Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light sensitive materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

SMM coronagraph observations of particulate contamination

Some recent images taken by the white light coronagraph telescope aboard the Solar Maximum Mission (SMM) observatory show bright streaks that are apparently caused by particles associated with the spacecraft. In this report we describe these observations, and we analyze the times of their occurrence. We demonstrate that the sightings occur most often near SMM's orbital dawn, and we speculate that thermal shock is the mechanism that produces the particles. Although these sightings have not seriously affected the coronagraph's scientific operations, the unexpected passage of bright material through the field of view of sensitive spaceborne telescopes can lead to data loss or, in some cases, serious detector damage. The topic of space debris has become a significant concern for designers of both manned and unmanned orbiting platforms. The returned samples from the SMM spacecraft and the observations reported here provide a baseline of experience for future orbital platforms that plan long duration missions.

St. Cyr, O. C.↗

Effect of Altered Gravity Environment on Tobacco Hornworm (Manduca Sexta) Development

Metamorphosis provides a unique condition for studying the role of gravity in development. Formation of new organs in a previously existing organism requires a highly active period of turnover of amino acids and proteins, and of changes in the endocrine profile. Furthermore, metamorphosis offers the advantage of studying a self-contained biological system. The tobacco hornworm provides a suitable species to study the effect of altered gravitational environment on invertebrate development. This species has been one of the most thoroughly investigated organisms in a variety of aspects of insect biology. M. sexta pharate adults can provide significant amounts of material with which to work, thus facilitating the study of metabolic aspects of adult development. During wandering, the period immediately following cessation of larval feeding, the larva burrows into the soil to form a pupation chamber. Despite burrowing down 25 to 30 cm, the insects reorient themselves to a slightly head-up (10 +/- 1 degree) position. Since light and temperature are not factors in this process, the larvae must sense the gravity vector. In our ground-based studies we had assessed whether developing adults might be sensitive to their gravitational environment by orienting pupae in a vertical head-up position within 24 to 48 h after pupal ecdysis. Our ground-based findings formed the foundation for determining which parameters would be evaluated in developing Manduca following spaceflight. Measurements were to include: (1) extent of development by all of the insects, (2) analysis of hemolymph obtained from half of the insects postflight for ecdysteroid, amino acid, urea, ammonia and trehalose concentrations, (3) further development of the other half of the insects to adult (moths), (4) analysis of the flight muscle protein content of the adults. Based on the first flight attempt in July, 1995, we modified the BRIC hardware to accommodate the insects. Our studies after BRIC-04 showed that sealing the top and bottom lids of the canisters with an 0-ring and with vacuum grease caused the insects to stop developing because of accumulation of carbon dioxide. Even though removing both the O-rings and vacuum grease permitted normal development, there was still some increase in carbon dioxide levels. Consequently, the canisters were vented and the vents covered with gas permeable membrane.

Tischler, Marc E.↗

An in Situ Technique for Elemental Analysis of Lunar Surfaces

An in situ analytical technique that can remotely determine the elemental constituents of solids has been demonstrated. Laser-Induced Breakdown Spectroscopy (LIBS) is a form of atomic emission spectroscopy in which a powerful laser pulse is focused on a solid to generate a laser spark, or microplasma. Material in the plasma is vaporized, and the resulting atoms are excited to emit light. The light is spectrally resolved to identify the emitting species. LIBS is a simple technique that can be automated for inclusion aboard a remotely operated vehicle. Since only optical access to a sample is required, areas inaccessible to a rover can be analyzed remotely. A single laser spark both vaporizes and excites the sample so that near real-time analysis (a few minutes) is possible. This technique provides simultaneous multielement detection and has good sensitivity for many elements. LIBS also eliminates the need for sample retrieval and preparation preventing possible sample contamination. These qualities make the LIBS technique uniquely suited for use in the lunar environment.

Kane, K. Y.↗

A Closer Look at Solar Wind Sputtering of Lunar Surface Materials

Solar-wind induced potential sputtering of the lunar surface may be a more efficient erosive mechanism than the "standard" kinetic (or physical) sputtering. This is partly based on new but limited laboratory measurements which show marked enhancements in the sputter yields of slow-moving, highly-charged ions impacting oxides. The enhancements seen in the laboratory can be orders of magnitude for some surfaces and highly charged incident ions, but seem to depend very sensitively on the properties of the impacted surface in addition to the fluence, energy and charge of the impacting ion. For oxides, potential sputtering yields are markedly enhanced and sputtered species, especially hydrogen and light ions, show marked dependence on both charge and dose.

Barghouty, A. F.↗

Light-Flash Wind-Direction Indicator

Proposed wind-direction indicator read easily by distant observers. Indicator emits bright flashes of light separated by interval of time proportional to angle between true north and direction from which wind blowing. Timing of flashes indicates direction of wind. Flashes, from high-intensity stroboscopic lights seen by viewers at distances up to 5 miles or more. Also seen more easily through rain and fog. Indicator self-contained, requiring no connections to other equipment. Power demand satisfied by battery or solar power or both. Set up quickly to provide local surface-wind data for aircraft pilots during landing or hovering, for safety officers establishing hazard zones and safety corridors during handling of toxic materials, for foresters and firefighters conducting controlled burns, and for real-time wind observations during any of variety of wind-sensitive operations.

Zysko, Jan A.↗

Differential Radiometers Using Fabry-Perot Interferometric Technique for Remote Sensing Determination of Various Atmospheric Trace Gases

New type of remote sensing instrument based upon the Fabry-Perot inte rferometric technique has been developed at NASA's Goddard Space Flight Center. Fabry-Perot interferometry (FPI) is a well known, powerful spectroscopic technique and one of its many applications is to be use d to measure greenhouse gases and also some harmful species in the at mosphere. With this technique, absorption of particular species is me asured and related to its concentration. A solid Fabry-Perot etalon is used as a frequency filter to restrict the measurement to particular absorption bands of the gas of interest. With adjusting the thicknes s of the etalon that separation (in frequency) of the transmitted fri nges can be made equal to the almost constant separation of the gas a bsorption lines. By adjusting the temperature of the etalon, which changes the index of refi-action of its material, the transmission fring es can be brought into nearly exact correspondence with absorption li nes of the particular species. With this alignment between absorption lines and fringes, changes in the amount of a species in the atmosph ere strongly affect the amount of light transmitted by the etalon and can be related to gas concentration. The instrument that we have dev eloped detects the absorption of various atmospheric trace gases in d irect or reflected sunlight. Our instrument employing Fabry-Perot interferometer makes use of two features to achieve high sensitivity. The first is high spectral resolution enabling one to match the width of an atmospheric absorption feature by the instrumental band pass. The second is high optical throughput enabled by using multiple spectral lines simultaneously. For any species that one wishes to measure, thi s first feature is available while the use of multiple spectral features can be employed only for species with suitable spectra and freedom from interfering species in the same wavelength region. We have deve loped an instrument for use as ground based, airborne and satellite s ensor for gases such as carbon dioxide (1570 nm), oxygen (762 nm and 768 nm lines sensitive to changes in oxygen pressure and oxygen temper ature) and water vapor (940 nm). Our current goal is to develop an ul tra precise, inexpensive, ground based device suitable for wide deplo yment as a validation instrument for the Orbiting Carbon Observatory (OCO) satellite. We show sensitivity measurements for CO2, 02, and H2 O, compare our measurements to those obtained using other types of sensors and discuss some of the peculiarities that must be addressed in order to provide the very high quality column detection required for solving problems about global distribution of greenhouse gases and cl imatological models. In another area of research we are interested in developing a small-size channel for CO2 capable of doing simultaneous measurements with the AERONET (Aerosol Robotic Network) at NASA, God dard to study the hypothesis that atmospheric aerosols affect the reg ional terrestrial carbon cycle. We present recent data from our groun d based measurements of O2, CO2, H2O and (13)CO2 and discuss extensio n of the technique to new species and applications.

Georgieva, E. M.↗

Deep HST/STIS Visible-Light Imaging of Debris Systems Around Solar Analog Hosts

We present new Hubble Space Telescope observations of three a priori known starlight-scattering circumstellar debris systems (CDSs) viewed at intermediate inclinations around nearby close-solar analog stars: HD 207129, HD202628, and HD 202917. Each of these CDSs possesses ring-like components that are more massive analogs of our solar systems Edgeworth Kuiper Belt. These systems were chosen for follow-up observations to provide imaging with higher fidelity and better sensitivity for the sparse sample of solar-analog CDSs that range over two decades in systemic ages, with HD 202628 and HD 207129 (both approx. 2.3 Gyr) currently the oldest CDSs imaged in visible or near-IR light. These deep (10-14 ks) observations, made with six-roll point-spread-function template visible-light coronagraphy using the Space Telescope Imaging Spectrograph, were designed to better reveal their angularly large debris rings of diffuse low surface brightness, and for all targets probe their exo-ring environments for starlight-scattering materials that present observational challenges for current ground-based facilities and instruments. Contemporaneously also observing with a narrower occulter position, these observations additionally probe the CDS endo-ring environments that are seen to be relatively devoid of scatterers. We discuss the morphological, geometrical, and photometric properties of these CDSs also in the context of other CDSs hosted by FGK stars that we have previously imaged as a homogeneously observed ensemble. From this combined sample we report a general decay in quiescent-disk F disk /F star optical brightness approx. t( exp.-0.8), similar to what is seen at thermal IR wavelengths, and CDSs with a significant diversity in scattering phase asymmetries, and spatial distributions of their starlight-scattering grains.

starlight-scattering circumstellar debris systems ↗

An Overview of the Patch Integral Method (PIM), a New Heat Transfer Analysis Tool for Hypersonic Wind Tunnel Facilities at NASA Langley

NASA Langley’s hypersonic wind tunnels are heavily leveraged for planetary missions. The data collection method in these tunnels is thermography, and surface temperature measurements of the model surface are collected and reduced to produce surface heating data, as seen in Fig 1. However, during model injection, no temperature data are collected, and thus conventional, integral heat transfer methods cannot be used to solve for surface heating. A method was developed in the 1990’s to reduce this data despite the data gap, known as the step approximation method. The method assumes that the film coefficient behaves as a step function, the model is semi-infinite, and thermal properties are constant. With these simplifying assumptions, a Laplace transform can be performed to result in an equation that takes the initial temperature of the model and a temperature at some point in time to back out the film coefficient at that time. This is the method that is used in the current thermographic data reduction software, IHEAT. While computationally light-weight, the step approximation has several issues associated with it. The time-history of temperature is not accounted for, which is vital as heat transfer is an integral process. Additionally, the required semi-infinite assumption is unnecessary and might be violated during runtime. Thermal variation of material properties can have a sizeable impact on heating results and are not modeled by the method. This method also takes multiple seconds to “collapse” to a steady state, which is undesirable from both a facility and data reduction standpoint. The method is also very sensitive to the “effective time” approximation, an approximation of when heating instantaneously starts (which is a nonphysical simplification), and a small variation in this value can result in an error in heating results.

J. S. Cheatwood↗

Isotopic investigations in the area of the Tunguska catastrophe in 1908 year

The hypotheses of the annihilation and thermonuclear character of the Tunguska explosion have been tested by measuring inductive Ar-39 radioactivity from K and Ca in rocks and soil under the explosion epicentrum. Ar-39 was not detected though its estimated radioactivity was expected to be 100 times higher than the radio-metrical plant sensitivity. These results testify against the nuclear nature of the Tunguska explosion. The contents of 11 elements in the ultrasmall quantity of matter of the silicate microspherules isolated from catastrophe peat layer at the explosion site were measured by method of neutron activation analysis. It was demonstrated that the enrichment of microspherules by light and volatile elements (Al, Na, Zn, Cs) and the impoverishment by more heavy and hard volatile ones (Fe, Co, Sc). It was shown that the microspherules were not the product of differentiation of the terrestrial soil or of an ordinary meteorite material. It was demonstrated that Pb isotopic content in catastrophe peat layer had more Pb-204, Pb-207, Pb-208 than Pb-206 as compared with Pb isotopic content of other peat layers and common Pb in this area. In the peat column taken at the Ostraya hill area in three nearcatastrophe layers, small increases of isotopic C-13 was determined. Isotopic C effect in the peat layer is confirmed also for the North peatbog. Observed isotopic changes are not accounted for by climatic changes or other physico-chemical reasons. They seem to be related to preservation in the peat of matter resembling carbonaceous chrondrites of the Cl type or more probably of cometary matter enriched much more in volatile elements.

Kolesnikov, E. M.↗

New Active Optical Technique Developed for Measuring Low-Earth-Orbit Atomic Oxygen Erosion of Polymers

Polymers such as polyimide Kapton (DuPont) and Teflon FEP (DuPont, fluorinated ethylene propylene) are commonly used spacecraft materials because of desirable properties such as flexibility, low density, and in the case of FEP, a low solar absorptance and high thermal emittance. Polymers on the exterior of spacecraft in the low-Earth-orbit (LEO) environment are exposed to energetic atomic oxygen. Atomic oxygen reaction with polymers causes erosion, which is a threat to spacecraft performance and durability. It is, therefore, important to understand the atomic oxygen erosion yield E (the volume loss per incident oxygen atom) of polymers being considered in spacecraft design. The most common technique for determining E is a passive technique based on mass-loss measurements of samples exposed to LEO atomic oxygen during a space flight experiment. There are certain disadvantages to this technique. First, because it is passive, data are not obtained until after the flight is completed. Also, obtaining the preflight and postflight mass measurements is complicated by the fact that many polymers absorb water and, therefore, the mass change due to water absorption can affect the E data. This is particularly true for experiments that receive low atomic oxygen exposures or for samples that have a very low E. An active atomic oxygen erosion technique based on optical measurements has been developed that has certain advantages over the mass-loss technique. This in situ technique can simultaneously provide the erosion yield data on orbit and the atomic oxygen exposure fluence, which is needed for erosion yield determination. In the optical technique, either sunlight or artificial light can be used to measure the erosion of semitransparent or opaque polymers as a result of atomic oxygen attack. The technique is simple and adaptable to a rather wide range of polymers, providing that they have a sufficiently high optical absorption coefficient. If one covers a photodiode with a uniformly thick sheet of semitransparent polymer such as Kapton H polyimide, then as atomic oxygen erodes the polymer, the short-circuit current from the photodiode will increase in an exponential manner with fluence. This nonlinear response with fluence results in a lack of sensitivity for measuring low atomic oxygen fluences. However, if one uses a variable-thickness polymer or carbon sample, which is configured as shown in the preceding figure, then a linear response can be achieved for opaque materials using a parabolic well for a circular geometry detector or a V-shaped well for a rectangular-geometry detector. Variable-thickness samples can be fabricated using many thin polymer layers. For semitransparent polymers such as Kapton H polyimide, there is an initial short-circuit current that is greater than zero. This current has a slightly nonlinear dependence on atomic oxygen fluence in comparison to opaque materials such as black Kapton as shown in the graph. For this graph figure, the total thickness of Kapton H was assumed to be 0.03 cm. The photodiode short-circuit current shown in the graph was generated on the basis of preliminary measurements-a total reflectance rho of 0.0424 and an optical absorption coefficient a of 146.5 cm(sup -1). In addition to obtaining on-orbit data, the advantage of this active erosion and erosion yield measurement technique is its simplicity and reliance upon well-characterized fluence witness materials as well as a nearly linear photodiode short-circuit current dependence upon atomic oxygen fluence. The optical technique is useful for measuring either atomic oxygen fluence or erosion, depending on the information desired. To measure the atomic oxygen erosion yield of a test material, one would need to have two photodiode sensors, one for the test material and one that uses a known erosion yield material (such as Kapton) to measure the atomic oxygen fluence.

Banks, Bruce A.↗

Sensitivity analysis of high-efficiency silicon solar-cell design parameters

Silicon solar cell design parameters were investigated to determine their bearing on cell efficiency. Among the parameters reviewed were: (1) bulk resistivity, (2) minority carrier lifetime cell thickness, (3) front junction depth, (4) front surface doping concentration, (5) front surface recombination velocity, and (6) back surface contact. The following were concluded: (1) there is good agreement between experimental and simulation results; (2) sheet material quality improvement is needed for high efficiency cells; (3) 20% cell of this design is feasible with 10 ms bulk lifetime material; and (4) for achieving efficiencies higher than 20% new cell designs including thin cells with light trapping and back surface field should be considered.

Mokashi, A. R.↗

Comparison of Models for Ball Bearing Dynamic Capacity and Life

Generalized formulations for dynamic capacity and life of ball bearings, based on the models introduced by Lundberg and Palmgren and Zaretsky, have been developed and implemented in the bearing dynamics computer code, ADORE. Unlike the original Lundberg-Palmgren dynamic capacity equation, where the elastic properties are part of the life constant, the generalized formulations permit variation of elastic properties of the interacting materials. The newly updated Lundberg-Palmgren model allows prediction of life as a function of elastic properties. For elastic properties similar to those of AISI 52100 bearing steel, both the original and updated Lundberg-Palmgren models provide identical results. A comparison between the Lundberg-Palmgren and the Zaretsky models shows that at relatively light loads the Zaretsky model predicts a much higher life than the Lundberg-Palmgren model. As the load increases, the Zaretsky model provides a much faster drop off in life. This is because the Zaretsky model is much more sensitive to load than the Lundberg-Palmgren model. The generalized implementation where all model parameters can be varied provides an effective tool for future model validation and enhancement in bearing life prediction capabilities.

Rolling-element Fatigue↗

Differential Radiometers Using Fabry-Perot Interferometric Technique for Remote Sensing of Greenhouse Gases

A new type of remote sensing radiometer based upon the Fabry-Perot interferometric technique has been developed at NASA's Goddard Space Flight Center and tested from both ground and aircraft platform. The sensor uses direct or reflected sunlight and has channels for measuring column concentration of carbon dioxide at 1570 nm, oxygen lines sensitive to pressure and temperature at 762 and 768 nm, and water vapor (940 nm). A solid Fabry-Perot etalon is used as a tunable narrow bandpass filter to restrict the measurement to the gas of interest's absorption bands. By adjusting the temperature of the etalon, which changes the index of refraction of its material, the transmission fringes can be brought into nearly exact correspondence with absorption lines of the particular species. With this alignment between absorption lines and fringes, changes in the amount of a species in the atmosphere strongly affect the amount of light transmitted by the etalon and can be related to gas concentration. The technique is applicable to different chemical species. We have performed simulations and instrument design studies for CH4, "Cot isotope, and CO detection. Index Terms- Absorbing media, Atmospheric measurements, Fabry-Perot interferometers, Optical interferometry, Remote sensing.

Georgieva, Elena M.↗

Instrument for Measuring Temperature of Water

A pseudo-Brewster-angle infrared radiometer has been proposed for use in noncontact measurement of the surface temperature of a large body of water (e.g., a lake or ocean). This radiometer could be situated on a waterborne, airborne, or spaceborne platform. The design of the pseudo-Brewster-angle radiometer would exploit the spectral-emissivity and polarization characteristics of water to minimize errors attributable to the emissivity of water and to the reflection of downwelling (e.g., Solar and cloud-reflected) infrared radiation. The relevant emissivity and polarization characteristics are the following: . The Brewster angle is the angle at which light polarized parallel to the plane of incidence on a purely dielectric material is not reflected. The pseudo-Brewster angle, defined for a lossy dielectric (somewhat electrically conductive) material, is the angle for which the reflectivity for parallel-polarized light is minimized. For pure water, the reflectivity for parallel-polarized light is only 2.2 x 10(exp -4) at its pseudo- Brewster angle of 51deg. The reflectivity remains near zero, several degrees off from the 51deg optimum, allowing this angle of incidence requirement to be easily achieved. . The wavelength range of interest for measuring water temperatures is 8 to 12 microns. The emissivity of water for parallel- polarized light at the pseudo-Brewster angle is greater than 0.999 in this wavelength range. The radiometer would be sensitive in the wavelength range of 8 to 12 microns, would be equipped with a polarizer to discriminate against infrared light polarized perpendicular to the plane of incidence, and would be aimed toward a body of water at the pseudo- Brewster angle (see figure). Because the infrared radiation entering the radiometer would be polarized parallel to the plane of incidence and because very little downwelling parallel-polarized radiation would be reflected into the radiometer on account of the pseudo-Brewster arrangement, the radiation received by the radiometer would consist almost entirely of thermal emission from the surface of the water. Because the emissivity of the water would be very close to 1, the water could be regarded as a close approximation of a blackbody for the purpose of computing its surface temperature from the radiometer measurements by use of the Planck radiation law.

Ryan, Robert↗

Feasibility of using Low-Cost COTS Sensors for Particulate Monitoring in Space Missions

Real-time measurement of particles suspended in the spacecraft cabin is of great importance to verify that maximum allowable dust concentrations are not exceeded. This is primarily to protect astronaut health, but also has implications for dust-sensitive equipment. Recently, there is growing interest in low-cost commercial off-the-shelf (COTS) particle sensors by air quality researchers for their ability to map concentrations of airborne particulate matter in various terrestrial settings. In addition to low cost (< $2,000), the compact size and minimal weight of these sensors make them a potential choice for space missions. The detection mechanism for these aerosol sensors is typically measurement of light scattered by particles as they flow through a sensing volume. The amount of scattered light for detection depends on the particle size, shape, density, and refractive index of the particle material. Ideally, particle instruments should be calibrated with reference instruments for each different type of aerosol measurement. In this study we review multiple parameters that may impact the performance of state-of-the-art low-cost aerosol sensors. Environmental factors such as temperature, relative humidity, low ambient pressure, radiation and charge environment, partial-gravity and microgravity can affect the accuracy of particle measurements. Characteristics of the dust aerosols including particle size distribution, aerosol composition, refractive index, morphology and concentration levels also affect the measurement accuracy. Finally, we look at these parameters and issues with respect to an example COTS low-cost aerosol sensor. Instrument performance specifications are evaluated, and experiments are performed to measure real-time concentrations of Arizona Road Dust (a terrestrial reference test dust) and lunar dust simulant in a laboratory chamber. Overall, this study provides insight for evaluating spacecraft particulate monitoring technologies and raises questions to be answered before incorporating low-cost COTS sensors in future space missions to dusty destinations.

lunar dust↗

Space Application Requirements for Organic Avionics

The NASA Marshall Space Flight Center is currently evaluating polymer based components for application in launch vehicle and propulsion system avionics systems. Organic polymers offer great advantages over inorganic corollaries. Unlike inorganics with crystalline structures defining their sensing characteristics, organic polymers can be engineered to provide varying degrees of sensitivity for various parameters including electro-optic response, second harmonic generation, and piezoelectric response. While great advantages in performance can be achieved with organic polymers, survivability in the operational environment is a key aspect for their practical application. The space environment in particular offers challenges that must be considered in the application of polymer based devices. These challenges include: long term thermal stability for long duration missions, extreme thermal cycling, space radiation tolerance, vacuum operation, low power operation, high operational reliability. Requirements for application of polymer based devices in space avionics systems will be presented and discussed in light of current polymer materials.

Watson, Michael D.↗

Colloids in Microgravity

Colloidal particles are important in a broad range of applications in technology and materials processing. Due to high sensitivity to thermal fluctuations, a suspension of colloidal particles is considered as an assembly of super-atoms in condensed matter physics. This feature provides an excellent experimental model in statistical mechanics for fundamental studies of microstructural evolution and phase transformation at the individual particle level. However, using colloids to probe three-dimensional phase transitions on Earth remains a challenge as they can be influenced by the gravity force causing the particles to sediment and the solvent to flow. To suppress the undesirable gravity effects, experiments on concentrated colloids were carried out in the International Space Station (ISS) Light Microscopy Module. We will present results of these experiments.

Colloids↗

Resistivity and thickness effects in dendritic web silicon solar cells

The decrease of minority carrier lifetime as resistivity decreases in dendritic-web silicon solar cells is addressed. This variation is shown to be consistent with the presence of defect levels in the bandgap which arise from extended defects in the web material. The extended defects are oxide precipitates (SiOx) and the dislocation cores they decorate. Sensitivity to this background distribution of defect levels increases with doping because the Fermi level moves closer to the majority carrier band edge. For high-resistivity dendritic-web silicon, which has a low concentration of these extended defects, cell efficiencies as high as 16.6 percent (4 sq cm, 40 ohm-cm boron-doped base, AM1.5 global, 100 mW/sq cm, 25 C JPL LAPSS1 measurement) and a corresponding electron lifetime of 38 microsec have been obtained. Thickness effects occur in bifacial cell designs and in designs which use light trapping. In some cases, the dislocation/precipitate defect can be passivated through the full thickness of web cells by hydrogen ion implantation.

Meier, D. L.↗