association of Physicists in Medicine, American Brachytherapy Society, (RadiologyInfo.org), and Radiation Therapy Oncology Group). Additional patient education documents were downloaded by searching for key radiation oncology phrases using Google. A total of 135 articles were downloaded and assessed for their readability level using 10 quantitative readability scales that are widely accepted in the medical literature. Results: When all 10 assessment tools for readability were taken into account, the 135 online patient education articles were written at an average grade level of 13.7 ± 2.0. One hundred nine of the 135 articles (80.7%) required a high school graduate's comprehension level (12th-grade level or higher). Only 1 of the 135 articles (0.74%) met the AMA and NIH recommendations for patient education resources to be written between the third-grade and seventh-grade levels. Conclusion: Radiation oncology websites have patient education material written at an educational level above the NIH and AMA recommendations; as a result, average American patients may not be able to fully understand them. Rewriting radiation oncology patient education resources would likely contribute to the patients' understanding of their health and treatment options, making each physician-patient interaction more productive and efficient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulated Online Adaptive Magnetic Resonance–Guided Stereotactic Body Radiation Therapy for the Treatment of Oligometastatic Disease of the Abdomen and Central Thorax: Characterization of Potential Advantages

Purpose: To characterize potential advantages of online-adaptive magnetic resonance (MR)-guided stereotactic body radiation therapy (SBRT) to treat oligometastatic disease of the non-liver abdomen and central thorax. Methods and Materials: Ten patients treated with RT for unresectable primary or oligometastatic disease of the non-liver abdomen (n=5) or central thorax (n=5) underwent imaging throughout treatment on a clinical MR image guided RT system. The SBRT plans were created on the basis of tumor/organ at risk (OAR) anatomy at initial computed tomography simulation (P{sub I}), and simulated adaptive plans were created on the basis of observed MR image set tumor/OAR “anatomy of the day” (P{sub A}). Each P{sub A} was planned under workflow constraints to simulate online-adaptive RT. Prescribed dose was 50 Gy/5 fractions, with goal coverage of 95% planning target volume (PTV) by 95% of the prescription, subject to hard OAR constraints. The P{sub I} was applied to each MR dataset and compared with P{sub A} to evaluate changes in dose delivered to tumor/OARs, with dose escalation when possible. Results: Hard OAR constraints were met for all P{sub Is} based on anatomy from initial computed tomography simulation, and all P{sub As} based on anatomy from each daily MR image set. Application of the P{sub I} to anatomy of the day caused OAR constraint violation in 19 of 30 cases. Adaptive planning increased PTV coverage in 21 of 30 cases, including 14 cases in which hard OAR constraints were violated by the nonadaptive plan. For 9 P{sub A} cases, decreased PTV coverage was required to meet hard OAR constraints that would have been violated in a nonadaptive setting. Conclusions: Online-adaptive MRI-guided SBRT may allow PTV dose escalation and/or simultaneous OAR sparing compared with nonadaptive SBRT. A prospective clinical trial is underway at our institution to evaluate clinical outcomes of this technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Online and noninvasive monitoring of battery health at negative-half cell in all-vanadium redox flow batteries using ultrasound

Hydrogen evolution is one of the major side reactions that is detrimental to the health of all-vanadium redox flow batteries, especially for long-term cycling. Effective, low-cost, and accurate online prediction and detection methods for hydrogen generation are not yet available. In this work, we designed an online, noninvasive ultrasonic probing approach for monitoring the state of charge (SoC), predicting the hydrogen generation, and detecting hydrogen gas bubbles in anolyte solutions. The technique employs a pulse-echo method to measure the sound speed and the acoustic attenuation coefficient of the anolyte solution. Through static offline experiments and online in operando experiments, we have demonstrated that when hydrogen gas is generated in anolyte solutions, large variations are observed in both sound speed and acoustic attenuation coefficient measurements. We found that the variations of acoustic attenuation coefficient are highly correlated (correlation coefficients >0.9) with the gas flow rate. In conclusion, the designed acoustic method can monitor the SoC of anolyte, predict the hydrogen generation, and detect the presence of gas bubbles in an anolyte solution and, thus, provide information about the state of health for operation and management of flow battery systems.

25 ENERGY STORAGE↗

Online Kidney Position Verification Using Non-Contrast Radiographs on a Linear Accelerator with on Board KV X-Ray Imaging Capability

The kidneys are dose-limiting organs in abdominal radiotherapy. Kilovoltage (kV) radiographs can be acquired using on-board imager (OBI)-equipped linear accelerators with better soft tissue contrast and lower radiation doses than conventional portal imaging. A feasibility study was conducted to test the suitability of anterior-posterior (AP) non-contrast kV radiographs acquired at treatment time for online kidney position verification. Anthropomorphic phantoms were used to evaluate image quality and radiation dose. Institutional Review Board approval was given for a pilot study that enrolled 5 adults and 5 children. Customized digitally reconstructed radiographs (DRRs) were generated to provide a priori information on kidney shape and position. Radiotherapy treatment staff performed online evaluation of kidney visibility on OBI radiographs. Kidney dose measured in a pediatric anthropomorphic phantom was 0.1 cGy for kV imaging and 1.7 cGy for MV imaging. Kidneys were rated as well visualized in 60% of patients (90% confidence interval, 34-81%). The likelihood of visualization appears to be influenced by the relative AP separation of the abdomen and kidneys, the axial profile of the kidneys, and their relative contrast with surrounding structures. Online verification of kidney position using AP non-contrast kV radiographs on an OBI-equipped linear accelerator appears feasible for patients with suitable abdominal anatomy. Kidney position information provided is limited to 2-dimensional 'snapshots,' but this is adequate in some clinical situations and potentially advantageous in respiratory-correlated treatments. Successful clinical implementation requires customized partial DRRs, appropriate imaging parameters, and credentialing of treatment staff.

61 RADIATION PROTECTION AND DOSIMETRY↗

An algorithm for online optimization of accelerators

We developed a general algorithm for online optimization of accelerator performance, i.e., online tuning, using the performance measure as the objective function. This method, named robust conjugate direction search (RCDS), combines the conjugate direction set approach of Powell's method with a robust line optimizer which considers the random noise in bracketing the minimum and uses parabolic fit of data points that uniformly sample the bracketed zone. Moreover, it is much more robust against noise than traditional algorithms and is therefore suitable for online application. Simulation and experimental studies have been carried out to demonstrate the strength of the new algorithm.

43 PARTICLE ACCELERATORS↗

Experience with dynamic resource provisioning of the CMS online cluster using a cloud overlay

The primary goal of the online cluster of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) is to build event data from the detector and to select interesting collisions in the High Level Trigger (HLT) farm for offline storage. With more than 1500 nodes and a capacity of about 850 kHEPSpecInt06, the HLT machines represent similar computing capacity of all the CMS Tier1 Grid sites together. Moreover, it is currently connected to the CERN IT datacenter via a dedicated 160 Gbps network connection and hence can access the remote EOS based storage with a high bandwidth. In the last few years, a cloud overlay based on OpenStack has been commissioned to use these resources for the WLCG when they are not needed for data taking. This online cloud facility was designed for parasitic use of the HLT, which must never interfere with its primary function as part of the DAQ system. It also allows to abstract from the different types of machines and their underlying segmented networks. During the LHC technical stop periods, the HLT cloud is set to its static mode of operation where it acts like other grid facilities. The online cloud was also extended to make dynamic use of resources during periods between LHC fills. These periods are a-priori unscheduled and of undetermined length, typically of several hours, once or more a day. For that, it dynamically follows LHC beam states and hibernates Virtual Machines (VM) accordingly. Finally, this work presents the design and implementation of a mechanism to dynamically ramp up VMs when the DAQ load on the HLT reduces towards the end of the fill.

97 MATHEMATICS AND COMPUTING↗

A scintillator-based online detector for the angularly resolved measurement of laser-accelerated proton spectra

In recent years, a new generation of high repetition rate ({approx}10 Hz), high power ({approx}100 TW) laser systems has stimulated intense research on laser-driven sources for fast protons. Considering experimental instrumentation, this development requires online diagnostics for protons to be added to the established offline detection tools such as solid state track detectors or radiochromic films. In this article, we present the design and characterization of a scintillator-based online detector that gives access to the angularly resolved proton distribution along one spatial dimension and resolves 10 different proton energy ranges. Conceived as an online detector for key parameters in laser-proton acceleration, such as the maximum proton energy and the angular distribution, the detector features a spatial resolution of {approx}1.3 mm and a spectral resolution better than 1.5 MeV for a maximum proton energy above 12 MeV in the current design. Regarding its areas of application, we consider the detector a useful complement to radiochromic films and Thomson parabola spectrometers, capable to give immediate feedback on the experimental performance. The detector was characterized at an electrostatic Van de Graaff tandetron accelerator and tested in a laser-proton acceleration experiment, proving its suitability as a diagnostic device for laser-accelerated protons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a single-shot-imaging thin film for an online Thomson parabola spectrometer

A single-shot-imaging thin scintillator film was developed for an online Thomson parabola (TP) spectrometer and the first analysis of laser accelerated ions, using the online TP spectrometer, was demonstrated at the JAEA-Kansai Advanced Relativistic Engineering Laser System (J-KAREN). An energy spectrum of {approx}4.0 MeV protons is obtained using only this imaging film without the need of a microchannel plate that is typically utilized in online ion analyses. A general-purpose Monte Carlo particle and heavy ion-transport code system, which consists of various quantum dynamics models, was used for the prediction of the luminescent properties of the scintillator. The simulation can reasonably predict not only the ion trajectories detected by the spectrometer, but also luminescence properties.

36 MATERIALS SCIENCE↗

An accurate online calibration system based on combined clamp-shape coil for high voltage electronic current transformers

Electronic transformers are widely used in power systems because of their wide bandwidth and good transient performance. However, as an emerging technology, the failure rate of electronic transformers is higher than that of traditional transformers. As a result, the calibration period needs to be shortened. Traditional calibration methods require the power of transmission line be cut off, which results in complicated operation and power off loss. This paper proposes an online calibration system which can calibrate electronic current transformers without power off. In this work, the high accuracy standard current transformer and online operation method are the key techniques. Based on the clamp-shape iron-core coil and clamp-shape air-core coil, a combined clamp-shape coil is designed as the standard current transformer. By analyzing the output characteristics of the two coils, the combined clamp-shape coil can achieve verification of the accuracy. So the accuracy of the online calibration system can be guaranteed. Moreover, by employing the earth potential working method and using two insulating rods to connect the combined clamp-shape coil to the high voltage bus, the operation becomes simple and safe. Tests in China National Center for High Voltage Measurement and field experiments show that the proposed system has a high accuracy of up to 0.05 class.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online tuning of impedance matching circuit for long pulse inductively coupled plasma source operation—An alternate approach

Impedance matching circuit between radio frequency (RF) generator and the plasma load, placed between them, determines the RF power transfer from RF generator to the plasma load. The impedance of plasma load depends on the plasma parameters through skin depth and plasma conductivity or resistivity. Therefore, for long pulse operation of inductively coupled plasmas, particularly for high power (∼100 kW or more) where plasma load condition may vary due to different reasons (e.g., pressure, power, and thermal), online tuning of impedance matching circuit is necessary through feedback. In fusion grade ion source operation, such online methodology through feedback is not present but offline remote tuning by adjusting the matching circuit capacitors and tuning the driving frequency of the RF generator between the ion source operation pulses is envisaged. The present model is an approach for remote impedance tuning methodology for long pulse operation and corresponding online impedance matching algorithm based on RF coil antenna current measurement or coil antenna calorimetric measurement may be useful in this regard.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Online monitoring of oil film using electrical capacitance tomography and level set method

In the application of oil-air lubrication system, electrical capacitance tomography (ECT) provides a promising way for monitoring oil film in the pipelines by reconstructing cross sectional oil distributions in real time. While in the case of small diameter pipe and thin oil film, the thickness of the oil film is hard to be observed visually since the interface of oil and air is not obvious in the reconstructed images. And the existence of artifacts in the reconstructions has seriously influenced the effectiveness of image segmentation techniques such as level set method. Besides, level set method is also unavailable for online monitoring due to its low computation speed. To address these problems, a modified level set method is developed: a distance regularized level set evolution formulation is extended to image two-phase flow online using an ECT system, a narrowband image filter is defined to eliminate the influence of artifacts, and considering the continuity of the oil distribution variation, the detected oil-air interface of a former image can be used as the initial contour for the detection of the subsequent frame; thus, the propagation from the initial contour to the boundary can be greatly accelerated, making it possible for real time tracking. To testify the feasibility of the proposed method, an oil-air lubrication facility with 4 mm inner diameter pipe is measured in normal operation using an 8-electrode ECT system. Both simulation and experiment results indicate that the modified level set method is capable of visualizing the oil-air interface accurately online.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗