Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Differentiating Ferroelectric and Nonferroelectric Electromechanical Effects with Scanning Probe Microscopy

Ferroelectricity in functional materials remains one of the most fascinating areas of modern science in the past several decades. In the last several years, the rapid development of piezoresponse force microscopy (PFM) and spectroscopy revealed the presence of electromechanical hysteresis loops and bias-induced remnant polar states in a broad variety of materials including many inorganic oxides, polymers, and biosystems. In many cases, this behavior was interpreted as the ample evidence for ferroelectric nature of the system. Here, we systematically analyze PFM responses on ferroelectric and nonferroelectric materials and demonstrate that mechanisms unrelated to ferroelectricity can induce ferroelectric-like characteristics through charge injection and electrostatic forces on the tip. In this paper, we will focus on similarities and differences in various PFM measurement characteristics to provide an experimental guideline to differentiate between ferroelectric material properties and charge injection. In conclusion, we apply the developed measurement protocols to an unknown ferroelectric material.

36 MATERIALS SCIENCE↗

Rapid mapping of polarization switching through complete information acquisition

Polarization switching in ferroelectric and multiferroic materials underpins a broad range of current and emergent applications, ranging from random access memories to field-effect transistors, and tunnelling devices. Switching in these materials is exquisitely sensitive to local defects and microstructure on the nanometre scale, necessitating spatially resolved high-resolution studies of these phenomena. Classical piezoresponse force microscopy and spectroscopy, although providing necessary spatial resolution, are fundamentally limited in data acquisition rates and energy resolution. This limitation stems from their two-tiered measurement protocol that combines slow (~1 s) switching and fast (~10 kHz–1 MHz) detection waveforms. Here we develop an approach for rapid probing of ferroelectric switching using direct strain detection of material response to probe bias. This approach, facilitated by high-sensitivity electronics and adaptive filtering, enables spectroscopic imaging at a rate 3,504 times faster the current state of the art, achieving high-veracity imaging of polarization dynamics in complex microstructures.

36 MATERIALS SCIENCE↗

Quantum computing universal thermalization dynamics in a (2 + 1)D Lattice Gauge Theory

Simulating non-equilibrium phenomena in strongly-interacting quantum many-body systems, including thermalization, is a promising application of near-term and future quantum computation. By performing experiments on a digital quantum computer consisting of fully-connected optically-controlled trapped ions, we study the role of entanglement in the thermalization dynamics of a Z 2 lattice gauge theory in 2+1 spacetime dimensions. Using randomized-measurement protocols, we efficiently learn a classical approximation of non-equilibrium states that yields the gap-ratio distribution and the spectral form factor of the entanglement Hamiltonian. These observables exhibit universal early-time signals for quantum chaos, a prerequisite for thermalization. Our work, therefore, establishes quantum computers as robust tools for studying universal features of thermalization in complex many-body systems, including in gauge theories.

97 MATHEMATICS AND COMPUTING↗

Multi-pass transmission electron microscopy

Feynman once asked physicists to build better electron microscopes to be able to watch biology at work. While electron microscopes can now provide atomic resolution, electron beam induced specimen damage precludes high resolution imaging of sensitive materials, such as single proteins or polymers. Here, we use simulations to show that an electron microscope based on a multi-pass measurement protocol enables imaging of single proteins, without averaging structures over multiple images. While we demonstrate the method for particular imaging targets, the approach is broadly applicable and is expected to improve resolution and sensitivity for a range of electron microscopy imaging modalities, including, for example, scanning and spectroscopic techniques. The approach implements a quantum mechanically optimal strategy which under idealized conditions can be considered interaction-free.

47 OTHER INSTRUMENTATION↗

Quantum metrology from an information theory perspective

Questions about quantum limits on measurement precision were once viewed from the perspective of how to reduce or avoid the effects of quantum noise. With the advent of quantum information science came a paradigm shift to proving rigorous bounds on measurement precision. These bounds have been interpreted as saying, first, that the best achievable sensitivity scales as 1/n, where n is the number of particles one has available for a measurement and, second, that the only way to achieve this Heisenberg-limited sensitivity is to use quantum entanglement. We review these results and show that using quadratic couplings of n particles to a parameter to be estimated, one can achieve sensitivities that scale as 1/n{sup 2} if one uses entanglement, but even in the absence of any entanglement at any time during the measurement protocol, one can achieve a super-Heisenberg scaling of 1/n{sup 3/2}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of the magnetocaloric entropy change by field sweep using a heat flux setup

We report on a simple setup using a heat flux sensor adapted to a Quantum Design Physical Property Measurement System to determine the magnetocaloric entropy change (ΔS). The major differences for the existing setups are the simplicity of this assembly and the ease to obtain the isothermal entropy change either by a field sweep or a temperature sweep process. We discuss the use of these two processes applied to Gd and Gd{sub 5}Ge{sub 2}Si{sub 2} samples. The results are compared to the temperature sweep measurements and they show the advantages of this setup and of the field sweep procedure. We found a significant reduction of ΔS and on the refrigerating cooling power (RCP) at low field changes in a field sweep process when the sample is not driven to the same initial state for each temperature. We show that the field sweep process without any measuring protocol is the only correct way to experimentally determine ΔS and RCP for a practical regenerative refrigerator.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A broadly applicable function for describing luminescence dose response

The basic form of luminescence dose response is investigated, with the aim of developing a single function to account for the appearance of linear, superlinear, sublinear, and supralinear behaviors and variations in saturation signal level and rate. A function is assembled based on the assumption of first order behavior in different major factors contributing to measured luminescence-dosimetric signals. Different versions of the function are developed for standardized and non-dose-normalized responses. Data generated using a two trap two recombination center model and experimental data for natural quartz are analyzed to compare results obtained using different signals, measurement protocols, pretreatment conditions, and radiation qualities. The function well describes a range of dose dependent behavior, including sublinear, superlinear, supralinear, and non-monotonic responses and relative response to α and β radiation, based on change in relative recombination and trapping probability affecting signals sourced from a single electron trap.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new setup for the investigation of swift heavy ion induced particle emission and surface modifications

The irradiation with fast ions with kinetic energies of >10 MeV leads to the deposition of a high amount of energy along their trajectory (up to several ten keV/nm). The energy is mainly transferred to the electronic subsystem and induces different secondary processes of excitations, which result in significant material modifications. A new setup to study these ion induced effects on surfaces will be described in this paper. The setup combines a variable irradiation chamber with different techniques of surface characterizations like scanning probe microscopy, time-of-flight secondary ion, and neutral mass spectrometry, as well as low energy electron diffraction under ultra high vacuum conditions, and is mounted at a beamline of the universal linear accelerator (UNILAC) of the GSI facility in Darmstadt, Germany. Here, samples can be irradiated with high-energy ions with a total kinetic energy up to several GeVs under different angles of incidence. Our setup enables the preparation and in situ analysis of different types of sample systems ranging from metals to insulators. Time-of-flight secondary ion mass spectrometry enables us to study the chemical composition of the surface, while scanning probe microscopy allows a detailed view into the local electrical and morphological conditions of the sample surface down to atomic scales. With the new setup, particle emission during irradiation as well as persistent modifications of the surface after irradiation can thus be studied. We present first data obtained with the new setup, including a novel measuring protocol for time-of-flight mass spectrometry with the GSI UNILAC accelerator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A nonlinear journey from structural phase transitions to quantum annealing

Motivated by an exact mapping between equilibrium properties of a one-dimensional chain of quantum Ising spins in a transverse field (the transverse field Ising (TFI) model) and a two-dimensional classical array of particles in double-well potentials (the “$\phi$ 4 model”) with weak inter-chain coupling, we explore connections between the driven variants of the two systems. Here, we argue that coupling between the fundamental topological solitary waves in the form of kinks between neighboring chains in the classical $\phi$ 4 system is the analog of the competing effect of the transverse field on spin flips in the quantum TFI model. As an example application, we mimic simplified measurement protocols in a closed quantum model system by studying the classical $\phi$ 4 model subjected to periodic perturbations. This reveals memory/loss of memory and coherence/decoherence regimes, whose quantum analogs are essential in annealing phenomena. In particular, we examine regimes where the topological excitations control the thermal equilibration following perturbations. This paves the way for further explorations of the analogy between lower-dimensional linear quantum and higher-dimensional classical nonlinear systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Overlooked branch turnover creates a widespread bias in forest carbon accounting

Most measurements and models of forest carbon cycling neglect the carbon flux associated with the turnover of branch biomass, a physiological process quantified for other organs (fine roots, leaves, and stems). Synthesizing data from boreal, temperate, and tropical forests (184,815 trees), we found that including branch turnover increased empirical estimates of aboveground wood production by 16% (equivalent to 1.9 Pg Cy −1 globally), of similar magnitude to the observed global forest carbon sinks. In addition, reallocating carbon to branch turnover in model simulations reduced stem wood biomass, a long-lasting carbon storage, by 7 to 17%. This prevailing neglect of branch turnover suggests widespread biases in carbon flux estimates across global datasets and model simulations. Branch litterfall, sometimes used as a proxy for branch turnover, ignores carbon lost from attached dead branches, underestimating branch C turnover by 38% in a pine forest. Modifications to field measurement protocols and existing models are needed to allow a more realistic partitioning of wood production and forest carbon storage.

Lim, Hyungwoo↗

Conclusive discrimination among N equidistant pure states

We find the allowed complex overlaps for N equidistant pure quantum states. The accessible overlaps define a petal-shaped area on the Argand plane. Each point inside the petal represents a set of N linearly independent pure states and each point on its contour represents a set of N linearly dependent pure states. We find the optimal probabilities of success of discriminating unambiguously in which of the N equidistant states the system is. We show that the phase of the involved overlap plays an important role in the probability of success. For a fixed overlap modulus, the success probability is highest for the set of states with an overlap with phase equal to zero. In this case, if the process fails, then the information about the prepared state is lost. For states with a phase different from zero, the information could be obtained with an error-minimizing measurement protocol.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Identifying Majorana vortex modes via nonlocal transport

The combination of two-dimensional Dirac surface states with s-wave superconductivity is expected to generate localized topological Majorana zero modes in vortex cores. Putative experimental signatures of these modes have been reported for heterostructures of proximitized topological insulators, iron-based superconductors or certain transition metal dichalcogenides. Despite these efforts, the Majorana nature of the observed excitation is still under debate. In this work, we propose to identify the presence of Majorana vortex modes using a nonlocal transport measurement protocol originally employed for one-dimensional settings. In the case of an isolated subgap state, the protocol provides a spatial map of the ratio of local charge- and probability-density which offers a clear distinction between Majorana and ordinary fermionic modes. We show that these distinctive features survive in the experimentally relevant case of hybridizing vortex core modes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Probing electromagnetic nonreciprocity with quantum geometry of photonic states

Reciprocal and nonreciprocal effects in dielectric and magnetic materials provide crucial information about the microscopic properties of electrons. However, experimentally distinguishing the two has proven to be challenging, especially when the associated effects are extremely small. To this end, we propose a contactless detection using a cross-cavity device where a material of interest is placed at its center. We show that the optical properties of the material, such as Kerr and Faraday rotation, or birefringence, manifest in the coupling between the cavity's electromagnetic modes and in the shift of their resonant frequencies. By calculating the dynamics of a geometrical photonic state, we formulate a measurement protocol based on the quantum metric and quantum process tomography that isolates the individual components of the material's complex refractive index and minimizes the quantum mechanical Cramér-Rao bound on the variance of the associated parameter estimation. Our approach is expected to be applicable across a broad spectrum of experimental platforms including Fock states in optical cavities, or coherent states in microwave and THz resonators. Published by the American Physical Society 2025

Petrides, Ioannis (ORCID:0000000174842444)↗

Quantum-Enhanced Sensing of Axion Dark Matter with a Transmon-Based Single Microwave Photon Counter

We report an axion dark matter search with a haloscope equipped with a microwave photon counter. The haloscope is a tunable high quality factor three-dimensional microwave cavity placed in a magnetic field. The photon counter, operated cyclically, maps an incoming microwave photon onto the state of a superconducting transmon qubit. The measurement protocol continuously monitors the power emitted by the haloscope cavity as well as the dark count background and enables tuning of the cavity frequency to probe different axion masses. With this apparatus, we enhance by a factor of 20 the search speed that can be reached with quantum-limited linear amplifiers and set a new standard for probing the existence of axions with resonant detectors above 5 GHz. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In situ synchrotron X-ray total scattering measurements and analysis of colloidal CsPbX 3 nanocrystals during flow synthesis

In situ X-ray scattering measurements of CsPbX 3 (X = Cl, Br, I) nanocrystal formation and halide exchange at NSLS-II beamlines were performed in an automated flow reactor. Total scattering measurements were performed at the 28-ID-2 (XPD) beamline and small-angle X-ray scattering at the 16-ID (LiX) beamline. Nanocrystal structural parameters of interest, including size, size distribution and atomic structure, were extracted from modeling the total scattering data. The results highlight the potential of these beamlines and the measurement protocols described in this study for studying dynamic processes of colloidal nanocrystal synthesis in solution with timescales on the order of seconds.

nucleation↗

ADC Nonlinearity Correction for the Majorana Demonstrator

Imperfections in analog-to-digital conversion cannot be ignored when signal digitization requirements demand both wide dynamic range and high resolution, as is the case for the MAJORANA DEMONSTRATOR 76 Ge neutrinoless double beta decay search. Enabling the experiment's high-resolution spectral analysis and efficient pulse shape discrimination required careful measurement and correction of ADC nonlinearites. Here, a simple measurement protocol was developed that did not require sophisticated equipment or lengthy data taking campaigns. A slope-dependent hysteresis was observed and characterized. A correction applied to digitized waveforms prior to signal processing reduced the differential and integral nonlinearites by an order of magnitude, eliminating these as dominant contributions to the systematic energy uncertainty at the double-beta decay Q value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of reactive and condensable gas permeation using a mass spectrometer

Permeation of water vapor, oxygen, nitrogen, and carbon dioxide through polymer films is measured by the programed valving mass spectrometry (PVMS) method. The results are calibrated with a standard permeation rate for each gas to determine the detection sensitivity. The calibrated lower detection limits are 1.90x10{sup -7} g/m{sup 2} day for water vapor, 2.81x10{sup -2} cm{sup 3}/m{sup 2} day for oxygen, 2.15x10{sup -2} cm{sup 3}/m{sup 2} day for nitrogen, and 3.29x10{sup -2} cm{sup 3}/m{sup 2} day for carbon dioxide. The lower detection limits presented here for water vapor, nitrogen, and carbon dioxide are more than two orders of magnitude lower than the corresponding values offered by the NIST-traceable standard techniques. In addition, the PVMS water vapor lower detection limit meets the sensitivity requirement for detecting 'ultrabarrier' water vapor permeation rates, while the oxygen lower detection limit is higher than that offered by the standard technique. However, the results suggest a modified measurement protocol and/or system modifications to overcome this limitation. Effusivity through a flow orifice was also examined using the PVMS method for the above gases. The effusion results from the flow orifice, combined with the permeation results from polymer samples, provide insight into the factors that may influence gas detection sensitivities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MO-E-18C-04: Advanced Computer Simulation and Visualization Tools for Enhanced Understanding of Core Medical Physics Concepts

Purpose: Most medical physics programs emphasize proficiency in routine clinical calculations and QA. The formulaic aspect of these calculations and prescriptive nature of measurement protocols obviate the need to frequently apply basic physical principles, which, therefore, gradually decay away from memory. E.g. few students appreciate the role of electron transport in photon dose, making it difficult to understand key concepts such as dose buildup, electronic disequilibrium effects and Bragg-Gray theory. These conceptual deficiencies manifest when the physicist encounters a new system, requiring knowledge beyond routine activities. Methods: Two interactive computer simulation tools are developed to facilitate deeper learning of physical principles. One is a Monte Carlo code written with a strong educational aspect. The code can “label” regions and interactions to highlight specific aspects of the physics, e.g., certain regions can be designated as “starters” or “crossers,” and any interaction type can be turned on and off. Full 3D tracks with specific portions highlighted further enhance the visualization of radiation transport problems. The second code calculates and displays trajectories of a collection electrons under arbitrary space/time dependent Lorentz force using relativistic kinematics. Results: Using the Monte Carlo code, the student can interactively study photon and electron transport through visualization of dose components, particle tracks, and interaction types. The code can, for instance, be used to study kerma-dose relationship, explore electronic disequilibrium near interfaces, or visualize kernels by using interaction forcing. The electromagnetic simulator enables the student to explore accelerating mechanisms and particle optics in devices such as cyclotrons and linacs. Conclusion: The proposed tools are designed to enhance understanding of abstract concepts by highlighting various aspects of the physics. The simulations serve as virtual experiments that give deeper and long lasting understanding of core principles. The student can then make sound judgements in novel situations encountered beyond routine clinical activities.

60 APPLIED LIFE SCIENCES↗