Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “modules”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Intensity Modulated Proton Therapy Versus Intensity Modulated Photon Radiation Therapy for Oropharyngeal Cancer: First Comparative Results of Patient-Reported Outcomes

Purpose: We hypothesized that patients with oropharyngeal cancer treated with intensity modulated proton therapy (IMPT) would have lower symptom burdens, as measured by patient-reported outcome (PRO) surveys, than patients treated with intensity modulated photon therapy (IMRT). Methods and Materials: Patients were treated for oropharyngeal cancer from 2006 to 2015 through prospective registries with concurrent chemotherapy and IMPT or chemotherapy and IMRT and completed the MD Anderson Symptom Inventory for Head and Neck Cancer (MDASI-HN) module at various times before treatment (baseline), during treatment (acute phase), within the first 3 months after treatment (subacute phase), and afterward (chronic phase). Individual symptoms and the top 5 and top 11 most severe symptoms were summarized and compared between the radiation therapy modalities. Results: PRO data were collected and analyzed from 35 patients treated with chemotherapy and IMPT and from 46 treated with chemotherapy and IMRT. The baseline symptom burdens were similar between both groups. The overall top 5 symptoms were food taste problems (mean score 4.91 on a 0-10 scale), dry mouth (4.49), swallowing/chewing difficulties (4.26), lack of appetite (4.08), and fatigue (4.00). Among the top 11 symptoms, changes in taste and appetite during the subacute and chronic phases favored IMPT (all P<.048). No differences in symptom burden were detected between modalities during the acute and chronic phases by top-11 symptom scoring. During the subacute phase, the mean (±standard deviation) top 5 MDASI scores were 5.15 ± 2.66 for IMPT versus 6.58 ± 1.98 for IMRT (P=.013). Conclusions: According to the MDASI-HN, symptom burden was lower among the IMPT patients than among the IMRT patients during the subacute recovery phase after treatment. A prospective randomized clinical trial is underway to define the value of IMPT for the management of head and neck tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced CO 2 Methanation Activity of Sm 0.25 Ce 0.75 O 2-δ –Ni by Modulating the Chelating Agents-to-Metal Cation Ratio and Tuning Metal–Support Interactions

Highly active and selective CO 2 methanation catalysts are critical to CO 2 upgrading, synthetic natural gas production, and CO 2 emission reduction. Wet impregnation is widely used to synthesize oxide-supported metallic nanoparticles as the catalyst for CO 2 methanation. However, as the reagents cannot be homogeneously mixed at an atomic level, it is challenging to modulate the microstructure, crystal structure, chemical composition, and electronic structure of catalysts via wet impregnation. In this work, a scalable and straightforward catalyst fabrication approach has been designed and validated to produce Sm 0.25 Ce 0.75 O 2-δ -supported Ni (SDC–Ni) as the CO 2 methanation catalyst. By varying the chelating agents-to-total metal cations ratio (C/I ratio) during the catalyst synthesis, we can readily and simultaneously modulate the microstructure, metallic surface area, crystal structure, chemical composition, and electronic structure of SDC–Ni, consequently fine-tuning the oxide–support interactions and CO 2 methanation activity. The optimal C/I ratio (0.1) leads to an SDC–Ni catalyst that facilitates C–O bond cleavage and significantly improves CO 2 conversion at 250 °C. A CO 2 -to-CH 4 yield of >73% has been achieved at 250 °C. Furthermore, a stable operation of >1500 hours has been demonstrated, and no degradation is observed. Extensive characterizations were performed to fundamentally understand how to tune and enhance CO 2 methanation activity of SDC–Ni by modulating the C/I ratio. The correlation of physical, chemical, and catalytic properties of SDC–Ni with the C/I ratio is established and thoroughly elaborated in this work. This study could be applied to tune the oxide–support interactions of various catalysts for enhancing the catalytic activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion fluxes and memory effects in an Ar–O 2 modulated radiofrequency-driven atmospheric pressure plasma jet

In this work we used molecular beam mass spectrometry to characterize ion fluxes produced by a modulated radiofrequency (RF)-driven atmospheric pressure plasma jet operating in a homogeneous gas environment (Ar + 1% O 2 ). The influence of the RF modulation frequency (100 Hz to 20 kHz) on the ion fluxes was investigated by time-resolved measurements, and the lifetimes of the dominant ions, O 2 + , NO + , O − , O 2 − and O 3 − , were found to be 28 ± 2, 117 ± 8, 7.3 ± 0.4, 17 ± 1 and 23 ± 2 μs, respectively. The absolute ion densities in the near afterglow region were found to be of the order of 1011 cm−3. Significant differences in the dynamics of the positive and negative ions were found; these are explained by the presence of electrons at similar densities in the afterglow produced by electron detachment reactions from negative ions due to the large concentrations of atomic oxygen and singlet delta oxygen. Transitions in ion flux dynamics for different modulation frequencies and at the startup of the plasma were analyzed together with intensified charge coupled device images recording the plasma propagation in order to assess the dynamics of plasma plume propagation and how it is impacted by ‘memory effects’. Quantitative measurements of the ion densities enabling these memory effects are reported. The results in this paper highlight the tremendous impact of memory effects on plasma propagation and the corresponding pre-ionization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of Irradiance Models for Bifacial PV Modules

We describe and compare two methods for modeling irradiance on the back surface of rack-mounted bifacial PV modules: view factor models and ray-tracing simulations. For each method we formulate one or more models and compare each model with irradiance measurements and short circuit current for a bifacial module mounted a fixed tilt rack with three other similarly sized modules. Our analysis illustrates the computational requirements of the different methods and provides insight into their practical applications. We find a level of consistency among the models which indicates that consistent models may be obtained by parameter calibrations.

14 SOLAR ENERGY↗

Feasibility of a unified approach to intensity-modulated radiation therapy and volume-modulated arc therapy optimization and delivery

Purpose: To study the feasibility of unified intensity-modulated arc therapy (UIMAT) which combines intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) optimization and delivery to produce superior radiation treatment plans, both in terms of dose distribution and efficiency of beam delivery when compared with either VMAT or IMRT alone. Methods: An inverse planning algorithm for UIMAT was prototyped within the PINNACLE treatment planning system (Philips Healthcare). The IMRT and VMAT deliveries are unified within the same arc, with IMRT being delivered at specific gantry angles within the arc. Optimized gantry angles for the IMRT and VMAT phases are assigned automatically by the inverse optimization algorithm. Optimization of the IMRT and VMAT phases is done simultaneously using a direct aperture optimization algorithm. Five treatment plans each for prostate, head and neck, and lung were generated using a unified optimization technique and compared with clinical IMRT or VMAT plans. Delivery verification was performed with an ArcCheck phantom (Sun Nuclear) on a Varian TrueBeam linear accelerator (Varian Medical Systems). Results: In this prototype implementation, the UIMAT plans offered the same target dose coverage while reducing mean doses to organs at risk by 8.4% for head-and-neck cases, 5.7% for lung cases, and 3.5% for prostate cases, compared with the VMAT or IMRT plans. In addition, UIMAT can be delivered with similar efficiency as VMAT. Conclusions: In this proof-of-concept work, a novel radiation therapy optimization and delivery technique that interlaces VMAT or IMRT delivery within the same arc has been demonstrated. Initial results show that unified VMAT/IMRT has the potential to be superior to either standard IMRT or VMAT.

60 APPLIED LIFE SCIENCES↗

SU-F-T-349: Dosimetric Comparison of Three Different Simultaneous Integrated Boost Irradiation Techniques for Multiple Brain Metastases: Intensity-Modulatedradiotherapy, Hybrid Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy

Purpose: To study the dosimetric impact of intensity-modulated radiotherapy (IMRT), hybrid intensity-modulated radiotherapy (h-IMRT) and volumetric modulated arc therapy(VMAT) for whole-brain radiotherapy (WBRT) with simultaneous integrated boost in patients with multiple brain metastases. Methods: Ten patients with multiple brain metastases were included in this analysis. The prescribed dose was 45 Gy to the whole brain (PTVWBRT) and 55 Gy to individual brain metastases (PTVboost) delivered simultaneously in 25 fractions. Three treatment techniques were designed: the 7 equal spaced fields IMRT plan, hybrid IMRT plan and VMAT with two 358°arcs. In hybrid IMRT plan, two fields(90°and 270°) were planned to the whole brain. This was used as a base dose plan. Then 5 fields IMRT plan was optimized based on the two fields plan. The dose distribution in the target, the dose to the organs at risk and total MU in three techniques were compared. Results: For the target dose, conformity and homogeneity in PTV, no statistically differences were observed in the three techniques. For the maximum dose in bilateral lens and the mean dose in bilateral eyes, IMRT and h-IMRT plans showed the highest and lowest value respectively. No statistically significant differences were observed in the dose of optic nerve and brainstem. For the monitor units, IMRT and VMAT plans showed the highest and lowest value respectively. Conclusion: For WBRT with simultaneous integrated boost in patients with multiple brain metastases, hybrid IMRT could reduce the doses to lens and eyes. It is feasible for patients with brain metastases.

60 APPLIED LIFE SCIENCES↗

SU-F-T-503: Trajectory Modulated Arc Therapy of Intracranial Lesions: Development of a Standardized Path-Based Technique for Fully Dynamic Couch-Gantry Modulated Treatments

Purpose: The integration of couch motion during arc delivery is necessitated to enable irradiation trajectories such as coronal arcs, and to enhance the geometrical sampling for dynamic deliveries to the highest extent. To enable such capability, a platform of Trajectory Modulated Arc Therapy (TMAT) is developed in conjunction with standardized noncollisional dynamic path-set for irradiation of intracranial lesions. Methods: A generalized path-set was constructed through the combination of sagittal arcs (45 degrees from the CAX), axial arcs, and coronal arcs produced through modulation of the dynamic rotation of couch. The standardized path was implemented in a contiguous manner enabling the formation of fully automated sub-trajectories to provide maximal geometrical convergence with minimal number of arcs. Progressive sampling technique is used for direct aperture optimization of the MLCs and the selection of couch positions across the control points. Dosimetry of the resulting plans was assessed relative to clinically delivered plans. Using the TrueBeam Developer Mode, plan deliverability was tested. Results: Treatment planning of TMAT sub-trajectories for central, anterior and posterior tumor sites with volumes ranging from 4.75cc to 107cc demonstrated radically reduced doses to the critical OARs when compared to the clinically treated VMAT. Specifically, percentage reduction in mean dose for critical organs such as brainstem, cochlea, and optic nerve are found to be as low as 74±15%, 50±26% and 74±30% respectively as compared to VMAT. Conformity Index, defined as the ratio of tumor volume (VPTV) and 100% dose volume (V(D100%)), was reduced up to 12% while the Gradient Index, defined as V(D100%)/V(D50%), was concurrently improved by up to 14%. Conclusion: An automated standardized trajectory with dynamically modulated couch-gantry arcs has been developed for intracranial radiotherapy. Through the incorporation of coronal arcs, it is demonstrated that significantly reduced OAR doses can be achieved relative to clinically treated patient plans via VMAT. Research Grant Funding Support by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Numerical Codes for the DESC-LSST Analysis Pipeline: Core Cosmology Library Standard Modules and Beyond wCDM Modules (Final Technical Report)

The overall objective of the project is to investigate and develop specific software modules and analysis components for the software pipeline of LSST Dark Energy Science Collaboration (DESC). Following the key projects of DESC Science Roadmap (SRM), we will write and test computer codes for the Core Cosmology Library (CCL) in order to complete its modules, functionalities, and interface to work with the analysis pipelines from the five science probes of DESC (parts of SRM deliverables CX4.2TJP, CX6.2CS). We will also code modules for CCL to test models beyond w-Cold-Dark-Matter (wCDM) and modification to gravity (MG). Interfaces for MG models will also be developed for the TJPCOSMO software which is the main pipeline of the Theory and Joint Probe (TJP) working group (deliverable TJP2.3). In order to use the full power of LSST data to constrain MG models, we will also work on constraints from nonlinear regime by running and analyzing MG N-Body simulations using a Parameterized-Post-Friedmann framework into the Gadget-2 simulation package (deliverable TJP2.2). Preliminary results for the simulations were obtained in the past. In collaboration with other DESC groups, we plan to make these simulations feedable to cosmic emulators that are practical for likelihood analyzes (deliverable TJP2.2, parts of CX6.2CS). We will also modify and integrate our current codes for consistency tests between data sets and probes into the pipeline (parts of deliverables CX8.2TJP, TJP2.3). We understand that other groups will contribute to some of these objectives but our team will focus and collaborate with others on the particular part of testing MG and models beyond wCDM and refine the DESC pipeline for this purpose. PI has been coordinating his work with the TJP and CS working groups and the DESC management team. PI is a full member of DESC since June 2013. He and his students have been contributing to LSST-DESC activities and work including TJP telecons, collaboration meetings, hack-weeks, and workshops. PI chaired or co-chaired sessions at collaboration meetings and hack-weeks about testing gravity and models beyond wCDM using LSST. He is coordinating the TJP2 projects for testing models beyond wCDM including the writing of DESC-research-note, development of code for pipeline, and N-Body simulations for MG and beyond wCDM models testable with LSST analyses. As stressed in the DESC white paper, SRM, and P5 report, one of the important questions in understanding cosmic acceleration and dark energy is to be able to distinguish whether the acceleration is due to a dark energy component in the universe or a modification to gravity. Answering these questions will have a significant impact on the question of cosmic acceleration and dark energy. The methods that we will use include analytical work, numerical code, and N-Body simulations. A first approach that that we will use consists of using growth rate parameters that enter the perturbed dynamics equations. These parameters take distinctive values for distinct gravity theories and have potential to distinguish between Dark Energy and Modified Gravity. The second method is to look for inconsistencies in Dark Energy parameter spaces using specific combinations of cosmological data sets. Our investigation addresses the Dark Energy problem that is relevant to the mission of the HEP program to understand how our universe works at its most fundamental level. It will allow us to make progress on the HEP mission to explore the nature of Dark Energy and the basic nature of space and time using future surveys such as LSST. The investigation supports the DOE HEP program Cosmic Frontier as it will contribute to the study and understanding of dark energy and fundamental properties of the universe. The investigation contributes directly to LSST-DESC key projects and their deliverables as described in the Science Road-map document to build analysis pipeline and to test dark energy and beyond wCDM models using LSST.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gravitational focusing and substructure effects on the rate modulation in direct dark matter searches

We study how gravitational focusing (GF) of dark matter by the Sun affects the annual and biannual modulation of the expected signal in non-directional direct dark matter searches, in the presence of dark matter substructure in the local dark halo. We consider the Sagittarius stream and a possible dark disk, and show that GF suppresses some, but not all, of the distinguishing features that would characterize substructure of the dark halo were GF neglected.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modulation of Superconducting Transition Temperature in LaAlO{sub 3}/SrTiO{sub 3} by SrTiO{sub 3} Structural Domains

The tetragonal domain structure in SrTiO{sub 3} (STO) is known to modulate the normal-state carrier density in LaAlO{sub 3}/SrTiO{sub 3} (LAO/STO) heterostructures, among other electronic properties, but the effect of STO domains on the superconductivity in LAO/STO has not been fully explored. Using a scanning SQUID susceptometer microscope to map the superconducting response as a function of temperature in LAO/STO, we find that the superconducting transition temperature is spatially inhomogeneous and modulated in a pattern that is characteristic of structural domains in the STO.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthesis of porous organic cage CC3 via solvent modulated evaporation

We demonstrate a Humidity Modulated Solvent Evaporation (HMSE) approach to promote the nucleation and growth of CC3 crystals. This approach relies on the gradual evaporation of dichloromethane (solvent) from a diluted concentration of CC3 precursors deposited on aluminum foil. The slow solvent evaporation allowed enough time for the organization and formation of CC3 porous organic cage. The solvent diffusion rate was modulated by the relative humidity in the system. The slow kinetics implied during the development of CC3 phase, allowed the formation of CC3 crystals. HRTEM, SAED, SEM, and XRD patterns were used as pivotal characterization techniques to follow and confirm the formation of CC3 crystals.

porous organic cages, modulated evaporation, cryst↗

Tailored multivariate analysis for modulated enhanced diffraction

Modulated enhanced diffraction (MED) is a technique allowing the dynamic structural characterization of crystalline materials subjected to an external stimulus, which is particularly suited for in situ and operando structural investigations at synchrotron sources. Contributions from the (active) part of the crystal system that varies synchronously with the stimulus can be extracted by an offline analysis, which can only be applied in the case of periodic stimuli and linear system responses. In this paper a new decomposition approach based on multivariate analysis is proposed. The standard principal component analysis (PCA) is adapted to treat MED data: specific figures of merit based on their scores and loadings are found, and the directions of the principal components obtained by PCA are modified to maximize such figures of merit. As a result, a general method to decompose MED data, called optimum constrained components rotation (OCCR), is developed, which produces very precise results on simulated data, even in the case of nonperiodic stimuli and/or nonlinear responses. The multivariate analysis approach is able to supply in one shot both the diffraction pattern related to the active atoms (through the OCCR loadings) and the time dependence of the system response (through the OCCR scores). When applied to real data, OCCR was able to supply only the latter information, as the former was hindered by changes in abundances of different crystal phases, which occurred besides structural variations in the specific case considered. To develop a decomposition procedure able to cope with this combined effect represents the next challenge in MED analysis.

Caliandro, Rocco↗