Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “life testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Vapor Compression Distillation Urine Processor Lessons Learned from Development and Life Testing

Vapor Compression Distillation (VCD) is the chosen technology for urine processing aboard the International Space Station (155). Development and life testing over the past several years have brought to the forefront problems and solutions for the VCD technology. Testing between 1992 and 1998 has been instrumental in developing estimates of hardware life and reliability. It has also helped improve the hardware design in ways that either correct existing problems or enhance the existing design of the hardware. The testing has increased the confidence in the VCD technology and reduced technical and programmatic risks. This paper summarizes the test results and changes that have been made to the VCD design.

Hutchens, Cindy F.↗

Life test results for the advanced very high resolution radiometer scanner

The following paper reports the results obtained during a 3.33-year life test on the TIROS Advanced Very High Resolution Radiometer/3 (AVHRR/3) Scanner. The bearing drag torque and lubricant loss over life will be compared to predicted values developed through modeling. The condition of the lubricant at the end of the test will be described and a theory presented to explain the results obtained. The differences (if any) in the predicted and measured values of drag torque and lubricant loss will be discussed and possible reasons for these examined.

Lenz, James↗

The Role of Bearing and Scan Mechanism Life Testing in Flight Qualification of the MODIS Instrument

This paper describes the results of accelerated and operational life tests on bearings for the Moderate Resolution Imaging Spectroradiometer (MODIS). It also describes the post test analysis of the disassembled bearings. Analysis was performed using micro-Raman, micro-FTIR, X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM), and Size Exclusion Chromatography (SEC). In general, the three sets of bearings in each of three test stations were in very good condition after accumulating 68, 144, and 209 million cycles, respectively. Some of the bearings exhibited lubricant degradation, indicated by viscous lubricant deposits on the cage and raceways.

VanDyk, Steven G.↗

A mission profile life test facility

A test facility is being prepared for a 16,000 hour mission profile life test of multiple electric propulsion thrust subsystems. The facility will be capable of simultaneously operating three 2.7 kW, 30 cm mercury ion thrusters and their power processing. The facility will permit conduction of a program of long-term tests to document thruster characteristics as a function of time and operating point to allow prediction of thruster performance for any mission profile. The thruster will be tested in a 7m by 10m vacuum chamber. Each thruster will be installed in a separate lock chamber so that it can be extended into, or extracted from the main chamber without violating the vacuum integrity of the other thruster. The thrusters will exhaust into a 3m by 5m frozen mercury target. The target and an array of cryopanels to collect sputtered target material will be liquid nitrogen chilled. Power processor units will be tested in an adjacent 1.5m by 2m vacuum chamber and will be temperature controlled by simulated heat pipes.

James, E.↗

Highly accelerated life testing (HALT): A review from a statistical perspective

Despite its use in one form or another for at least four decades, HALT and related techniques [e.g., highly accelerated-stress screening (HASS) and stress audits (HASA)] are not well understood within the statistical community and remain controversial. This largely reflects a conflict in motivation between engineers, testing under harsh conditions to discover and eliminate failure modes, and statisticians, taking a more cautious approach to develop quantitative estimates of parameters such as mean time between failures (MTBF). Here, this review article will clarify HALT concepts and methods and explain where it fits within the universe of methods that involve the application of accelerating factors to compress the time required to evaluate or enhance product reliability. A major distinction is between methods such as HALT, a high-stress test-analyze-fix-test iterative process directed at improving reliability by discovering and fixing weak points in a design, and quantitative accelerated life testing (QALT), whose goal is the estimation of product life for a fixed design. We discuss methods such as physics of failure that offer some hope of bridging the gap between the qualitative nature of HALT, and purely quantitative statistical methods. We present a variety of engineering applications of HALT including metal fatigue, piping and pressure vessels, structural damage, radiation damage, and rotating machinery. We also discuss potential synergies between HALT and QALT, such as rapid identification, through HALT, of failure modes requiring quantitative analysis. For further study, extensive references to the applicable literature are provided as well as an appendix that describes related methods.

97 MATHEMATICS AND COMPUTING↗

Destructive physical analysis of hollow cathodes from the Deep Space 1 Flight spare ion engine 30,000 hr life test

Destructive physical analysis of the discharge and neutralizer hollow cathode assemblies from the Deep Space 1 Flight Spare 30,000 Hr life test was performed to characterize physical and chemical evidence of operationally induced effects after 30,372 hours of operation with beam extraction. Post-test inspection of the discharge-cathode assembly was subdivided into detailed analyses at the subcomponent level. Detailed materials analysis and optical inspection of the insert, orifice plate, cathode tube, heater, keeper assembly, insulator, and low-voltage propellant isolator were performed. Energy dispersive X-ray (EDX) and scanning electron microscopy (SEW analyses were used to determine the extent and composition of regions of net deposition and erosion of both the discharge and neutralizer inserts. A comparative approach with an un-operated 4:1:1 insert was used to determine the extent of impregnate material depletion as a function of depth from the ID surface and axial position from the orifice plate. Analysis results are compared and contrasted with those obtained from similar analyses on components from shorter term tests, and provide insight regarding the prospect for successful longer-term operation consistent with SOA ion engine program life objectives at NASA.

cathodes↗

Results of the Mission Profile Life Test first test segment - Thruster J1

A series of long term test segments of 30 cm diameter mercury bombardment thrusters is being conducted as the Mission Profile Life Test. The first 4000 hour segment has been completed with the J series thruster, J1. Thruster and power processing units were controlled by computer with software algorithms governing normal functions of startup, throttle, and shutdown as well as automatically handling a variety of off-normal conditions. Thruster operation includes a discussion of the test chronology describing notable events and their significance. Post-test examination provides insight into thruster lifetime. Results are consistent with mission requirements of 15,000 hours at 2A

James, E. L.↗

Traveling-wave tube reliability estimates, life tests, and space flight experience

Infant mortality, useful life, and wearout phase of twt life are considered. The performance of existing developmental tubes, flight experience, and sequential hardware testing are evaluated. The reliability history of twt's in space applications is documented by considering: (1) the generic parts of the tube in light of the manner in which their design and operation affect the ultimate reliability of the device, (2) the flight experience of medium power tubes, and (3) the available life test data for existing space-qualified twt's in addition to those of high power devices.

Lalli, V. R.↗

A 10,000-hr life test of an engineering model resistojet

One of the major issues associated with using resistojet thrusters on Space Station Freedom is the long life required. An engineering model resistojet was life-tested to determine if it was capable of meeting that requirement. This thruster, which was designed for 10,000 hr of operation at 2552.4 F (1400 C) or less under cyclical thermal conditions, successfully operated for 10,036 hr at 1836 F (1002 C) while undergoing 141 thermal cycles.

Slutz, Rodger J.↗

Accelerated life testing and reliability of high K multilayer ceramic capacitors

The reliability of one lot of high K multilayer ceramic capacitors was evaluated using accelerated life testing. The degradation in insulation resistance was characterized as a function of voltage and temperature. The times to failure at a voltage-temperature stress conformed to a lognormal distribution with a standard deviation approximately 0.5.

Minford, W. J.↗

International Space Station Cathode Life Testing Status

To demonstrate adequate lifetime and performance capabilities of a hollow cathode for use on the International Space Station (ISS) plasma contactor system, life tests of multiple hollow cathode assemblies (HCAs) were initiated at operating conditions simulating on-orbit operation. Three HCAs are presently being tested. These HCAs are operated with a continuous 6 sccm xenon flow rate and 3 A anode current. Emission current requirements are simulated with a square waveform consisting of 50 minutes at a 2.5 A emission current and 40 minutes with no emission current. As of July 1998, these HCAs have accumulated between 1 1,700 and 14,200 hours. While there have been changes in operatin, behavior the three HCAs continue to operate stably within ISS specifications and are expected to demonstrate the required lifetime.

Sarver-Verhey, Timothy R.↗

Results of the mission profile life test

Seven J series 30-cm diameter thrusters have been tested in segments of up to 5,070 hr, for 14,541 hr in the Mission Profile Life Test facility. Test results have indicated the basic thruster design to be consistent with the lifetime goal of 15,000 hr at 2-A beam. The only areas of concern identified which appear to require additional verification testing involve contamination of mercury propellant isolators, which may be due to facility constituents, and the ability of specially covered surfaces to contain sputtered material and prevent flake formation. The ability of the SCR, series resonant inverter power processor to operate the J series thruster and autonomous computer control of the thruster/processor system were demonstrated.

Bechtel, R. T.↗