Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lost load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Electrolytic pretreatment unit gaseous effluent conditioning

The electrolytic pretreatment of urine is an advanced process that eliminates the need for handling and storing the highly corrosive chemicals that are normally used in water reclamation systems. The electrolytic pretreatment process also converts the organic materials in urine to gases (N2 and O2) that can be used to replenish those lost to space by leakage, venting, and air lock operations. The electrolytic process is more than a pretreatment, since it decreases the urine solids content by approximately one third, thus reducing the load and eventual solids storage requirements of the urine processing system. The evolved gases from the pretreatment step cannot, however, be returned directly to the atmosphere of a spacecraft without first removing several impurities including hydrogen, chlorine, and certain organic compounds. A treatment concept was developed that would decrease the impurities in the gas stream that emanates from an electrolysis unit to levels sufficiently low to allow the conditioned gas stream to be safely discharged to a spacecraft atmosphere. Two methods were experimentally demonstrated that can accomplish the desired cleanup. The bases of the two methods are, repectively: (1) raw urine scrubbing and (2) silica gel sorption.

Colombo, G. V.↗

Tactility as a function of grasp force: Effects of glove, orientation, pressure, load, and handle

One of the reasons for reduction in performance when gloves are donned is the lack of tactile sensitivity. It was argued that grasping force for a weight to be grasped will be a function of the weight to be lifted and the hand conditions. It was further reasoned that the differences in grasping force for various hand conditions will be a correlate of the tactile sensitivity of the corresponding hand conditions. The objective of this experiment, therefore, was to determine the effects of glove type, pressure, and weight of load on the initial grasping force and stable grasping force. It was hypothesized that when a person grasps an object, he/she grasps very firmly initially and then releases the grasp slightly after realizing what force is needed to maintain a steady grasp. This would seem to be particularly true when a person is wearing a glove and has lost some tactile sensitivity and force feedback during the grasp. Therefore, the ratio of initial force and stable force and the stable force itself would represent the amount of tactile adjustment that is made when picking up an object, and this adjustment should vary with the use of gloves. A dynamometer was fabricated to measure the grasping force; the tests were performed inside a glove box. Four female and four male subjects participated in the study, which measured the effects of four variables: load effect, gender effect, glove type, and pressure variance. The only significant effects on the peak and stable force were caused by gender and the weight of the load lifted. Neither gloves nor pressure altered these forces when compared to a bare-handed condition, as was suspected before the test. It is possible that gloves facilitate in holding due to coefficient of friction while they deter in peak grasp strength.

Bishu, Ram R.↗

Outgassing Characterization of Common Trash Items for Disposal By Nanoracks Airlock on the International Space Station

The arrival of the Nanoracks Airlock to the International Space Station (ISS) has provided the ISS program the capability to dispose of common trash items. The concept of operations involved the crew bagging up those items into a trash bag and then utilizing the robotic arm and the airlock to jettison the trash bag. Because of the unknown thermal vacuum stability of some of the items, a molecular contamination concern was raised by the ISS program as the trash is exposed to vacuum upon the evacuation of air from the airlock and the robotic arm moving the airlock to its jettison location. In order to characterize the representative outgassing rates for ISS trash, thermal vacuum testing was performed at White Sands Test Facility. Trash was sorted into a “lower” outgassing bag and a “mixed” bag. The “mixed” trash bag contained more items that were suspected to be not vacuum stable. Load cells were chosen as the primary means for measuring mass loss. A sharp decay in the outgassing rate was observed in the first 30 minutes followed by a slower decay. As expected, the “mixed” bag lost more mass. While Quartz Crystal Microbalances (QCMs) are often utilized to measure long term outgassing rates and the sticking coefficients of contaminants at different operating temperatures for vacuum stable materials, these measurements proved difficult due to the amount and the inclusion of materials with suspect thermal vacuum stability. Because of high rates of material outgassing, the facility was unable to maintain the CQCM temperature setpoint of 80 K QCMs.. The QCMs operating at the warmer temperatures also saturated on occasion due to high levels of condensed matter. Though testing was able to confirm high risk of outgassing contamination for the program, true sticking coefficients could not be determined, available measurements are provided herein.

Alvin Y Huang↗

Bayesian phylogeny of sucrose transporters: ancient origins, differential expansion and convergent evolution in monocots and dicots

Sucrose transporters (SUTs) are essential for the export and efficient movement of sucrose from source leaves to sink organs in plants. The angiosperm SUT family was previously classified into three or four distinct groups, Types I, II (subgroup IIB), and III, with dicot-specific Type I and monocot-specific Type IIB functioning in phloem loading. To shed light on the underlying drivers of SUT evolution, Bayesian phylogenetic inference was undertaken using 41 sequenced plant genomes, including seven basal lineages at key evolutionary junctures. Our analysis supports four phylogenetically and structurally distinct SUT subfamilies, originating from two ancient groups (AG1 and AG2) that diverged early during terrestrial colonization. In both AG1 and AG2, multiple intron acquisition events in the progenitor vascular plant established the gene structures of modern SUTs. Tonoplastic Type III and plasmalemmal Type II represent evolutionarily conserved descendants of AG1 and AG2, respectively. Type I and Type IIB were previously thought to evolve after the dicot-monocot split. We show, however, that divergence of Type I from Type III SUT predated basal angiosperms, likely associated with evolution of vascular cambium and phloem transport. Type I SUT was subsequently lost in monocots along with vascular cambium, and independent evolution of Type IIB coincided with modified monocot vasculature. Both Type I and Type IIB underwent lineage-specific expansion. In multiple unrelated taxa, the newly-derived SUTs exhibit biased expression in reproductive tissues, suggesting a functional link between phloem loading and reproductive fitness. Convergent evolution of Type land Type IIB for SUT function in phloem loading and reproductive organs supports the idea that differential vascular development in dicots and monocots is a strong driver for SUT family evolution in angiosperms.

59 BASIC BIOLOGICAL SCIENCES↗

Corroborating VNA and thermal measurements of transmission loss on the DIII-D ECH waveguide system

Electron cyclotron heating (ECH) and current drive (ECCD) will play a large role in tokamak-based fusion reactors. At the DIII-D tokamak, 110 GHz microwaves injected into the plasma can provide core heating and current drive as well as impurity control, neoclassical tearing mode mitigation, and breakdown assistance. Understanding the physics of these processes relies on accurate estimates of injected ECH power. DIII-D’s ECH system consists of six MW-class Microwave Power Products (MPP) gyrotron microwave sources. Operating the gyrotrons far from the tokamak removes them from magnetic field interference, so 31.75 mm inner-diameter corrugated waveguides transmit the microwave power the 80 m from the gyrotrons to steerable launchers in the tokamak chamber. Estimates of injected power rely on knowing the generated power at the source and then subtracting transmission loss. Conventional transmission loss measurements based on calorimetric dummy loads are onerous and only possible during extended maintenance periods. This work examines two tools that provide more flexibility for the transmission loss measurements. Furthermore, a resistive temperature detector (RTD) array installed along a waveguide measures heat lost to the transmission line, and low power time domain reflectometry (TDR) measurements with a vector network analyzer (VNA) allows loss measurements without burdensome hardware modifications.

ECH↗

Operating displays - new concept: high performance displays - 118

New control rooms in Nuclear Power Plants using digital Distributed Control System (DCS) operated with software displays, are providing thousands of signals to the operating crew. When an event happens, the Flood of information provided to operators could obscure the initiator event increasing the operator response time, work load and complicating the selection of the actions to be performed. There are some initiatives that are trying to minimize the 'avalanche effect' as the alarm engineering filtering and prioritization or diagnostic displays. Likewise, new control rooms are lost the availability to know the plant status just with a quick glance to the panel indicators. Regarding Small Modular Reactors, where in some cases four operators should monitor and control twelve reactors, these problems are even more significant. The challenge is to find a solution, based on current digital systems, that supply information to operators in order to prevent events and take early actions to minimize or avoid any unexpected incident. In order to minimize human errors, Tecnatom has developed a specific set of displays, called 'High Performance Displays' (HPD) based on objectives, work environment limitation, and non-anticipated events. These displays are being design following the HFE standards: applying the NUREG-0711 elements to identify the information that they have to content and the NUREG-0700 to design the interface. The function of these displays is monitoring the plant situation in a way that the operators are able to recognize any potential event at a simple glance but controlling thousands of signals through pattern recognition, symmetries, regular polygons and colors. The objective of the HPD is to provide an integrated function minimizing the tunnel effect and reduce the workload during the diagnosis phase. Moreover, HPD enhance operators to take the right actions to anticipate the response to any event, even avoiding it, if possible This paper analyzes how HPD's have been design as well as presents the results of a preliminary validation of their capabilities. The preliminary validation is a reduce validation in a full scope simulator running two representative scenarios of abnormal and emergency operation. The analysis is focused on the first stage of the event, i.e. the detection phase, HPD's have been installed in a generic full scope simulator of a nuclear power plant, digital controlled. Both scenarios have been performed by two different operator crews. The first operator shift has worked with the conventional human machine interface, that is, displays similar to the ones currently installed in existing nuclear power plant with digital control. The second crew, reproduce the same scenarios but with HPD available. The studio collects preliminary data in order to compare results, draw lesson learned from the experience to improve HPD design, and find solutions in terms of reducing human errors, human workload, and increase the availability of the plant. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Co-optimization of nuclear reactor flexible power operation and maintenance scheduling

As flexible power operation of nuclear power plants becomes more attractive due to the reduction in fossil-fueled dispatchable generation on energy grids, finding optimal power production strategies that balance revenue generation with operational concerns becomes more complex. This article presents a general framework to aid operators in designing economically optimal long term dispatch strategies for nuclear power plants. The principal novelty is the linking of estimated system remaining useable life (RUL) to strategic operational decisions. It is shown that, depending on the relationship between the fixed costs from maintenance and the associated lost revenue from an outage, it can be economically optimal in the long term to delay a maintenance outage and not perform this alongside refueling. For a given relationship between power ramping and degradation, optimal strategies were found that discouraged load following in some situations while minimizing unnecessary maintenance. It is shown that heavy load following can cause maintenance and refueling outages to diverge due to their inverse relationships with respect to load following, potentially leading to a significant loss in capacity factor. As a result, this general framework can be applied to specific reactor dispatch allowing operators to adapt operational strategies as future grid conditions change.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Stability of Atomically Dispersed Fe–N–C ORR Catalyst in Polymer Electrolyte Fuel Cell Environment

We have investigated the durability of a platinum group metal (PGM-)free Fe–N–C catalyst in which the Fe sites are atomically dispersed (AD), and found it to be quite stable in standard accelerated stress test (AST) cycles normally used for low-PGM catalysts: a square wave with 0.6 V lower potential limit (LPL)—0.95 V upper potential limit (UPL) with 3-s holds at UPL and LPL in H 2 /N 2 , at 1.5 atm, 80 °C and 100% RH. Considering the metrics normally employed to characterize the durability of the low-PGM catalysts after 30,000 AST cycles, this PGM-free catalyst lost <50% catalyst activity, <50% H 2 /air performance at 0.8 V, and 40 mV at 1.5 A cm -2 . However, it is less stable in H 2 /air, losing ~50% catalyst activity after just 7.5 h of polarization measurements (load cycles). In combined cycles, the majority of the loss in catalyst activity occurred during the load cycles in H 2 /air rather than AST cycles in H 2 /N 2 . We have concluded that, unlike low-PGM catalysts that lose electrochemically active surface area (ECSA) through potential cycling-induced processes, (AD)Fe–N–C catalysts degrade by processes associated with the presence of oxygen.

25 ENERGY STORAGE↗

Energetic oxygen and sulfur ions in the Jovian magnetosphere

Observations of 1 to 20 MeV/nuc oxygen, sodium, and sulfur ions in the Jovian magnetosphere are reported. Measurements made by the cosmic ray subsystem on Voyager 1 and 2 were used to calculate abundances and energy spectra in the region from 5 to 20 Jovian radii. The phase space density of the oxygen ions calculated from the spectra has a positive radial gradient between 6 and 17 Jovian radii, indicating an inward diffusive flow. The diffusion coefficient upper limit at 9 Jovian radii is approximately 10 to the -5 power/s. This limit, combined with the analysis of Voyager plasma observations by Siscoe et al.1981, implies an upper limit to the mass loading rate near Io of approximately 10 to the 28th power ions/s. The energetic oxygen lifetime is within an order of magnitude of the strong pitch-angle diffusion lifetime in this region, with the largest total number of particles lost between 7.5 and 12.5 Jovian radii. It is shown that the losses are not due to geometric absorption by Io, absorption by dust grains, or energy loss in the plasma of the inner magnetosphere, and it is therefore postulated that the primary loss mechanism is pitch-angle scattering into the loss cone.

Gehrels, N.↗

VersiCharge-SG - Smart Grid Capable Electric Vehicle Supply Equipment (EVSE) for Residential Applications

In his 2011 State of the Union address, President Obama called for one million electric vehicles on the road by 2015 [1]. With large-scale Electric Vehicle (EV) or Plug-in Electric Vehicle (PEV or EV for short) or Plug-in Hybrid Electric Vehicle (PHEV) penetration into the US market, there will be drastic reduction in fossil fuel consumption, thus significantly reducing our dependency on foreign oil [2-6]. There will also be significant reduction on Green House Gas (GHG) emissions and smog in the major US cities [3, 7, 8]. Similar studies have also been done other industrial counties [9]. For the fuel cost, with the home electricity rate around $0.13 per kWh, it would cost about $0.05 per mile for DC operation and $0.03 cents per mile for AC operation. But, assuming 25 miles per gallon for a typical vehicle and $4 per gallon, fossil fuel will cost $0.16 per mile [10]. The overall lifecycle cost of PEVs will be several folds lower than the existing fossil fueled vehicles. Despite the above advantages of the EVs, the current cost of EVSE is not affordable for the average consumer. Presently, the cost of installing state-of-the-art residential EVSE ranges from $1500 to $2500 [11]. Low priced EVSE technology, which is easy to install, and affordable to operate and maintain by an average consumer, is essential for the large-scale market penetration of EVs. In addition, the long-term success of this technology is contingent on the PEVs having minimal excessive load and shift impact on the grid, especially at peak times. In a report [2] published by the Pacific Northwest National Laboratory (PNNL), the exiting electric power generation infrastructure, if used at its full capacity 24 hours a day, would support up to 84% of the nation’s cars, pickup trucks and SUVs for an average daily drive of 33 miles. This mileage estimate is certainly much below what an average driver would drive his/her vehicle per day. Another report [3] by the National Renewable Energy Laboratory (NREL) shows that an increased PEV penetration would significantly increase pressure on the peak generation, if no controlled charging strategy was put in place. Investigations from Oak Ridge National Laboratory (ORNL) show that in many regions, additional power generation facilities must be put in place and operate in evening times to recharge the EVs [12]. By all accounts, large PEV penetration will bring to the power grid enormous challenges due to the excessive and stochastic demand, and can entirely change the peak time distribution and behavior, perhaps, into a bi-modal distribution capable of exhausting primary, secondary and even reserves (spinning or non-spinning). To minimize the infrastructure upgrade costs and risks to the grid, and to ensure that power quality and reliability remain within the set standards, the demand for EV plug-ins must then be controlled and coordinated locally and at regional levels. Novel control techniques must be devised to allow for close collaboration between neighboring plug-in requestors, between neighboring communities, and between these and more central power authorities. The concept of electric drive vehicle is not new. The development of electric vehicle has been around since 19th century [13]. But due to a number of reasons and practical limitations at the time, including lower cost of gasoline compared to electricity, excessive refueling times, and abundance of gasoline, the automobile industry embraced gasoline-powered vehicles worldwide [13]. With the global warming, ever reducing reservoirs of fossil oil around the world and increasing political pressure to reduce the national dependency on foreign oil, the last decade of the 20th century witnessed major technological breakthroughs in Alternative Fueled Vehicle (AFV) technologies, including electric vehicles. With GHG emissions and carbon footprint in the minds of many more consumers and politicians, the first decade of the 21stCentury witnessed more breakthroughs with some real life experimentation and sporadic deployment of these technologies [14]. By many accounts, the second decade of the 21st Century is expected to be the time when mass volume production and popular usage of these AFV technologies, especially EV, will materialize. The current DOE request for proposals recognizes the need for major technological changes to ensure that the above national goal is realizable. Two major challenges have been identified: (1) major reduction in the cost of ownership of EVSEs, and (2) managing additional EV loads in the power grid while maintaining power quality, reliability, and affordability. We note that the two challenges are closely linked – A holistic approach to true lifecycle cost of EVSE ownership will certainly include any taxes and surcharges that can be put in place for major potential investments in the grid, and higher electricity charges in case of more frequent and longer peak periods. From a societal perspective, this cost could also include the lost GDP (computed on a local basis) and revenue for businesses at local and regional levels when the grid is no longer capable of meeting the demand and unexpected outages occur. A typical end-point electrical distribution system delivers power to a residential EVSE from the neighborhood distribution pole, as shown in Fig.1. This pole has a transformer (neighboring step-down transformer) that steps down the utility medium voltage to dual 120VAC single phase (also called 240VAC split phase). This voltage is fed through a meter into the residential load control center. The load control center consists of branch circuit breakers and distributes the power supply within various areas of the residential unit. One of the branch circuits from the load control center feeds EV charging station for the unit. An electric vehicle charger is plugged into the socket of the EV charging station and other end of this charger is connected to the vehicle during charging. Figure 1 illustrates a typical configuration of the power grid. The left side of the figure shows the power grid from the power generation to the neighboring step-down transformer, while the right side of the figure shows multiple EVs with the respective charging stations. The typical step-down transformer has an upper limit representing the maximum load that can be requested from these neighboring houses altogether (typically 24 kW). In case the total load increases beyond the supported limit, the protection system (e.g. a circuit breaker) attached to the step-down transformer gets activated automatically.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Catalyst-Specific Accelerated Stress Tests in Proton Exchange Membrane Low-Temperature Electrolysis for Intermittent Operation

Device-level stress tests are developed that focus on anode catalyst layer degradation and future anticipated operating conditions, including intermittent load and reduced platinum group metal content. Square-wave cycles with an upper load limit of 2.5 A cm -2 are utilized to screen commercial iridium (Ir) materials. Performance losses are primarily due to decreasing kinetics and are accompanied by catalyst migration into the membrane, worsening catalyst/ionomer integration, and weakening of the catalyst/membrane interface. For ruthenium-containing catalysts, the in situ performances are higher but durabilities lower than Ir baselines, and any performance advantage is lost within the test. Increased loss is likely due to the higher dissolution rate; microscopy confirmed greater degrees of ruthenium migration. For Ir metal or mixed oxides, ex situ activity improvements generally did not translate to in situ performance. The durability, however, is significantly lower and the loss rate increased from 3 (oxide) to 9 (metal) μ V cycle -1 . These results are consistent with historical findings in literature, rationalize the continued use of iridium oxide as a baseline catalyst, and demonstrate that traditional catalyst development approaches may not improve device-level durability when focused on low-cost applications. A shift in focus may therefore be more effective at improving catalyst utilization and lessening load requirements.

08 HYDROGEN↗

Achieving SEI preformed graphite in flow cell to mitigate initial lithium loss

The irreversible lithium loss due to the formation of solid electrolyte interphase (SEI) in the initial cycle on the graphite anode greatly reduces the overall cell energy density of lithium ion batteries, that is, the lost Li ions from forming SEI lead to the decrease of Li ions for the intercalation. The method of cathode prelithiation has been widely explored to compensate this lithium loss. However, these cathode additives with high lithium contents inevitably lower the loading of the cathode active materials. In this work, we report a novel approach to solve this challenge, a facile graphite prelithiation method by preforming SEI layers on the surface of graphite powders (Pre-SEI graphite) utilizing a specially designed flow cell. The Li accommodation in the graphite anode can be controlled by the operating time and current density in the flow cell for the electrochemical SEI formation. As a result, we demonstrate a 10% initial Columbic efficiency increase of the LiFePO 4 electrode in a full cell configuration using the Pre-SEI graphite, compared with the pristine graphite anode. The electrochemical preformation of SEI on the graphite powders offers a complete solution to offset initial lithium loss without a sacrifice of active cathode material loading.

25 ENERGY STORAGE↗

Conceptual design of the ITER fast-ion loss detector

A conceptual design of a reciprocating fast-ion loss detector for ITER has been developed and is presented here. Fast-ion orbit simulations in a 3D magnetic equilibrium and up-to-date first wall have been carried out to revise the measurement requirements for the lost alpha monitor in ITER. In agreement with recent observations, the simulations presented here suggest that a pitch-angle resolution of ∼5° might be necessary to identify the loss mechanisms. Synthetic measurements including realistic lost alpha-particle as well as neutron and gamma fluxes predict scintillator signal-to-noise levels measurable with standard light acquisition systems with the detector aperture at ∼11 cm outside of the diagnostic first wall. At measurement position, heat load on detector head is comparable to that in present devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Global Barotropic Tide Modeling Using Inline Self‐Attraction and Loading in MPAS‐Ocean

Abstract We examine ocean tides in the barotropic version of the Model for Prediction Across Scales (MPAS‐Ocean), the ocean component of the Department of Energy Earth system model. We focus on four factors that affect tidal accuracy: self‐attraction and loading (SAL), model resolution, details of the underlying bathymetry, and parameterized topographic wave drag. The SAL term accounts for the tidal loading of Earth's crust and the self‐gravitation of the ocean and the load‐deformed Earth. A common method for calculating SAL is to decompose mass anomalies into their spherical harmonic constituents. Here, we compare a scalar SAL approximation versus an inline SAL using a fast spherical harmonic transform package. Wave drag accounts for energy lost by breaking internal tides that are produced by barotropic tidal flow over topographic features. We compare a series of successively finer quasi‐uniform resolution meshes (62.9, 31.5, 15.7, and 7.87 km) to a variable resolution (45 to 5 km) configuration. We ran MPAS‐Ocean in a single‐layer barotropic mode forced by five tidal constituents. The 45 to 5 km variable resolution mesh obtained the best total root‐mean‐square error (5.4 cm) for the deep ocean ( 1,000 m) tide compared to TPXO8 and ran twice as fast as the quasi‐uniform 8 km mesh, which had an error of 5.8 cm. This error is comparable to those found in other forward (non‐assimilative) ocean tide models. In future work, we plan to use MPAS‐Ocean to study tidal interactions with other Earth system components, and the tidal response to climate change.

54 ENVIRONMENTAL SCIENCES↗

Rotor-Stator Interaction Performance Effects

Decreased axial spacing between blade rows in an axial compressor stage is thought to increase stage performance because of an unsteady process that occurs in the downstream blade row and acts on the upstream blade row wakes. This process results in the "recovery" of part of the wake energy before all of this energy is irreversibly lost due to viscous diffusion. To study the wake-blade interaction mechanism, researchers at the NASA Lewis Research Center acquired two-component Laser Fringe Anemometer measurements of the rotor wake in the single-stage transonic compressor at two stage loading levels. The detailed measurements were acquired for one stator pitch in circumference at axial positions from the rotor trailing edge to 20 percent of the stator axial chord, at the exit of the stator passage, and downstream of the stator row including the stator wake. These data show that the changes in wake energy that occur inside the stator passage are not due to viscous dissipation alone, and thus the data provide evidence that "wake recovery" is occurring. A time-accurate, three-dimensional Navier Stokes simulation of the compressor stator was done at the corresponding stage loading levels. The measurements and simulations are being used in combination to show the effects of stator blade loading, quantify the effects of viscosity, and quantify the stage efficiency gain due to the wake recovery process. The accuracy of simple models of the wake recovery process is being evaluated in an effort to include the effects of wake recovery in the NASA-developed Average Passage code for multistage turbomachinery simulations.

VanZante, Dale E.↗

Distributed Cooperative Control of Wind Farms with On-Site Battery Energy Storage Systems

This chapter studies the output power regulation in wind farms consisting of doubly-fed induction generator wind turbines, one of the most popular generator configurations in modern multi-MW wind industry, equipped with on-site battery energy storage systems. Traditionally, wind farms were operated as standalone units or were equipped with a central, large-scale, energy storage system. In fact, most of the existing control designs for hybrid wind-storage applications are centralized, where the central unit collects the measured data from all wind turbines and storage systems (if they exist) and compares with the load demand to generate the reference power for each wind turbine controller. Those centralized setups or control structures do not fully exploit the flexibility and locality of the on-site energy storage systems in a wind farm. Moreover, the storage functionality is lost if the central storage system is broken down, while in a distributed architecture, a failure only affects individual on-site storage systems and the others will still operate. Therefore, on-site storage systems and distributed control designs need to be developed for wind farms to provide regulation services for the grid. An approach to tackle that challenge will be presented in this chapter.

17 WIND ENERGY↗

Modifications to Marshall's Annular Seal Test (MAST) Rig and Facility for Improved Rotordynamic Coefficient Testing of Annular Seals and Fluid Film Bearings

The limits of rotordynamic stability continue to be pushed by the high power densities and rotational speeds of modern rocket engine turbomachinery. Destabilizing forces increase dramatically with rotor speed. Rotordynamic stability is lost when these destabilizing forces overwhelm the stabilizing forces. The vibration from the unstable rotor grows until it is limited by some nonlinearity. For example, a rolling element bearing with a stiffness characteristic that increases with deflection may limit the vibration amplitude. The loads and deflections resulting from this limit cycle vibration (LCV) can lead to bearing and seal damage which promotes ever increasing levels of subsynchronous vibration. Engineers combat LCV by introducing rotordynamic elements that generate increased stabilizing forces and reduced destabilizing forces. For example, replacing a labyrinth seal with a damping seal results in substantial increases in the damping and stiffness rotordynamic coefficients. Adding a swirl brake to the damping seal greatly reduces the destabilizing cross-coupled forces generated by the damping seal for even further increases in the stabilizing capacity. Marshall?s Annular Seal Test (MAST) rig is designed to experimentally measure the stabilizing capacity of new annular seal designs. The rig has been moved to a new facility and outfitted with a new slave bearing to allow increased test durations and to enable the testing of fluid film bearings. The purpose of this paper is to describe the new facility and the new bearing arrangement. Several novel seal and bearing designs will also be discussed.

Darden, J. M.↗

Powerloads on the front end components and the duct of the heating and diagnostic neutral beam lines at ITER

The heating and current drive beam lines (HNB) at ITER are expected to deliver ∼16.7 MW power per beam line for H beams at 870 keV and D beams at 1 MeV during the H-He and the DD/DT phases of ITER operation respectively. On the other hand the diagnostic neutral beam (DNB) line shall deliver ∼2 MW power for H beams at 100 keV during both the phases. The path lengths over which the beams from the HNB and DNB beam lines need to be transported are 25.6 m and 20.7 m respectively. The transport of the beams over these path lengths results in beam losses, mainly by the direct interception of the beam with the beam line components and reionisation. The lost power is deposited on the surfaces of the various components of the beam line. In order to ensure the survival of these components over the operational life time of ITER, it is important to determine to the best possible extent the operational power loads and power densities on the various surfaces which are impacted by the beam in one way or the other during its transport. The main factors contributing to these are the divergence of the beamlets and the halo fraction in the beam, the beam aiming, the horizontal and vertical misalignment of the beam, and the gas profile along the beam path, which determines the re-ionisation loss, and the re-ionisation cross sections. The estimations have been made using a combination of the modified version of the Monte Carlo Gas Flow code (MCGF) and the BTR code. The MCGF is used to determine the gas profile in the beam line and takes into account the active gas feed into the ion source and neutraliser, the HNB-DNB cross over, the gas entering the beamline from the ITER machine, the additional gas atoms generated in the beam line due to impacting ions and the pumping speed of the cryopumps. The BTR code has been used to obtain the power loads and the power densities on the various surfaces of the front end components and the duct modules for different scenarios of ITER operation. The gas profile and the magnetic field distribution for each scenario has been considered in these evaluations. The worst case power loads and power densities for each surface have been used to study their thermo-mechanical behaviour and manufacturing feasibility. The details of these calculations and results obtained are presented and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗