Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Direct ink write multi-material printing of PDMS-BTO composites with MWCNT electrodes for flexible force sensors

Here, with recent advances of additive manufacturing technology, direct ink write (DIW) printing has allowed to incorporate multi-material printing of various materials with freedom of design and complex geometric shapes to complete functional sensors in a one-step fabrication. This paper introduces the use of DIW 3D printing of polydimethylsiloxane (PDMS) with barium titanate (BTO) filler as stretchable composites with tunable piezoelectric properties that can be used for force sensors applications. To improve the bonding between stretchable piezoelectric composites and electrodes, multi-walled carbon nanotubes was included in the fabrication of electrodes at a fixed ratio of 11 wt. %. The alignment of the BTO dipoles was achieved through corona poling method, which applies an electric charge on the surface layer of the functional material, aligning the dipoles in the desired direction and thus gaining the piezoelectricity. Different BTO mixing ratios (10–50 wt. %) were evaluated in order to obtain tunable piezoelectric properties and compare the sensitivity with respect their elastic properties. Tensile testing and piezoelectric testing were carried out to characterize mechanical and piezoelectric properties. Results showed that fabricated PDMS with 50 wt. % BTO gave the highest piezoelectric coefficient (d 33 ) of 11.5 pC N -1 and with an output voltage of 385 mV under compression loading of >200 lbF. This demonstrates feasibility of using multi-material DIW printing to fabricate piezoelectric force sensors with integrated electrodes in one-step without compromising the flexibility of the material.

36 MATERIALS SCIENCE↗

Design of Monolithic Bi-Layer High-Z PAL-Si Hard X-ray CMOS Image Sensors for Quantum Efficiency Enhancement

This article experimentally investigates the inception of an innovative hard X-ray photon energy attenuation layer (PAL) to advance high-energy X-ray detection (20–50 keV). A bi-layer design with a thin film high-Z PAL on the top and Si image sensor on the bottom has previously demon-strated quantum yield enhancement via computational methods by the principle of photon energy down conversion (PEDC), where high-energy X-ray photon energies are attenuated via inelastic scattering down to ≤10 keV, which is suitable for efficient photoelectric absorption by Si. Quantum yield enhancement has been experimentally confirmed via a preliminary demonstration using PAL-integrated Si-based CMOS image sensors (Si CIS). Furthermore, substituting the high-Z PAL with a lower-Z material—Sn—and alternatively coupling it with a conventional scintillator ma-terial—Lutetium-yttrium oxyorthosilicate (LYSO)—have been compared to demonstrate the most prominent efficacy of monolithic integration of high-Z PAL on Si CIS to detect hard X-rays, paving the way for next-generation high-energy X-ray detection methods.

47 OTHER INSTRUMENTATION↗

Low Threshold Acquisition controller for Skipper CCDs

The development of the Skipper Charge Coupled Devices (Skipper-CCDs) has been a major technological breakthrough for sensing very weak ionizing particles. The sensor allows to reach the ultimate sensitivity of silicon material as a charge signal sensor by unambiguous determination of the charge signal collected by each cell or pixel, even for single electron-hole pair ionization. Extensive use of the technology was limited by the lack of specific equipment to operate the sensor at the ultimate performance. In this work a simple, single-board Skipper-CCD controller is presented, aimed for the operation of the detector in high sensitivity scientific applications. The article describes the main components and functionality of the Low Threshold Acquisition (LTA) together with experimental results when connected to a Skipper-CCD sensor. Measurements show unprecedented deep sub-electron noise of 0.039 e$^-_{rms}$/pix for 5000 pixel measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative Analysis of Capacitive Sensors with Different Geometrical layouts for Cable Insulation Degradation Detection

This paper presents a comparative analysis between an Interdigital Capacitor (IDC) sensor and a Serpentine Capacitive (SRC) sensor. The effects of electrode layouts on sensor performance are studied by means of finite element simulation where the geometrical dimensions (except electrode length) and material characteristics of both sensors are identical. Conformal IDC and SRC sensors with equal sensor area are modeled on a cable surface. The simulation results show a tradeoff between IDC and SRC sensors in terms of sensitivity and penetration depth. The SRC sensor shows 13.3% increase in sensitivity and 16.8% increase in capacitance compared to the IDC sensor, though the electric field penetration depth of the SRC sensor is 18.8% lower than the IDC sensor. In addition, the effects of change in electrode width, inter-electrode gap, and number of electrodes on SRC and IDC sensor comparative performance are evaluated.

Interdigital Capacitance, Serpentive Capacitive Se↗

Additively Manufactured Strain Sensing for Nuclear Reactor Applications

Real-time monitoring of materials in harsh environments is a crucial technique towards reducing innovation time in nuclear systems. The successful measurement of real time, in-situ strain measurements during nuclear reactor operation requires innovative sensing solutions, including novel sensing strategies as well as advanced sensor design, manufacturing, and materials selection. In this paper, we will discuss two primary strategies for in-situ strain measurement strategies: additively manufactured (AM) capacitive strain gauges (CSGs) and digital image correlation (DIC). Current commercial strain gauges have limited applications in reactors due to the harsh operating conditions and non-trivial attachment strategies (i.e., welding, epoxy-adhesive) that can affect both the sensing performance and the underlying substrate under testing. AM CSGs are a viable solution as they have a low profile, low hysteresis, and wireless sensing integration capabilities that will enhance nuclear sensing technologies. In this work, the mechanical and thermal performance of the AM CSGs were tested up to 300 °C using ASTM standardized testing procedures to simulate the temperatures found in existing light water reactors. The AM CSGs had a similar performance across multiple samples which correlates to analytical models. This work leads towards the development of CSGs designed for higher temperatures and additional environmental factors found in Generation-IV reactors. Non-contact sensors, such as DIC, offer a less destructive way to measure deformation of materials when compared to alternative methods of in-situ strain determination, such as weldable strain gauges. However, DIC requires high contrast surfaces, which often relies on the implementation of artificial patterns. Using traditional splatter techniques to fabricate these patterns have limitations, including poor surface adhesion and reproducibility. In this work, AM fabrication techniques were implemented to avoid such limitations. Accordingly, aerosol jet printing (AJP) was used to print small scale periodic patterns of silver on stainless steel and aluminum tensile specimens. DIC was employed to monitor strain (up to 1100 µe) during temperature cycling from 23-600 °C. The results validated the use of AJP to better control pattern parameters for small fields of view applications at high temperatures.

36 MATERIALS SCIENCE↗

Embedding sensors in 3D-printed silicon carbide

An improved method for embedding one or more sensors in SiC is provided. The method includes depositing a binder onto successive layers of a SiC powder feedstock to produce a dimensionally stable green body have a true-sized cavity. A sensor component is then press-fit into the true-sized cavity. Alternatively, the green body is printed around the sensor component. The assembly (the green body and the sensor component) is heated within a chemical vapor infiltration (CVI) chamber for debinding, and a precursor gas is introduced for densifying the SiC matrix material. During infiltration, the sensor component becomes bonded to the densified SiC matrix, the sensor component being selected to be thermodynamically compatible with CVI byproducts at elevated temperatures, including temperatures in excess of 1000° C.

Petrie, Christian M.↗

A Miniaturized, High-Bandwidth Optical Fiber Fabry–Perot Cavity Vibration Sensor Demonstrated up to 800 °C

A typical structural health monitoring technique involves measuring the vibrational characteristics of components or systems to detect signs of degradation or damage. Many industrial applications require engineered systems to safely operate under extreme, high-temperature environments that pose challenges not only to materials but also to sensors that would be used for structural health monitoring. Here, in this study, miniaturized optical Fabry-Perot cavities (FPCs) were developed and tested as a means of measuring the resonant frequencies of metal components that are most relevant to extreme-environment applications. Two of the three candidate FPC designs tested up to 800 ° C provided accurate measurements (validated by theoretical models and laser Doppler vibrometry) of the fundamental vibrational mode of the specimen to which each was bonded, although both sensors failed during thermal cycling. An analysis of the reflected optical spectrum from the FPC and X-ray computed tomography revealed two opportunities to improve the sensor reliability. First, the Cu optical fiber coating that was used could either be replaced with a more oxidation-resistant material or protected with commercially available films. Second, the adhesives used to bond the fibers to metal capillaries and establish the FPC could be replaced with a more robust solution, although the Resbond 907TS adhesive appeared to outperform Resbond 907.

Birri, Anthony [Oak Ridge National Laboratory (ORN↗

Reflective Fiber Temperature Probe Based on Localized Surface Plasmon Resonance towards Low-Cost and Wireless Interrogation

Reflection fiber temperature sensors functionalized with plasmonic nanocomposite material using intensity-based modulation are demonstrated for the first time. Characteristic temperature optical response of the reflective fiber sensor is experimentally tested using Au-incorporated nanocomposite thin films deposited on the fiber tip, and theoretically validated using a thin-film-optic-based optical waveguide model. By optimizing the Au concentration in a dielectric matrix, Au nanoparticles (NP) exhibit a localized surface plasmon resonance (LSPR) absorption band in a visible wavelength that shows a temperature sensitivity ~0.025%/°C as a result of electron–electron and electron–phonon scattering of Au NP and the surrounding matrix. Detailed optical material properties of the on-fiber sensor film are characterized using scanning electron microscopy (SEM) and focused-ion beam (FIB)-assisted transmission electron microscopy (TEM). Airy’s expression of transmission and reflection using complex optical constants of layered media is used to model the reflective optical waveguide. A low-cost wireless interrogator based on a photodiode transimpedance-amplifier (TIA) circuit with a low-pass filter is designed to integrate with the sensor. The converted analog voltage is wirelessly transmitted via 2.4 GHz Serial Peripheral Interface (SPI) protocols. Feasibility is demonstrated for portable, remotely interrogated next-generation fiber optic temperature sensors with future capability for monitoring additional parameters of interest.

47 OTHER INSTRUMENTATION↗

Freestanding BaTiO 3 ‐Au Vertically Aligned Nanocomposite toward Flexible Multi‐Sensing Platform

Abstract Flexible and wearable sensors show enormous potential for personalized healthcare devices by real‐time monitoring of an individual's health. Typically, a single functional material is selected for one sensor to sense a particular physical signal while multiple materials will be selected for multi‐mode sensing. Vertically aligned nanocomposites (VANs) have recently demonstrated various material combinations and novel coupled multifunctionalities that are hard to achieve in any single‐phase material alone, including multiphase multiferroics, magneto‐optic coupling, and strong magnetic and optical anisotropy. Integrating these novel VANs into wearable sensors shows enormous potential in multi‐mode sensing owing to their multifunctional nature. In this work, the transfer of VANs onto polydimethylsiloxane as a novel flexible chemical and pressure sensor is demonstrated. For this demonstration, the classical BaTiO 3 ‐Au VAN with combined plasmonic and piezoelectric properties is used to demonstrate a multi‐sensing mechanism. A thin water‐soluble buffer of Sr 3 Al 2 O 6 serves as a buffer layer for the epitaxial growth and transfer process. The electrical output based on the piezoelectric responses and identifying 4‐mercaptobenzoic acid by surface‐enhanced Raman spectroscopy reveal great potential for free‐standing VANs in a wearable multifunctional sensing platform.

Tsai, Benson Kunhung [School of Materials Engineer↗

High temperature thick film sensor development based on doped lanthanum chromites refractory semiconductors materials

High temperature advanced sensing materials have generated high demand due the high accuracy temperature measurements requirements for process optimization, controlling and sensing. Some technological applications of harsh conditions sensing include monitoring tiles of space shuttles, rotating bearings in aircraft engines, turbines, jet engines dynamics and chemical reactors. High temperature conditions limit the sensing strategies, where typically traditional metal thermocouples are unstable, and the sensing options are limited to optical spectroscopy methods. Recently, refractory semiconductors thick- and thin-film thermocouples have been developed and, in many cases, preferred over conventional metallic thermocouples due their spatial resolution, and capability of direct deposition on any surface. Rare earth chromites ceramics materials, exhibit some properties of interest for high temperature sensing technologies development, such as: high microstructure and sintering stability, excellent conductive behavior at high temperatures, and matching thermal expansion coefficients relative to other conductors and refractory ceramics. In this work, high performance ultra-high temperature thermocouples using p-type and n-type doped lanthanum chromites materials were fabricated and tested at temperatures up to 1500 o C. Thermoelectric voltage, Seebeck Coefficients were established for all devices, evidencing high stability and performance in prolongated operational time and harsh conditions.

20 FOSSIL-FUELED POWER PLANTS↗

Proliferation Detection via Acoustic Monitoring of Pyroprocessing Equipment and Related Systems

In support of nuclear safeguards and nonproliferation, this effort is leveraging acoustic and seismic sensors to advance detection of pyroprocessing activities. Pyroprocessing, or electrochemical processing, is a method of separating irradiated nuclear fuel into its actinide and fission product components, enabling the reuse of fuel materials and reducing the radiotoxicity of the remaining waste. Verification and accountability in the process poses several challenges because of the high radiation environment and the presence of material holdup through the facility. Irregular or unaccounted-for equipment operation can signify diversion or misuse of critical materials. Acoustic and seismic sensors offer the capability to identify periods of equipment operation and help verify adherence to accountancy records.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Zinc Oxide–Graphene Nanocomposite-Based Sensor for the Electrochemical Determination of Cetirizine

A nanocomposite electrode of graphene (Gr) and zinc oxide (ZnO) nanoparticles was fabricated to study the electrochemical oxidation behavior of an anti-inflammatory drug, i.e., cetirizine (CET). The voltametric response of CET for bare CPE, Gr/CPE, ZnO/CPE, and the ZnO-Gr nanocomposite electrode was studied. The modifier materials were characterized using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and X-ray powder diffraction (XRD) to comprehend the surface morphology of the utilized modifiers. The influence of pH, scan rate, and accumulation time on the electrooxidation of CET was examined. It was found that the electrochemical oxidation of CET was diffusion-controlled, in which two protons and two electrons participated. The detection limit was found to be 2.8 × 10 -8 M in a linearity range of 0.05–4.0 µM. Study of excipients was also performed, and it was found that they had negligible interference with the peak potential of CET. The validation and utility of the fabricated nanocomposite sensor material were examined by analyzing clinical and biological samples. Stability testing of the nanocomposite electrode was conducted to assess the reproducibility, determining that the developed biosensor has good stability and high efficiency in producing reproducible results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Additively manufactured tamper evident container

A tamper evident container includes a container body having walls surrounding a cavity. The walls are composed of a non-electrically conductive material and at least one integrity sensor that is embedded in the non-electrically conductive material. A monitoring circuit is configured to monitor the tamper evident container using the at least one integrity sensor and determine a state-of-health of the tamper evident container.

Bernardin, John D.↗

Evaluation of measuring thermal conductivity of isotropic and anisotropic thermally insulating materials by transient plane source (Hot Disk) technique

The transient plane source (TPS) technique, also referred as the Hot Disk method, has been widely used due to its ability to measure the thermal properties of an extensive range of materials (solids, liquids, and powder). Recently, it has been recognized that typical Hot Disk sensors can influence TPS results of thermally insulating materials and lead to an overestimation of thermal conductivity. Although improvements have been proposed, they have not yet been implemented in the commercial TPS, leaving researchers with non-standardized modifications or options provided by a commercial Hot Disk apparatus. An empirical study of thermally insulating materials such as extruded polystyrene (XPS) and aerogel blanket is conducted in order to address the factors that affect the reliability of thermal conductivity k obtained using the commercial TPS apparatus. Sensor size, input power, duration of the measurements, applied pressure, and, in the case of anisotropic materials, heat capacity are investigated, and the results are compared with those using a Heat Flow Meter apparatus. The effect of sensor size on the k value is ascribed to heat loss through connecting leads and is more pronounced in smaller sensors and in materials with lower k values . In the case of XPS and aerogel, the effect becomes minimal for sensors with a radius r ≥ 6.4 mm. The low input power yields a high scattering of the results and should be avoided. Applied contact pressure and the tested region of the specimen play an important role in experiments with low-density fibrous materials due to the large percentage of heat being transferred by radiation and the heterogeneous nature of the samples, respectively. Additionally, the sensitivity of anisotropic measurements to the value of the material’s volumetric heat capacity ( ρC p ) is shown, emphasizing the need for the precise determination.

thermal conductivity↗

Retractable Sensor Poster for ANIMMA 2023 Conference

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-pile environment. The test environment within these reactors are extremely harsh and long-term exposure causes sensor decalibration or failure. Most tests only require data points at daily intervals meaning that the sensor does not necessarily need to be in place continuously for the full experiment. One proposed solution to the issue described above is to have a sensor which can be periodically inserted through a guide tube into the test region and retracted; this would act as a reference check on the sensors installed permanently. If a compact and robust enough design can be made, it has the potential to extend the life of the sensor and keep it within calibration. This LRS entry is for a poster summarizing a presentation that will be given at the ANIMMA 2023 conference. The poster will be on display in the Measurement Sciences Laboratory booth at ANIMMA. Most of the material on this poster came from LRS entry INL/CON-23-72797.

42 ENGINEERING↗