Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loss”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

An off-design correlation of part span damper losses through transonic axial fan rotors

The experimental performance of 10 transonic fan rotors was used to correlate losses caused by midchord part-span dampers (PSD) during off-design operation between 50 and 100 percent of design speed. The design tip speed for the rotors used varied from 419 to 425 m/s and the design pressure ratios from 1.6 to 2.0. The loss attributable to the damper and the region influenced along the blade height was correlated with relevant aerodynamic and geometric parameters. The losses at the design point were estimated by a previously reported correlation (Roberts, 1978). Using this as a base, the off-design losses were correlated with variation in blade suction surface incidence. A check with independent data showed that the prediction of damper losses and region of influence was fair to good for most of the off-design data examined.

Roberts, W. B.↗

Feasibility of determining flat roof heat losses using aerial thermography

The utility of aerial thermography for determining rooftop heat losses is investigated. Actual rooftop heat losses were obtained both from in-situ instrumentation of test roofs with known thermal resistances and aerial thermography obtained from overflights at an altitude of 305 m. It is found that the roof heat losses calculated using the remotely determined roof temperature agreed to within 17% of those calculated from ground measurements. However it is noted that an acceptable quantitative determination of roof heat losses using aerial thermography is only feasible when the convective term is accurately known or minimized. In addition, the sensitivity of the heat loss determination to environmental conditions is also evaluated. Finally, the analysis shows that the most reliable determinations can probably be obtained under conditions of total cloud cover with low wind speeds and at low ambient temperatures.

Bowman, R. L.↗

Effect of geometry and operating conditions on spur gear system power loss

The results of an analysis of the effects of spur gear size, pitch, width, and ratio on total mesh power loss for a wide range of speeds, torques, and oil viscosities are presented. The analysis uses simple algebraic expressions to determine gear sliding, rolling, and windage losses and also incorporates an approximate ball bearing power loss expression. The analysis shows good agreement with published data. Large diameter and fine pitched gears had higher peak efficiencies but low part load efficiency. Gear efficiencies were generally greater than 98 percent except at very low torque levels. Tare (no-load) losses are generally a significant percentage of the full load loss except at low speeds.

Anderson, N. E.↗

Loss model for off-design performance analysis of radial turbines with pivoting-vane, variable-area stators

An off-design performance loss model is developed for variable-area (pivoted vane) radial turbines. The variation in stator loss with stator area is determined by a viscous loss model while the variation in rotor loss due to stator area variation (for no stator end-clearance gap) is determined through analytical matching of experimental data. An incidence loss model is also based on matching of the experimental data. A stator vane end-clearance leakage model is developed and sample calculations are made to show the predicted effects of stator vane end-clearance leakage on performance.

Meitner, P. L.↗

Effect of geometry and operating conditions on spur gear system power loss

The results of an analysis of the effects of spur gear size, pitch, width and ratio on total mesh power loss for a wide range of speeds, torques and oil viscosities are presented. The analysis uses simple algebraic expressions to determine gear sliding, rolling and windage losses and also incorporates an approximate ball bearing power loss expression. The analysis shows good agreement with published data. Large diameter and fine-pitched gears had higher peak efficiencies but lower part-load efficiency. Gear efficiencies were generally greater than 98 percent except at very low torque levels. Tare (no-load) losses are generally a significant percentage of the full-load loss except at low speeds.

Anderson, N. E.↗

Off-design performance loss model for radial turbines with pivoting, variable-area stators

An off-design performance loss model was developed for variable stator (pivoted vane), radial turbines through analytical modeling and experimental data analysis. Stator loss is determined by a viscous loss model; stator vane end-clearance leakage effects are determined by a clearance flow model. Rotor loss coefficient were obtained by analyzing the experimental data from a turbine rotor previously tested with six stators having throat areas from 20 to 144 percent of design area and were correlated with stator-to-rotor throat area ratio. An incidence loss model was selected to obtain best agreement with experimental results. Predicted turbine performance is compared with experimental results for the design rotor as well as with results for extended and cutback versions of the rotor. Sample calculations were made to show the effects of stator vane end-clearance leakage.

Meitner, P. L.↗

Determination of efficiencies, loss mechanisms, and performance degradation factors in chopper controlled dc vehical motors. Section 1: Test program results and recommendations

The conventional series motor model is discussed as well as procedures for obtaining, by test, the parameters necessary for calculating performance and losses. The calculated results for operation from ripple free DC are compared with observed test results, indicating approximately 5% or less error. Experimental data indicating the influence of brush shift and chopper frequency are also presented. Both factors have a significant effect on the speed and torque relationships. The losses and loss mechanisms present in a DC series motor are examined and an attempt is made to evaluate the added losses due to harmonic currents and fluxes. Findings with respect to these losses is summarized.

Hamilton, H. B.↗

Loss model for off-design performance analysis of radial turbines with pivoting-vane, variable-area stators

An off-design performance loss model for a radial turbine with pivoting, variable-area stators is developed through a combination of analytical modeling and experimental data analysis. A viscous loss model is used for the variation in stator loss with setting angle, and stator vane end-clearance leakage effects are predicted by a clearance flow model. The variation of rotor loss coefficient with stator setting angle is obtained by means of an analytical matching of experimental data for a rotor that was tested with six stators, having throat areas from 20 to 144% of the design area. An incidence loss model is selected to obtain best agreement with experimental data. The stator vane end-clearance leakage model predicts increasing mass flow and decreasing efficiency as a result of end-clearances, with changes becoming significantly larger with decreasing stator area.

Meitner, P. L.↗

Radiation losses in resonant tubes

The role of radiation losses in a resonant tube - the transfer of sound energy from the test gas through the confines of the tube to the ambient atmosphere - is investigated both theoretically and experimentally. It is concluded that losses of this sort make no noticeable contribution to the background losses, even at high gas pressures. Nevertheless, if an axial resonant frequency of the test gas closely matches a longitudinal resonant frequency of the tube wall, the internal sound pressure can excite tube displacements of disproportionate magnitude and thus cause excessive losses, not due to radiation but rather to frictional dissipation related to the motion of the tube structure. This mechanism is effective when the mode numbers of the gas and tube have opposite parity, and makes sound absorption measurements at the fundamental gas frequency particularly problematical. An experimental investigation confirms the existence of such additional losses when the parity condition is fulfilled.

Zuckerwar, A. J.↗

Chromospheric structure in relation to radiation losses

It is assumed that cool star chromospheres are heated by mechanical energy dissipation that depends quasilinearly on density and cooled by radiation loss and it is shown that the basic properties of chromospheres are determined by the ionization of hydrogen. It is hydrogen ionization that provides the freedom for chromospheres to adjust their radiation losses to balance the prescribed heat input, resulting in an extended region of low temperature gradient. Chromospheric radiation losses in cool stars occur mainly in the strongest spectral lines at wavelengths greater than about 2000 A and the fraction of the chromosphere is effectively thin. The most important lines include Ca II H and K and the infrared triplet and Mg II h and k. The strong lines of other abundant species, are less important because their high excitation energies reduce the collisional excitation rates. Lyman alpha losses are important because of the overwhelming abundance of hydrogen. However, the inability of chromospheres to adjust their Lyman alpha losses limits the geometrical thickness of the effectively thin region in Lyman alpha and limits the total Lyman alpha flux.

Athay, R. G.↗

Chemical kinetic performance losses for a hydrogen laser thermal thruster

Projected requirements for efficient, economical, orbit-raising propulsion systems have generated investigations into several potentially high specific impulse, moderate thrust, advanced systems. One of these systems, laser thermal propulsion, utilizes a high temperature plasma as the enthalpy source. The plasma is sustained by a focused laser beam which maintains the plasma temperature at levels near 20,000 K. Since such temperature levels lead to total dissociation and high ionization, the plasma thruster system potentially has a high specific impulse decrement due to recombination losses. The nozzle flow is expected to be sufficiently nonequilibrium to warrant concern over the achievable specific impluse. This investigation was an attempt at evaluation of those losses. The One-Dimensional Kinetics (ODK) option of the Two-Dimensional Kinetics (TDK) Computer Program was used with a chemical kinetics rate set obtained from available literature to determine the chemical kinetic energy losses for typical plasma thruster conditions. The rates were varied about the nominal accepted values to band the possible losses. Kinetic losses were shown to be highly significant for a laser thermal thruster using hydrogen. A 30 percent reduction in specific impulse is possible simply due to the inability to completely extract the molecular recombination energy.

Mccay, T. D.↗

Ion loss processes in the stratosphere

Small ions consisting of aggregates of a few molecules determine th stratospheric electrical parameters such as conductivity, mobility, etc. The small ion density is controlled by the ionizing mechanisms for the production of ions and electrons and the loss processes for these charged particles. Ion production in stratosphere is chiefly due to galactic cosmic rays, and the loss processes due to recombination and attachment. Free electrons do not exist at stratospheric heights. The primary positive ion O2+ and the electrons are converted into complex clusters of positive and negative ions. The equilibrium ion density is governed by the equation of continuity for the production and loss of these ions. In the generalized equation of continuity, the gain or loss of ions due to transport is neglected. When aerosols or particulates are not present in the atmosphere, ions are loss due to ion-ion recombination. In the presence of aerosols, small ions can also be lost by attachment to the aerosols, and thus aerosols are likely to cause perturbations in the stratosphere electrification. A simplified model approach is adopted to study the effect of aerosols on the equilibrium ion density. The results of the analysis for the equatorial station Thumba (8.5 deg N) are presented.

Prasad, B. S. N.↗

Accuracy of telemetry signal power loss in a filter as an estimate for telemetry degradation

When telemetry data is transmitted through a communication link, some degradation in telemetry performance occurs as a result of the imperfect frequency response of the channel. The term telemetry degradation as used here is the increase in received signal power required to offset this filtering. The usual approach to assessing this degradation is to assume that it is equal to the signal power loss in the filtering, which is easily calculated. However, this approach neglects the effects of the nonlinear phase response of the filter, the effect of any reduction of the receiving system noise due to the filter, and intersymbol interference. Here, an exact calculation of the telemetry degradation, which includes all of the above effects, is compared with the signal power loss calculation for RF filtering of NRZ data on a carrier. The signal power loss calculation is found to be a reasonable approximation when the filter follows the point at which the receiving system noise is introduced, especially if the signal power loss is less than 0.5 dB. The signal power loss approximation is less valid when the receiving system noise is not filtered.

Koerner, M. A.↗

Nickel-hydrogen capacity loss on storage

A controlled experiment evaluating the capacity loss experienced by nickel electrodes stored under various conditions of temperature, hydrogen pressure, and electrolyte concentration was conducted using nickel electrodes from four different manufacturers. It was found that capacity loss varied with respect to hydrogen pressure, and storage temperature as well as with respect to electrode manufacturing processes. Impedance characteristics were monitored and found to be indicative of electrode manufacturing processes and capacity loss. Cell testing to evaluate state-of-charge effects on capacity loss were inconclusive as no loss was sustained by the cells tested in this experiment.

Manzo, Michelle A.↗

On the generation of mass loss in cool giant stars due to propagating shock waves

This paper investigates mass loss in late-type giant stars produced by propagating shock waves, assuming both monochromatic waves and acoustic frequency spectra. In monochromatic wave computations, the wave period is varied by a factor of 50. The wave models show that short-period waves produced in stellar convective zones do not play any direct role in generating the observed mass loss, except for episodic mass-loss events. However, these waves are important for heating stellar chromospheres. Continuous mass-loss solutions are obtained when the wavelengths are comparable to or larger than a stellar radius. In the case of Arcturus, a mass-loss rate between 10 to the -10th and 10 to the -11th solar mass/yr is found, and the final flow speed of the wind is larger than 40 km/s, which are close to the observed values.

Cuntz, Manfred↗

Nickel-hydrogen capacity loss on storage

A controlled experiment evaluating the capacity loss experienced by nickel electrodes stored under various conditions of temperature, hydrogen pressure, and electrolyte concentration was conducted using nickel electrodes from four different manufacturers. It was found that capacity loss varied with regard to hydrogen pressure and storage temperature, as well as with regard to electrode manufacturing processes. Impedance characteristics were monitored and found to be indicative of electrode manufacturing processes and capacity loss. Cell testing to evaluate state-of-charge effects on capacity loss were inconclusive as no loss was sustained by the cells tested in this experiment.

Manzo, Michelle A.↗

Stringent limits on the ionized mass loss from A and F dwarfs

Following the suggestion of Willson et al. (1987) that A- and F-type main-sequence stars might undergo significant mass loss due to pulsationally driven winds, upper limits to the ionized mass loss from A and F dwarfs have been obtained using VLA observations. These stringent upper limits show that the level of ionized mass loss would have at most only a small effect on stellar evolution. Radiative-equilibrium atmospheric and wind models for early A dwarfs indicate that it is highly likely that a wind flowing from such stars would be significantly ionized. In addition, late A and early F dwarfs exhibit chromospheric emission indicative of significant nonradiative heating. The present mass-loss limits are thus representative of the total mass-loss rates for these stars. It is concluded that A and F dwarfs are not losing sufficient mass to cause A dwarfs to evolve into G dwarfs.

Brown, Alexander↗

Performance of a high T(sub c) superconducting ultra-low loss microwave stripline filter

Discussed here is the successful fabrication of a five-pole interdigital stripline filter made of the 93-K superconductor (Y1Ba2Cu3O(y)) coated on a silver substrate, with center frequency of 8.5 GHz and an extremely high rejection ratio of 80 dB. The lowest insertion loss measured was 0.1 dB at 12 K, with a return loss of better than 16 dB, representing a significant improvement over a similar copper filter; it is comparable to low critical temperature filters. The insertion loss appears to be limited by extrinsic factors, such as tuning mismatch and joint losses, and not by the superconducting material losses.

Bautista, J. J.↗