Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement bandwidth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Additively Manufactured Interdigital Filters for Ultra- Wideband Radar

Abstract— In this paper, we present the development of ultrawideband (UWB) inter-digital cavity filters manufactured with an additive technique. We employed a selective laser melting process with stainless steel via a “flipping and fixturing” approach to achieve dimensional accuracy and frequency selectivity (no postfabrication tuning) comparable to that of conventional micromachining. The filters operate at a center frequency of 3.75 GHz and 6 GHz, respectively, with an instantaneous bandwidth of 2 GHz. This paper presents design and fabrication details, a discussion of measured characteristics for both filters, and a performance comparison with respect to subtractively manufactured parts.

Keywords— Interdigital filters, UWB radar, additiv↗

Measurement of Local Electric Field Turbulence in Magnetically Confined Plasmas (Final Report)

This final report describes the development of high-bandwidth plasma fluctuation diagnostics, encompassing the design and implementation of Beam Emission Spectroscopy systems on several fusion experiments such as TFTR, DIII-D and NSTX, the advancement of Alpha particle and Ultrafast Charge-Exchange Recombination Spectroscopy, and the creation of advanced spectrometers for localized studies of electric and magnetic field fluctuations based on the Motional Stark Effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of THz-bandwidth incoherent laser radiation on bulk damage in potassium dihydrogen phosphate crystals

Abstract The laser-damage performance characteristics of potassium dihydrogen phosphate (KDP) samples under exposure to a distinctive broadband incoherent laser pulse are investigated. A laser system providing such pulses is intended to explore improved energy-coupling efficiency on the target in direct-drive inertial confinement fusion experiments and provides incoherent bandwidths as large as 10 THz in a nanosecond pulse. A consequence of this bandwidth is very rapid fluctuations in intensity capable of reaching maxima much larger than the average intensity within the pulse. A custom damage-test station has been built to perform measurements with broadband incoherent pulses in order to determine what effect these fast and high-intensity oscillations have on laser damage. A set of experiments under different bandwidth and beam configurations shows the effect to be minimal when probing bulk damage in KDP. Modeling indicates this behavior is supported by long electron-relaxation times compared to the source-field fluctuations, following excitation of individual electrons in the conduction band. The results help better understand the laser-induced–damage mechanisms in KDP, and its ability to operate in broadband temporally incoherent high-energy lasers that may be particularly suitable for future laser-fusion energy systems.

36 MATERIALS SCIENCE↗

Low-Temperature Competing Magnetic Energy Scales in the Topological Ferrimagnet TbMn 6 Sn 6

TbMn 6 Sn 6 is a metallic ferrimagnet displaying signatures of both topological electrons and topological magnons arising from ferromagnetism and spin-orbit coupling within its Mn kagome layers. Inelastic neutron scattering measurements find strong ferromagnetic (FM) interactions within the Mn kagome layer and reveal a magnetic bandwidth of ~230 meV. The low-energy magnetic excitations are characterized by strong FM Mn-Mn and antiferromagnetic (AFM) Mn-Tb interlayer magnetic couplings. We observe weaker, competing long-range FM and AFM Mn-Mn interlayer interactions similar to those driving helical magnetism in the YMn 6 Sn 6 system. Combined with density-functional theory calculations, we find that competing Mn-Mn interlayer magnetic interactions occur in all RMn 6 Sn 6 compounds with R=Y, Gd-Lu, resulting in magnetic instabilities and tunability when Mn-R interactions are weak. In the case of TbMn 6 Sn 6 , strong AFM Mn-Tb coupling ensures a highly stable three-dimensional ferrimagnetic network.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Milestone Report: Co-Scheduling Applications on Current and Future Architectures

This report evaluates the viability and performance of co-scheduling scientific applications and workloads between CPUs and GPUs on current and future hardware architectures. This study was performed by collecting hardware independent and memory performance characteristics of 6 ECP mini-applications through Byfl and NSight Systems, by measuring the applications’ co-scheduled performance on current node architectures, and by gathering memory bandwidth utilization data with Intel Advisor and nvprof to begin reasoning about the feasibility of co-scheduling applications on future APU architectures.

97 MATHEMATICS AND COMPUTING↗

Measurement Adequacy for Monitoring Data Center Oscillations

Artificial intelligence (AI) training data centers with periodic load profiles can induce sustained grid oscillations across a wide frequency range, making accurate monitoring essential for reliable power system operation. This report evaluates the adequacy of existing measurement systems for monitoring such oscillations, focusing on phasor measurement units (PMUs) and point-on-wave (POW) measurement systems. The analysis shows that while PMUs are highly effective for monitoring low-frequency electromechanical oscillations, they have inherent limitations in accurately representing higher-frequency oscillations due to constraints imposed by reporting rates and the bandwidth of phasor estimation filters. Even when configured with higher reporting rates, the filtering inherent in the phasor estimation process can significantly attenuate oscillation magnitudes, potentially leading to underestimation of oscillatory behavior. This has important implications for compliance and performance monitoring of large loads. To address the limitations associated with PMU-based monitoring, the report examines the use of high-resolution POW measurements, which can capture oscillations across a broader frequency range. However, continuous POW monitoring introduces practical challenges related to large data volumes, communication bandwidth, and real-time data processing. For this reason, the report also discusses emerging approaches that use POW measurements as a complementary capability alongside PMUs to improve observability of oscillations from large data center loads.

47 OTHER INSTRUMENTATION↗

Measurement of spin-polarized photoemission from wurtzite and zinc blende gallium nitride photocathodes

Spin-polarized photoemission from wurtzite and zinc blende gallium nitride (GaN) photocathodes has been observed and measured. The p-doped GaN photocathodes were epitaxially grown and activated to negative electron affinity with a cesium monolayer deposited on their surfaces. A field-retarding Mott polarimeter was used to measure the spin polarization of electrons photoemitted from the top of the valence band. A spectral scan with a tunable optical parametric amplifier constructed to provide low-bandwidth light revealed peak spin polarizations of 17% and 29% in the wurtzite and zinc blende photocathodes, respectively. Zinc blende GaN results are analyzed with a spin polarization model accounting for experimental parameters used in the measurements, while possible mechanisms influencing the obtained spin polarization values of wurtzite GaN are discussed.

Physics↗

High precision real-time insertion device and monochromator synchronization at NSLS-II

We report that insertion devices have become the dominant photon source at synchrotron and free electron laser light source facilities the world over. Undulators, characterized by their small deflection parameter, exhibit a high degree of constructive interference in photon production from high energy charged particle beams leading to very high photon rates at specific harmonics of the fundamental frequency with relatively narrow spectral widths. Spectroscopic measurements of interest typically span several of these harmonic widths, which requires precision adjustment of an undulator’s magnetic gap to maintain peak flux within the much narrower bandwidth of a beamline monochromator at the desired energy. High precision insertion device controls are developed at NSLS-II including real-time linked control of monochromator hardware allowing for fast, high precision, hardware triggered, spectroscopic measurements. Furthermore, this fast fly scan method is described, compared statistically for self consistency, and shown to be far superior in both efficiency and accuracy as compared to standard step scan measurements.

36 MATERIALS SCIENCE↗

In-situ relative calibration of Bragg crystals with Monte Carlo line ratio analysis

X-ray line emission spectra can thoroughly characterize hot plasmas, especially when line shapes and ratios convey distinct aspects of plasma conditions. However, the high spectral resolution required for observing line shapes is often at odds with the large bandwidth required to observe many line ratios across a wide spectral range. One strategy to obtain high spectral resolution over a wide bandwidth is to use multiple crystals with calibrated reflectivity so that line intensities across different crystals can be compared. Here, we explore the use of a low-resolution, wide-bandwidth mica survey spectrometer to infer relative reflectivity of two high-resolution, narrow-bandwidth quartz crystals. Finally, a Monte Carlo error analysis determines comparable x-ray line ratios measured from both spectrometers, resulting in an in situ calibration factor and associated uncertainty for the relative reflectivity of the high-resolution crystals.

47 OTHER INSTRUMENTATION↗

Bunch Extinction Measurements at PIP-II Injector Test Facility

The PIP2 particle accelerator is a new upgrade to the Fermilab accelerator complex, featuring an 800-MeV H-superconducting linear accelerator that will inject the beam into the present Fermilab Booster. A test accelerator known as PIP-II Injector Test (PIP2IT) has been built to validate the concept of the front-end of such a machine. One of the paramount challenges of PIP2IT was to validate the bunch by bunch chopping system in the Medium Energy Beam Transport (MEBT). This paper aims to present the direct extinction measurements at PIP2IT and their analysis. These measurements have been taken by two Resistive Wall Current Monitors (RWCM) and recorded by a high bandwidth oscilloscope.

43 PARTICLE ACCELERATORS↗

Frequency stability of the SRF cavities (microphonics)

There are several proposed experiments to search for Dark Matter that will utilize SRF cavities submerged into liquid Helium. Extremely narrow bandwidth of SRF cavities (<1 Hz) and requirements for cavity frequency stability will be obligated special measures to mitigate any vibrations from external sources that will be penetrated and re-tuned cavity. In the talk recent FNAL experience of measuring microphonics of SRF cavities used for Dark Photon experiment will be presented. FNAL’s program to mitigate SRF cavity microphonics (in passive and active way) will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simons Observatory: broadband metamaterial antireflection cuttings for large-aperture alumina optics

Here we present the design, fabrication, and measured performance of metamaterial antireflection cuttings (ARCs) for large-format alumina filters operating over more than an octave of bandwidth to be deployed at the Simons Observatory (SO). The ARC consists of subwavelength features diced into the optic’s surface using a custom dicing saw with near-micrometer accuracy. The designs achieve percent-level control over reflections at angles of incidence up to 20°. The ARCs were demonstrated on four 42 cm diameter filters covering the 75 to 170 GHz band and a 50 mm diameter prototype covering the 200 to 300 GHz band. The reflection and transmission of these samples were measured using a broadband coherent source that covers frequencies from 20 GHz to 1.2 THz. These measurements demonstrate percent-level control over reflectance across the targeted pass-bands and a rapid reduction in transmission as the wavelength approaches the length scale of the metamaterial structure where scattering dominates the optical response. The latter behavior enables use of the metamaterial ARC as a scattering filter in this limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing hybrid rotational femtosecond/picosecond coherent anti-Stokes Raman spectroscopy in nitrogen at high pressures and temperatures

We demonstrate the use of hybrid rotational femtosecond/picosecond (fs/ps) coherent anti-Stokes Raman spectroscopy (HR-CARS) as a technique for temperature measurements in nitrogen gas at high pressures and temperatures. A broadband pulse shaper-adjusted 42 fs pulse interacts with a narrow-bandwidth, frequency-upconverted 5.5 ps pulse in a cell containing N 2 at pressures of 1–70 atm and temperatures of 300–1000 K. A computational code is used to model spectra and fit experimental results to obtain best-fit temperatures. We demonstrate good qualitative fits as well as good accuracy and precision between thermocouple measured and best-fit temperatures over the explored pressure and temperature regimes. The overall average percentage temperature difference between thermocouple measurements and best-fit temperatures is − <#comment/> 0 . 3 % <#comment/> with a standard deviation of 7.1%, showing the suitability of HR-CARS for characterizing high-pressure and -temperature environments.

Torge Mecker, Nils (ORCID:0000000238977170)↗

Temperature Measurements in Hypersonic Wind Tunnels via Femtosecond Coherent Anti-Stokes Raman Scattering

A femtosecond coherent anti-Stokes Raman scattering (fs CARS) instrument is developed to perform gas-phase thermometry in cold-flow hypersonic wind tunnels. Measurements are reported for Mach 8 and 14 pure-nitrogen flows. The fs CARS instrument includes a 100 fs pump/Stokes pulse and a spectrally narrow probe pulse from a second harmonic bandwidth compressor. Important experimental considerations such as limits on the pump/Stokes pulse energy are discussed. The fs CARS focusing and collimating optics are mounted on a two-axis translation stage system to scan the measurement location during a 30 second wind tunnel run. Single-laser-shot rotational CARS spectra are recorded at the laser repetition rate of 1 kHz in the wind tunnel freestream and near simple cone models. Spectral fitting is used to determine quantitative gas temperatures. Freestream temperatures at Mach 8 and 14 spanned ranges of 40–75 and 35–50 K, respectively, depending on tunnel operating conditions. Temperature variations across the central 100 mm span of the wind tunnel were quantified. Measured temperature jumps across conical bow shocks from various models varied by less than 1% from predicted values. Hypersonic boundary layer measurements were demonstrated. In conclusion, these measurements illustrate the utility and robustness of this instrument for the study of complex fluid flow phenomena in challenging ground test facilities.

Aerodynamics↗

Quasi-monoenergetic ion acceleration and neutron generation from laser-driven transverse collisionless shocks

Experiments using the OMEGA EP laser system were performed to study collisionless shock acceleration of ions driven by the interaction of a relativistically intense laser pulse with underdense plasma. The energy spectrum of accelerated ions in the direction transverse to laser propagation is measured to have several narrow-band peaks which are quasi-monoenergetic with a typical energy bandwidth of 3%. In deuterium plasmas, these ions generate a significant number of fast fusion neutrons. Particle-in-cell simulations confirm that these ions were accelerated by the interaction of transverse shocks and that the appearance of quasi-monoenergetic spectral features depends on the growth of an ion-electron two-stream instability during the interaction.

Kordell, P. (ORCID:0000000321456317)↗

ARMing the Edge: Demonstration of Edge Computing Field Campaign Report

Edge computing enables “next-to-instrument” control and intelligent data volume reduction and the potential for autonomous, adaptive measurement strategies such as for automated control of scan strategies for Doppler lidar (DL). Instruments with narrow bandwidth connections (e.g., ship and remote sites) can do scene determination and save phenomenon-appropriate data. For example, Doppler spectrum can be saved when clouds are detected by the instrument or automatic moment detection can take place in camera images and only preserve spectrum when non-monomodal spectra are detected. Automated control at the edge involves changing the sampling (temporal or scanning strategy) of an instrument to suit the phenomena both present and being studied (Jackson et al. 2020). Both data processing and instrument control introduces the possibility of a software-defined instrument.

54 ENVIRONMENTAL SCIENCES↗

Stability and Fidelity of Power-Hardware-in-the-Loop Using NREL's CGI

The presentation focuses on dynamic analysis of power hardware-in-the-loop (PHIL) experiments using National Renewable Energy Laboratory Flatirons Campus' grid simulator - 7MVA Controllable Grid Interface (CGI). A control diagram of typical PHIL experiment is described, and transfer functions of critical components are explained. An impedance-based definition of PHIL experiment bandwidth is defined using open loop transfer functions of the system. Further an example resistive divider circuit is introduced that is used to explain implication of PHIL on accuracy of simulation by comparing measured results against ideal expected signals. At the end the real-life PHIL simulation using Maui power system model is described showing various oscillation modes observed and discussing the meaning of these in context of dynamic bandwidth of simulation.

grid simulator↗