Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lithium detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Development of a thermal neutron detector based on scintillating fibers and silicon photomultipliers

We propose a technique for thermal neutron detection, based on a {sup 6}Li converter placed in front of scintillating fibers readout by means of silicon photomultipliers. Such a technique allows building cheap and compact detectors and dosimeters, thus possibly opening new perspectives in terms of granular monitoring of neutron fluxes as well as space-resolved neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High efficiency method of fast neutron detection by oxide scintillators for detection systems of fissionable radioactive substances

Comparative measurements and analysis of detection efficiency (DE) of fast neutrons from {sup 239}Pu-Be source have been carried out in a broad energy range En {approx} 0.1 ./. 10 MeV using oxide scintillators BGO, GSO, CWO, ZnWO, ZnSe(Te, O), as well as LiI(Eu). DE of fast neutrons by heavy oxide scintillators was found to be very high ({approx} 40-50 %). The neutron inelastic scattering reaction (n, n'y) is considered as the most probable interaction mechanism of neutrons with nuclei of heavy oxide scintillators. It is concluded that heavy oxide scintillators, which are at the same time efficient gamma-detectors, allow creation of a highly efficient gamma-neutron detector ensuring high detection efficiency of fissionable radioactive substances. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing extreme fast charge battery protocols – A review spanning materials to systems

Extreme fast charging (XFC) has become a focal research point in the lithium-battery community over the last several years. As adoption of electric vehicles increases, fast charging has become a key driver in enhancing consumer recharge experience. Recently, the research community has made significant improvements in developing charge protocols to support XFC. New charge protocol designs derived using a combination of advanced, physically derived models, and electrochemical and secondary characterization methods, increase charge acceptance and decrease aging. By coordinating these methods and modifying protocols to account for different material constraints, including lithium plating and cathode particle degradation, novel charge protocols have increased the energy accepted during charging by over 25% in 10 min and increased the charge acceptance prior to a constant-voltage step by approximately 3x. Here, we review several charge-protocol advances, aging factors which are enhanced by XFC and advances which will enable adoption of XFC capable vehicles. These advances include implementing machine learning and other detection algorithms to reduce and classify lithium plating, which is known to significantly degrade cell performance and reduce cell life. The review concludes by discussing full-system fast charge requirements, including electric vehicle service equipment needs for implementing XFC protocols.

25 ENERGY STORAGE↗

The nonexistence of a paddlewheel effect in superionic conductors

Since the 1980s, the paddlewheel effect has been suggested as a mechanism to boost lithium-ion diffusion in inorganic materials via the rotation of rotor-like anion groups. However, it remains unclear whether the paddlewheel effect, defined as large-angle anion group rotations assisting Li hopping, indeed exists; furthermore, the physical mechanism by which the anion-group dynamics affect lithium-ion diffusion has not yet been established. In this work, we differentiate various types of rotational motions of anion groups and develop quaternion-based algorithms to detect, quantify, and relate them to lithium-ion motion in ab initio molecular dynamics simulations. Our analysis demonstrates that, in fact, the paddlewheel effect, where an anion group makes a large angle rotation to assist a lithium-ion hop, does not exist and thus is not responsible for the fast lithium-ion diffusion in superionic conductors, as historically claimed. Instead, we find that materials with topologically isolated anion groups can enhance lithium-ion diffusivity via a more classic nondynamic soft-cradle mechanism, where the anion groups tilt to provide optimal coordination to a lithium ion throughout the hopping process to lower the migration barrier. This anion-group disorder is static in nature, rather than dynamic and can explain most of the experimental observations. Our work substantiates the nonexistence of the long-debated paddlewheel effect and clarifies any correlation that may exist between anion-group rotations and fast ionic diffusion in inorganic materials.

36 MATERIALS SCIENCE↗

Above-ground Antineutrino Detection for Nuclear Reactor Monitoring

Antineutrino monitoring of nuclear reactors has been demonstrated many times, however the technique has not as of yet been developed into a useful capability for treaty verification purposes. The most notable drawback is the current requirement that detectors be deployed underground, with at least several meters-water-equivalent of shielding from cosmic radiation. In addition, the deployment of liquid-based detector media presents a challenge in reactor facilities. We are currently developing a detector system that has the potential to operate above ground and circumvent deployment problems associated with a liquid detection media: the system is composed of segments of plastic scintillator surrounded by 6 LiF/ZnS:Ag. ZnS:Ag is a radio-luminescent phosphor used to detect the neutron capture products of lithium-6. Because of its long decay time compared to standard plastic scintillators, pulse-shape discrimination can be used to distinguish positron and neutron interactions resulting from the inverse beta decay (IBD) of antineutrinos within the detector volume, reducing both accidental and correlated backgrounds. Segmentation further reduces backgrounds by identifying the positron’s annihilation gammas, which are absent for most correlated and uncorrelated backgrounds. This work explores different configurations in order to maximize the size of the detector segments without reducing the intrinsic neutron detection efficiency. We believe this technology will ultimately be applicable to potential safeguards scenarios such as those recently described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron spectroscopy with {sup 6}LiF bolometers

A compact and semi-portable neutron detector has been built based on the bolometric technique. Its unique features open new possibilities for the radioprotection survey of fast neutrons at nuclear installations and the investigations of background problems of sensitive neutron scattering instruments. This cryogenic detector, operated at 300-400 mK, consists of a 0.5 g LiF 95%{sup 6}Li enriched crystal read out by a NTD-Ge sensor and is based on the {sup 6}Li(n, {alpha}){sup 3}H neutron capture reaction. It is used to define the energy of neutrons up to 5 MeV. Measurements with {sup 252}Cf source have been performed to determine the energy resolution of the detector. We report the first results obtained with this neutron detector. From developments made in view of the ROSEBUD (Rare Objects SEarch with Bolometers UndergrounD) collaboration we suggest a possible further improvement of the neutron detector by employing a combined heat and light detection. In the case of dark matter experiments, such a detector would allow to monitor the residual fast neutron component.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation neutron detectors based on solid-state photomultipliers and lightguides

Neutron detectors based on scintillation screens ZnS(Ag)/LiF and solid-state photomultipliers have been developed. Lightguides are used to collect light. The application of a coincidence scheme provides a low dark count and a neutron detection efficiency as high as 70%. A scheme of x-y neutron detector based on wavelength shifting fibers is also proposed. Tests of the proposed versions of detectors in a neutron beam have shown their efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient scalable solid-state neutron detector

We report on scalable solid-state neutron detector system that is specifically designed to yield high thermal neutron detection sensitivity. The basic detector unit in this system is made of a {sup 6}Li foil coupled to two crystalline silicon diodes. The theoretical intrinsic efficiency of a detector-unit is 23.8% and that of detector element comprising a stack of five detector-units is 60%. Based on the measured performance of this detector-unit, the performance of a detector system comprising a planar array of detector elements, scaled to encompass effective area of 0.43 m{sup 2}, is estimated to yield the minimum absolute efficiency required of radiological portal monitors used in homeland security.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Advancing Li-plating detection: Motivating a multi-signal correlation approach

Facilitating fast charging in lithium-ion batteries (LiBs) is often linked to Li-plating, which harms performance, longevity, and safety. Early detection of Li-plating is essential for rapid technological development and for preventing performance deterioration and ensuring safety during operation. Fast and real-time detection, using commonly collected measurements like voltage (V), current (I), temperature (T), and pressure (P), is highly desirable. Existing standalone methods relying on electrochemical and mechanical signatures, using half, smaller, or specially designed cells often operated at lower temperatures, fail to account for real-world fast-charging conditions. These signatures may also have inherent unreliability in aged LiBs, a phenomenon currently not-well understood. All these uncertainties have complicated practical implementation of a robust Li-plating detection technique. This study, through multiple case studies involving real-world fast-charging conditions using automotive-grade 11.6 Ah LiBs, shows that many single signal-based diagnostic techniques may be inadequate to detect Li-plating. Among various signatures, end-of-charge rest pressure, differential pressure-sensing, and end-of-charge rest voltage were identified as particularly useful in detecting Li-plating. Furthermore, A multi-signal-based detection technique is shown to be more robust in detecting Li-plating. Using both fresh and aged cells, the results and analysis highlight how detection capabilities are influenced by various factors, including battery design, size, charging speed, operating temperature, and degradation level. Adopting such a multi-signal Li-plating detection approach may be instrumental in the rapid development of battery technology in laboratories, as well as ensuring the enhanced safety of next-generation LiBs in real-world fast-charging applications.

25 ENERGY STORAGE↗

Pr{sup 3+}-doped fluoro-oxide lithium glass as scintillator for nuclear fusion diagnostics

Experimental results are presented on the neutron scintillating properties of a custom-designed Pr3+(praseodymium)-doped lithium (Li) glass. Luminescence was observed at 278 nm wavelength, originating from the 5d-4f transition. Time-resolved measurements yielded about 20 ns decay times for ultraviolet and x-ray excitation while much faster decay times of about 6 ns were observed for alpha particle and neutron excitation. Actual time-of-flight data in laser fusion experiments at the GEKKO XII facility of the Institute of Laser Engineering, Osaka University reveal that it can clearly discriminate fusion neutrons from the much stronger x-rays signals. This material can promise improved accuracy in future scattered neutron diagnostics.

36 MATERIALS SCIENCE↗

Down-scattered neutron imaging detector for areal density measurement of inertial confinement fusion

A custom developed {sup 6}Li glass scintillator (APLF80+3Pr) for down-scattered neutron diagnostics in inertial confinement fusion experiments is presented. {sup 6}Li provides an enhanced sensitivity for down-scattered neutrons in DD fusion and its experimentally observed 5-6 ns response time fulfills the requirement for down-scattered neutron detectors. A time-of-flight detector operating in the current mode using the APLF80+3Pr was designed and its feasibility observing down-scattered neutrons was demonstrated. Furthermore, a prototype design for a down-scattered neutron imaging detector was also demonstrated. This material promises viability as a future down-scattered neutron detector for the National Ignition Facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BD+15 2940 AND HD 233604: TWO GIANTS WITH PLANETS CLOSE TO THE ENGULFMENT ZONE

We report the discovery of planetary-mass companions to two red giants by the ongoing Penn State-Torun Planet Search (PTPS) conducted with the 9.2 m Hobby-Eberly Telescope. The 1.1 M{sub Sun} K0-giant, BD+15 2940, has a 1.1 M{sub J} minimum mass companion orbiting the star at a 137.5 day period in a 0.54 AU orbit what makes it the closest-in planet around a giant and possible subject of engulfment as the consequence of stellar evolution. HD 233604, a 1.5 M{sub Sun} K5-giant, is orbited by a 6.6 M{sub J} minimum mass planet which has a period of 192 days and a semi-major axis of only 0.75 AU making it one of the least distant planets to a giant star. The chemical composition analysis of HD 233604 reveals a relatively high {sup 7}Li abundance which may be a sign of its early evolutionary stage or recent engulfment of another planet in the system. We also present independent detections of planetary-mass companions to HD 209458 and HD 88133, and stellar activity-induced radial velocity variations in HD 166435, as part of the discussion of the observing and data analysis methods used in the PTPS project.

79 ASTRONOMY AND ASTROPHYSICS↗

Search for solar axion emission from {sup 7}Li and D(p, γ){sup 3}He nuclear decays with the CAST γ-ray calorimeter

We present the results of a search for a high-energy axion emission signal from {sup 7}Li (0.478 MeV) and D(p, γ){sup 3}He (5.5 MeV) nuclear transitions using a low-background γ-ray calorimeter during Phase I of the CAST experiment. These so-called ''hadronic axions'' could provide a solution to the long-standing strong-CP problem and can be emitted from the solar core from nuclear M1 transitions. This is the first such search for high-energy pseudoscalar bosons with couplings to nucleons conducted using a helioscope approach. No excess signal above background was found.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Polarization-sensitive electro-optic detection of terahertz wave using three different types of crystal symmetry: Toward broadband polarization spectroscopy

We investigated polarization-sensitive electro-optic (EO) detection of terahertz (THz) waves by using two uniaxial crystals: a c-cut gallium selenide and a c-cut lithium niobate crystals. We formulated a general frequency-domain description of EO detection by in-plane isotropic EO crystals, which holds regardless of the frequency. Based on this description, the polarization of THz waves can be derived by analyzing EO sampling signals measured with two orthogonal configurations of the in-plane isotropic EO crystals as well as typical (111) zinc-blende EO crystals. In addition, we experimentally demonstrated that the frequency-dependent polarization of THz waves can be reproducibly retrieved using three EO crystals with different crystal symmetries and with different phase matching conditions. Our description provides essential information for practical polarization sensing in the THz frequency range as well as in the mid-infrared range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Forbidden 2P–nP and 2P–nF transitions in the energy spectrum of ultracold Rydberg lithium-7 atoms

Forbidden 2P–nP and 2P–nF transitions in the ranges of the principal quantum number n = 42–114 and n = 38–48 have been detected in the optical spectra of ultracold highly excited lithium-7 atoms. The presence of forbidden transitions is due to induced external electric fields. The quantum defects and ionization energy obtained in various experiments and predicted theoretically have been discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Crystal growth of LiIn 1–x Ga x Se 2 crystals

Lithium containing chalcogenide single crystals have become very promising materials for photonics and radiation detection. Detection applications include nuclear nonproliferation, neutron science, and stellar investigations for the search of life. Synthesis and single crystal growth methods for lithium containing chalcogenide, specifically LiIn 1-x Ga x Se 2 , single crystals are discussed. This study elucidates the possibility of improving neutron detection by reducing the indium capture contribution; with the incorporation of the lithium-6 isotope, gallium substitution may overcome the neutron detection efficiency limitation of 6 LiInSe 2 due to appreciable neutron capture by the indium-115 isotope. As a figure of merit, the ternary parent compounds 6 LiInSe 2 and 6 LiGaSe 2 were included in this study. Quality crystals can be obtained utilizing the vertical Bridgman method to produce quaternary compounds with tunable optical properties. Here, quaternary crystals of varying quality depending on the gallium concentration, approximately 5 x 5 x 2 mm 3 or larger in volume, were harvested, analyzed and revealed tunable absorption characteristics between 2.8-3.4 eV.

36 MATERIALS SCIENCE↗

Infrared Signal Detection by Upconversion Technique

We demonstrated up-conversion assisted detection of a 2.05-micron signal by using a bulk periodically poled Lithium niobate crystal. The 94% intrinsic up-conversion efficiency and 22.58% overall detection efficiency at pW level of 2.05-micron was achieved.

Wong, Teh-Hwa↗