Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “long pulse operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A rare gas optics-free absolute EUV photon spectrometer for solar system studies

We have developed a prototype spectrometer for space applications which require long term absolute EUV photon flux measurements. In this recently developed spectrometer, the energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer operating at a few eV, and followed by an electron multiplying detector, pulses due to individual electrons are counted. The overall efficiency of this process is essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided.

Daybell, M. D.↗

Hydrogen-oxygen auxiliary propulsion for the space shuttle. Volume 1: High pressure thrusters

Technology for long life, high performing, gaseous hydrogen-gaseous oxygen rocket engines suitable for auxiliary propulsion was provided by a combined analytical and experimental program. Propellant injectors, fast response valves, igniters, and regeneratively and film-cooled thrust chambers were tested over a wide range of operating conditions. Data generated include performance, combustion efficiency, thermal characteristics film cooling effectiveness, dynamic response in pulsing, and cycle life limitations.

Source record↗

Radar systems for a polar mission, volume 1

The application of synthetic aperture radar (SAR) in monitoring and managing earth resources is examined. Synthetic aperture radars form a class of side-looking airborne radar, often referred to as coherent SLAR, which permits fine-resolution radar imagery to be generated at long operating ranges by the use of signal processing techniques. By orienting the antenna beam orthogonal to the motion of the spacecraft carrying the radar, a one-dimensional imagery ray system is converted into a two-dimensional or terrain imaging system. The radar's ability to distinguish - or resolve - closely spaced transverse objects is determined by the length of the pulse. The transmitter components receivers, and the mixer are described in details.

Moore, R. K.↗

LED Intensity Decay Particle Tracking Velocimetry

A particle tracking velocimetry (PTV) system is demonstrated that eliminates the need for expensive lasers and cameras, and encodes the particle tracks with a known intensity variation which allows for high-resolution particle velocity and directionality determination. Using a light-emitting diode (LED) as the light source significantly reduces cost and allows for eye-safe operation, in comparison to traditional laser systems. The intensity variation control is passive, being dictated by the capacitance discharge rate in the LED pulsing circuit. The decay rate can be adjusted with the LED circuit capacitors/resistors, while the duration of the decay can be adjusted with the LED trigger pulse width. Because the intensity decay illumination is controlled by the LED, a single long exposure camera image is used to acquire images of the particle streaks, and there is no need for a more complicated and costly double-pulsing camera. With the intensity coding of the light, a single-camera/ single-LED system can identify particles entering of leaving the illumination plane, but cannot discern the direction toward or away from the camera. By using a two-color system, three-dimensionality of the particle tracks can be determined.

Joshua M Weisberger↗

Experimental Results of the Impact of an Ion Thruster Plasma on Microwave Propagation

Electric thrusters are being considered for a variety of space missions because of the significant propellant savings that result from the use of high performance, electric propulsion technologies, Propellant mass savings reduces spacecraft launch requirements and increases mission lifetime and payload. The impact of electric thruster plasma plumes on microwave signal propagation however is an important spacecraft integration concern. Arcjets were the first electric thrusters to be considered for operational missions. Ling, et al., studied the effect of arcjet plumes on propagation. Arcjets produce a lightly ionized plume and Ling's analysis predicted that the plume would have a negligible effect on communication. Plumes from the higher performance ion thrusters being developed exhibit higher ionization levels, plasma temperatures and particle velo@ities than arcjets. Therefore, there was a need to assess the impact due to these plumes. To address this need, the authors designed and performed a series of experiments to examine propagation effects of plumes. The challenge with these experiments was that they had to be performed in the operational environment of the thruster. Therefore, the experiments were conducted inside a metal chamber which could be depressurized to simulate a near vacuum condition of space. The metal chamber presents a potential large source of error to the propagation measurements due to the corruption of the desired data by multiple wall reflections within the chamber. This chamber effect was minimized by employing a pulsed-continuous wave transmitter and receiver system. This system, based on an HP8510 Network Analyzer, uses external hardware time gating to eliminate the clutter of the spurious reflections. Additionally, high gain antennas were used in the measurements to ensure that minimal amounts of energy ",ere transmitted/received in undesirable directions. The measurements took place in Vacuum Facility 5 of the Electric Propulsion Laboratory at the NASA Glenn Research Center. This facility utilizes a cylindrical, stainless steel, vacuum chamber, which is 18.3 m long and 4.6 m in diameter. For the tests being described here a 30 cm diameter, xenon ion thruster was used. The thruster provided between 500 W and 2.3 kW of operating power. The thruster was mounted on a stand along the axis of the chamber near one of its ends.

Zaman, Afroz J.↗

Experimental Results of the Impact of an Ion Thruster Plasma on Microwave Propagation

Electric thrusters are being considered for a variety of space missions because of the significant propellant savings that result from the use of high performance, electric propulsion technologies. Propellant mass savings reduces spacecraft launch requirements and increases mission lifetime and payload. The impact of electric thruster plasma plumes on microwave signal propagation however is an important spacecraft integration concern. Arcjets were the first electric thrusters to be considered for operational missions. Ling, et al. studied the effect of arcjet plumes on propagation. Arcjets produce a lightly ionized plume and Ling's analysis predicted that the plume would have a negligible effect on communication. Plumes from the higher performance ion thrusters being developed exhibit higher ionization levels, plasma temperatures and particle velocities than arcjets. Therefore, there was a need to assess the impact due to these plumes. To address this need, the authors designed and performed a series of experiments to examine propagation effects of plumes. The challenge with these experiments was that they had to be performed in the operational environment of the thruster. Therefore, the experiments were conducted inside a metal chamber which could be depressurized to simulate a near vacuum condition of space. The metal chamber presents a potential large source of error to the propagation measurements due to the corruption of the desired data by multiple wall reflections within the chamber. This chamber effect was minimized by employing a pulsed-continuous wave transmitter and receiver system. This system based on an HP8510 Network Analyzer, uses external hardware time gating to eliminate the clutter of the spurious reflections. Additionally, high gain antennas were used in the measurements to ensure that minimal amounts of energy were transmitted/received in undesirable directions. The measurements took place in Vacuum Facility 5 of the Electric Propulsion Laboratory at the NASA Glenn Research Center. This facility utilizes a cylindrical, stainless steel, vacuum chamber, which is 18.3 m long and 4.6 m in diameter. For the tests being described here a 30 cm diameter, xenon ion thruster was used. The thruster provided between 500 W and 2.3 kW of operating power. The thruster was mounted on a stand along the axis of the chamber near one of its ends and could be moved axially.

Zaman, Afroz J.↗

Space application of SEC vidicons - The OSO 7 coronagraph.

An externally occulted Lyot coronagraph employing a digitized SEC vidicon detection system is a prime experiment aboard the NASA Orbiting Solar Observatory 7 (OSO 7). Continuing daily operation since the 29 September 1971 launch has produced more than 2200 pictures of the solar white light corona covering the region between 3 R and 10 R. Important advantages of the SEC vidicon in this application are its ability to integrate an electron image and store it for long periods prior to readout. Special applications of digital techniques are employed in stepping and pulsing the readout electron beam, thereby realizing the detector's inherent qualities of high resolution and large dynamic range.

Brueckner, G.↗

Thrust Augmentation Measurements Using a Pulse Detonation Engine Ejector

The present NASA GRC-funded three-year research project is focused on studying PDE driven ejectors applicable to a hybrid Pulse Detonation/Turbofan Engine. The objective of the study is to characterize the PDE-ejector thrust augmentation. A PDE-ejector system has been designed to provide critical experimental data for assessing the performance enhancements possible with this technology. Completed tasks include demonstration of a thrust stand for measuring average thrust for detonation tube multi-cycle operation, and design of a 72-in.-long, 2.25-in.-diameter (ID) detonation tube and modular ejector assembly. This assembly will allow testing of both straight and contoured ejector geometries. Initial ejectors that have been fabricated are 72-in.-long-constant-diameter tubes (4-, 5-, and 6-in.-diameter) instrumented with high-frequency pressure transducers. The assembly has been designed such that the detonation tube exit can be positioned at various locations within the ejector tube. PDE-ejector system experiments with gaseous ethylene/ nitrogen/oxygen propellants will commence in the very near future. The program benefits from collaborations with Prof. Merkle of University of Tennessee whose PDE-ejector analysis helps guide the experiments. The present research effort will increase the TRL of PDE-ejectors from its current level of 2 to a level of 3.

Santoro, Robert J.↗

Design and Testing of Demonstration Unit for Maintaining Zero Cryogenic Propellant Boiloff

Launching of cryogenic propellants into earth orbit and beyond is very expensive. Each additional pound of payload delivered to low earth orbit requires approximately 35 pounds of additional weight at liftoff. There is therefore a critical need to minimize boiloff in spacecraft long term missions/systems. Various methods have been used to date, including superinsulation and thermodynamic vents to reduce boiloff. A system was designed and tested as described herein that will totally eliminate boiloff. This system is based on a closed-loop, two-stage pulse tube refrigerator with a net refrigeration of four watts at 15k for the recovery of hydrogen propellant. It is designed to operate at 30 Hz which is an order of magnitude higher than other typical pulse tube refrigerators. This high frequency allows the use of a much smaller, lighter weight compressor, This paper describes the system design, fabrication and test results.

Dean, W. G.↗

Aerosol Wind Profiler (AWP) Doppler Wind Lidar Airborne Observations During the NOAA Joint Venture 3-D Wind Measurement Demonstration and NASA Active-Passive Profiling Experiment (APEX)

The NASA Langley Research Center (LaRC) has recently completed development of the Aerosol Wind Profiler (AWP) airborne Doppler wind lidar (DWL) instrument. AWP was supported by the NASA Earth Science Technology Office and the Earth Science Division, a project that adapted the Wind-Space Pathfinder (Wind-SP) DWL transceiver onto a structure for flight aboard a variety of NASA research aircraft. AWP demonstrates many technologies required for a space DWL mission, including a coherent-detection, optical heterodyne laser transmitter with high pulse energy (up to ~55 mJ) and repetition rate (200 Hz), electronic control of the beam path allowing for multiple viewing angles (allowing vector wind measurements) with no moving parts, compact highly-stable and tunable reference lasers allowing for high-precision measurement of velocity at long ranges while mitigating the impact of satellite platform velocity, and many others. AWP represents NASA’s only currently operational airborne 3-D wind profiling sensor. NASA LaRC was selected by the NOAA Joint Venture (JV) program to conduct a suborbital 3-D Wind measurement campaign demonstrate how data from a coherent-detection DWL like AWP could serve NOAA’s weather analysis and forecasting needs. The NOAA JV program is designed to work with the private sector, academia and other federal agencies to explore the feasibility and capability of emerging technologies spacecraft and other mission-specific tools to meet NOAA’s mission requirements. AWP was initially demonstrated on the NASA DC-8 within this JV program in October 2023, piggybacking on the NASA EcoDemonstrator mission focused on in-situ sampling of jet aircraft emissions and contrail formation from Everett, Washington. The in-situ sampling resulted in very frequent and rapid aircraft attitude changes which unfortunately degraded AWP data quality. But, during times with level flight and AVAPS dropsonde operations, AWP demonstrated excellent precision (< 2 m/s RMS) with high vertical (< 100 meter) resolution and 2 km spacing between profiles. AWP will be flown again on the NASA LaRC Gulfstream-3 from mid-September to mid-October 2024 out of Hampton, VA to complete the NOAA JV 3-D wind demonstration. Additional AWP flights will occur in early November from southern California during the NASA Active-Passive Profiling Experiment (APEX), focused on underflights of the NASA ER-2 equipped with many atmospheric profiling sensors. This presentation will summarize AWP measurements collected during these two fall 2024 flight campaigns, and how the AWP data compares with AVAPS dropsonde, NOAA weather prediction model, and GOES atmospheric motion vector data.

Kristopher Bedka↗

Room-temperature operation of MOCVD-grown GaInAs/InP strained-layer multiquantum well lasers in 1.8 micron range

The first successful room-temperature pulsed operation is reported of InGaAs strained layer multiquantum well injection lasers grown by MOVPE on InP substrates in the 1.8 micron range. The threshold current density and the external differential quantum efficiency of the 10 micron wide ridge waveguide lasers were 2.5 kA/sq cm (cavity length = 1 mm) and 5 percent (cavity length = 400 microns), respectively. Broad-area lasers, 100 microns wide and 1 mm long, had a reverse leakage current of less than 10 microamps at -1 V indicating high quality of the epitaxial layers.

Forouhar, S.↗

Design and Performance Estimates of an Ablative Gallium Electromagnetic Thruster

The present study details the high-power condensable propellant research being conducted at NASA Glenn Research Center. The gallium electromagnetic thruster is an ablative coaxial accelerator designed to operate at arc discharge currents in the range of 10-25 kA. The thruster is driven by a four-parallel line pulse forming network capable of producing a 250 microsec pulse with a 60 kA amplitude. A torsional-type thrust stand is used to measure the impulse of a coaxial GEM thruster. Tests are conducted in a vacuum chamber 1.5 m in diameter and 4.5 m long with a background pressure of 2 microtorr. Electromagnetic scaling calculations predict a thruster efficiency of 50% at a specific impulse of 2800 seconds.

Thomas, Robert E.↗

Measuring Surface Bulk Elemental Composition on Venus

The extreme surface environment (462 C, 93 bars pressure) of Venus makes subsurface measurements of its bulk elemental composition extremely challenging. Instruments landed on the surface of Venus must be enclosed in a pressure vessel. The high surface temperatures also require a thermal control system to keep the instrumentation temperatures within their operational range for as long as possible. Since Venus surface probes can currently operate for only a few hours, it is crucial that the lander instrumentation be able to make statistically significant measurements in a short time. An instrument is described that can achieve such a measurement over a volume of thousands of cubic centimeters of material by using high energy penetrating neutron and gamma radiation. The instrument consists of a Pulsed Neutron Generator (PNG) and a Gamma-Ray Spectrometer (GRS). The PNG emits isotropic pulses of 14.1 MeV neutrons that penetrate the pressure vessel walls, the dense atmosphere and the surface rock. The neutrons induce nuclear reactions in the rock to produce gamma rays with energies specific to the element and nuclear process involved. Thus the energies of the detected gamma rays identify the elements present and their intensities provide the abundance of each element. The GRS spectra are analyzed to determine the Venus elemental composition from the spectral signature of individual major, minor, and trace radioactive elements. As a test of such an instrument, a Schlumberger Litho Scanner oil well logging tool was used in a series of experiments at NASA's Goddard Space Flight Center. The Litho Scanner tool was mounted above large (1.8 m x 1.8 m x.9 m) granite and basalt monuments and made a series of one-hour elemental composition measurements in a planar geometry more similar to a planetary lander measurement. Initial analysis of the results shows good agreement with target elemental assays

Venus↗

Ho:Tm:Er:LuAG and Two Wavelength Oscillation

Ho:Tm:Er:LuAG demonstrated simultaneous laser oscillation associated with two different transitions and different atoms. Two wavelength oscillation, or TWO, can be achieved in a single laser and single resonator. Moreover, the wavelength can be electronically controlled by varying the pump pulse length, Either the short wavelength, the Ho (5)1(sub 7) to (5)1(sub 8) transition at 2.1 microns, or the long wavelength, the Er (4)1(sub 11/2) to (4)1(sub 13/2) transition at 2.7 microns, or both wavelengths simultaneously can be produced without resorting to mechanical intervention. Consequently, a single laser system can easily switch between producing either of these useful wavelengths. Laser operation of both transitions has been characterized and is presented.

Barnes, Norman P.↗

Broadly tunable high-power operation of an all-solid-state titanium-doped sapphire laser system

Broadly tunable and high-power operation of a Ti-doped sapphire laser is obtained with a diode-laser-pumped frequency-doubled Nd:YAG laser as the pump source. A maximum broadband (FWHM = 25 nm) output pulse energy of 720 microJ at 795 nm in a TEM00 mode is obtained for 1850 microJ of energy of 532-nm pump light. A minimum pulse duration of 7 nsec is obtained from a 40-mm-long cavity. With the use of an intracavity prism, the Ti:sapphire laser is tunable continuously over the 696-1000-nm spectral range (with three different mirror sets).

Steele, T. R.↗

Validation of Lithium-ion cell technology for JPL's 2003 Mars Exploration Rover Mission

n early 2004 JPL successfully landed two Rovers, named Spirit and Opportunity, on the surface of Mars after traveling >300 million miles over a 6-7 month period. In order to operate for extended duration on the surface of Mars, both Rovers are equipped with rechargeable Lithium-ion batteries, which were designed to aid in the launch, correct anomalies during cruise, and support surface operations in conjunction with a triple-junction deployable solar arrays. The requirements of the Lithium-ion battery include the ability to provide power at least 90 sols on the surface of Mars, operate over a wide temperature range (-20 C to +40 C), withstanding long storage periods (e.g., cruise period), operate in an inverted position, and support high currents (e.g., firing pyro events). In order to determine the viability of Lithium-ion technology to meet these stringent requirements, a comprehensive test program was implemented aimed at demonstrating the performance capability of prototype cells fabricated by Lithion, Inc. (Yardney Technical Products, Inc.). The testing performed includes, determining the (a) room temperature cycle life, (b) pulse capability as a function of temperature, (e) self-discharge and storage characteristics mission profile capability, (f) cycle life under mission simulation conditions, (g) impedance characteristics, (h) impact of cell orientation, and (i) performance in 8-cell engineering batteries. As will be discussed, the Lithium-ion prototype cells and batteries were demonstrated to meet, as well as, exceed the requirements defined by the mission.

2003 Mars Exploration Rover (MER)↗

Gamma Ray Astronomy

The project has progressed successfully during this period of performance. The highlights of the Gamma Ray Astronomy teams efforts are: (1) Support daily BATSE data operations, including receipt, archival and dissemination of data, quick-look science analysis, rapid gamma-ray burst and transient monitoring and response efforts, instrument state-of-health monitoring, and instrument commanding and configuration; (2) On-going scientific analysis, including production and maintenance of gamma-ray burst, pulsed source and occultation source catalogs, gamma-ray burst spectroscopy, studies of the properties of pulsars and black holes, and long-term monitoring of hard x-ray sources; (3) Maintenance and continuous improvement of BATSE instrument response and calibration data bases; (4) Investigation of the use of solid state detectors for eventual application and instrument to perform all sky monitoring of X-Ray and Gamma sources with high sensitivity; and (5) Support of BATSE outreach activities, including seminars, colloquia and World Wide Web pages. The highlights of this efforts can be summarized in the publications and presentation list.

Wu, S. T.↗

Using GPS Receiver 1PPS Output to Verify Time Stamp Accuracy and Measure Propagation Delay

A simple pulse overlay circuit using a logic OR gate was developed to overlay a precise leading edge 1 pulse per second time reference marker from a global positioning system receiver onto a non-return -to- zero-level pulse code modulation telemetry data stream to validate time stamp accuracy and measure propagation delay in telemetry equipment. A pulse overlay (PO) circuit was designed to produce a time reference marker within a pulse code modulation (PCM) telemetry data stream that was recorded and analyzed to validate an IRIG Standard 106-17 Chapter 10 recorder’s time stamp accuracy [1]. A manufacturer of a newly purchased Chapter 10 recorder claimed the time stamp accuracy to be better than 10 microseconds (μs) with only IRIG-B120 (IRIG-B) input and better than 1 μs with IRIG-B and one pulse per second (1PPS) inputs. The PO circuit and a Chapter 10 recorder test setup were used to verify the vendor’s data-time synchronization claims and to justify infrastructure upgrade costs to connect additional cables to each purchased recorder. The circuit was also used to measure the propagation delay (PD) of a long distance Telemetry multiplexer/demultiplexer telecommunication system which the manufacturer did not provide a PD specification. Using the one pulse per second time reference marker of the global positioning system receiver and the pulse overlay circuit to overlay the one pulse per second variable pulse width signal into a pulse code modulation telemetry stream provided an excellent means to validate time stamp accuracy within a Chapter 10 recorder and to measure propagation delays within a normal telemetry operating environment. The positive results from the Chapter 10 recorder tests validated the vendor’s claims and justified the implementation to add the one pulse per second signal to the range Chapter 10 recorders. The pulse overlay circuit and test setups defined in this paper can easily be used to measure other telemetry equipment.

Knudtson, Kevin↗