Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Atomic-Scale Imaging of Lithium Vacancies in a Battery Cathode by Multislice Electron Ptychography

Atomic-resolution imaging of battery materials is critical for identification of local defects and structural variations, which are tied to battery performance. However, since battery materials are, by design, optimized to allow ion motion in response to an applied electric field, they are also very sensitive to radiation damage by an electron beam. Image resolution is therefore severely constrained by the dose applied. Here, we show that multislice electron ptychography (MEP) can provide sub-ångström lateral resolution images of both light and heavy elements of a Li-ion battery cathode, along with nanometer-scale depth information and greater dose efficiency than conventional electron microscopy methods. Using the depth-sectioning capability of MEP, we have been able to obtain direct visualizations of Li vacancy clusters, atom column by atom column, in Li x Ni 0.33 Mn 0.33 Co 0.33 O 2 (NMC111) cathodes. This capability to track Li distributions will be valuable in understanding, informing, and optimizing electrode material design for ion storage and transfer.

batteries↗

Impact of atomic substitution on core-hole relaxation dynamics: A study of Br 2 and IBr

Understanding inner-shell decay processes in heavy-element molecules is essential for unraveling x-ray-induced photodynamics and advancing molecular imaging techniques. Here, in this study, we investigate the influence of atomic substitution on core-hole relaxation dynamics and molecular fragmentation in Br 2 and IBr, initiated by x-ray ionization absorption at the Br K-edge. Using a combination of x-ray/ion coincidence measurements and Monte Carlo/molecular dynamics simulations, we track the charge distribution and the kinetic energy release (KER) of fragment ions with a total charge from 2+ to 8+. For both molecules, the simulated KER values show good agreement with experiment across different fragmentation channels. Our comparison reveals that substituting Br with the heavier I atom in IBr has a minimal impact on the inner-shell electronic decay process but significantly influences nuclear motion, leading to slower dissociation and thus a KER close to the Coulomb limit—an effect attributed to the atomic mass. These findings highlight the interplay between electronic and nuclear effects in molecular fragmentation, particularly in heavy-element species, and provide new insights into medical therapies, structural biology, and astrophysics.

Bhat, Nivedita [Argonne National Laboratory (ANL),↗

Impact of tracking resolution on 𝜙-meson spin alignment measurements

Measurements of global spin alignment of vector mesons in relativistic heavy-ion collisions can provide unique insights into spin-orbit interactions and vector meson dynamics in the quark-gluon plasma produced in those collisions. The global spin alignment is measured by the 00th coefficient of the spin density matrix, 𝜌 00 , via the polar angle (𝜃*) of the decay-kaon momentum in the parent rest frame with respect to the direction of the orbital angular momentum of the collision. Such measurements are affected by the angular and momentum resolutions of the reconstructed tracks in the experiment. Such effects are nontrivial because of kinematic complications caused by the boost to the parent rest frame, and could be important given that the global spin alignment signal is weak. In this paper, we investigate the effects of experimental tracking resolutions on measurements of the 𝜙 (1020) meson 𝜌 00 . We study these effects for two methods of 𝜌 00 measurements, the conventional method analyzing the 𝜙⁢−meson yield versus cos 2 ⁡𝜃* and the invariant mass (𝑚 inv ) method utilizing ⟨cos 2 ⁡𝜃*⟩ versus 𝑚 inv . Using typical resolution values from experiments, we find that the effect of track resolution on 𝜌 00 is small, well within typical measurement uncertainties.

Relativistic heavy-ion collisions↗

Correlation between antiferromagnetic and Mott states in spin orbit coupled Sr 2 Ir O 4 : A study of Sr 2 Ir 1 – x M x O 4 ( M = Fe or Co)

Sr 2 IrO 4 is an archetypal spin-orbit-coupled Mott insulator with an antiferromagnetic state below 240 K. Here we report results of our study on single crystals of Sr 2 Ir 1–x Fe x O 4 (0 ≤ x < 0.32) and Sr 2 Ir 1–x Co x O 4 (0 ≤ x < 0.22). Fe doping retains the antiferromagnetic state but simultaneously precipitates an emergent metallic state whereas Co doping causes a rapid collapse of both the antiferromagnetic and Mott states, giving rise to a confined metallic state featuring a pronounced linearity of the basal-plane resistivity up to 700 K. The results indicate tetravalent Fe 4+ (3d 4 ) ions in the intermediate spin state with S = 1 and Co 4+ (3d 5 ) ions in the high spin state with S = 5/2 substituting for Ir 4+ (5d 5 ) ions in Sr 2 IrO 4 , respectively. The effective magnetic moment closely tracks the Néel temperature as doping increases, suggesting that the spin state of the dopant predominately determines the magnetic properties in doped Sr 2 IrO 4 . Furthermore, all relevant properties including charge-carrier density (e.g., 10 28 /m 3 ), Sommerfeld coefficient (e.g., 19 mJ / mole K 2 ), and Wilson ratio (e.g., 2.6) consistently demonstrate an emergent metallic state that is both robust and highly correlated in the two systems, arising from the percolation of bound states and the weakening of structural distortions. Furthermore, this study strongly indicates that the antiferromagnetic and Mott states are correlated in an unconventional manner in Sr 2 IrO 4 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fast 2D Bicephalous Convolutional Autoencoder for Compressing 3D Time Projection Chamber Data

High-energy large-scale particle colliders produce data at high speed in the order of 1 terabytes per second in nuclear physics and petabytes per second in high energy physics. Developing real-time data compression algorithms to reduce such data at high throughput to fit permanent storage has drawn increasing attention. Specifically, at the newly constructed sPHENIX experiment at the Relativistic Heavy Ion Collider (RHIC), a time projection chamber is used as the main tracking detector, which records particle trajectories in a volume of three-dimensional (3D) cylinder. The resulting data are usually very sparse with occupancy around 10.8%. Such sparsity presents a challenge to conventional learning-free lossy compression algorithms, such as SZ, ZFP, and MGARD. The 3D convolutional neural network (CNN)-based approach, Bicephalous Convolutional Autoencoder (BCAE), outperforms traditional methods both in compression rate and reconstruction accuracy. BCAE can also utilize the computation power of graphical processing units suitable for deployment in a modern heterogeneous highperformance computing environment. This work introduces two BCAE variants: BCAE++ and BCAE-2D. BCAE++ achieves a 15% better compression ratio and a 77% better reconstruction accuracy measured in mean absolute error compared with BCAE. BCAE-2D treats the radial direction as the channel dimension of an image, resulting in a 3× speedup in compression throughput. In addition, we demonstrate an unbalanced autoencoder with a larger decoder can improve reconstruction accuracy without significantly sacrificing throughput. Lastly, we observe both the BCAE++ and BCAE-2D can benefit more from using half-precision mode in throughput (76 - 79% increase) without loss in reconstruction accuracy. The source code and links to data and pretrained models can be found at https://github.com/BNL-DAQ-LDRD/NeuralCompression_v2

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Survey of AC-LGADs for future 4D trackers with a proton beam

We will present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility, and a study of the performance of AC-LGAD sensors as a function of their thickness. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. Long strip sensors with sparse readout offer better cost and performance for applications where channel count or electrical power density is a constraint. Thanks to the excellent signal to noise ratio in AC-LGADs, sparse readout can be exploited without significant degradation of spatial or time resolution, which is demonstrated in our studies. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. We will present our studies of the sensor geometry optimizatio n to maintain the desirable sensor performance characteristics with increasingly larger electrodes.

43 PARTICLE ACCELERATORS↗

First survey of centimeter-scale AC-LGAD strip sensors with a 120 GeV proton beam

We will present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility, and a study of the performance of AC-LGAD sensors as a function of their thickness. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. Long strip sensors with sparse readout offer better cost and performance for applications where channel count or electrical power density is a constraint. Thanks to the excellent signal to noise ratio in AC-LGADs, sparse readout can be exploited without significant degradation of spatial or time resolution, which is demonstrated in our studies. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. We will present our studies of the sensor geometry optimization to maintain the desirable sensor performance characteristics with increasingly larger electrodes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First survey of centimeter-scale AC-LGAD strip sensors with a 120 GeV proton beam

We present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility and sensors manufactured by the Brookhaven National Laboratory. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. Several design considerations are discussed towards maintaining desirable signal characteristics with increasingly larger electrodes. The resolutions obtained with several prototypes are presented, reaching simultaneous 18 micron and 32 ps resolutions from strips of 1 cm length and 500 micron pitch. With only slight modifications, these sensors would be ideal candidates for a 4D timing layer at the EIC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamics of Electric Polarization and Relaxation of Ions at Humid Calcite Surfaces

Mobile ions at mineral surfaces can respond to an applied electric field, adopting a new distribution that effectively represents polarization of the electrical double layer. When the field is released, the ions relax to their equilibrium distribution. In both cases, the dynamics are characteristic of the interface. However, current models of electrokinetic phenomena are not sufficiently robust to accurately predict collective ion dynamics at structurally and chemically specific mineral–water interfaces. Here, in this study, we use electrostatic force microscopy (EFM) to investigate the dynamics of ion relaxation at hydrated calcite (104) surfaces at controlled relative humidity (RH). Electrically biased probes are used to polarize the distributions of calcium and carbonate ions that are intrinsic to this interface across a range of RH values. Polarization kinetics are tracked by monitoring the tip–sample force gradient during charging, and EFM imaging is used to characterize the spatial relaxation dynamics after the applied field is released. Electrostatic finite element modeling of the sample/probe system across length-scales from nanometers to millimeters reproduces the observed stretched exponential charging response. Together, these results allow us to estimate the ion diffusivities at the interface across a wide range of RH values. These diffusivities increase by roughly 5 orders of magnitude as the RH is increased from 5 to 90%, highlighting the critical role of adsorbed water for surface ion solvation that enables ion mobility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Decoding ionic conductivity and reordering in cation-disordered pyrochlores

The ordered structure A 2 B 2 O 6 O’ in pyrochlores engenders twin rows of inequivalent anion sublattices each centred on alternating cations. While it is known that cation antisite disorder augments the ionic conductivity by several orders of magnitude, the local cation environment around the anions and the dynamic anion reordering during the cation disordering are not well-elucidated. Using atomistic simulations on Gd 2 Zr 2 O 7 , we first show that the anions engage in concerted hops to the neighbouring tetrahedral sites mostly along with the $\langle$1 0 0$\rangle$ direction while completely avoiding the octahedral sites. While the initially vacant 8 a sites start accommodating oxygen ions with increasing cation disorder, they show noticeable reluctance even at significant levels of disorder. We have also tracked both the distribution of available oxygen sites following random cation disorder, which is dependent only on cation disordering, and the probability of occupation of these sites. Interestingly, the available oxygen sites show a non-monotonic dependence on the number of B ions in the nearest neighbouring shell while the occupation probability of all the available oxygen sites increases monotonically. A tetrahedral oxygen site thus has a better probability of being occupied when it has a greater number of second neighbour B ions. This article is part of the Theo Murphy meeting issue 'Understanding fast-ion conduction in solid electrolytes'.

Science & Technology - Other Topics↗

Analysis of the electrical double layer using electrochemical X-ray photoelectron spectroscopy

The element-sensitivity of X-ray spectroscopies offers the potential to disentangle the individual chemistries of water, ions, and adsorbates at the electrode-electrolyte interface in an element-by-element manner. However, targeted experimental design is needed to establish interface-sensitive in situ X-ray spectroscopy in a realistic electrochemical environment. Here, we demonstrate how electrochemical X-ray photoelectron spectroscopy (EC-XPS) in the dip-and-pull geometry can be used to specifically probe the behavior of ions in the electrical double layer. Taking the case study of a polycrystalline Au foil in 50 mM KClO 4 electrolyte, we tracked the electrochemical response of interfacial K + cations across a broad potential range. We show how, in combination with modeling, key parameters such as the potential of zero charge (PZC), ion packing behavior, dielectric saturation, and the electrostatic potential decay in the double layer can be extracted from the data. Importantly, we also analyze how the experimental conditions and non-idealities can influence the results and put forward criteria for reliable experimentation and data analysis.

Dip-and-pull↗

Toward Long-Term Accurate and Continuous Monitoring of Nitrate in Wastewater Using Poly(tetrafluoroethylene) (PTFE)–Solid-State Ion-Selective Electrodes (S-ISEs)

Long-term accurate and continuous monitoring of nitrate (NO 3 – ) concentration in wastewater and groundwater is critical for determining treatment efficiency and tracking contaminant transport. Current nitrate monitoring technologies, including colorimetric, chromatographic, biometric, and electrochemical sensors, are not feasible for continuous monitoring. In this work, we addressed this challenge by modifying NO 3 – solid-state ion-selective electrodes (S-ISEs) with poly(tetrafluoroethylene) (PTFE, (C 2 F 4 ) n ). The PTFE-loaded S-ISE membrane polymer matrix reduces water layer formation between the membrane and electrode/solid contact, while paradoxically, the even more hydrophobic PTFE-loaded S-ISE membrane prevents bacterial attachment despite the opposite approach of hydrophilic modifications in other antifouling sensor designs. Specifically, an optimal ratio of 5% PTFE in the S-ISE polymer matrix was determined by a series of characterization tests in real wastewater. Five percent of PTFE alleviated biofouling to the sensor surface by enhancing the negative charge (–4.5 to –45.8 mV) and lowering surface roughness (Ra: 0.56 ± 0.02 nm). It simultaneously mitigated water layer formation between the membrane and electrode by increasing hydrophobicity (contact angle: 104°) and membrane adhesion and thus minimized the reading (mV) drift in the baseline sensitivity (“data drifting”). Long-term accuracy and durability of 5% PTFE-loaded NO 3 – S-ISEs were well demonstrated in real wastewater over 20 days, an improvement over commercial sensor longevity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The forward TPC system of the NA61/SHINE experiment at CERN: a tandem TPC concept

This paper presents the Forward Time Projection Chamber (FTPC) system of the NA61/SHINE experiment at the CERN SPS accelerator. This TPC system applies a novel tandem-TPC design to reduce the background originating from particle tracks not synchronous with the event trigger. The FTPC system is composed of three chambers with alternating drift field directions. The chambers were installed directly along the beamline region of the NA61/SHINE detector in a medium- to high-intensity (10-100 kHz) hadron or ion beam. The tandem TPC system has proved to be capable of rejecting out-of-time background tracks not associated with a primary interaction. In addition, the system performs tracking and inclusive dE/dx particle identification for particles at and near the beam momentum. This shows that a tandem-TPC-based chamber design may be used also in other experimental applications with a demand for low material budget, tracking capability, and the need for dE/dx particle identification, all while in the presence of a relatively high particle flux.

47 OTHER INSTRUMENTATION↗

Recent Studies on Void Shrinkage in Metallic Materials Subjected to In Situ Heavy Ion Irradiations

The continuous formation and growth of voids induced by radiations in metallic materials may lead to significant microstructure damage and degradation of mechanical properties. In sharp contrast to the void swelling commonly observed in irradiated metallic materials, nanovoids in nanoporous metallic materials are found to shrink during radiation and thus nanovoids enhance the radiation tolerance of metallic materials. This article reviews recent studies on size-dependent void shrinkage in metallic materials subject to in situ heavy ion irradiation. Furthermore, we demonstrate the capability of machine learning in identifying and tracking the evolution of nanovoids. Finally, the physical mechanisms of radiation induced void shrinkage revealed by simulation studies are briefly summarized.

36 MATERIALS SCIENCE↗

Near-infrared noise in intense electron bunches

This article investigates electron bunch density fluctuations in the 1 −10 μ⁢m wavelength range, focusing on their impact on coherent electron cooling (CEC) in hadron storage rings. In this study, we compare the shot-noise model with experimental observations using bandwidth-filtered near-infrared optical transition radiation (OTR) photodiode signals, where the transverse bunch size is much larger than the OTR wavelength of interest. The relativistic electron bunch (𝛾 ≈ 50) parameters are close to those proposed for the coherent electron cooler in the electron-ion collider (EIC) project. Preliminary feasibility experiments were conducted, and the noise factors are presented, supported by particle tracking. No major density fluctuations or effective cooling rate decrease were revealed for EIC CEC design parameters. Additionally, longitudinal-space-charge-induced microbunching for the chicane-compressed bunch was observed with coherent OTR enhancements up to 100 times, providing further calibration of the measurement method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Particle Tracking Methods for Battery Precipitation Reactions

Precipitation and deposition reactions at solid–liquid interfaces play a key role in a number of battery chemistries, including Li-ion, so-called “anode free” batteries, zinc-based battery chemistries, and lithium–sulfur, among others. Although models with heterogeneous nucleation and growth phenomena are present in the literature, papers have not to date provided much detail on the numerical algorithms used to track the temporal evolution of the particle size distribution of deposits on electrode surfaces. In this paper we examine several approaches to discretize and track the particle size distribution, demonstrating that common approaches lead to anomalous flattening of the particle size distribution. We conclude by presenting an algorithm that preserves the appropriate particle size distribution during particle growth.

Algorithms↗

Improving the Operational Lifetime of the CEBAF Photo-Gun by Anode Biasing

The operating lifetime of GaAs-based photocathodes in DC high voltage electron photo-guns is dominated by the ionization rate of residual beamline gas molecules. In this work, experiments were performed to quantify the improvement in photocathode charge lifetime by biasing the photo-gun anode with a positive voltage, which repels ions generated downstream of the anode. The photo-cathode charge lifetime improved by almost a factor of two when the anode was biased compared to the usual grounded configuration. Simulations were performed using the particle tracking code General Particle Tracer (GPT) with a new custom element. The simulation results showed that both the number and energy of ions play a role in the pattern of QE degradation. The experiment results and conclusions supported by GPT simulations will be presented.

Yoskowitz, J. T.↗

Visualizing electrode assembly movement and lithiation heterogeneity in lithium-metal batteries using operando energy dispersive X-ray diffraction

There is renewed interest in Li-metal anodes in order to increase the energy density of battery cells. Here, we demonstrate an operando X-ray crystallography method to visualize lithiation gradients and electrode assembly movement during electrochemical cycling of a Li-metal cell containing a Ni-Mn-Co layered oxide cathode (NMC811). During charge, deposition of Li + ions from the cathode increases the Li foil thickness; during discharge, the thickness decreases as Li + ions are stripped off the foil. Additionally, the resulting periodic movement is observed through tracking of Bragg peaks from the ordered phases of the cathode and separator. In addition to this 3.6 μm/mAh displacement, continuous mossy Li build-up on the anode causes an irreversible drift of the assembly, which is similar to 11.3 μm/cycle. Furthermore, our data indicate significant lithiation gradients in the NMC811 cathode during the oxide relithiation, which is not observed during the delithiation.

25 ENERGY STORAGE↗