Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

SU-E-T-110: Development of An Independent, Monte Carlo, Dose Calculation, Quality Assurance Tool for Clinical Trials

Purpose: To develop a comprehensive end-to-end test for Varian's TrueBeam linear accelerator for head and neck IMRT using a custom phantom designed to utilize multiple dosimetry devices. Purpose: To commission a multiple-source Monte Carlo model of Elekta linear accelerator beams of nominal energies 6MV and 10MV. Methods: A three source, Monte Carlo model of Elekta 6 and 10MV therapeutic x-ray beams was developed. Energy spectra of two photon sources corresponding to primary photons created in the target and scattered photons originating in the linear accelerator head were determined by an optimization process that fit the relative fluence of 0.25 MeV energy bins to the product of Fatigue-Life and Fermi functions to match calculated percent depth dose (PDD) data with that measured in a water tank for a 10x10cm2 field. Off-axis effects were modeled by a 3rd degree polynomial used to describe the off-axis half-value layer as a function of off-axis angle and fitting the off-axis fluence to a piecewise linear function to match calculated dose profiles with measured dose profiles for a 40×40cm2 field. The model was validated by comparing calculated PDDs and dose profiles for field sizes ranging from 3×3cm2 to 30×30cm2 to those obtained from measurements. A benchmarking study compared calculated data to measurements for IMRT plans delivered to anthropomorphic phantoms. Results: Along the central axis of the beam 99.6% and 99.7% of all data passed the 2%/2mm gamma criterion for 6 and 10MV models, respectively. Dose profiles at depths of dmax, through 25cm agreed with measured data for 99.4% and 99.6% of data tested for 6 and 10MV models, respectively. A comparison of calculated dose to film measurement in a head and neck phantom showed an average of 85.3% and 90.5% of pixels passing a 3%/2mm gamma criterion for 6 and 10MV models respectively. Conclusion: A Monte Carlo multiple-source model for Elekta 6 and 10MV therapeutic x-ray beams has been developed as a quality assurance tool for clinical trials.

60 APPLIED LIFE SCIENCES↗

Using multiple data sources to investigate foraging niche partitioning in sympatric obligate avian scavengers

As carrion feeders competing for a limited and ephemeral resource, avian scavengers are ideal model organisms to study mechanisms of niche partitioning. Previous work has focused on observations of species’ interactions at carcasses, and although fruitful, the inclusion of behavior beyond that at carcasses, such as movement patterns, could yield a more comprehensive understanding of mechanisms of foraging niche partitioning. Our goal was to assess how differences in physiological, morphological, and social characteristics between sympatric black vultures ( Coragyps atratus ) and turkey vultures ( Cathartes aura ) manifest interspecific variation in movement patterns, foraging habitats, and carcass use to reduce direct competition. Both species are obligate scavengers that co-occur across much of the New World. Turkey vultures are solitary foragers with enhanced olfactory capabilities and wings optimized for energy-efficient low-altitude soaring. Black vultures are aggressive, heavier bodied, and forage socially. We assessed interspecific variation in carcass exploitation using experimental carcass trials encompassing a range of habitats, carcass sizes, and seasons, and used GPS telemetry to compare how soaring conditions influenced daily space use and diurnal patterns of movement activity for each species. Turkey vultures occurred more often at small (i.e., rabbit) carcasses, and those obscured by forest cover than black vultures, and were the first vultures recorded at 94% of carcasses visited by both species. Both species increased movement rates and daily ranges when soaring conditions were favorable; however, turkey vultures had higher travel rates regardless of soaring conditions. Our results suggest the olfactory sense of turkey vultures allows them to locate smaller and visually obscured carcasses more efficiently than black vultures, facilitated by wing morphology that allows them to forage over large areas efficiently. Socially foraging black vultures appear specialized at locating larger carcasses in open habitats, which does not require as much foraging flight as turkey vultures. Our study illustrates how inclusion of movement ecology into niche partitioning studies provides a more complete understanding of the mechanisms of coexistence in avian scavenger guilds. This approach may provide important information to guide conservation efforts, such as supplemental feeding, of imperiled vulture species.

54 ENVIRONMENTAL SCIENCES↗

State-Space Model to Estimate Salmon Escapement Using Multiple Data Sources

Abstract Accurate estimates of salmonids passing Lower Granite Dam on the Snake River, by species and origin, are a critical input to assessing the status and trends of various populations as well as successful management of fisheries in the Snake River basin. Here, we describe a state-space model that estimates such escapement past a dam by using window counts, PIT tag observations, and data from an adult fish trap, accounting for issues such as nighttime passage, fallback and reascension, potential observation error at the window, and uncertainty in the adult trap rate. We tested the approach using a simulation framework that mimicked several levels of observation error, differences between nighttime passage and reascension rates, and the possibility of the adult trap being closed for some period of time. Our results demonstrate that the model produced unbiased estimates across all tested scenarios. We also applied this model to empirical data from Lower Granite Dam to produce estimates of wild, clipped hatchery, and unclipped hatchery spring/summer-run Chinook Salmon Oncorhynchus tshawytscha and steelhead O. mykiss from spawn years 2010–2019.

See, Kevin E. (ORCID:0000000297626442)↗

Identification of multiple mercury sources to stream sediments near Oak Ridge, TN, USA

In this paper, sediments were analyzed for total Hg concentration (THg) and isotopic composition from streams and rivers in the vicinity of the Y-12 National Security Complex (Y12) in Oak Ridge, TN (USA). In the stream directly draining Y12, where industrial releases of mercury (Hg) have been documented, high THg (3.26 to 60.1 μg/g) sediments had a distinct Hg isotopic composition (δ 202 Hg of 0.02 ± 0.15‰ and Δ 199 Hg of -0.07 ± 0.03‰; mean ± 1SD, n=12) compared to sediments from relatively uncontaminated streams in the region (δ 202 Hg = -1.40 ± 0.06‰ and Δ 199 Hg of –0.26 ± 0.03‰; mean ± 1SD, n=6). Additionally, several streams that are nearby but do not drain Y12 had sediments with intermediate THg (0.06 to 0.21 μg/g) and anomalous δ 202 Hg (as low as -5.07‰). We suggest that the low δ 202 Hg values in these sediments provide evidence for the contribution of an additional Hg source to sediments, possibly derived from atmospheric deposition. In sediments directly downstream of Y12 this third Hg source is not discernible and the Hg isotopic composition can be largely explained by the mixing of low THg sediments with high THg sediments contaminated by Y12 discharges.

54 ENVIRONMENTAL SCIENCES↗

An adaptable multiple power source for mass spectrometry and other scientific instruments

Power supplies are commonly used in the operation of many types of scientific equipment, including mass spectrometers and ancillary instrumentation. A generic modern mass spectrometer comprises an ionization source, such as electrospray ionization (ESI), ion transfer devices such as ion funnels and multipole ion guides, and ion signal detection apparatus. Very often such platforms include, or are interfaced with ancillary elements in order to manipulate samples before or after ionization. In order to operate such scientific instruments, numerous direct current (DC) channels and radio frequency (RF) signals are required, along with other controls such as temperature regulation. In particular, DC voltages in the range of ±400 V, along with MHz range RF signals with peak-to-peak amplitudes in the hundreds of volts range are commonly used to transfer ionized samples under vacuum. Additionally, an ESI source requires a high voltage (HV) DC source capable of producing several thousand volts and heaters capable of generating temperatures up to 300°C. All of these signals must be properly synchronized and managed in order to carry out ion trapping, accumulation and detection.

47 OTHER INSTRUMENTATION↗

Clutchless multiple drive source for output shaft

A first shaft is connected to a source of rotational power and has a gear fixedly mounted on the shaft. A second gear is fixedly mounted on a gear shaft that is parallel to the first shaft. A third gear, also fixedly mounted on gear shaft, meshes with a fourth gear fixedly mounted on the output shaft. The first input shaft and output shaft are rotatably mounted through a housing that is itself rotatable with respect to a support. Both shafts are coaxial and in end-to-end relationship. A second input shaft is connected to a second source of rotational power. A fifth gear, fixedly mounted on second input shaft, meshes with a sixth gear, which is fixedly mounted on rotatable housing and in coaxial relationship with first input shaft. In operation, the first drive source and gear train provide rotational power in a first direction to drive the output shaft in a given direction of rotation. The second source of rotational power may be operated either to decrease the rate of rotation imparted to the output shaft by the first source of rotational power, or to increase that rate of rotation, depending on which direction the housing is rotated by the second source of rotational power.

Webster, L. D.↗

A One-Stop Web Application for the Mars Team

THe Mars Exploration Rover Collaborative Information Portal (MERCIP) provides a window to all mission events. It supports mission updates, data sharing, and collaboration. The report also discusses: Technology spotlight. Integrating data multiple sources. Securing access for multiple clients. A new information infrastructure.

Laufenberg, Lawrence↗

Integrating multiple data sources for malware classification

Disclosed herein are representative embodiments of tools and techniques for classifying programs. According to one exemplary technique, at least one graph representation of at least one dynamic data source of at least one program is generated. Also, at least one graph representation of at least one static data source of the at least one program is generated. Additionally, at least using the at least one graph representation of the at least one dynamic data source and the at least one graph representation of the at least one static data source, the at least one program is classified.

97 MATHEMATICS AND COMPUTING↗

High brightness--multiple beamlets source for patterned X-ray production

Techniques for controllably directing beamlets to a target substrate are disclosed. The beamlets may be either positive ions or electrons. It has been shown that beamlets may be produced with a diameter of 1 .mu.m, with inter-aperture spacings of 12 .mu.m. An array of such beamlets, may be used for maskless lithography. By step-wise movement of the beamlets relative to the target substrate, individual devices may be directly e-beam written. Ion beams may be directly written as well. Due to the high brightness of the beamlets from extraction from a multicusp source, exposure times for lithographic exposure are thought to be minimized. Alternatively, the beamlets may be electrons striking a high Z material for X-ray production, thereafter collimated to provide patterned X-ray exposures such as those used in CAT scans. Such a device may be used for remote detection of explosives.

47 OTHER INSTRUMENTATION↗

Quantitative and three-dimensional assessment of holdup material

Nuclear material deposited in equipment, transfer lines, and ventilation systems of a processing facility is usually referred to as holdup. Operators need to know the location and amount of holdup in their facility for radiation safety and material accountability. In this work, we propose to use an array of detectors co-axial to the inspected pipe to measure the holdup material. This method is implementable into an automated system capable of crawling on surfaces and pipes of various curvatures, which would enable faster, easier, and more accurate holdup safeguards measurements. We first demonstrated that the current holdup assay procedure could lead to a non-negligible bias in the estimate of special nuclear material mass, due to the simplified assumption of deposited geometry introduced by the Generalized Geometry Holdup (GGH) model. The new approach consists of imaging the inner holdup material by characterizing the detector array’s response and unfolding it from the measured light output. Our experimental proof of principle consists of three NaI(Tl) detectors surrounding an aluminum pipe containing two cesium-137 ( 137 Cs) sources. We derived the source distribution inside the pipe by first calculating the detector response matrix using a method adaptive to the surface geometry of the object containing the measured holdup material. Creating a matrix of the detector array’s measured counts, we then proceed to solve an inverse problem, resulting in an accurately located source position and activity distribution within the response matrix’s spatial resolution. Furthermore, we then developed a simulated model of the envisioned experimental setup, which accurately described both the activity and position of the source in 2D. Finally, we extended our model onto a discretized three-dimensional model of the system, encompassing 36 detectors. The model was simulated to measure the source distribution and activity of multiple sources in pipes of varied geometries, which could then be conveniently translated to a real-time holdup measurement protocol. For the 3D simulation of four different source geometries, the model accurately localized the source position in 3D, while the activity retained a maximum relative error of ±5.32%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗