Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Toward high solids loading process for lignocellulosic biofuel production at a low cost: Biofuel Production at High Solids Loading

High solids loadings (>18 wt%) in enzymatic hydrolysis and fermentation are desired for lignocellulosic biofuel production at a high titer and low cost. However, sugar conversion and ethanol yield decrease with increasing solids loading. The factor(s) limiting sugar conversion at high solids loading is not clearly understood. In the present study, we investigated the effect of solids loading on simultaneous saccharification and co-fermentation (SSCF) of AFEX™ (ammonia fiber expansion) pretreated corn stover for ethanol production using a xylose fermenting strain Saccharomyces cerevisiae 424A(LNH-ST). Decreased sugar conversion and ethanol yield with increasing solids loading were also observed. End-product (ethanol) was proven to be the major cause of this issue and increased degradation products with increasing solids loading was also a cause. For the first time, we show that with in situ removal of end-product by performing SSCF aerobically, sugar conversion stopped decreasing with increasing solids loading and monomeric sugar conversion reached as high as 93% at a high solids loading of 24.9 wt%. In this work, techno-economic analysis was employed to explore the economic possibilities of cellulosic ethanol production at high solids loadings. The results suggest that low-cost in situ removal of ethanol during SSCF would significantly improve the economics of high solids loading processes.

09 BIOMASS FUELS↗

Dependence of twinned volume fraction on loading mode and Schmid factor in randomly textured magnesium

Here, the twinning activity in random textured cast magnesium during room temperature tension and compression tests was monitored by neutron diffraction (ND). Variation of integrated intensities of selected diffraction peaks, characterizing the twinned volume in particularly oriented grains was compared with calculated Schmid factors for extension twinning of these grains. It is shown that in tension there is a direct proportion between the twinned volume and the maximum value of the Schmid factor for a given grain orientation. In contrast, in compression this relation is not valid. The twinned volume in this case is influenced by both deviation of the grain from the ideal orientation and its rotation around the c-axis. The experimental results are in good agreement with those obtained from elasto-plastic self-consistent (EPSC) modeling.

36 MATERIALS SCIENCE↗

An Exploratory Risk Perception Study of Attitudes Toward Homeland Security Systems

Understanding the issues surrounding public acceptance of homeland security systems is important for balancing security needs and potential civil liberties infringements. A psychometric survey was used to measure attitudes regarding homeland security systems. Psychometric rating data were obtained from 182 respondents on psychological attributes associated with 12 distinct types of homeland security systems. An inverse relationship was observed for the overall rating attributes of acceptability and risk of civil liberties infringement. Principal components analysis yielded a two factor solution, with the rating scale loading pattern suggesting factors of Perceived Effectiveness and Perceived Intrusiveness. These factors also showed an inverse relationship. The 12 different homeland security systems showed significantly different scores on the rating scales and PCA factors, which were used to rank the systems in terms of overall acceptability. Difference scores for the rating scales and PCA factors were used to compute a single acceptability value reflecting the relative weight of risks and benefits. Of the 12 systems studied, airport screening, canine detectors and radiation monitoring at borders were found to be relatively acceptable, i.e., the perceived benefits for homeland security outweighed the perceived risks to civil liberties. Students rated several systems as more effective than professionals, but the overall pattern of results for both types of subjects was similar. The data suggest that risk perception research and the psychometric paradigm are useful approaches for quantifying attitudes regarding homeland security systems and policies, and can be used to anticipate potentially significant public acceptance issues.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Perturbation theory to model shielding effectiveness of cavities loaded with electromagnetic dampeners

It is notable that a slotted resonant cavity with high-quality factor exhibits interior electromagnetic (EM) fields that may be even larger than the external field. The authors aspire to reduce the cavity's EM fields and quality factor over a frequency band analytically, numerically, and experimentally by introducing microwave absorbing materials in the cavity. A perturbation model approach was developed to estimate the quality factor of loaded cavities, which is validated against full-wave simulations and experiments. Conclusions with 78.7 mils (2 mm) thick ECCOSORB-MCS absorber placed on the inside cavity wall above and below the aperture slot (with only 0.026% cavity volume) result in a reduction of shielding effectiveness >19 dB and reductions in quality factor >91%, providing confirmation of the efficacy of this approach.

42 ENGINEERING↗

Analysis of Reactive Power Load Modeling Techniques for PV Impact Studies [Slides]

The increasing availability of advanced metering infrastructure (AMI) data has led to significant improvements in load modeling accuracy. However, since many AMI devices were installed to facilitate billing practices, few utilities record or store reactive power demand measurements from their AMI. When reactive power measurements are unavailable, simplifying assumptions are often applied for load modeling purposes, such as applying constant power factors to the loads. The objective of this work is to quantify the impact that reactive power load modeling practices can have on distribution system analysis, with a particular focus on evaluating the behaviors of distributed photovoltaic (PV) systems with advanced inverter capabilities. Quasi-static time-series simulations were conducted after applying a variety of reactive power load modeling approaches, and the results were compared to a baseline scenario in which real and reactive power measurements were available at all customer locations on the circuit. Overall, it was observed that applying constant power factors to loads can lead to significant errors when evaluating customer voltage profiles, but that performing per-phase time-series reactive power allocation can be utilized to reduce these errors by about 6x, on average, resulting in more accurate evaluations of advanced inverter functions.

14 SOLAR ENERGY↗

An islanding detection methodology combining decision trees and Sandia frequency shift for inverter-based distributed generations

Distributed generations (DGs) for grid-connected applications require an accurate and reliable islanding detection methodology (IDM) for secure system operation. This paper presents an IDM for grid-connected inverter-based DGs. The proposed method is a combination of passive and active islanding detection techniques for aggregation of their advantages and elimination/minimisation of the drawbacks. In the proposed IDM, the passive method utilises critical system attributes extracted from local voltage measurements at target DG locations as well as employs decision tree-based classifiers for characterisation and detection of islanding events. The active method is based on Sandia frequency shift technique and is initiated only when the passive method is unable to differentiate islanding events from other system events. Thus, the power quality degradation introduced into the system by active islanding detection techniques can be minimised. Furthermore, a combination of active and passive techniques allows detection of islanding events under low power mismatch scenarios eliminating the disadvantage associated with the use of passive techniques alone. Finally, detailed case study results demonstrate the effectiveness of the proposed method in detection of islanding events under various power mismatch scenarios, load quality factors and in the presence of single or multiple grid-connected inverter-based DG units.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Residual Stress and Opening-Mode Fracture Analysis of Multilayered Structures Subjected to Thermal Loading

Temperature change after formation commonly results in thermal residual stress in multilayered structures due to the different thermal and mechanical properties of each layer. In this paper, a three-dimensional (3D) elastic model is developed to study the residual stress and opening-mode fractures (OMFs) in a multilayered structure consisting of arbitrary number of layers under temperature change. The general solution of displacement field in the multilayered structure is derived by solving the elastic boundary value problem. In order to verify the proposed model, the elastic field in the advanced polymeric solar reflectors that consist of four layers is solved by applying the present model and compared with the finite-element (FE) simulation. In addition, parametric studies are conducted to investigate the effect of the thickness ratio between each layer on the accuracy of the developed model. As a result, based on the obtained elastic field, the fracture energy release rate (ERR) in the surface layer of the advanced polymeric reflector is obtained and used to study the fracture initiation, infilling, and saturation successfully.

36 MATERIALS SCIENCE↗

Modeling of Inductive Constant Power Load for Electromagnetic-Transient Simulations-Part II

This paper improves the dynamic constant power (CP) load model that was published in Part I, which is appropriate for electromagnetic-transient (EMT). The improved model conserves all features of its predecessor. For instance, it maintains a fixed power consumption (both active and reactive parts) and a fixed power factor for loads that are predominantly inductive. Furthermore, as the proposed model is a time-dependent system, it is applicable to both sinusoidal and non-sinusoidal case studies. However, the previous model cannot be easily integrated with numeric solvers because it simulated load data over one cycle all together, not sequentially in a time-step manner, due to the limitation involved with the power factor. The improved version, on the contrary, allows the load to be simulated at every time step, which would facilitate its integration with numeric solvers. The model's validity is confirmed by comparing its response with data that is synthesized from constant impedance load, and the result is satisfactory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A bound on electromagnetic penetration through a slot aperture with backing cavity

This report examines bounds on the penetrant power through ports of entry into a conductive cavity. We first replace the cavity by a load and consider the maximum power transfer properties of an antenna or an aperture. We consider how limitations on the load quality factor place limits on received power. For general frequency ranges we model the backing region by means of a uniformly distributed matched load along a slot aperture and adjust its value for maximum power transfer. This result is derived in closed form using a transmission line model for the aperture. This result illustrates the reduction in received power for low frequencies with finitely conducting wall materials. At high frequencies it approaches the receiving cross section of a linear array having the slot length dimension. Next we examine a slot aperture in a conducting rectangular enclosure and determine how the cavity wall losses and resulting quality factor limit the penetrant power. Detailed simulations and experimental measurements are compared with each other and with the bounding results to assess the accuracy of the bounds. These comparisons also indicate limitations on the accuracy of the models due to perturbing influences in construction, such as bolted joints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model-centric distribution automation: Capacity, reliability, and efficiency

A series of analyses along with field validations that evaluate efficiency, reliability, and capacity improvements of model-centric distribution automation are presented. With model-centric distribution automation, the same model is used from design to real-time control calculations. A 14-feeder system with 7 substations is considered. The analyses involve hourly time-varying loads and annual load growth factors. Phase balancing and capacitor redesign modifications are used to better prepare the system for distribution automation, where the designs are performed considering time-varying loads. Coordinated control of load tap changing transformers, line regulators, and switched capacitor banks is considered. In evaluating distribution automation versus traditional system design and operation, quasi-steady-state power flow analysis is used. In evaluating distribution automation performance for substation transformer failures, reconfiguration for restoration analysis is performed. In evaluating distribution automation for storm conditions, Monte Carlo simulations coupled with reconfiguration for restoration calculations are used. As a result, the evaluations demonstrate that model-centric distribution automation has positive effects on system efficiency, capacity, and reliability.

25 ENERGY STORAGE↗

AMICE2 measurements of lab-generated and ambient aerosols at BNL from 2025-07-21 to 2025-08-22

From July 21 through August 22, 2025 the Absorption Measurement Inter-Comparison Experiment phase 2 (AMICE2) was conducted at Brookhaven National Laboratory. The experiment included concurrent operation of several filter-based instruments and in situ instruments sampling from a common sample line. The common sample line provided all instruments with either lab-generated aerosols composed of external mixtures of nigrosin, cabojet, and ammonium sulfate, or with ambient aerosol drawn through an external stack. This data set contains measurements from the CAPS PMssa instrument taken as a reference instrument at 532 nm and against which the effectiveness of the filter corrections may be assessed. It also contains attenuation coefficients from all filter-based instruments and filter transmittances in order to permit correction for filter loading, and the SSA and COA to permit corrections for aerosol darkness. Finally, two sets of multiplicative corrections are provided for the AE-33, TAP, and MA-350 instruments: the first one, Corr1, corrects for filter amplification factor and loading, the second one, Corr2, corrects for the aerosol darkness in terms of the natural log of COA.

Aerosol Extinction↗

Deepest sensitivity to wavelike dark photon dark matter with superconducting radio frequency cavities

Wavelike, bosonic dark matter candidates like axions and dark photons can be detected using microwave cavities known as haloscopes. Traditionally, haloscopes consist of tunable copper cavities operating in the TM 010 mode, but ohmic losses have limited their performance. In contrast, superconducting radio frequency (SRF) cavities can achieve quality factors of ∼ 10 10 , perhaps 5 orders of magnitude better than copper cavities, leading to more sensitive dark matter detectors. In this paper, we first derive that the scan rate of a haloscope experiment is proportional to the loaded quality factor Q L , even if the cavity bandwidth is much narrower than the dark matter halo line shape. We then present a proof-of-concept search for dark photon dark matter using a nontunable ultrahigh-quality SRF cavity. We exclude dark photon dark matter with kinetic mixing strengths of χ > 1.5 × 10 − 16 for a dark photon mass of m A ′ = 5.35 μ eV , achieving the deepest exclusion to wavelike dark photons by almost an order of magnitude. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Active Modulation Scheme to Boost Voltage Utilisation of the Dual Converter with a Floating Bridge

This paper proposes a capacitor voltage regulation method for the dual converter with a floating bridge for aerospace applications. This topology has previously been reported, but with a constrained voltage utilisation factor due to the need for capacitor voltage regulations. The effect of switching states on the voltage variation of capacitor is quantitatively modelled and an enhanced space vector modulation scheme with current feedback is proposed to achieve an active control of the floating capacitor voltages. This proposed method also allows further exploitation and utilisation of converter voltage. The relationship between the allowed modulation index of dual converter and load power factor is obtained and expressed using a fitted polynomial equation. The advantages of the proposed method include boosted voltage utilisation and superior performance in term of capacitor voltage balance. These advantages have been proven through simulation and experimental results on RL loads as well as with an open-end winding induction motor. The proposed modulation scheme can boost the converter voltage utilisation by at least 10% while achieving full four-level operation. More importantly, the higher available voltage allows extending the constant torque region of the motor, the further beginning of field weakening operation could be postponed.

42 ENGINEERING↗

Response relationship between loading condition and corrosion fatigue behavior of nickel-aluminum bronze alloy and its crack tip damage mechanism

Highlights: • The differences of corrosion fatigue behavior of NAB alloy in air and in 3.5% NaCl solution are carefully compared. • The corrosion environment significantly accelerates the crack growth of NAB alloy and decreases the fatigue threshold. • The corrosion fatigue crack growth rate increases with the decrease of loading frequency. • The acidification and the dealumination occur in process of corrosion fatigue, resulting in the deterioration of crack tip. - Abstract: Corrosion fatigue is one of the major forms for nickel‑aluminum bronze alloy used in marine propeller. It is greatly important to understand the corrosion fatigue behavior of nickel‑aluminum bronze alloy in seawater for the purpose of improving the service life of marine equipment. In this study, corrosion fatigue crack growth rate of nickel‑aluminum bronze alloy in 3.5% NaCl solution was tested under various stress intensity factors, stress ratios and loading frequencies to reveal its corrosion fatigue mechanism. The results show that corrosion environment significantly accelerates the crack growth and decreases the corrosion fatigue threshold, which is attributed to the corrosion reactions between the metals of crack tip and corrosive medium. Among the various factors, loading frequency has more predominant influence on the corrosion fatigue crack growth rate of nickel‑aluminum bronze alloy, which can be rationally explained by the hydrogen embrittlement mechanism. Additionally, in the process of corrosion fatigue crack growth, the acidification and the dealumination would occur at the crack tip, resulting in the corrosion dissolution of κ phases and the deterioration in mechanical properties of crack tip.

36 MATERIALS SCIENCE↗

Measurements of near-ultimate strength for multiwalled carbon nanotubes and irradiation-induced crosslinking improvements.

The excellent mechanical properties of carbon nanotubes are being exploited in a growing number of applications from ballistic armour to nanoelectronics. However, measurements of these properties have not achieved the values predicted by theory due to a combination of artifacts introduced during sample preparation and inadequate measurements. Here we report multiwalled carbon nanotubes with a mean fracture strength >100 GPa, which exceeds earlier observations by a factor of approximately three. These results are in excellent agreement with quantum-mechanical estimates for nanotubes containing only an occasional vacancy defect, and are {approx}80% of the values expected for defect-free tubes. This performance is made possible by omitting chemical treatments from the sample preparation process, thus avoiding the formation of defects. High-resolution imaging was used to directly determine the number of fractured shells and the chirality of the outer shell. Electron irradiation at 200 keV for 10, 100 and 1,800 s led to improvements in the maximum sustainable loads by factors of 2.4, 7.9 and 11.6 compared with non-irradiated samples of similar diameter. This effect is attributed to crosslinking between the shells. Computer simulations also illustrate the effects of various irradiation-induced crosslinking defects on load sharing between the shells.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Connecting Risk and Resilience for a Power System Using the Portland Hills Fault Case Study

Active seismic faults in the Pacific Northwest area have encouraged electric utilities in the region to deeply contemplate and proactively intervene to support grid resilience. To further this effort this research introduces Monte Carlo (MC)-based power system modeling as a means to inform the Performance Based Earthquake Engineering method and simulates 100,000 sample earthquakes of a 6.8 magnitude (M6.8) Portland Hills Fault (PHF) scenario in the Portland General Electric (PGE) service territory as a proof of concept. This paper also proposes the resilience metric Seismic Load Recovery Factor (SLRF) to quantify the recovery of a downed power system and thus can be used to quantify earthquake economic risk. Using MC results, the SLRF was evaluated to be 19.7 h and the expected economic consequence cost of a M6.8 PHF event was found to be $\$180$ million with an annualized risk of $\$90,000$ given the event’s 1 in 2000 year probability of occurrence. The MC results also identified the eight most consequential substations in the PGE system—i.e., those that contributed to maximum load loss. This paper concludes that retrofitting these substations reduced the expected consequence cost of a M6.8 PHF event to $117 million.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model Development for the ACME Lab Modular Wall and A-Frame Assemblies

The structural frame used for conducting large structural tests was replaced by the ACME (Applied Combined Mechanical Environments) Lab in Building 860 of Sandia National Laboratories in Albuquerque, NM. This new design required simulation and analysis to verify maximum loads and corresponding factors of safety. Two major assemblies which are part of the ACME Lab, the Modular Wall and A-Frame, were designed to operate with a multitude of components in various configurations and with varying loads. Simulations of the Modular Wall and A-Frame structures were performed through explicit analysis to determine safety factors for numerous loading scenarios. The Modular Wall had safety factors of 1.1 for the lateral, diagonal, and gusset loading conditions. The A-Frame had safety factors of 2 for all loading conditions simulated.

42 ENGINEERING↗