Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low-load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Non-Coalescence in Microgravity: Science and Technology

In this project we examine non-coalescence and non-wetting phenomena driven by either thermocapillary convection or forced motion of one surface relative to the other. In both cases, the non-coalescence or non-wetting is enabled by the existence of a lubricating layer of gas that exists to keep the two surfaces in question from coming into contact with one another. Recent progress has been made on several fronts: 1) measurement of the vibrational modes of pinned droplets; 2) development of an apparatus for the measurement of the frictional forces associated with a non-wetting droplet sliding over a solid surface; 3) measurements of the failure modes for non-wetting droplets and the influence of static electric charge on failure-, and 4) numerical simulation of a two-dimensional non-wetting droplet revealing a possible explanation for why the phenomenon has not been able to be observed using water as the droplet liquid. Issue 1) above is of relevance to the use of non-wetting droplets as positioning mechanisms and vibration dampers in a microgravity environment; issue 2) relates to the use of non-wetting droplets as nearly 'frictionless' bearings in low-load applications. Understanding of the failure modes identified in 3) is of importance to any potential application and the numerical simulations conducted under 4) allow us to obtain information about these systems that is currently not available through experimentation Each of these topics will be discussed briefly during the presentation.

Neitzel, G. Paul↗

Hindlimb unloading alters ligament healing

We investigated the hypothesis that hindlimb unloading inhibits healing in fibrous connective tissue such as ligament. Male rats were assigned to 3- and 7-wk treatment groups with three subgroups each: sham control, ambulatory healing, and hindlimb-suspended healing. Ambulatory and suspended animals underwent surgical rupture of their medial collateral ligaments, whereas sham surgeries were performed on control animals. After 3 or 7 wk, mechanical and/or morphological properties were measured in ligament, muscle, and bone. During mechanical testing, most suspended ligaments failed in the scar region, indicating the greatest impairment was to ligament and not to bone-ligament insertion. Ligament testing revealed significant reductions in maximum force, ultimate stress, elastic modulus, and low-load properties in suspended animals. In addition, femoral mineral density, femoral strength, gastrocnemius mass, and tibialis anterior mass were significantly reduced. Microscopy revealed abnormal scar formation and cell distribution in suspended ligaments with extracellular matrix discontinuities and voids between misaligned, but well-formed, collagen fiber bundles. Hence, stress levels from ambulation appear unnecessary for formation of fiber bundles yet required for collagen to form structurally competent continuous fibers. Results support our hypothesis that hindlimb unloading impairs healing of fibrous connective tissue. In addition, this study provides compelling morphological evidence explaining the altered structure-function relationship in load-deprived healing connective tissue.

NASA Discipline Musculoskeletal↗

BASS Code Development

The BASS computational aeroacoustic code solves the fully nonlinear Euler equations in the time domain in two-dimensions. The acoustic response of the stator is determined simultaneously for the first three harmonics of the convected vortical gust of the rotor. The spatial mode generation, propagation and decay characteristics are predicted by assuming the acoustic field away from the stator can be represented as a uniform flow with small harmonic perturbations superimposed. The computed field is then decomposed using a joint temporal-spatial transform to determine the wave amplitudes as a function of rotor harmonic and spatial mode order. This report details the following technical aspects of the computations and analysis. 1) the BASS computational technique; 2) the application of periodic time shifted boundary conditions; 3) the linear theory aspects unique to rotor-stator interactions; and 4) the joint spatial-temporal transform. The computational results presented herein are twofold. In each case, the acoustic response of the stator is determined simultaneously for the first three harmonics of the convected vortical gust of the rotor. The fan under consideration here like modern fans is cut-off at +, and propagating acoustic waves are only expected at 2BPF and 3BPF. In the first case, the computations showed excellent agreement with linear theory predictions. The frequency and spatial mode order of acoustic field was computed and found consistent with linear theory. Further, the propagation of the generated modes was also correctly predicted. The upstream going waves propagated from the domain without reflection from the in ow boundary. However, reflections from the out ow boundary were noticed. The amplitude of the reflected wave was approximately 5% of the incident wave. The second set of computations were used to determine the influence of steady loading on the generated noise. Toward this end, the acoustic response was determined with three steady loading conditions: design, low-loading, high-loading. The overall trend showed significant (approximately 10 dB) increases in the generated noise for the highly loaded stator.

Sawyer, Scott↗

Large-Strain Transparent Magnetoactive Polymer Nanocomposites

A document discusses polymer nano - composite superparamagnetic actuators that were prepared by the addition of organically modified superparamagnetic nanoparticles to the polymer matrix. The nanocomposite films exhibited large deformations under a magnetostatic field with a low loading level of 0.1 wt% in a thermoplastic polyurethane elastomer (TPU) matrix. The maximum actuation deformation of the nanocomposite films increased exponentially with increasing nanoparticle concentration. The cyclic deformation actuation of a high-loading magnetic nanocomposite film was examined in a low magnetic field, and it exhibited excellent reproducibility and controllability. Low-loading TPU nanocomposite films (0.1-2 wt%) were transparent to semitransparent in the visible wavelength range, owing to good dispersion of the magnetic nanoparticles. Magnetoactuation phenomena were also demonstrated in a high-modulus, high-temperature polyimide resin with less mechanical deformation.

Meador, Michael A.↗

Relocatable 10 kW Solar Array for Lunar South Pole Missions

Deployable, relocatable, free-standing solar arrays are being developed to provide modular power for future lunar South Pole missions. Major design requirements for these arrays will be low mass, compact launch stowage, and highly reliable deployment and retraction. This paper presents a novel conceptual design for a10 kW solar array to address these requirements referred to as the Relocatable Solar Array (RSA).Simply stated, the concept is a pair of solar cell blankets freely hanging from a horizontal cross arm supported by a vertical, slender, telescoping mast resting on a deployable tripod base. A major factor in simplifying the design is that the force exerted by lunar gravity is used to deploy and maintain extension of the hanging array blankets. A second major factor in achieving the desired low mass and high volumetric efficiency is that the array operates in the vacuum, low-gravity, lunar environment with no deployed vibration frequency requirement. Such a low-load environment enables use of extraordinarily slender and low mass structural members to support the hanging array blankets. This concept was developed, in part, to serve as a NASA reference solar array concept against which other proposed arrays can be compared.

Lunar Surface Power↗

Building America Case Study: Lancaster County Career and Technology Center Green Home 3, Mt Joy, Pennsylvania

Transitioning from standard light frame to a thermal mass wall system in a high performance home will require a higher level of design integration with the mechanical systems. The much higher mass in the ICF wall influences heat transfer through the wall and affects how the heating and cooling system responds to changing outdoor conditions. This is even more important for efficient, low-load homes with efficient heat pump systems in colder climates where the heating and cooling peak loads are significantly different from standard construction.This report analyzes a range of design features and component performance estimates in an effort to select practical, cost-effective solutions for high performance homes in a cold climate. Of primary interest is the influence of the ICF walls on developing an effective air sealing strategy and selecting an appropriate heating and cooling equipment type and capacity. The domestic water heating system is analyzed for costs and savings to investigate options for higher efficiency electric water heating. A method to ensure mechanical ventilation air flows is examined. The final solution package includes high-R mass walls, very low infiltration rates, multi-stage heat pump heating, solar thermal domestic hot water system, and energy recovery ventilation. This solution package can be used for homes to exceed 2012 International Energy Conservation Code requirements throughout all climate zones and achieves the DOE Challenge Home certification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Solar Water Heating in Multifamily Buildings, Greenfield, Massachusetts

Solar domestic hot water (SDHW) systems have been installed on buildings for decades, but because of relatively high costs they have not achieved significant market penetration in most of the country. As more buildings move towards zero net energy consumption, however, many designers and developers are looking more closely at SDHW. In multifamily buildings especially, SDHW may be more practical for several reasons: (1) When designing for zero net energy consumption, solar water heating may be part of the lowest cost approach to meet water heating loads. (2) Because of better scale, SDHW systems in multifamily buildings cost significantly less per dwelling than in single-family homes. (3) Many low-load buildings are moving away from fossil fuels entirely. SDHW savings are substantially greater when displacing electric resistance water heating. (4) In addition to federal tax incentives, some states have substantial financial incentives that dramatically reduce the costs (or increase the benefits) of SDHW systems in multifamily buildings. With support from the U.S. DOE Building America program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in spring of 2014, and CARB has been monitoring performance of the water heating systems since May 2014.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Net-Zero Energy Home Grows Up: Lessons and Puzzles from 10 Years of Data; Preprint

In 2005, Habitat for Humanity of Metro Denver, with support from NREL and other partners, built one of the first homes in the US to achieve net-zero energy based on monitored data. A family of three moved into the house when it was completed and lives there still. The home has been monitored continuously for the past ten years. Although PV production has remained steady, net energy performance has varied each year. The home was a net producer of energy annually in each of the first three years and in the ninth year, but not in years four through eight. Over the years, the PV system provided between 124% and 64% of the home source energy use. Electricity use in the home increased steadily during the first eight years, even though no significant new appliance was introduced into the house, such as a window air conditioner. Miscellaneous electric loads and space heating, both strongly dependent on occupant behavior, appear to be primarily responsible for the observed increase in energy use. An interesting aspect of this case study is how, even within a single family, natural changes in occupant lifestyles over time (e.g., kids growing up, schedules changing) can substantially impact the overall energy intensity of a home. Data from the last ten years will be explored for lessons learned that can improve the way we design low-load homes without sacrificing comfort or convenience for the occupants, and how we can make realistic predictions of long-term energy performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Solar Water Heating in Multifamily Buildings

Solar domestic hot water (SDHW) systems have been installed on buildings for decades, but because of relatively high costs they have not achieved significant market penetration in most of the country. As more buildings move towards zero net energy consumption, however, many designers and developers are looking more closely at SDHW. In multifamily buildings especially, SDHW may be more practical for several reasons: (1) When designing for zero net energy consumption, solar water heating may be part of the lowest cost approach to meet water heating loads. (2.) Because of better scale, SDHW systems in multifamily buildings cost significantly less per dwelling than in single-family homes. (3) Many low-load buildings are moving away from fossil fuels entirely. SDHW savings are substantially greater when displacing electric resistance water heating. (4) In addition to federal tax incentives, some states have substantial financial incentives that dramatically reduce the costs (or increase the benefits) of SDHW systems in multifamily buildings. With support form the U.S. DOE Building America program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in spring of 2014, and CARB has been monitoring performance of the water heating systems since May 2014.

Building America↗

A Net-Zero Energy Home Grows Up: Lessons and Puzzles from 10 Years of Data

In 2005, Habitat for Humanity of Metro Denver, with support from NREL and other partners, built one of the first homes in the US to achieve net-zero energy based on monitored data. A family of three moved into the house when it was completed and lives there still. The home has been monitored continuously for the past ten years. Although PV production has remained steady, net energy performance has varied each year. The home was a net producer of energy annually in each of the first three years and in the ninth year, but not in years four through eight. Over the years, the PV system provided between 124% and 64% of the home source energy use. Electricity use in the home increased steadily during the first eight years, even though no significant new appliance was introduced into the house, such as a window air conditioner. Miscellaneous electric loads and space heating, both strongly dependent on occupant behavior, appear to be primarily responsible for the observed increase in energy use. An interesting aspect of this case study is how, even within a single family, natural changes in occupant lifestyles over time (e.g., kids growing up, schedules changing) can substantially impact the overall energy intensity of a home. Data from the last ten years will be explored for lessons learned that can improve the way we design low-load homes without sacrificing comfort or convenience for the occupants, and how we can make realistic predictions of long-term energy performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: High-Velocity Small-Diameter Duct System, Pittsburgh, Pennsylvania

This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: High-Velocity Small-Diameter Duct System, Pittsburgh, Pennsylvania

This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

Building America↗

Improving Flexibility and Performance of Staged Pressurized Oxy-Combustion

Staged pressurized oxy-combustion (SPOC) is a novel coal combustion power technology being developed by Washington University in St. Louis (WUSTL) that offers the potential to deliver low-carbon power at a reduced cost. Oxy-combustion plants operate by removing most of the nitrogen contained in air prior to combustion, thereby burning fuel in a near-pure oxygen stream instead of air. This combustion produces a flue gas containing primarily carbon dioxide (CO 2 ) and water vapor that allows relatively straightforward CO 2 capture. First-generation, atmospheric oxy-combustion technology relies on a flue gas recycle (FGR) diluent to reduce the peak temperatures achieved and the resulting high thermal radiation levels that would otherwise occur in a fuel/oxygen only flame. In contrast, by staging the combustion in several steps, SPOC reduces the peak temperatures of combustion without resorting to a high degree of FGR to control flame temperatures. The SPOC process operates by utilizing two or more pressurized boiler modules connected in series to produce fuel staging; hence, only a portion of the fuel is combusted in any given combustion module. Subsequently the thermal energy released at each stage can be captured and removed from the gases prior to subsequent stages, when more fuel is introduced. This allows the SPOC process to operate with minimal FGR, avoiding the associated efficiency losses and additional costs. While the staging controls the heat release profile in SPOC, operating in a pressurized condition yields a more compact system, reducing modular boiler size and delivering enhanced heat transfer. Additionally, operating at elevated pressures ensures that the latent heat of moisture available from moisture in the fuel and generated by the combustion of the hydrogen content in the fuel can be captured as useful thermal energy for steam turbine integration. This is possible due to elevated dew point from the high partial pressure of the moisture generated in this process, which allows substantial feedwater heater bypassing to be achieved. The inclusion of this thermal energy, normally lost to the atmosphere in traditional combustion processes or to cooling systems in atmospheric oxy-combustion, allows the resultant net efficiency of the SPOC system to be up to 6 percentage points greater than first-generation systems. To begin the process of developing this technology for full-scale application, the Electric Power Research Institute, Inc. teamed up with WUSTL, American Air Liquide, Doosan Babcock, and the U.S. Department of Energy to investigate a practical and workable boiler design concept that would minimize process risks where possible. The SPOC system offers unique process flexibility opportunities due to the staged nature of the combustion, making it a prime candidate for future primary energy delivery where the ability to operate at reduced load in an efficient manner and ramp rapidly will be valuable for balancing intermittent renewable electricity generation. The efficiency of traditional coal-fired power plants is lower at reduced loads below the steam temperature control range due to the challenges in balancing the heat pickup between radiative and convective superheater and reheater surface. Introducing additional heating surface for optimal extended controlled low load operation will likely lead to excessive attemperation at high loads, ultimately leading to a poorer overall cycle efficiency. The SPOC process can facilitate the adjustment of fuel firing rates between stages, targeting heat pickup to where it is most needed and potentially can shut down stages for low-load operation, facilitating an increased steam temperature control range on turndown. The boiler design concept assessment is being carried out to identify the maximum permissible compactness of the SPOC boiler heating surfaces. The assessment will determine the minimum overall height that will deliver appropriate tube operating metal temperatures at full load and achieve rated reheat steam temperatures at low operating loads, balanced against the needs of efficient coal combustion, and the potential resultant slagging and ash environments. The design parameters are being validated by combustion testing in the 100-kWth pressurized combustion test rig at WUSTL. Parameters being investigated include flame stability, fuel burnout, ash composition, radiative heat flux, and temperature profiles. These are being carried out for a range of inlet gas conditions and compositions and at multiple load conditions to investigate combustion stability at reduced load. The results of this testing inform the modeling of the large-scale system, that was sized at 550 MWe to allow direct comparison with the National Energy Technology Laboratory baseline cases for atmospheric oxy-combustion, air firing, and air firing with post-combustion capture.

20 FOSSIL-FUELED POWER PLANTS↗

Dynamic Characterization and Performance Evaluation of a 10-kw Power Take-Off with Mechanical Motion Rectifier for Wave Energy Conversion

The power take-off (PTO) is a key component for wave energy converters (WECs). The dynamic properties of the PTO influence the response of the WEC and should be considered when designing the WEC and not oversimplified. In addition, the efficiency as well as the reliability can play an important role on whether the PTO can be suitable for real-world applications. In this paper, a novel compact PTO rated at 10 kW is designed and prototyped, and a comprehensive nonlinear dynamic model is established for the PTO. Through bench testing, the unknown parameters of the dynamic model are characterized and determined. Further verification shows that the model can predict the dynamic performance of the PTO well. In addition, the test results show that the mechanical motion rectifier PTO can achieve good energy transfer efficiency, especially for low-load and low-speed conditions.

bench test↗

Effect of occupant behavior on peak cooling and dehumidification loads in typical and high-efficiency homes

Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure, installing the ductwork in conditioned space, and improving the building's airtightness results in significant reductions in externally-driven sensible and latent cooling loads. As a building's efficiency is improved, occupant-related internal gains become a larger portion of the building sensible and latent loads. Additionally, internal gains are highly uncertain compared to other load components. In this study, we use a stochastic approach to simulate occupant-related internal gains and compare the internal gains to other sensible and latent heat sources in four house efficiency levels in 10 U.S. climates using whole-building energy simulation software. We compare the expected range in occupant-related internal gains to other building characteristics such as cooling set point, air infiltration rate, and mechanical ventilation rate. We show that in high-efficiency homes, sensible internal gains vary from less than 10% to greater than 40% of the building sensible load under peak total cooling conditions depending on climate and internal gain profile. Likewise, latent internal gains vary from less than 10% to more than 60% of the building latent load under peak total cooling and peak dehumidification conditions depending on climate and internal gain profile.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mesoscopic modeling of transport resistances in a polymer-electrolyte fuel-cell catalyst layer: Analysis of hydrogen limiting currents

Understanding transport resistances in a polymer-electrolyte fuel cell (PEFC) catalyst layer (CL) is essential to mitigate the unexpected voltage loss when using low loadings of precious metals. In this paper, we explore through mesoscopic modeling the quantification analyses of the transport resistances in CL as derived using hydrogen-pump limiting current. Numerical treatments on the conjugated interfacial conditions at interfaces of ionomer/pore and Pt/ionomer are proposed to describe the mesoscopic transport processes of hydrogen and proton. Characterizations of the reconstructed microstructure of CL are performed. Parameter analyses on the influences of the critical transport properties such as the permeation coefficient and the dissolution and adsorption reaction rates at the surfaces of ionomer/pore and Pt/ionomer on the local transport resistance are presented. It is found that the local transport resistance is mainly originated from the diffusion resistance of the ionomer thin-film, which is more resistive than its bulk analogue with its permeation coefficient fitted to be 5.9% of the bulk one. The interfacial transport resistances and the diffusion resistance are coupled. The local transport resistance increases with I/C ratio due to thicker ionomer coated on the particles. Higher Pt/C ratio and bare carbon fraction lead to higher local transport resistance since the ionomer loading relative to Pt roughness factor decreases. The local transport resistance decreases with the porosity. Furthermore, the contribution of pores to the CL resistance, which decreases with the porosity, is comparatively small at low loadings.

25 ENERGY STORAGE↗

Effect of occupant behavior and air-conditioner controls on humidity in typical and high-efficiency homes

Increasing insulation levels and improved windows are reducing sensible cooling loads in high-efficiency homes. This trend raises concerns that the resulting shift in the balance of sensible and latent cooling loads may result in higher indoor humidity, occupant discomfort, and stunted adoption of high-efficiency homes. This study utilizes established moisture-buffering and air-conditioner latent degradation models in conjunction with an approach to stochastically model internal gains. Building loads and indoor humidity levels are compared for simulations of typical new construction homes and high-efficiency homes in 10 US cities. The sensitivity of indoor humidity to changes in cooling set point, air-conditioner capacity, and blower control parameters are evaluated. The results show that high-efficiency homes in humid climates have cooling loads with a higher fraction of latent loads than the typical new construction home, resulting in higher indoor humidity. Reducing the cooling set point is the easiest method to reduce indoor humidity, but it is not energy efficient, and overcooling may lead to occupant discomfort. Eliminating the blower operation at the end of cooling cycles and reducing the cooling airflow rate also reduce indoor humidity and with a smaller impact on energy use and comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗