Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “office building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Long-term carbon emission reduction potential of building retrofits with dynamically changing electricity emission factors

Buildings account for approximately 36% of the United States' total carbon emissions and building retrofits have great potential to reduce carbon emissions. Current research adopts a constant electricity emission factor although it changes over time due to the increase of renewable energy generation. Here, to accurately predict emission reduction potential of building retrofits, this study develops a novel method by using dynamically changing electricity emission factors. Using medium office buildings as an example, we predicted emission reduction of eight building retrofit measures from 2020 to 2050 in five locations in the U.S. with distinct climates and renewable adoption rates. To evaluate emission reduction potential sensitivity to the compositions of electricity generation, five scenarios for renewable energy adoptions are investigated. The results reveal several new phenomena on emission reduction potential of building retrofits for medium offices in the U.S.: (1) it decreases from 2026 to 2050; (2) it has the same trend with coal usage; and (3) it reaches the maximum under the high renewable cost scenario. Based on the results, it is recommended that building retrofits should focus on 1) improving lighting and equipment efficiency; 2) locations with higher coal usage rate, and 3) buildings under the high renewable cost scenario. The new method can also be used for predicting emission reduction potential of the building sector in the U.S. by applying to other building types and regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An assessment of power flexibility from commercial building cooling systems in the United States

Understanding varying characteristics and aggregate potential of power flexibility from different building types considering regional diversity is critically important to actively engaging building resources in future eco-friendly, low-cost, and sustainable power systems. This paper presents a comprehensive characteristics analysis and potential assessment of the power flexibility from heating, ventilation, and air conditioning (HVAC) loads in commercial buildings in the U.S. using a simulation-based method. In this method, commercial buildings are first grouped by building types and climate regions. The U.S. Department of Energy Commercial Prototype Building Models are used to represent an average building in each group and are simulated to characterize corresponding power flexibility. Based on building survey data, the number of commercial buildings in each group is estimated and used to calculate aggregate power flexibility. It is found that HVAC loads in commercial buildings offer more flexibility for increasing power consumption than for decreasing it. The power consumption of commercial buildings in the U.S. can be increased by 46 GW and decreased by 40 GW on peak summer days. Among all commercial building types, standalone retail buildings provide the most absolute flexibility while the medium office buildings have the most flexibility as a percentage of the rated power consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Factors Influencing Building Demand Flexibility

The U.S. Department of Energy’s National Roadmap for Grid-interactive Efficient Buildings (GEB) acknowledged that building demand flexibility (DF) is both an important strategy to decarbonizing the buildings sector and an important resource for meeting the changing needs of the electrical grid such as improving grid reliability. However, understanding the complexity and uncertainties in real building field performance of DF strategies is a large gap hindering stakeholders on both grid and buildings side to make investments on deploying such strategies. The research work in this report intended to advance understanding of the variability and influential factors in building demand flexibility. Adding such knowledge based on lab testing results and measured performance data from real buildings is an important contribution. The report uses standardized metrics and methods to quantify DF performance from field-measured DF datasets of two significant building groups of big-box retail and medium office buildings to present the challenge of building DF variability in multiple dimensions. The report presents findings related to how several key factors influence building demand flexibility from implementing a common, cost-effective DF control strategy (i.e., adjusting zone temperatures). The findings are supported by full-scale lab testing, field data analysis and simulation research. The authors also provided application-oriented recommendations to stakeholders such as building aggregators, utility program design professionals, sophisticated building portfolio owners, and more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating Health and Energy Efficiency in Multi-Family Buildings

The intersection between health and the built environment has long been known. Since the 18 th century, public health officials have been targeting building issues, such as crowding, poor sanitation, and inadequate ventilation in efforts to reduce infectious diseases and fire hazards. More recently, federal agencies, such as the U.S. Environmental Protection Agency (EPA), the Centers for Disease Control and Prevention, HUD, and the DOE have been working to reduce or eliminate indoor building factors that are known to have adverse health impacts on Americans, including reducing lead in housing and indoor air pollution that causes respiratory disease, and ensuring access to adequate heating, cooling, and moisture control. PNNL, in support of FEMP’s HBI, undertook a review of literature and existing best practices to identify current activities and research on the intersection between traditional energy-efficiency measures and occupant health within multi-family buildings. While the HBI methodology has focused on traditional office building spaces, it is now expanding into additional building use types. This overview explores some of the most impactful resources to help property owners and managers understand more about multi-family residential buildings that are both healthy and energy efficient. The federal government provides direct oversight and operation across several types of multi-family residential housing, including dormitories, barracks, and senior community living centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Fidelity Building Emulator

This dataset provides high-fidelity time series data for an emulated commercial office building sited in the Chicago, IL area during a Typical Meteorological Year (TMY). This dataset consists of air-side HVAC measurements and control inputs, and it includes normal operations as well as various implemented faults (with associated ground truth measurements) implemented on selected days. This data could be used to quantify and compare the impacts of different faults, and it could also be used as training or validation data for machine learning algorithms (e.g., reduced-order modelling, fault detection and diagnosis).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automatic and rapid calibration of urban building energy models by learning from energy performance database

Urban building energy modeling (UBEM) is attracting increasing attention in the energy modeling filed. Unlike modeling a single building using detailed building systems information, UBEM generally uses limited high-level building stock data to infer default assumptions about building characteristics and operations. Additionally, this practice inherently brings uncertainty to UBEM. This study introduced a novel method of automatic and rapid calibration of UBEM based on the annual electricity and natural gas energy use data by learning the correlations between crucial model input parameters and the building energy use from the reference building models. A case study was presented to calibrate 72 large office buildings built before 1978 in San Francisco. Seventeen model parameters were selected and Monte Carlo sampling was used to create 1000 samples that reasonably represent the parameter space. Then 1000 simulations were performed for the reference building model to create an energy performance database. The results showed that by learning from the energy performance database, it took less than four simulation runs on average to calibrate a building model. After the calibration, the distributions of each parameter were obtained to replace their single predefined default values. For example, the default lighting power density of 21.39 W/m 2 was calibrated to be 7.50 W/m 2 on average. The case study successfully demonstrated the effectiveness of the novel calibration method for UBEM in the mild climate. The method will be further tested in future for other climate zones and other building types.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An analysis of the hybrid internal mass modeling approach in EnergyPlus

Accurate simulation of building system dynamics is particularly important for understanding building energy flexibility. Among all dynamics in a building, a zone temperature’s variation is especially important, as it significantly affects a building’s electricity load profile when its heating, ventilating, and air conditioning (HVAC) system is controlled with on/off cycles or setpoint reset strategies. To accurately simulate a zone temperature’s dynamics, internal mass needs to be modeled carefully. In this paper, we compare the two internal mass modeling approaches provided by EnergyPlus, i.e., internal mass object and zone air capacitance multiplier, to better understand their impacts on zone temperature simulation. Real building zone temperature dynamic data from small- and medium-sized office buildings are analyzed and compared with simulated data. In particular, we illustrate the effectiveness of a hybrid method of the two EnergyPlus modeling approaches, which yields more realistic zone temperature dynamics, especially when the zone is conditioned with heat pump systems with on/off cycling.

Chen, Zhelun↗

Urban microclimate and its impact on building performance: A case study of San Francisco

Urban microclimate exerts an increasing influence on urban buildings, energy, and sustainability. This study uses 10-year measured hourly weather data at 27 sites in San Francisco, California, to (1) analyze and visualize the urban microclimate patterns and urban heat island effect; (2) simulate annual energy use and peak electricity demand of typical large office buildings and large hotels to investigate the influence of urban microclimate on building performance; (3) simulate indoor air temperature of a single-family house without air-conditioning during the record three-day heatwave of 2017, to quantify the divergence of climate resilience due to urban microclimate effect. Results show significant microclimate effects in San Francisco with up to 11 °C outdoor air temperature difference between the coastal and downtown areas on September 1, 2017, during the record three-day heatwave. The simulated energy results of the prototype large office and large hotel buildings using the 2017 weather data show over 100% difference in annual heating energy use and 65% difference in annual cooling energy use across different stations; as well as up to 30% difference in peak cooling electricity demand. The impacts on annual site or source energy use are minimal (less than 5%) as cooling and heating in a mild climate are a relatively small portion of overall building energy use in San Francisco. Results also show the microclimate effects influence indoor air temperature of unconditioned homes by up to 5 °C. Newer buildings and homes are much less affected by microclimate effects due to more stringent performance requirements of the building envelope and energy systems. Furthermore, these findings inform that San Francisco microclimate variations should be considered in urban energy planning, building energy codes and standards, as well as heat resilience policymaking.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

When Do Efficiency and Demand Flexibility Go Hand-in-hand?

Utilities have been experimenting with integrated demand side management (IDSM) programs since the 2000s. The potential benefits of improved program cost-effectiveness and customer engagement from combining energy efficiency (EE), demand flexibility (DF), and other distributed energy resources into an integrated customer offering have been recognized although there are several known regulatory and program administrative challenges. In addition, as buildings adopt EE measures, the baseline load profile change generally reduces the potential load that can be shed or shifted. This has been a significant technical barrier for customers and program implementers. However, it is a myth that EE always reduces DF. Load change from EE can be time-varying. Therefore, whether EE improves or reduces DF should be evaluated on an individual measure basis accounting for weather dependencies and interactions. For IDSM program design purpose, it is useful to understand how common EE features influence DF and the underlying building physics. In this paper, we use parametric simulations of a prototype medium office building to evaluate how various EE features influence DF, measured by a “demand decrease intensity” (W/ft2) metric. These EE features cover envelope characteristics, internal loads, and airside HVAC system. The parametric analysis shows that some efficient HVAC control measures will increase DF but not the traditional building envelope, lighting, and ventilation-related efficiency measures. These findings contribute to the technical basis for achieving enhanced energy benefits by packaging appropriate HVAC control measures in IDSM program design. Program developers should further validate these results in targeted pilot projects.

Yu, Lili↗

Air Return Strategies and Airborne SARS-CoV-2

Dedicated ducted air return per zone for heating, ventilating, and air-conditioning (HVAC) systems is sometimes claimed to be a superior technique over plenum return strategy from the viewpoint of exposure reduction to airborne pathogens. While both the return strategies have advantages, there is limited evidence in the literature as to which strategy is superior merely from a standpoint of building vulnerability to airborne contaminants. We performed multizonal airborne contaminant dispersion modelling using CONTAM to simulate the overall building vulnerability to airborne SARS-CoV-2 aerosols when released in an office building and evaluated the two air return strategies. Results showed that for ducted returns, maintaining negative pressure in the release zone coupled with 100% outdoor air supply can greatly reduce overall building vulnerability. However, for a building maintained under a slight positive pressure and a recirculated air percentage as low as 31%, ducted returns do not necessarily outperform plenum returns in terms of overall building vulnerability to airborne pathogens. Building-specific details and factors that are not easily represented with multizone modelling are important, making general preferential statements for either strategy difficult to make. Insights from this study can guide new construction and retrofits of buildings both during and after the COVID-19 pandemic with the aim of safe re-occupancy of buildings while keeping the buildings resilient against potential future epidemics spread by airborne agents.

Shrestha, Prateek↗

The NASA Langley building solar project and the supporting Lewis solar technology program

The use of solar energy to heat and cool a new office building that is now under construction is reported. Planned for completion in December 1975, the 53,000 square foot, single story building will utilize 15,000 square feet of various types of solar collectors in a test bed to provide nearly all of the heating demand and over half of the air conditioning demand. Drawing on its space-program-developed skills and resources in heat transfer, materials, and systems studies, NASA-Lewis will provide technology support for the Langley building project. A solar energy technology program underway at Lewis includes solar collector testing in an indoor solar simulator facility and in an outdoor test facility, property measurements of solar panel coatings, and operation of a laboratory-scale solar model system test facility. Based on results obtained in this program, NASA-Lewis will select and procure the solar collectors for the Langley test bed.

Ragsdale, R. G.↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

High Efficiency Heat Pumps Can Pave the Path for Building Decarbonization in Cold Climates: Preprint

Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.

cold climate heat pump↗

Intersecting heuristic adaptive strategies, building design and energy saving intentions when facing discomfort environment: A cross-country analysis

Occupants' adaptive strategies play an important role in the energy consumption of office buildings. Previous research has mostly focused on the adaptive strategies triggered by occupants' indoor discomfort; however, it is crucial to understand if specific adaptive strategies are linked to occupants' energy-saving intentions. This study explores the relationships among employees’ heuristic decision-making in their first choice of adaptive strategies (technological solutions or personal adjustments) when facing extreme discomfort conditions, and their energy-saving intentions, then links these patterns with building design, workplace contextual factors, and demographics. A cross-sectional survey was collected among university employees from China, Brazil, Italy, Poland, Switzerland, and the US. Our results demonstrated that the accessibility to indoor environmental controls (IECs) and office type are the significant factors for adaptive strategies. There was a positive relationship between the number of IEC features and the percentage of employees choosing a technological solution. When feeling too hot, occupants in private offices are more likely to adopt a technological solution, whereas occupants in cubicles are more likely to choose a personal adjustment. Occupants with energy-saving intentions are less likely to choose thermostat adjustments or use portable devices as adaptive strategies than their counterparts. Lastly, the cluster analysis suggests females were more likely to use adaptive strategies for energy-saving purposes than males. The majority of occupants would turn on/off lighting to save energy. The study provides the contributions in the connection between the heuristic decision-making process and energy-saving intentions and recommendations on design strategies for building architects, engineers, and managers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benchmarking Demand Flexibility in Commercial Buildings and Flattening the Duck – Addressing Baseline and Commissioning Challenges

With the transition from our traditional electric grid to a cleaner grid with renewable power generation, there is a need to enable building loads to be flexible. Load shedding and shifting will be essential for flattening the “Duck” for decarbonization. This paper explored the trend in the timing of DR events as a reflection of the grid’s needs using recent four years of event data from 203 retail stores in 11 states. The events are becoming significantly shorter with 2-hour duration being the most popular; shifting to late afternoon and early evening is another trend beyond California. Benchmarking will be essential for accounting DF as a reliable grid resource. This paper addresses a challenging aspect of benchmarking – inaccuracies in counterfactual baseline methods can introduce significant DF metrics variations in addition to weather and building characteristics related factors. The conventional “10/10” with adjustment baseline method has inherent limitation by design for load shifting applications. Therefore, it is imperative to identify alternative methods. This study compared three hourly regression baseline methods with “10/10” methods using two groups of commercial buildings that participated in DR programs: (1) 121 big-box retail stores, and (2) 11 office buildings in CA. The 14-day hourly outdoor temperature regression method was found to produce least error in the tested datasets and is promising for load shifting. The paper also pointed out that commissioning issues can also be a significant barrier for achieving consistent DF performance, which building managers and utilities should be aware of.

Liu, Jingjing↗

Realistic Estimation of CO2 Emission Reductions Due to Building Retrofit

Constant CO2 emission factors of electricity are often used to study the emissions of buildings. However, in the era of increased renewable energy for power generation, emission factors of electricity are dynamically changing. This study is to investigate the impact of dynamic CO2 emission factors, which are more realistic than constant ones, on the emission reductions due to building retrofits. The results reveal that if dynamic CO2 emission factors are used for U.S. medium office buildings, improving the efficiency of lighting or electric equipment will lead to more emission reductions in locations with high wind power penetration (e.g., 12% more reductions in Rochester) and fewer reductions in locations with high solar power penetration (e.g., 8% fewer reductions in San Diego). As for improving envelope insulation, dynamic CO2 emission factors have more impact on the emission reductions in hot climates than in cold climates.

Lou, Yingli↗