Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Offshore Wind Project Study (Final Technical Report)

Within the Long Island electric service territory and throughout New York State there is increasing interest in and mandate for increasing clean energy technologies and renewable energy generation while reducing dependency on fossil fuels for electric production with goal of a carbon free system by 2040. This report discusses the implications of the reduction of forecasted load in the Long Island electric service territory and the impact of energy efficiency; increasing reliance of wind and other renewable resources on the transmission system; opportunities for interconnecting these resources; and reductions on the reliance of baseload fossil fueled power facilities over the coming years.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

GeoMelt{sup R} In-Container Vitrification (ICV){sup TM} for Fukushima Daiichi Water Treatment Secondary Wastes - 20212

The Japanese government is supporting development work implemented jointly by Veolia subsidiaries Kurion Japan, K.K., Veolia Nuclear Solutions (VNS), Inc., and Veolia Nuclear Solutions Federal Services, LLC for treating radioactive waste generated from Fukushima Daiichi Nuclear Power Station (NPS) water treatment using the GeoMelt{sup TM} In-Container Vitrification (ICV){sup TM} technology. The initial work consisted of glass formulation and engineering-scale testing which was completed in 2018, in the frame of an IRID (International Research Institute for Nuclear Decommissioning) program as part of a project subsidized by Japan's Ministry of Economy, Trade and Industry (METI). The Fukushima Daiichi NPS Mid- and Long-Term Road-map requires investigation of methods to stabilize solid wastes (and to immobilize radioisotopes in the wastes) generated as a result of emergency response and decommissioning activities. Cooling water treatment has resulted in a significant amount of solid and slurry secondary wastes (mostly adsorbents and ion-exchange materials) which will require processing at some point. GeoMelt{sup R} ICV{sup TM} is a joule-heated melter technology which uses a refractory-lined single-use container combining the melter and disposal container. There is no pouring required nor concerns with refractory corrosion which allows the process to accommodate a wide range of waste chemistries and high waste loadings. The testing described here consisted of three engineering-scale melts, each processing between 212 kg and 240 kg of waste simulants, glass formers, and non-radioactive cesium (Cs) and strontium (Sr) tracers. Continuous isokinetic stack sampling of off-gas emissions was performed for each test in order to calculate Cs and Sr retention in the glass wasteform. Single-pass retention of Cs in the final glass wasteform ranged from 91.46 to 99.30%, and single-pass retention of Sr ranged from 99.76 to 100%. Planned particulate recycle will increase these retention levels. Melt 1 processed a mixture of KUR-EH (a zeolite-based ion-exchange material), simulated Advanced Liquid Processing System (ALPS) Carbonate and Iron Slurries, and glass additives. Melt 2 processed a mixture of KUR-EH, KUR-TSG (a titanate-based adsorbent), and glass additives. Melt 3 processed a mixture of KUR-EH, simulated barium sulfate/iron ferrocyanide sludge (AREVA sludge), and glass additives. Waste loadings for these melts ranged from 70 weight percent (wt%) to 82 wt%. Vitrification produces a waste form much denser than the stored water treatment secondary waste wastes, resulting in significant volume reduction. Volume reductions for the three tests ranged from 74 to 79 vol%. Vitrification produces a chemically durable wasteform. Pacific Northwest National Laboratory (PNNL) tested three glass samples from each engineering-scale melt) by the Materials Characterization Center 1 (MCC-1) test, an international standard leach test of the chemical durability of nuclear waste glasses. PNNL also obtained one U.S. reference glass (EA Glass) and two Japan reference glasses P0798) and tested these under the same MCC-1 conditions (90 deg. C, 10 m-1, DIW, and 7, 14, 28-day) as the GeoMelt{sup R} ICV{sup TM} glasses. The GeoMelt{sup R} ICV{sup TM} glasses exhibited lower total normalized releases and 14- to 28-day normalized release rates than the three reference glasses. These results suggest that the GeoMelt{sup R} ICV{sup TM} glasses have durabilities on par with high-level waste glasses under standard test conditions. Post-melt process sampling and analysis indicated no Cs migration into the melter refractory materials and very little deposition of Cs or Sr onto the melter hood or off-gas piping internals. The results of the testing indicated good Cs retention in the glass, high volume reduction and waste loadings, and excellent chemical durability. These factors are important to minimize treatment costs and to protect workers and the environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Carbon nanodot precursors enable ultrahigh-loading copper single-atom catalysts for oxygen reduction reaction

Single-atom catalysts (SACs) have attracted significant attention in electrocatalysis due to their high metal utilization and tunable electronic structures; however, their practical implementation is often limited by poor atomic dispersion, low metal loadings (typically < 1 wt%), and insufficient anchoring of single metal atoms on catalyst supports. Herein, we report a simple and versatile strategy to synthesize copper single-atom catalysts (Cu-SACs) with ultrahigh metal loading using citric-acid-derived carbon nanodots as metal-capturing precursors. Through hydrothermal treatment followed by pyrolysis in the presence of urea, atomically dispersed copper atoms coordinated with nitrogen are incorporated into a carbon framework, achieving a Cu loading of up to 20 wt% while maintaining atomic dispersion. Notably, a significant fraction of the copper single atoms exists as Cu+–N2 coordination, which provides under-coordinated and catalytically active sites. The resulting Cu-SAC exhibits promising oxygen reduction reaction (ORR) activity in alkaline media, delivering a limiting current density comparable to that of commercial 20 wt% Pt/C with a predominant four-electron reduction pathway. Despite this high intrinsic activity, durability tests reveal gradual performance degradation under prolonged electrochemical operation, which is attributed to demetallation and aggregation of copper single atoms into metallic nanoparticles. These results demonstrate the potential of carbon nanodot-based platforms for synthesizing high-loading SACs, while underscoring the critical need to simultaneously control carbon porosity and metal–nitrogen coordination to enhance active-site accessibility and durability.

Sharma, Prakhar [University of Kentucky]↗

Charge Management for an Inductively Charged On-Demand Battery-Electric Shuttle Service with High Penetration of Renewable Energy

This paper presents a charge management control strategy for an on-demand battery-electric shuttle van operating at the National Renewable Energy Laboratory (NREL) campus and supported by day-time inductive charging at the vehicle's waiting spot. A new control algorithm has been proposed for reducing the demand charge costs incurred from wireless charging of the on-demand shuttle. A custom controller has been developed to monitor the shuttle, wireless charger, renewable energy generation, and various loads at NREL's campus, and regulate charging behavior for demand response. The intermittent renewable generation and sporadic operation of the on-demand shuttle service contribute to a high level of uncertainty in expected campus load profile, which must be carefully managed. The control algorithm predicts energy profile to estimate the mobility needs of the vehicle and maintain uninterrupted service during operation while still minimizing peak demand. The proposed controller has been designed and optimized using a Simulink model for the entire system. Next, it has been implemented and tested in real-time on the NREL campus. Two primary vehicle-use cases, charge sustaining and charge depletion operation, are tested under different load profiles and drive cycles to assess the controller's effectiveness at reducing peak demand and therefore demand charges. The proposed controller showed robust performance under different driving scenarios with high correlation between simulated and experimental data. The results showed that proper demand response can be achieved with an average of 94% reduction of charging loads during peak demand events.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗

Industrial battery operation and utilization in the presence of electrical load uncertainty using Bayesian decision theory

Behind the meter battery storage is becoming increasing popular in all sectors, though enthusiasm has recently lagged in the industrial sector. Even though there may be many factors contributing to this including lack of innovation, prohibitive costs, and undesirable rate structures, a difficulty arises in accounting for uncertainty of electrical load in industrial facilities while still attempting to utilize battery storage as much as possible all while trying to achieve fiscal profitability. Here this study utilizes Gaussian process regression and Bayesian decision theory to organize load data and quantify electrical load uncertainty to properly and effectively discharge industrial battery storage. The study employs a simulation model to set battery load setpoints for the span of the utility billing period according to the degree of risk aversion. This combination of economic analysis according to utility billing period and utilization of degree of risk aversion to make decisions on the uncertainty of the data has not before been applied to battery storage. The method resulted in an annual average reduction of peak demand by 3.8 % at the lowest amount of savings and lowest risk aversion. The highest risk aversion resulted in an annual average reduction of peak demand of 7.5 %. The maximum reduction of peak load in any month was 13.8 % in the month of December with a relatively high risk aversion. With a the highest amount risk aversion tested, the model reduced demand ten of the twelve months of the year.

25 ENERGY STORAGE↗

Broadly neutralizing humanized SARS-CoV-2 antibody binds to a conserved epitope on Spike and provides antiviral protection through inhalation-based delivery in non-human primates

The COVID-19 pandemic represents a global challenge that has impacted and is expected to continue to impact the lives and health of people across the world for the foreseeable future. The rollout of vaccines has provided highly anticipated relief, but effective therapeutics are required to further reduce the risk and severity of infections. Monoclonal antibodies have been shown to be effective as therapeutics for SARS-CoV-2, but as new variants of concern (VoC) continue to emerge, their utility and use have waned due to limited or no efficacy against these variants. Furthermore, cumbersome systemic administration limits easy and broad access to such drugs. As well, concentrations of systemically administered antibodies in the mucosal epithelium, a primary site of initial infection, are dependent on neonatal Fc receptor mediated transport and require high drug concentrations. To reduce the viral load more effectively in the lung, we developed an inhalable formulation of a SARS-CoV-2 neutralizing antibody binding to a conserved epitope on the Spike protein, ensuring pan-neutralizing properties. Administration of this antibody via a vibrating mesh nebulization device retained antibody integrity and resulted in effective distribution of the antibody in the upper and lower respiratory tract of non-human primates (NHP). In comparison with intravenous administration, significantly higher antibody concentrations can be obtained in the lung, resulting in highly effective reduction in viral load post SARS-CoV-2 challenge. This approach may reduce the barriers of access and uptake of antibody therapeutics in real-world clinical settings and provide a more effective blueprint for targeting existing and potentially emerging respiratory tract viruses.

60 APPLIED LIFE SCIENCES↗

Using a Multi‐Institutional Ensemble of Watershed Models to Assess Agricultural Conservation Effectiveness in a Future Climate

This study investigates the combined impacts of climate change and agricultural conservation on the magnitude and uncertainty of nutrient loadings in the Maumee River Watershed, the second-largest watershed of the Laurentian Great Lakes. Two scenarios — baseline agricultural management and increased agricultural conservation — were assessed using an ensemble of five Soil and Water Assessment Tools driven by six climate models. The increased conservation scenario included raising conservation adoption rates from a baseline of existing conservation practices to feasible rates in the near future based on farmer surveys. This increased adoption of winter cover crops on 6%–10% to 60% of cultivated cropland; subsurface placement of phosphorus fertilizers on 35%–60% to 68% of cultivated cropland; and buffer strips intercepting runoff from 29%–34% to 50% of cultivated cropland. Increased conservation resulted in statistically significant (p ≤ 0.05) reductions in annual loads of total phosphorus (41%), dissolved reactive phosphorus (18%), and total nitrogen (14%) under the highest emission climate scenario (RCP 8.5). While nutrient loads decreased with increased conservation relative to baseline management for all watershed models, different conclusions on the true effectiveness of conservation under climate change may be drawn if only one watershed model was used.

54 ENVIRONMENTAL SCIENCES↗

Proactive Operations and Investment Planning via Stochastic Optimization to Enhance Power Systems’ Extreme Weather Resilience

We present scalable stochastic optimization approaches for improving power systems’ resilience to extreme weather events. We consider both proactive redispatch and transmission line hardening as alternatives for mitigating expected load shed due to extreme weather, resulting in large-scale stochastic linear programs (LPs) and mixed-integer linear programs (MILPs). We solve these stochastic optimization problems with progressive hedging (PH), a parallel, scenario-based decomposition algorithm. Our computational experiments indicate that our proposed method for enhancing power system resilience can provide high-quality solutions efficiently. With up to 128 scenarios on a 2,000-bus network, the operations (redispatch) and investment (hardening) resilience problems can be solved in approximately 6 min and 2 h of wall-clock time, respectively. Additionally, we solve the investment problems with up to 512 scenarios, demonstrating that the approach scales very well with the number of scenarios. Moreover, the method produces high quality solutions that result in statistically significant reductions in expected load shed. Our proposed approach can be augmented to incorporate a variety of other operational and investment resilience strategies, or a combination of such strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Implementation of Smart Wireless Charging of On-Demand Shuttle Service for Demand Charge Mitigation

This paper presents a smart charge management strategy for an on-demand electric shuttle operating at the National Renewable Energy Laboratory (NREL) campus and supported by an inductive charger at the vehicle's waiting spot. A new control algorithm has been proposed for mitigating the demand charges incurred from the wireless charger. It monitors the shuttle, wireless charger, renewable energy generation, and other loads and regulates charging behavior for demand charge mitigation. Within the control algorithm, an energy prediction is made to estimate the mobility needs of the vehicle and maintain uninterrupted service during operation while still minimizing peak demand. The proposed controller is designed and optimized using a Simulink model for the entire system. It is then implemented and tested in real time at the NREL campus using online cloud services. Two vehicle-use cases' charge-sustaining and charge-depletion operation' are tested under different campus power profiles and drive cycles to assess the controller's performance. In this work, the proposed controller showed a robust performance under different driving scenarios, with high correlation between simulation and experimental data. The results show that proper demand response can be achieved, with an average of 94% reduction of charging loads during peak demand events.

33 ADVANCED PROPULSION SYSTEMS↗

Machine learning-enhanced MPC for demand flexibility in small commercial buildings: An experimental study

Small- and medium-sized commercial buildings (SMCBs) represent the majority of U.S. commercial building stock and a significant share of peak electricity demand, yet they often lack centralized building automation systems, representing a significant untapped resource for urban energy management. This infrastructure gap makes advanced control implementation challenging, limiting the potential for widespread demand flexibility. Model Predictive Control (MPC) has shown strong potential for load shifting, peak demand reduction, and cost savings, but its effectiveness is hindered by unmeasured disturbances such as internal heat gains. This paper presents a Hybrid MPC framework that integrates a physics-based gray-box building thermal model, identified using a lumped disturbance (LD) approach, with a machine learning (ML) model for forecasting unmeasured disturbances. The hybrid approach is designed for buildings with multiple individually controlled heat pump and thermostat pairs, common in SMCBs, and aims to optimize coordinated scheduling of multiple heat pumps under dynamic electricity pricing while respecting comfort constraints. The methodology is validated through both simulations of case study buildings and experimental studies at a highly-instrumented test facility. Simulation results show that the Hybrid MPC achieves substantial load shifting and peak demand reduction, approaching the performance of an ideal MPC with perfect disturbance knowledge, and outperforming a conventional MPC without disturbance forecasting. In experiments, the Hybrid MPC reduced daily HVAC energy costs by 8.7%, peak-price time load (load shifting) by 41.7%, and peak demand by 29.2% compared to baseline control, demonstrating comparable benefits to the 11.6% cost savings, 42.9% load shifting, and 23.2% peak reduction of the ideal MPC. These results demonstrate that the proposed hybrid modeling approach can significantly improve MPC performance in real-world SMCB applications without requiring additional disturbance measurements.

Demand Flexibility↗

Critical problems of energy frontier Muon Colliders: optics, magnets and radiation

This White Paper brings together our previous studies on a Muon Collider (MC) and presents a design concept of the 6 TeV MC optics, the superconducting (SC) magnets, and a preliminary analysis of the protection system to reduce magnet radiation loads as well as particle backgrounds in the detector. The SC magnets and detector protection considerations impose strict limitations on the lattice choice, hence the design of the collider optics, magnets and Machine Detector Interface (MDI) are closely intertwined. As a first approximation we use the Interaction Region (IR) design with beta-star=3 mm, whereas for the arcs we re-scale the arc cell design of the 3 TeV MC. Traditional cos-theta coil geometry and Nb3Sn superconductor were used to provide field maps for the analysis and optimization of the arc lattice and IR design, as well as for studies of beam dynamics and magnet protection against radiation. The stress management in the coil will be needed to avoid large degradation or even damage of the brittle SC coils. In the assumed IR designs, the dipoles close to the Interaction Point (IP) and tungsten masks in each IR (to protect magnets) help reducing background particle fluxes in the detector by a substantial factor. The tungsten nozzles in the 6 to 600 cm region from the IP, assisted by the detector solenoid field, trap most of the decay electrons created close to the IP as well as most of the incoherent electron-positron pairs generated in the IP. With sophisticated tungsten, iron, concrete and borated polyethylene shielding in the MDI region, the total reduction of background loads by more than three orders of magnitude can be achieved.

43 PARTICLE ACCELERATORS↗

Load-Shifting Strategies for Cost-Effective Emission Reductions at Wastewater Facilities

Significant hourly variation in the carbon intensity of electricity supplied to wastewater facilities introduces an opportunity to lower emissions by shifting the timing of their energy demand. This shift could be accomplished by storing wastewater, biogas from sludge digestion, or electricity from on-site biogas generation. However, the life cycle emissions and cost implications of these options are not clear. Here, we present a multiobjective optimization framework for comparing cost- and emission-minimizing load-shifting strategies at a California case study facility with a relatively low carbon intensity grid and high spread in peak and off-peak electricity prices. We evaluate cost and emission trade-offs from the optimal flexible operation of both existing infrastructure and optimally sized energy flexibility upgrades. We estimate energy-related emission reductions of up to 9.0% with flexible operation of existing infrastructure and up to 16.8% with optimally sized storage upgrades. Only a fraction of these potential savings are realized under actual industrial energy tariffs and the EPA’s recommended social cost of carbon. Energy flexibility may hold promise as a short-term emission-saving solution for the wastewater sector, but the extent of savings is heavily dependent on the cost of carbon, electricity tariffs, and emission intensity of the regional electricity grid.

climate↗

Integration of a grey-box refrigerated case model in EnergyPlus via Python plugin

Commercial buildings, in particular grocery stores (due mainly to their large refrigeration load), provide opportunities for energy cost reductions. Grocery stores could offer substantial load flexibility to the power grid through participation in demand response programs because of their usage patterns and relatively high energy intensity. This load flexibility could come from modifying the control of heating, ventilation, and air conditioning (HVAC) systems, refrigeration systems, or both. Although estimation of the HVAC system’s load flexibility potential is relatively targeted in the literature, estimating load flexibility of refrigeration systems is nascent and has been a challenge, in part because of the lack of proper simulation tools that capture the dynamics in the refrigeration cases. The existing refrigerated case model within EnergyPlus, a whole building energy simulation program, assumes a constant case temperature throughout the simulation period and does not explicitly model the cycling of the compressor serving the refrigerated case. In addition, it does not encompass modeling of temperatures of the product inside the refrigerated case. This difference between modeled and actual operation can be a barrier to the development of demand control algorithm and accurate analysis of load flexibility potential. In this paper, we present a grey-box model for modeling refrigerated cases in grocery stores, which include medium temperature and low temperature. Four cases are modeled; two are low-temperature closed cases and two are medium-temperature cases with one closed and one open. Data from an experimental facility are used to train and test the models. Results demonstrate the efficacy of the grey-box models in predicting the temperatures. This model is integrated into EnergyPlus to capture the dynamic effects of case temperature on the environment and enhance the calculation of sensible and latent heat exchange with the environment (case credits). These enhancements can be leveraged more broadly to model advanced refrigeration controls such as defrost, develop and test unique algorithms that could affect refrigeration interactions with HVAC, and refine store design for any commercial building with refrigeration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Better management practices for environmentally sustainable production of microalgae and algal biofuels

The commercialization of biofuels produced from microalgae is in its infancy; therefore, many resource-management practices and production processes are still flexible. The purpose of this paper is to guide development of supply chains toward more environmentally sustainable practices. Furthermore, in this work, we review current and projected technologies and practices for autotrophic microalgae cultivation that promote environmental sustainability. We develop a framework that leverages these studies to propose better management practices (BMPs) for water quality and quantity, biodiversity, or greenhouse gas emissions in concert with productivity and profitability considerations. Some proposed BMPs are linked to numerical environmental targets, such as percent reductions in nutrient loadings to streams, whereas others seek to avoid thresholds leading to adverse health or ecological effects. Still others involve using the best available technologies, developed iteratively through life-cycle and techno-economic analyses. Proposed BMPs for microalgae cultivation focus on water quality and quantity, as well as improving greenhouse gas (GHG) emissions to obtain advanced biofuel designation. BMPs must allow producers to meet productivity and profitability targets, as well as environmental targets. These example BMPs characterize the state of science and engineering; thus, they will change over time.

09 BIOMASS FUELS↗

In-situ and in-operando analysis of voltage losses using sense wires for proton exchange membrane water electrolyzers

Proton exchange membrane water electrolyzer development requires understanding processes at the materials and interface levels to reach the required performance and lifetime targets for increasing market penetration. To achieve the required progress, it is critical to develop advanced in-situ diagnostics that allow observation of the changes that come with the reduction of catalyst loading combined with long-term intermittent operation. This work presents an internal voltage sensing method that enables observing internal voltage drops in an operating electrolyzer cell. It allows the total cell resistance to be separated into anode, CCM, and cathode resistance. The method is demonstrated by operating cells with different anode porous transport layers (PTLs). The changing properties of the PTLs result in significant variations of the resistances. Enhancing the PTL properties with a protective coating reduces the anode resistance significantly. In addition to these observations, the method enables a real-time monitoring of resistance related values that impact performance in water electrolyzers. Long-term experiments with the method allow us to gain insights into processes that occur during operation such as conditioning or degradation. The internal voltage sensing method presented in this study is a novel technique for diagnosing, analyzing, and optimizing water electrolyzers and other energy conversion devices.

42 ENGINEERING↗

Pseudo-viscous modeling of transport in dense granular flows for thermal energy storage applications

Dense, granular flows were examined to effectively capture and model bulk viscous properties in thin packed beds. A modified Couette cell with particle image velocimetry was used to experimentally determine pseudo-viscosity properties of four particulate media with varying morphologies: (1) iron oxide-coated SiO 2 particles, (2) CARBOBEAD CP30-60 particles, (3) CARBOBEAD CP40-100 particles, and (4) Al 2 O 3 beads. The pseudo-viscosity functions were fitted using a power law to correlate the measured shear stress as a function of measured shear rate. The pseudo-viscous functions were used as inputs to computation fluid dynamics models for a single-phase viscous fluid to predict granular flow profiles. Steady-state free surface velocity profiles at angular velocities <7 rad/s predicted by the model were in good agreement with the experimental particle image velocimetry measurements, resulting in Pearson correlation coefficients of 0.97 for iron-oxide coated SiO 2 particles and 0.95 for CP30-60 particles. As a result, this alternative approach to measuring pseudo-viscous properties under shearing and modeling bulk transport behavior of granular flow using computation fluid dynamics model offered significant reduction in computational load compared to discrete element methods.

14 SOLAR ENERGY↗

Electrochemical leaching of spent LIBs: Kinetics, novel reactor, and modeling

The use of electrons as main reagent for the recovery and recycling of critical metals from spent lithium-ion batteries (LIBs) is a process electrification strategy that can be used to close the life-cycle loop of LIBs through more sustainable methods. Electrochemical leaching, a process that uses a reductant that is constantly regenerated electrochemically for the leaching of lithium-ion battery black mass (LIBBM), has shown high extraction efficiencies and sustainable scores. However, slow kinetics, reactor design challenges and lack of deeper understanding of the underlying processes are barriers to the optimization, scale-up, and market adoption of this technology. In this paper, a kinetic study and mathematical model for dissolving LIBBM is presented to better understand the underlying mechanisms aiming to reduce the processing time and make predictions for future design and scale-up. The effect of acid and electrochemically mediated reductant concentrations, LIBBM loading, and cathode/reactor designs were explored. As a result, the leaching time was reduced from 7h to under 1h at a pulp density of 73 g/L, without external heating. A novel reactor with parallel baffle electrodes (PBE) was developed, which significantly reduced the leaching time by improving convection in a stirred slurry electrochemical reactor. Dimensionless numbers were deduced from an unsteady state model, which can be used in dimensional analysis for future process design and scale-up.

25 ENERGY STORAGE↗