Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear recoils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Measurements of the ionization efficiency of protons in methane

The amount of energy released by a nuclear recoil ionizing the atoms of the active volume of detection appears “quenched” compared to an electron of the same kinetic energy. This different behavior in ionization between electrons and nuclei is described by the Ionization Quenching Factor (IQF) and it plays a crucial role in direct dark matter searches. For low kinetic energies (below 50 keV ), IQF measurements deviate significantly from common models used for theoretical predictions and simulations. We report measurements of the IQF for proton, an appropriate target for searches of Dark Matter candidates with a mass of approximately 1 GeV , with kinetic energies in between 2 keV and 13 keV in 100 mbar of methane. We used the Comimac facility in order to produce the motion of nuclei and electrons of controlled kinetic energy in the active volume, and a NEWS-G SPC to measure the deposited energy. The Comimac electrons are used as a reference to calibrate the detector with 7 energy points. A detailed study of systematic effects led to the final results well fitted by IQF (E K )=E$^α_K$ / (β+E$^α_K$) with α=0.70±0.08 and β=1.32±0.17 . In agreement with some previous works in other gas mixtures, we measured less ionization energy than predicted from SRIM simulations, the difference reaching 33% at 2 keV .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First demonstration of 30 eVee ionization energy resolution with RICOCHET germanium cryogenic bolometers

The future RICOCHET experiment aims to search for new physics in the electroweak sector by measuring the Coherent Elastic Neutrino-Nucleus Scattering process from reactor antineutrinos with high precision down to the sub-100 eV nuclear recoil energy range. While the RICOCHET collaboration is currently building the experimental setup at the reactor site, it is also finalizing the cryogenic detector arrays that will be integrated into the cryostat at the Institut Laue Langevin in early 2024. In this paper, we report on recent progress from the Ge cryogenic detector technology, called the CryoCube. More specifically, we present the first demonstration of a 30 eVee (electron equivalent) baseline ionization resolution (RMS) achieved with an early design of the detector assembly and its dedicated High Electron Mobility Transistor (HEMT) based front-end electronics with a total input capacitance of about 40 pF. This represents an order of magnitude improvement over the best ionization resolutions obtained on similar phonon-and-ionization germanium cryogenic detectors from the EDELWEISS and SuperCDMS dark matter experiments, and a factor of three improvement compared to the first fully-cryogenic HEMT-based preamplifier coupled to a CDMS-II germanium detector with a total input capacitance of 250 pF. Additionally, we discuss the implications of these results in the context of the future RICOCHET experiment and its expected background mitigation performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark Matter Candidates of a Very Low Mass

We review dark matter (DM) candidates of a very low mass appearing in the window below the traditional weakly interacting massive particle (m χ ≲ 10 GeV) and extending down to m χ ≳ 1 meV, somewhat below the mass limit at which DM becomes wavelike. Such candidates are motivated by hidden sectors such as hidden valleys, which feature hidden forces and rich dynamics, but have evaded traditional accelerator searches for New Physics because of their relatively weak coupling to the Standard Model (SM). Such sectors can still be detected through dedicated low-energy colliders, which, through their intense beams, can have sensitivity to smaller couplings, or through astrophysical observations of the evolution of DM halos and stellar structures, which, through the Universe's epochs, can be sensitive to small DM interactions. We also consider mechanisms whereby the DM abundance is fixed through the interaction with the SM, which directly motivates the search for light DM in terrestrial experiments. The bulk of this review is dedicated to the new ideas that have been proposed for direct detection of such DM candidates of a low mass through nuclear recoils, electronic excitations, or collective modes such as phonons and magnons. The rich tapestry of materials and modes in the condensed matter landscape is reviewed along with specific prospects for detection.

Physics↗

Dark matter searches and energy accumulation and release in materials

Efforts to identify dark matter by detecting nuclear recoils produced by dark matter particles reveal low-energy backgrounds of unknown origin in different types of detectors. In many cases, energy accumulation and delayed burst-like releases of stored energy could provide an explanation. These dynamics follow Prigogine’s ideas on systems with energy flow and the general Self-Organized Criticality scenario. We compare these models with properties of excess backgrounds in cryogenic solid-state detectors, relaxation processes in glasses and crystals, our observations of delayed luminescence in NaI(Tl), and make predictions for more phenomena present in these systems and in superconducting photon detectors and qubits. Experiments to create accurate phenomenological models are needed.

Pereverzev, Sergey↗

New Laboratory and Astrophysical Probes of Physics Beyond the Standard Model (Final Technical Report)

The first of these directions centers on new ideas in dark matter detection. As experimental scrutiny narrows the window for new physics at the weak scale, it has become apparent that the solution to the dark matter mystery may not reside there. Theoretical developments such as the hidden sector/valley paradigm have, at the same time, shown that compelling theories of dark matter reside below the weak scale. Searching for dark matter at lower mass scales requires looking beyond the current paradigm of dark matter direct detection based on nuclear recoils. It is the goal of this project to provide new ideas to guide the experimental program looking for light dark matter. I am actively proposing ideas for detecting dark matter as light as a meV, well beyond the current focus of GeV-TeV scale dark matter. Some of the ideas I have proposed, such as superconducting, superfluid, and polar material targets, are actively being developed into experiments. My group will provide the relevant calculations to determine dark matter reach, providing crucial input to experiment on which targets should be developed. We will also provide an effective field theory framework to understand which types of experiments are most sensitive to each interaction type. The second of these directions is on probes of dark matter substructure as a mean to constrain, or observe, models of dark matter. The standard ΛCDM paradigm assumes that the dark matter density perturbations are adiabatic, scale invariant, and produced during inflation. However, many standard models of dark matter will produce modifications of this prediction, such as axion models with symmetry broken below the inflationary scale. Remarkably, we have limited direct measurements of the dark matter clumpiness at mass scales below dwarf galaxies. This allows for the possibility of observing modifications from vanilla ΛCDM due to particle dynamics. In many cases, simulations of dark matter structure in the presence of non-scale invariant fluctu- ations are understudied or completely lacking. I plan to develop both theoretical predictions for small scale structure in models with additional matter power on small scales, as well as observa- tional probes of small scale halos or clumps. One idea I have been recently focused on is pulsar timing, though my group will pursue a variety of lensing and astrometric probes. Lastly, the most risky direction involves spacetime fluctuations from quantum gravity. I showed that if one assumes that metric fluctuations in the Minkowski vacuum, at a surface separating a region in and out of causal contact (which we call a “horizon”), are determined by standard thermodynamic considerations at horizon, these metric fluctuations are large enough to observe in an interferometer with similar sensitivity to LIGO. In a follow-up paper we showed that these assumption holds for the vacuum in AdS/CFT. In future work, I plan to connect this work to recent soft graviton results, to frame this work in a concrete Randall-Sundrum model, and to work out concrete phenomenological predictions from the model. This work unquestionably takes a less trodden path, and works well as part of a well-rounded portfolio of less and more risky ideas. Particle physics is currently at a juncture which requires bold exploration of qualitatively new directions. This proposal outlines some of my plans over the coming years in these directions, leaving room also for surprises.

79 ASTRONOMY AND ASTROPHYSICS↗

Hunting Sub-GeV Dark Matter with Diamonds and Magnetic Microcalorimeters Principle

This project is to study feasibility of a new concept for the sub-GeV dark matter (DM) detection using diamond crystals and magnetic microcalorimeters (MMCs). Diamond crystals are made of low mass carbon constituent that maximize kinetic energy of nuclear recoils from sub-GeV DM scattering due to their relatively similar masses. MMC is employed as a sensitive phonon sensor to measure athermal phonons that are produced by DM scattering in diamond crystals with 100 ns timing resolution and ~10 eV energy resolution. MMC’s fast timing resolution allows high precision phonon pulse shape analysis to separate out unwanted background or noise signals in the low energy region at E < 1 keV. Especially, the low energy excess (LEE) problems have been reported in the dark matter detection community and the proposed diamond-MMC detector might be able to provide important information to understand the origins of LEE signals in DM detectors. In this project a diamond-MMC detector has been built for proof-of-concept experiments and athermal phonon collection efficiencies have been investigated for single crystal and poly-crystal chemical-vapour-diamonds (SC and PC CVDs) as well as reference sapphire crystals are tested in the same geometries to quatify athermal phonon propagation and their collection to the MMC phonon sensors. Athermal phonon collection efficiencies and their lifetime in the diamond and sapphire crystals are successfully measured in the same geometry and experimental setup for comparison. SC CVD crystals exhibit poorer performance than the sapphire reference crystals in athermal phonon collection, while the PC CVD crystal exhibit better result than the sapphire. PC CVD with MMC phonon sensors would be feasible for sub GeV DM detection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

LArCADe | Liquid Argon Charge Amplification Devices

The Liquid Argon Charge Amplification Devices (LArCADe) project is an R$\&$D effort aimed at developing instrumentation capable of lowering detection thresholds for ionization signatures in liquid and gaseous argon detectors and achieving O(100 $\mu$m) position resolution. The core concept is the use of sharp “tip arrays” that generate strong local electric-field enhancement, enabling charge amplification and collection with improved spatial resolution. A key physics motivation for this work is to enhance the experimental sensitivity of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) measurements to low-energy nuclear recoils by enabling spatially resolved charge reconstruction at reduced ionization thresholds, with the goal of achieving event-by-event energy reconstruction for interactions originating from localized accelerator or astrophysical neutrino sources. This poster will present the current status of the instrumentation R$\&$D, which leverages Fermilab’s Noble Liquid Test Facility and UC Santa Barbara’s Nanofabrication Facility, and will discuss the potential physics impact of this technology.

Antonakis, Alexander [UC, Santa Barbara]↗

Energy and chemical reaction. I

Reagent translational energy effect on dynamics of ionic and atomic reactions, using nuclear recoil and chemical accelerator methods

Wolfgang, R.↗

Astrogam - A magnetic rigidity spectrometer for gamma-ray astronomy

A novel concept is presented for a high-energy gamma-ray telescope with an extended energy range and excellent energy and angular resolution. The characteristics of Astrogam, a wide-field camera which makes an all-sky survey, are enumerated. Consideration is given to the instrument's unique features: wide energy range (four orders of magnitude and energy, which will bridge the gap between satellite and ground-based observations); excellent source location precision (multiple scattering error dominating nuclear recoil and measurement error below 20 GeV); and excellent energy resolution (1-percent energy resolution). Astrogam will make observations in the GTE energy range possible and could resolve complex source regions like the Crab pulsar/Nebular system, the Galactic center, and the Geminga region as well as discover the true nature of the sources.

Adams, James H., Jr.↗

Results on low-mass weakly interacting massive particles from a 11 kg-day target exposure of DAMIC at SNOLAB

We present constraints on the existence of weakly interacting massive particles (WIMPs) from a 11 kg-day target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies $>$200 eV$_{\rm ee}$ in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An excess of ionization events is observed above the analysis threshold of 50 eV$_{\rm ee}$. While the origin of this low-energy excess requires further investigation, our data exclude spin-independent WIMP-nucleon scattering cross sections $\sigma_{\chi-n}$ as low as $3\times 10^{-41}$ cm$^2$ for WIMPs with masses $m_{\chi}$ from 7 to 10 GeV$c^{-2}$ . These results are the strongest constraints from a silicon target on the existence of WIMPs with $m_{\chi}$$<$9 GeV$c^{-2}$ and are directly relevant to any dark matter interpretation of the excess of nuclear-recoil events observed by the CDMS silicon experiment in 2013.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for inelastic dark matter-nucleus scattering with the PICO-60 CF$_{3}$I and C$_{3}$F$_{8}$ bubble chambers

PICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear recoil energy detection window from a few keV to $O$(100 keV) or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been developed. This study reports the results of a search for dark matter inelastic scattering with the PICO-60 bubble chambers. The analysis reported here comprises physics runs from PICO-60 bubble chambers using CF$_{3}$I and C$_{3}$F$_{8}$. The CF$_{3}$I run consisted of 36.8 kg of CF$_{3}$I reaching an exposure of 3415 kg-day operating at thermodynamic thresholds between 7 and 20 keV. The C$_{3}$F$_{8}$ runs consisted of 52 kg of C$_{3}$F$_{8}$ reaching exposures of 1404 kg-day and 1167 kg-day running at thermodynamic thresholds of 2.45 keV and 3.29 keV, respectively. The analysis disfavors various scenarios, in a wide region of parameter space, that provide a feasible explanation of the signal observed by DAMA, assuming an inelastic interaction, considering that the PICO CF$_{3}$I bubble chamber used iodine as the target material.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterizing Al quasiparticle diffusion using a positionable laser (Final Technical Report)

This Career Award accomplished most of its goals, in demonstrating for the first time a low- threshold nuclear recoil detector based on the quantum evaporation of helium-4. Through this work, we trained several PhD students and evolved this niche R&D topic into a central pillar of the DOE-funded TESSERACT project, which now plans to take underground helium data in 2028.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SECAR: A recoil separator for nuclear astrophysics

Proton-and alpha-capture reactions on unstable proton-rich nuclei power astrophysical explosions like novae and X-ray bursts. Direct measurements of these reactions are crucial for understanding the mechanisms behind these explosions and the nucleosynthesis at such sites. The recoil mass separator, SECAR (SEparator for CApture Reactions) at the National Superconducting Cyclotron Laboratory (NSCL) and the Facility for Rare Isotope Beams (FRIB), has been designed with the required sensitivity to study (p,γ) and (α,γ) reactions, directly at astrophysical energies in inverse kinematics, with radioactive beams of masses up to about A = 65. The complete SECAR system, including two Wien Filters for high mass resolution, has been installed at Michigan State University and is currently being commissioned. The present article introduces the SECAR concept, its scientific goals, and provides an update of the current status of the project.

Tsintari, P↗

AGNs on the Move: A Search for Off-nuclear AGNs from Recoiling Supermassive Black Holes and Ongoing Galaxy Mergers with the Zwicky Transient Facility

A supermassive black hole (SMBH) ejected from the potential well of its host galaxy via gravitational wave recoil carries important information about the mass ratio and spin alignment of the pre-merger SMBH binary. Such a recoiling SMBH may be detectable as an active galactic nucleus (AGN) broad-line region offset by up to 10 kpc from a disturbed host galaxy. We describe a novel methodology using forward modeling with The Tractor to search for such offset AGNs in a sample of 5493 optically variable AGNs detected with the Zwicky Transient Facility (ZTF). We present the discovery of nine AGNs that may be spatially offset from their host galaxies and are candidates for recoiling SMBHs. Five of these offset AGNs exhibit double-peaked broad Balmer lines, which may have arisen from unobscured accretion disk emission, and four show radio emission indicative of a relativistic jet. The fraction of double-peaked emitters in our spatially offset AGN sample is significantly larger than the 16% double-peaked emitter fraction observed for ZTF AGNs overall. In our sample of variable AGNs we also identified 52 merging galaxies, including a new spectroscopically confirmed dual AGN. Finally, we detected the dramatic rebrightening of SDSS 1133, a previously discovered variable object and recoiling SMBH candidate, in ZTF. The flare was accompanied by the reemergence of strong P Cygni line features, indicating that SDSS 1133 may be an outbursting luminous blue variable star.

79 ASTRONOMY AND ASTROPHYSICS↗

Non-standard neutrino interactions in light mediator models at reactor experiments

Compared to other neutrino sources, the huge anti-neutrino fluxes at nuclear reactor based experiments empower us to derive stronger bounds on non-standard interactions of neutrinos with electrons mediated by light scalar/vector mediators. At neutrino energy around 200 keV reactor anti-neutrino flux is at least an order of magnitude larger compared to the solar flux. The atomic and crystal form factors of the detector materials related to the details of the atomic structure becomes relevant at this energy scale as the momentum transfers would be small. Non-standard neutrino-electron interaction mediated by light scalar/vector mediator arises naturally in many low-scale models. We also propose one such new model with a light scalar mediator. Here, we investigate the parameter space of such low-scale models in reactor based neutrino experiments with low threshold Ge and Si detectors, and find the prospect of probing/ruling out the relevant parameter space by finding the projected sensitivity at 90% confidence level by performing a $χ$ 2 -analysis. We find that a detector capable of discriminating between electron recoil and nuclear recoil signal down to a very low threshold such as 5 eV placed in reactor based experiment would be able to probe a larger region in parameter space compared to the previously explored region. A Ge (Si) detector with 10 kg-yr exposure and 1 MW reactor anti-neutrino flux would be able to probe the scalar and vector mediators with masses below 1 keV for coupling products $\sqrt{g_vg_e}$ ~ 1 × 10 -6 (9.5 × 10 -7 ) and 1 × 10 -7 (8 × 10 -8 ), respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear Microprobe using Elastic Recoil Detection (ERD) for Hydrogen Profiling in High Temperature Protonic Conductors

The interaction between hydrogen and various high temperature protonic conductors (HTPC) has not been clearly understood due to poor densification and unreacted secondary phases. the melt-processing technique is used in producing fully dense simple SrCe(0.9)Y (0.10) O(3-delta) and complex Sr3Ca(1+x)Nb(2+x)O(9-delta) perovskites that can not be achieved by solid-state sintering. the possibilities of ion beam analysis have been investigated to quantify hydrogen distribution in HTPC perovskites subjected to water heat treatment. Nuclear microprobe technique is based on the interactions of a focused ion beam of MeV light ions (H-1, H-2, He-3, He-4,.) with the sample to be analyzed to determine local elemental concentrations at the cubic micrometer scale, the elastic recoil detection analysis technique (ERDA) has been carried out using He-4(+) microbeams and detecting the resulting recoil protons. Mappings of longitudinal sections of water treated SrCeO3 and Sr(Ca(1/3)Nb(2/3))O3 perovskites have been achieved, the water treatment strongly alters the surface of simple SrCe(0.9)Y(0.10)O(3-delta) perovskite. From Rutherford Back Scattering measurements (RBS), both Ce depletion and surface re-deposition is evidenced. the ERDA investigations on water treated Sr3Ca(1+x)Nb(2+x)O(9-delta) perovskite did not exhibit any spatial difference for the hydrogen incorporation from the surface to the centre. the amount of hydrogen incorporation for Sr3Ca(1+x)Nb(2+x)O(9-delta) was low and required further development of two less conventional techniques, ERDA in forward geometry and forward elastic diffusion H-1(p,p) H-1 with coincidence detection.

Berger, Pascal↗

Development of the multi-purpose Cologne Compact Differential Plunger (CoCoDiff) for the measurement of nuclear level lifetimes with the Recoil Distance Doppler-shift method

Here, a new 3-foil plunger device, the Cologne Compact Differential (CoCoDiff) plunger has been built and commissioned. Due to its compact size, it can be used together with many different spectrometers and auxiliary detectors. As a commissioning experiment, level lifetimes of the $2^{+}_{1}$ and the $4^{+}_{1}$ excited states of 50 Cr have been measured, using the Differential Decay Curve method (DDCM). A derivation is given on how this method can be applied to a differential plunger measurement, in order to measure distances for lifetimes from two different regions of sensitivity at the same time. The commissioning experiment took place at the Cologne FN tandem accelerator, using the reaction 24 Mg( 32 S,4p2n) 50 Cr. Lifetimes, deduced from this measurement, agree well with literature values from earlier measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗