Response of the free surface of a cylindrically contained liquid to off-axis accelerations.
Linearized three-dimensional potential flow equations for response of liquids in cylindrical containers to slightly off-axis acceleration
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Linearized three-dimensional potential flow equations for response of liquids in cylindrical containers to slightly off-axis acceleration
The vestibulo-ocular reflexes (VOR) are determined not only by angular acceleration, but also by the presence of gravity and linear acceleration. This phenomenon was studied by measuring three-dimensional nystagmic eye movements, with implanted search coils, in six male squirrel monkeys during eccentric rotation. Monkeys were rotated in the dark at a constant velocity of 200 degrees/s (centrally or 79 cm off axis) with the axis of rotation always aligned with gravity and the spinal axis of the upright monkeys. The monkey's orientation (facing-motion or back-to-motion) had a dramatic influence on the VOR. These experiments show that: (a) the axis of eye rotation always shifted toward alignment with gravito-inertial force; (b) the peak value of horizontal slow phase eye velocity was greater with the monkey facing-motion than with back-to-motion; and (c) the time constant of horizontal eye movement decay was smaller with the monkey facing-motion than with back-to-motion. All of these findings were statistically significant and consistent across monkeys. In another set of tests, the same monkeys were rapidly tilted about their naso-occipital (roll) axis. Tilted orientations of 45 degrees and 90 degrees were maintained for 1 min. Other than a compensatory angular VOR during the angular rotation, no consistent eye velocity response was observed during or following the tilt for any of the six monkeys. The absence of any eye movement response following tilt weighs against the possibility that translational linear VOR responses are due to simple high-pass filtering of the otolith signals. The VOR response during eccentric rotation was divided into the more familiar angular VOR and linear VOR components. The angular component is known to depend upon semicircular canal dynamics and central influences. The linear component of the response decays rapidly with a mean duration of only 6.6 s, while the axis of eye rotation rapidly aligns (< 10 s) with gravito-inertial force. These results are consistent with the hypothesis that the measurement of gravito-inertial force by the otolith organs is resolved into central estimates of linear acceleration and gravity, such that the central estimate of gravitational force minus the central estimate of linear acceleration approximately equals the otolith measurement of gravito-inertial force.
Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present a theoretical derivation and the experimental validation of this result.
The effects of weightlessness on human orientation and balance are investigated. The responses of the Spacelab-1 crew to linear acceleration are measured using a perception of linear motion test, a closed-loop otolith assessment test (CLOAT), a dynamic ocular torsion test, and a lateral eye deviations test. The perception of linear motion tests measures a subject's ability to detect the presence and direction of small changes in linear acceleration; CLOAT assesses a person's ability to use linear acceleration cues to perform a manual control task; and the dynamic ocular torsion test examines the gravitoinertial contribution to dynamic ocular counterrolling. The threshold accelerations, velocity constants, regression coefficients, scalar performance measures, and torsion measurements for the subjects are analyzed and described. It is noted that the data support the tilt-translation reinterpretation hypothesis of Young et al. (1984, 1986).
Linear colliders rely on high-quality flat beams to achieve the desired event rate while avoiding potentially deleterious beamstrahlung effects. Here, we show that flat beams in plasma accelerators can be subject to quality degradation due to emittance mixing. This effect occurs when the beam particles' betatron oscillations in a nonlinearly coupled wakefield become resonant in the horizontal and vertical planes. Emittance mixing can lead to a substantial decrease of the luminosity, the main quantity determining the event rate. In some cases, the use of laser drivers or flat particle beam drivers may decrease the fraction of resonant particles and, hence, mitigate emittance deterioration.
Abstract Recent studies indicate better efficacy and healthy tissue sparing with high dose-rate FLASH radiotherapy (FLASH-RT) cancer treatment. This technique delivers a prompt high radiation dose rather than fractional doses over time. While some suggest thresholds of > 40 Gy s −1 with a maximal effect at > 100 Gy s −1 , accumulated evidence shows that instantaneous dose-rate and irradiation time are critical. Mechanisms are still debated, but toxicity is minimized while inducing apoptosis in malignant tissue. Delivery technologies to date show that a capability gap exists with clinic scale, broad area, deep penetrating, high dose rate systems. Based on these trends, if FLASH-RT is adopted, it may become a dominant approach except in the least technologically advanced countries. The linear induction accelerator (LIA) developed for high instantaneous and high average dose-rate, species independent charged particle acceleration, has yet to be considered for this application. We review the status of LIA technology, explore the physics of bremsstrahlung-converter-target interactions and our work on stabilizing the electron beam. While the gradient of the LIA is low, we present our preliminary work to improve the gradient by an order of magnitude, presenting a point design for a multibeam FLASH-RT system using a single accelerator for application to conformal FLASH-RT.
A ground-based simulator experiment was conducted to investigate the influence of simulator cue variations on helicopter autorotation landing-task performance. Using the NASA Ames Research Center Vertical Motion Simulator (VMS), variations were made in motion-system performance and selection of either longitudinal or lateral linear acceleration cues. Analysis of landing performance statistics and pilot commentary revealed that task performance changed with degraded motion cues. However, fixed base (no motion) could provide acceptable landing performance if adequate visual cues were present. Lontitudinal linear-acceleration cues assisted one pilot's control of the landing forward speed, while lateral linear-acceleration cues assisted in control of lateral drift or sideslip. Variations were also made in the content and details of visual landing scenes. Pilot commentary collected on the use of three landing scenes stressed the importance of receiving consistent, easily recognized, position, attitude, and speed cues from the visual scene. The importance of subtle aural cues to pilot acceptance of the simulation was also noted.
The current final report covers the period from June 1, 1999 to May 31, 2002. The primary objective of the investigation was to determine how information regarding head movements and head position relative to gravity is received and processed by central vestibular nuclei neurons in the brainstem. Specialized receptors in the vestibular labyrinths of the inner ear function to detect angular and linear accelerations of the head, with receptors located in the semicircular canals transducing rotational head movements and receptors located in the otolith organs transducing changes in head position relative to gravity or linear accelerations of the head. The information from these different receptors is then transmitted to central vestibular nuclei neurons which process the input signals, then project the appropriate output information to the eye, head, and body musculature motor neurons to control compensatory reflexes. Although a number of studies have reported on the responsiveness of vestibular nuclei neurons, it has not yet been possible to determine precisely how these cells combine the information from the different angular and linear acceleration receptors into a correct neural output signal. In the present project, rotational and linear motion stimuli were separately delivered while recording responses from vestibular nuclei neurons that were characterized according to direct input from the labyrinth and eye movement sensitivity. Responses from neurons receiving convergent input from the semicircular canals and otolith organs were quantified and compared to non-convergent neurons.
The responses of neck muscle to sudden transit from one 'g' to hyper 'g', work to support the head and remain the relative position of head on trunk as common observed: i.e. in sudden acceleration or deceleration by car or ejection of pilot from aircraft. Accordingly it is highly possible that the neck muscle responses to moving up may be important to prevent the neck injury due to sudden linear acceleration such as moving up against gravity. However little is known about the evaluation of mechanism of this reflex. Therefore the present study was conducted with two aims. The first aim was to investigate the neck muscle responses to vertical linear acceleration bv 0.4 g produced with an electro-hydraulic servo-system. We chose the vertical linear acceleration because it activates mainly sacculus, from which afferents have been demonstrated to be connected directly to sternocleidomastoid muscle in animals and human. The second aim was to determine whether there is a difference of neck muscle response to moving down and moving up.
Energy-frontier particle accelerators are among the most exciting, complex, challenging, and expensive research instruments performing high precision measurements confirming the fundamentals of the physics and broadening new research horizons. Currently the highest energy machines (under design or commissioned), from multi-GeV to several TeV, (ILC, FCC, CLIC) capable of searching for the most basic building blocks of matter are either driven by circular or linear accelerators [1-6]. Here (see also [7,8]) we suggest a novel design of circular-linear accelerator based on the merging of the weakly emitting, low-energy storage rings and energy recovery linear accelerators. To enable the operation of such a system and in particular the energy recovery from spent, high-intensity beams the use of the dual-axis asymmetric cavities is suggested. Merging circular and linear systems, and applications of dual axes cavities, aims to resolve both scientific and societal challenges. The merge of the systems will allow: 1) maintain high beam quality, high luminosity, and high energy efficiency; 2) offer a ?flexible? energy management via ?separation? of the collider and storage rings operations; 3) attract private partners via use of the storage rings to drive the next generation of the photon factories. The concept presented can be potentially used to reach ultimate energy frontiers in high-energy physics as well as to drive next generation light sources. We note that the numbers which will be presented are for illustration purpose and can be improved further.
The rim inertial measuring system (RIMS) is introduced and an approach for extracting angular rate and linear acceleration information from a RIMS unit is presented and discussed. The RIMS consists of one or more small annular momentum control devices (AMCDs), mounted in a strapped down configuration, which are used to measure angular rates and linear accelerations of a moving vehicle. An AMCD consists of a spinning rim, a set of noncontacting magnetic bearings for supporting the rim, and a noncontacting electromagnetic spin motor. The approach for extracting angular rate and linear acceleration information is for a single spacecraft mounted RIMS unit.
Explore the source record for details and available documents.
Changes in levels of plasma vasopressin (AVP) and cortisol (C) have been shown to be correlated with motion sickness and nausea in man. As part of the research aimed at validation of the cat as an appropriate animal model for motion sickness research, levels of these hormones were investigated in the cat during motion sickness elicited by vertical linear acceleration of approximately 0.6 Hz and 1 +/- 0.6 G. In Study 1, 15 cats previously screened for susceptibility to motion sickness were prepared with indwelling jugular catheters to permit withdrawl of blood with minimal disruption of the stimulus and minimum stress to the animal. AVP and C were measured in blood samples obtained during exposure to vertical linear acceleration and during control sessions in which the animals were placed in the stationary apparatus. 10 min and 1 min prior to duration; 1, 5, 10, and 20 min after start of motion. Total duration of exposure to motion was 20 min. The data indicate that both AVP and C are elevated during exposure to motion if emesis occurs. AVP reaches maximum levels during or about the same time as emesis, while C increases gradually throughout the period of vertical acceleration. In Study 2, four cats were prepared with indwelling catheters and AVP was measured in blood withdrawn during exposure to the vertical linear acceleration. A single pre-motion sample consisting of three samples drawn 5 min prior to motion onset. Two series of samples consisting of three samples drawn at 3-min intervals were obtained during motion. The first series was initiated at emesis, and the second 25 min after emesis. Results show that levels of circulating AVP were elevated (2 to 27 times the control and pre-motion levels) in the samples taken during emesis and decreased, but remained 1 to 6 times above the pre-motion or control levels within 25 min. The results of these two studies indicate that AVP is elevated during motion-produced emesis than is C. These findings are in general agreement with those obtained from humans under motion sickness conditions, and indicate that it is appropriate to continue to use the cat in studies of hormone changes during motion sickness.
During linear accelerations, compensatory reflexes should continually occur in order to maintain objects of visual interest as stable images on the retina. In the present study, the three-dimensional organization of the vestibulo-ocular reflex in pigeons was quantitatively examined during linear accelerations produced by constant velocity off-vertical axis yaw rotations and translational motion in darkness. With off-vertical axis rotations, sinusoidally modulated eye-position and velocity responses were observed in all three components, with the vertical and torsional eye movements predominating the response. Peak torsional and vertical eye positions occurred when the head was oriented with the lateral visual axis of the right eye directed orthogonal to or aligned with the gravity vector, respectively. No steady-state horizontal nystagmus was obtained with any of the rotational velocities (8-58 degrees /s) tested. During translational motion, delivered along or perpendicular to the lateral visual axis, vertical and torsional eye movements were elicited. No significant horizontal eye movements were observed during lateral translation at frequencies up to 3 Hz. These responses suggest that, in pigeons, all linear accelerations generate eye movements that are compensatory to the direction of actual or perceived tilt of the head relative to gravity. In contrast, no translational horizontal eye movements, which are known to be compensatory to lateral translational motion in primates, were observed under the present experimental conditions.
Transient linear acceleration stimuli have been shown to elicit eighth nerve vestibular compound action potentials in birds and mammals. The present study was undertaken to better define the nature of the adequate stimulus for neurons generating the response in the chicken (Gallus domesticus). In particular, the study evaluated the question of whether the neurons studied are most sensitive to the maximum level of linear acceleration achieved or to the rate of change in acceleration (da/dt, or jerk). To do this, vestibular response thresholds were measured as a function of stimulus onset slope. Traditional computer signal averaging was used to record responses to pulsed linear acceleration stimuli. Stimulus onset slope was systematically varied. Acceleration thresholds decreased with increasing stimulus onset slope (decreasing stimulus rise time). When stimuli were expressed in units of jerk (g/ms), thresholds were virtually constant for all stimulus rise times. Moreover, stimuli having identical jerk magnitudes but widely varying peak acceleration levels produced virtually identical responses. Vestibular response thresholds, latencies and amplitudes appear to be determined strictly by stimulus jerk magnitudes. Stimulus attributes such as peak acceleration or rise time alone do not provide sufficient information to predict response parameter quantities. Indeed, the major response parameters were shown to be virtually independent of peak acceleration levels or rise time when these stimulus features were isolated and considered separately. It is concluded that the neurons generating short latency vestibular evoked potentials do so as "jerk encoders" in the chicken. Primary afferents classified as "irregular", and which traditionally fall into the broad category of "dynamic" or "phasic" neurons, would seem to be the most likely candidates for the neural generators of short latency vestibular compound action potentials.
It has been proposed that a vestibular reflex originating in the otolith organs and other body graviceptors modulates sympathetic activity during changes in posture with regard to gravity. To test this hypothesis, we selectively stimulated otolith and body graviceptors sinusoidally along different head axes in the coronal plane with off-vertical axis rotation (OVAR) and recorded sympathetic efferent activity in the peroneal nerve (muscle sympathetic nerve activity, MSNA), blood pressure, heart rate, and respiratory rate. All parameters were entrained during OVAR at the frequency of rotation, with MSNA increasing in nose-up positions during forward linear acceleration and decreasing when nose-down. MSNA was correlated closely with blood pressure when subjects were within +/-90 degrees of nose-down positions with a delay of 1.4 s, the normal latency of baroreflex-driven changes in MSNA. Thus, in the nose-down position, MSNA was probably driven by baroreflex afferents. In contrast, when subjects were within +/-45 degrees of the nose-up position, i.e., when positive linear acceleration was maximal along the naso-ocipital axis, MSNA was closely related to gravitational acceleration at a latency of 0.4 s. This delay is too short for MSNA changes to be mediated by the baroreflex, but it is compatible with the delay of a response originating in the vestibular system. We postulate that a vestibulosympathetic reflex, probably originating mainly in the otolith organs, contributes to blood pressure maintenance during forward linear acceleration. Because of its short latency, this reflex may be one of the earliest mechanisms to sustain blood pressure upon standing.
Flash radiography of hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories. At Los Alamos, the DualAxis Radiographic Hydrodynamic Test (DARHT) facility two linear induction electron accelerators (LIAs) make the bremsstrahlung radiographic source spots for point projection radiographs from orthogonal views. A new LIA, called Scorpius, is presently under development to advance this technology. To better understand electron-beam physics in these LIAs, numerical simulations are frequently performed with the objective of improving the radiography. At Los Alamos we frequently use the TRAK ray-trace and LSP particle-in-cell (PIC) codes to simulate the injector, and the XTR and LAMDA envelope/centroid codes along with LSP to simulate transport of the accelerated beam through the LIAs. The LIA simulations need the injected beam parameters as initial conditions for calculating beam transport and stability. The determination of these initial conditions is the topic of this note.
Flash radiography of hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories. At Los Alamos, the Dual Axis Radiographic Hydrodynamic Test (DARHT) facility two linear induction electron accelerators (LIAs) make the bremsstrahlung radiographic source spots for point projection radiographs from orthogonal views. A new LIA, called Scorpius, is presently under development to advance this technology. To better understand electron-beam physics in these LIAs, numerical simulations are frequently performed with the objective of improving the radiography. At Los Alamos we frequently use the TRAK ray-trace and LSP particle-in-cell (PIC) codes to simulate the injector, and the XTR and LAMDA envelope/centroid codes along with LSP to simulate transport of the accelerated beam through the LIAs. The LIA simulations need the injected beam parameters as initial conditions for calculating beam transport and stability. The determination of these initial conditions is the topic of this note.