At least 127 records · Page 7

Low-temperature operation of a Buck DC/DC converter

Low-temperature (77 K) operation of a 42/28 V, 175 W, 50 kHz PWM Buck DC/DC converter designed with commercially available components is reported. Overall, the converter losses decreased at 77 K compared to room temperature operation. A full-load efficiency of 97 percent was recorded at liquid-nitrogen temperature, compared to 95.8 percent at room temperature. Power MOSFET operation improved significantly where as the output rectifier operation deteriorated at low-temperature. The performance of the output filter inductor and capacitor did not change significantly at 77 K compared to room temperature performance. It is possible to achieve high-density and high efficiency power conversion at low-temperatures due to improved electronic, electrical and thermal properties of materials.

Ray, Biswajit↗

On the product phases and the reaction kinetics of carbothermic reduction of UO 2 +C at relatively low temperatures

The synthesis of UC using carbothermic reduction of UO 2 and C mixtures has been well studied at high temperatures. However, the product phase behavior of carbothermic reduction at low temperatures (≤1773 K) is not well studied. Such a study is important as low temperatures permit single phase UC synthesis without forming secondary higher carbides, and it further supports the knowledge base of the process that needs to be used for transuranic elements such as plutonium that have high vapor pressures at elevated temperatures. Therefore, a low temperature carbothermic reduction of two different C/UO 2 molar ratios under inert and reducing environments have been studied here. Two different sample holding crucibles, alumina (Al 2 O 3 ) and graphite, were also used here to differentiate the hypostoichiometric (UC 1-a ) and oxygen dissolved (UC 1-x O x ) uranium monocarbide phases adding more details on the two systems. Also, the reaction kinetics involved in the formation of UC via the carbothermic reduction of UO 2 +C using product phases instead of evolved gases such as carbon monoxide is reported here. Under inert atmospheres but with significant oxygen partial pressures, the low temperature carbothermic reduction of UO 2 +C produced up to 90 wt.% UC 1-x O x type oxycarbides as was confirmed by Xray powder diffraction. Reducing Ar-4%H 2 environments at these temperatures were not successful in synthesizing UC as it reduces the amount of C required for the carbothermic reduction, leaving UC phase at a non-equilibrium state. Inert atmospheres with low or negligible oxygen partial pressures on the other hand produced near stoichiometric UC at high phase purity, especially at 1673 – 1773 K temperature range. An activation energy of 377±75 kJmol -1 was also calculated using product phase concentrations of the carbothermic reduction of UO 2 +C under these inert Ar (g) atmospheres.

36 MATERIALS SCIENCE↗

Geothermal Play Fairway Analysis of Low-Temperature Resources for Sedimentary Basin Geothermal Play Types: An Example in the Denver Basin

This project is part of a nationwide effort to highlight the advantages of incorporating low-temperature geothermal resource evaluation into the implementation of combined heat and power (CHP), and geothermal direct use (GDU) technologies (e.g., space heating and/or cooling). The initiative aims to hasten the nation's decarbonization process by exploring the potential for using low-temperature geothermal resources (< 150 Degrees Celsius) in selected sedimentary basins that have several population centers. The Play Fairway Analysis (PFA) techniques were modified from earlier studies of sedimentary basin geothermal play types (SBGPTs) that assessed the viability of low-temperature resources. The decision-making process for leveraging low-temperature geothermal resources for GDU and CHP applications is complex and considers a variety of factors, including geological, economic, and risk criteria. This study covers workflows, relevant datasets, python code, and both common and composite maps used to create low-temperature geothermal resource favorability maps for the Denver Basin, which extends across Colorado, Nebraska, and Wyoming. The replication of these methodologies in other SBGPTs can evaluate potential for low-temperature resources. The proposed geothermal PFA approach for low-temperature geothermal resources includes: (1) identifying available relevant data and grouping data sets into PFA criteria (e.g., geological, economic, and risk criteria); (2) analyzing data gaps enable future focalized exploration; (3) performing uncertainty quantification; (4) weighting relevant data; (5) developing favorability and common risk maps for low-temperature geothermal resources to identify potential locations for more focused data collection. This project will facilitate future deployment of CHP and GDU by providing data, tools, and a workflow applicable to low-temperature geothermal resources in sedimentary basins.

15 GEOTHERMAL ENERGY↗

Some future applications of low temperature technology in space

Low temperature technology applications are presented for relativity experiments, improved signal to noise ratio performance, and helium studies in space. The large scale, low magnetic field facility is described, as well as the principle of the London moment for relativity gyroscopes.

Fairbank, W. M.↗

Low-Temperature Geothermal Resources: Relevant Data and PFA Methods to Reduce Development Risk

This project is part of a larger national effort focused on demonstrating the multi-faceted value of integrating low-temperature geothermal resources into national decarbonization strategies and community energy plans. Low-temperature geothermal resources are defined as reservoirs-natural or engineered-with temperatures < 150 degrees C. While the focus in the NREL effort is on geothermal heating and cooling (GHC), resources at the upper end of this temperature range can also be used for small-scale power generation. However, low-temperature geothermal resources have not been studied as extensively as higher-temperature geothermal resources. We identified three major classes of low-temperature geothermal play types: sedimentary basins, orogenic systems, and radiogenic systems. We developed workflows for evaluating the potential of these resources building off the Play Fairway Analysis (PFA) approach to de-risking geothermal exploration. This PFA-based approach to low-temperature geothermal resources includes: (1) identifying relevant data; (2) grouping and weighting of relevant datasets into PFA criteria (e.g., geological, risk, economic criteria); (3) developing favorability or common risk maps for low-temperature geothermal resources to identify potential locations for more focused data collection; and (4) estimating electric power generation and heating potential at those locations using the GeoRePORT Resource Size Assessment Tool. This project will facilitate future deployment of GHC by providing data, tools, and workflows applicable to low-temperature geothermal resources.

favorability maps↗

Low Temperature Life-Cycle Testing of a Lithium-Ion Battery for Low-Earth-Orbiting Spacecraft

A flight-qualified, lithium-ion (Li-ion) battery developed for the Mars Surveyor Program 2001 Landeris undergoing life-testing at low temperature under a low-Earth-orbit (LEO) profile to assess its capability to provide long term energy storage for aerospace missions. NASA has embarked upon an ambitious course to return humans to the moon by 2015-2020 in preparation for robotic and human exploration of Mars and robotic exploration of the moons of outer planets. Li-ion batteries are excellent candidates to provide power and energy storage for multiple aspects of these missions due to their high specific energy, high energy density, and excellent low temperature performance. Laboratory testing of Li-ion technology is necessary in order to assess lifetime, characterize multi-cell battery-level performance under aerospace conditions, and to gauge safety aspects of the technology. Life-cycle testing provides an opportunity to examine battery-level performance and the dynamics of individual cells in the stack over the entire life of the battery. Data generated through this testing will be critical to establish confidence in the technology for its widespread use in manned and unmanned missions.

Reid, Concha↗

High Performance SrFe 0.2 Co 0.4 Mo 0.4 O 3–δ Ceramic Anode Supported Low-Temperature SOFCs

The development of alternative ceramic anodes for low-temperature solid oxide fuel cells (LT-SOFCs) is essential to overcome the inherent challenges such as redox instability and coking associated with Ni-based cermet anodes. Moreover, due to the large electrolyte ohmic loss at low temperature, it is critical to developing an electrode supported cell that allows electrolyte thickness reduction. Here we successfully demonstrated a high performance SrFe 0.2 Co 0.4 Mo 0.4 O 3–δ (SFCM) ceramic anode supported LT-SOFC with a peak power density of 730 mW cm –2 and 300 mW cm –2 at ambitious low temperatures of 550 °C and 450 °C, respectively, in humidified H 2 . The new anode material SFCM exhibits exceptional conductivity of over 30 S cm –1 at 450 °C in humidified H 2 , providing essential current collection capability as an anode backbone appropriate for the infiltration of Ni-gadolinia doped ceria (GDC) electrocatalysts. Compared to conventional Ni-cermet anodes, the nano-sized Ni-GDC particles in our SFCM based electrode significantly improves the cell stability in hydrocarbon gases. We demonstrated a stable long-term operation over a period of 380 h in CH 4 –containing gas mixtures at 450 °C with a voltage degradation rate of 4% per 1000 h at a constant current of 0.2 A*cm –2 . Furthermore, our results demonstrate a high performance ceramic anode with high stability for low temperature operation.

25 ENERGY STORAGE↗

Low-Temperature Geothermal Resources: Relevant Data and PFA Methods to Reduce Development Risk: Preprint

This project is part of a larger national effort focused on demonstrating the multi-faceted value of integrating low-temperature geothermal resources into national decarbonization strategies and community energy plans. Low-temperature geothermal resources are defined as reservoirs-natural or engineered-with temperatures < 150 degrees C. While the focus in the NREL effort is on geothermal heating and cooling (GHC), resources at the upper end of this temperature range can also be used for small-scale power generation. However, low-temperature geothermal resources have not been studied as extensively as higher-temperature geothermal resources. We identified three major classes of low-temperature geothermal play types: sedimentary basins, orogenic systems, and radiogenic systems. We developed workflows for evaluating the potential of these resources building off the Play Fairway Analysis (PFA) approach to de-risking geothermal exploration. This PFA-based approach to low-temperature geothermal resources includes: (1) identifying relevant data; (2) grouping and weighting of relevant datasets into PFA criteria (e.g., geological, risk, economic criteria); (3) developing favorability or common risk maps for low-temperature geothermal resources to identify potential locations for more focused data collection; and (4) estimating electric power generation and heating potential at those locations using the GeoRePORT Resource Size Assessment Tool. This project will facilitate future deployment of GHC by providing data, tools, and workflows applicable to low-temperature geothermal resources.

favorability maps↗

Low Temperature Microgravity Physics Facility

The Low Temperature Microgravity Physics Facility (LTMPF) is a state-of-the-art facility for long duration science investigations whose objectives can only be achieved in microgravity and atlow temperature.

microgravity↗

Long Duration Exposure Facility (LDEF) low temperature Heat Pipe Experiment Package (HEPP) flight results

The Low Temperature Heat Pipe Flight Experiment (HEPP) is a fairly complicated thermal control experiment that was designed to evaluate the performance of two different low temperature ethane heat pipes and a low-temperature (182 K) phase change material. A total of 390 days of continuous operation with an axially grooved aluminum fixed conductance heat pipe and an axially grooved stainless steel heat pipe diode was demonstrated before the data acquisition system's batteries lost power. Each heat pipe had approximately 1 watt applied throughout this period. The HEPP was not able to cool below 188.6 K during the mission. As a result, the preprogrammed transport test sequence which initiates when the PCM temperature drops below 180 K was never exercised, and transport tests with both pipes and the diode reverse mode test could not be run in flight. Also, because the melt temperature of the n-heptane PCM is 182 K, its freeze/thaw behavior could not be tested. Post-flight thermal vacuum tests and thermal analyses have indicated that there was an apparent error in the original thermal analyses that led to this unfortunate result. Post-flight tests have demonstrated that the performance of both heat pipes and the PCM has not changed since being fabricated more than 14 years ago. A summary of HEPP's flight data and post-flight test results are presented.

Mcintosh, Roy↗

Exploring pH Dynamics in Amino Acid Solutions Under Low-Temperature Plasma Exposure

Low-temperature plasma (LTP) offers a promising alternative for cancer therapy, as it targets malignant cells selectively while minimizing damage to healthy tissues. Upon interaction with an aqueous solution, LTP generates reactive oxygen and nitrogen species and thereby influences the solution’s pH, which is a crucial factor in cancer proliferation and response to treatment. This study investigated the effects of LTP on the pH of aqueous solutions, with a focus on the effect of LTP parameters such as voltage, frequency, and irradiation time. In addition, it explored the influence of solution composition, specifically the presence of the amino acids, glycine and serine, on pH changes; these amino acids are known to play significant roles in cancer proliferation. Our results indicated that LTP induces acidification in deionized water, in which the extent of acidification increased proportionally with plasma parameters. In glycine-containing solutions, pH changes were concentration-dependent, whereas serine-containing solutions maintained a constant pH across all tested concentrations. To investigate potential changes to the structural properties of glycine and serine exposed to LTP that could be responsible for different pH responses, we analyzed the samples using FTIR spectroscopy. A significant decrease in absorbance was observed for solutions with low concentrations of amino acids, suggesting their degradation.

Biochemistry & Molecular Biology↗

Influence of trace level As or Ni on pyrite formation kinetics at low temperature

Pyrite formation at low temperature during early diagenesis in (sub-)surface sediments is an essential step of Fe and S biogeochemical cycles and the presence of this ubiquitous mineral of surface environments is often used as an indicator of paleo-redox conditions. Pathways of pyrite formation are usually discussed in environmental settings by involving a variety of nanosized Fe-S mineralogical precursors as a function of the local geochemical conditions. However, the influence of trace element impurities such as Ni and As in the solution at the time of pyrite formation has been poorly studied, whereas specific chemical signatures of trace elements are commonly observed in sedimentary pyrites. Here, a better understanding of the impact of Ni and As incorporation at trace levels on pyrite formation is essential to help refining the use of these elements as paleo-redox indicators and to evaluate the role of pyrite as a sink regulating the biogeochemical cycle of potentially toxic trace elements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pulsed power to control growth of silicon nanoparticles in low temperature flowing plasmas

Low-temperature plasmas have seen increasing use for synthesizing high-quality, mono-disperse nanoparticles (NPs). Recent work has highlighted that an important process in NP growth in plasmas is particle trapping—small, negatively charged nanoparticles become trapped by the positive electrostatic potential in the plasma, even if only momentarily charged. In this article, results are discussed from a computational investigation into how pulsing the power applied to an inductively coupled plasma (ICP) reactor may be used for controlling the size of NPs synthesized in the plasma. The model system is an ICP at 1 Torr to grow silicon NPs from an Ar/SiH 4 gas mixture. This system was simulated using a two-dimensional plasma hydrodynamics model coupled to a three-dimensional kinetic NP growth and trajectory tracking model. The effects of pulse frequency and pulse duty cycle are discussed. We identified separate regimes of pulsing where particles become trapped for one pulsed cycle, a few cycles, and many cycles—each having noticeable effects on particle size distributions. For the same average power, pulsing can produce a stronger trapping potential for particles when compared to continuous wave power, potentially increasing particle mono-dispersity. Pulsing may also offer a larger degree of control over particle size for the same average power. Experimental confirmation of predicted trends is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electronics for Low-Temperature Space Operation Being Evaluated

Electronic components and systems capable of low-temperature operation are needed for many future NASA missions where it is desirable to have smaller, lighter, and cheaper (unheated) spacecraft. These missions include Mars (-20 to -120 C) orbiters, landers, and rovers; Europa (-150 C) oceanic exploratory probes and instrumentation; Saturn (-183 C) and Pluto (-229 C) interplanetary probes. At the present, most electronic equipment can operate down to only -55 C. It would be very desirable to have electronic components that expand the operating temperature range down to -233 C. The successful development of these low-temperature components will eventually allow space probes and onboard electronics to operate in very cold environments (out as far as the planet Pluto). As a result, radioisotope heating units, which are used presently to keep space electronics near room temperature, will be reduced in number or eliminated. The new cold electronics will make spacecraft design and operation simpler, more flexible, more reliable, lighter, and cheaper. Researchers at the NASA Glenn Research Center are evaluating potential commercial off-the- shelf devices and are developing new electronic components that will tolerate operation at low temperatures down to -233 C. This work is being carried out mainly inhouse and also through university grants and commercial contracts. The components include analog-to-digital converters, semiconductor switches, capacitors, dielectric and packaging material, and batteries. For example, the effect of low temperature on the capacitance of three different types of capacitors is shown in the graph. Using these advanced components, system products will be developed, including dc/dc converters, battery charge/discharge management systems, digital control electronics, transducers, and sensor instrumentation.

Patterson, Richard L.↗

Low Temperature Microcalorimeters for Decay Energy Spectroscopy

Low Temperature Detectors have been used to measure embedded radioisotopes in a measurement mode known as Decay Energy Spectroscopy (DES) since 1992. DES microcalorimeter measurements have been used for applications ranging from neutrino mass measurements to metrology to measurements for safeguards and medical nuclides. While the low temperature detectors have extremely high intrinsic energy resolution (several times better than semiconductor detectors), the energy resolution achieved in practice is strongly dependent on factors such as sample preparation method. This review seeks to present the literature consensus on what has been learned by looking at the energy resolution as a function of various choices of detector, absorber, and sample preparation methods.

47 OTHER INSTRUMENTATION↗