Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Picosecond laser generated plasma as a source of singly charged ions for external injection into an EBIS

The focus of this paper is on practical aspects of ion generation by picosecond lasers as a source of low charge state ions for external injection of ions into an electron beam ion source (EBIS). For a ps-laser, compared to a ns-laser currently used at Relativistic Heavy Ion Collier Electron Beam Ion Source (RHIC EBIS), the influence of heat conductivity in the solid target is almost negligible, which results in a lower target consumption rate and less vacuum pressure rise. By using a laser with high repetition rate, it is possible to produce quasi continuous 1+ ion beams for periods of tens of milliseconds, making it possible to take advantage of the ability of the EBIS to accumulate ions in the “slow” injection capture mode. Producing such an ion pulse train is now feasible since ps-lasers with pulse energy up to 10 mJ and rep-rate up to 10 kHz have recently become commercially available. The advantages of this lower current accumulation scheme include: (1) easier beam transport due to lower space charge of lower beam currents required compared to the present single pulse fast injection scheme, (2) better EBIS pulse to pulse ion output stability since pulse to pulse ion variations of the laser source are averaged over a long train of laser pulses, and (3) the possible addition of an isotope separator in which rare beams could be produced and selected at run time from less expensive (unenriched) targets. We studied the properties of plasmas generated by a ps-laser with 1.27 mJ energy within an 8 ps pulse and a repetition rate up to 400 Hz at Argonne National Laboratory to investigate feasibility and specify parameters for a laser ion source for RHIC EBIS using a “slow” injection mode. Al, Ti, Cu, Nb, and Ta targets were tested with various target translation speeds. Here, we demonstrated that a both “slow” and “fast” injection modes are accessible with a single ion source geometry and single injection line, providing the most attractive option for an ion source for external injection into RHIC EBIS trap based on a ps-laser.

43 PARTICLE ACCELERATORS↗

Characterization and automated optimization of laser-driven proton beams from converging liquid sheet jet targets

Compact, stable, and versatile laser-driven ion sources hold great promise for applications ranging from medicine to materials science and fundamental physics. While single-shot sources have demonstrated favorable beam properties, including the peak fluxes necessary for several applications, high-repetition-rate operation will be necessary to generate and sustain the high average flux needed for many of the most exciting applications of laser-driven ion sources. Further, to navigate through the high-dimensional space of laser and target parameters toward experimental optima, it is essential to develop ion acceleration platforms compatible with machine learning techniques and capable of autonomous real-time optimization. Here, we present a multi-Hz ion acceleration platform employing a liquid sheet jet target. We characterize the laser-plasma interaction and the laser-driven proton beam across a variety of key parameters governing the interaction using an extensive suite of online diagnostics. We also demonstrate real-time, closed-loop optimization of the ion beam maximum energy by tuning the laser wave front using a Bayesian optimization scheme. This approach increased the maximum proton energy by 11% compared to a manually optimized wave front by enhancing the energy concentration within the laser focal spot, demonstrating the potential for closed-loop optimization schemes to tune future ion accelerators for robust high-repetition-rate operation.

Glenn, G. D. [SLAC National Accelerator Laboratory↗

Sputter sample preparation for ion beam delivery of radium-223 at ATLAS

A radium-223 ion beam was delivered to an experiment from the electron cyclotron resonance ion source, ECR2, at the Argonne Tandem Linac Accelerator System (ATLAS). Here, the radium-223 material was in a nitrate salt form within a vial, prior to being converted to a usable sputter sample. The sputter sample was produced using a new sample preparation method, where the radium nitrate was dissolved into a solution and pipetted onto pressed aluminum powder. This sample was then allowed to dry, distributing the radium-223 material throughout the sputter sample. Ion source operation using the radium sputter sample is described with the operating parameters listed. The intensity and energy requirements for this ion beam were 1 × 10 6 particles/s and 1.07 GeV, respectively. Because the intensity is relatively low compared to most experiments at ATLAS, previously developed accelerator mass spectrometry methods were used Scott et al. to avoid the need for tuning of the low-intensity beam of interest. Handling of the radium material, as well as loading and unloading of the sputter sample from ECR2, required collaboration with Health Physics. Procedures were used and dry runs were carried out before, during, and after the experiment to ensure the safety of the workers. The processes used and lessons learned are described within.

07 ISOTOPE AND RADIATION SOURCES↗

Experiments with a prototype titanium hot cavity surface ionization source intended for electromagnetic separation of radioactive samarium and other lanthanide elements

This paper reports experimental results of a prototype titanium surface ionization source. For the first time, a lanthanide ion beam has been produced with a surface ionizer composed completely of titanium metal. Titanium does not readily activate with neutron irradiation. This offers the potential for inserting an ion source made of titanium directly into a reactor with a pre-loaded non-radioactive lanthanide target. This seamlessly integrates target irradiation with isotope separation, eliminating post irradiation sample manipulation. Samarium ion beam currents up to 960 nA have been produced in an off-line test bench equipped with rudimentary beam optics. This is a crucial step toward the development of an ionization source adopted for the electromagnetic isotope separator (EMIS) facility, which has been designed for high throughput separations of radioactive 153 Sm and other lanthanides of interest in the field of nuclear medicine. The ion current and important factors affecting the performance of the ion source, such as the ionizer temperature and thermal gradient, are discussed. Lastly, the experimental results are presented together with a discussion of future modifications to optimize the overall surface ionization source performance.

07 ISOTOPE AND RADIATION SOURCES↗

In situ Detection of Plasma Induced Surface Interaction based on Deep Learning based Visual Diagnostics (Technical Report)

It is characteristic for many plasma devices to undergo plasma-material interaction leading to surface erosion. These processes, often not easily detectable, lead to changes in device performance and lifespan. State-of-the-art lifetime tests and wear experiments require over 1000s hours. A self-consistent model for accurately predicting the erosion's effects is not available. In situ detection of these processes is not a trivial task since the surface variations at the early stages have a micron scale. Such limitations not only restrict testing and prediction capabilities but also slow the development of new thrusters and limit mission duration. To address these challenges, an in-situ diagnostic for real-time erosion assessment has been developed, aiming to expedite lifetime testing and broaden experimental campaigns. Several works were dedicated to real-time and in situ monitoring of material erosion during plasma exposure using laser holography, microscopy, and with telemicroscopes. However, the applicability of these approaches is limited due to complexity, cost and less flexibility as they often require placing diagnostic equipment inside the vacuum chamber. In collaboration with Princeton Collaborative Research Facility (PCRF), Princeton Plasma Physics Laboratory (PPPL), a new diagnostic approach is developed, where geometry modifications to the ceramic channel walls were introduced that would result in accelerated channel erosion. We employed Long-distance microscope (LDM) imagery, combined with Deep-Learning based Shape from focus or depth from focus (DFF or SFF) approach, that provides an accessible and cost-effective solution. LDM employs focus variation techniques to continuously capture multiple images of the target object at distinct focal planes. DFF, an optical focus variation method, generates a 3D topographical surface depth map from a sequence of variably focused images. Combined with the developed diagnostic, this approach offers a controllable means to study erosion under accelerated conditions. In this work, we develop Neural Network-based DFF algorithm applicable for LDM data to quantitatively evaluate plasma induced surface modification from LDM data. Next, we develop Deep Learning-based super-resolution depth map image reconstruction technique to increase the resolution of depth maps obtained from DFF algorithm to improve the accuracy of erosion measurements. Thirdly, we develop several image processing techniques to remove noise and improve the quality of depth map image. Here we report the results of initial tests for this approach. An experimental setup designed and built in PPPL was employed that consists of a 3-cm gridded ion source that produces a neutralized argon beam with energies up to 600 eV. A hexagonal boron nitride (h-BN) ceramic target, designed based on computational predictions, was used. Tests were conducted to reconstruct the complex geometry of the target under the lighting conditions of the operated ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-energy H- beam injectors for particle accelerators: upgrade requirements, challenges and future plans [Slides]

High brightness, negative hydrogen ion sources are used extensively in large, accelerator-based, user facilities operating worldwide. Negative hydrogen beams have become the preferred means of filling circular accelerators and storage rings as well as enabling efficient extraction from cyclotrons. Much larger beams of H- ions are also utilized for neutral beams injection into fusion machines and will be discussed in a separate companion presentation. Some of the accelerator facilities include the US Spallation Neutron Source (SNS), Japan Proton Accelerator Research Complex (J-PARC), Rutherford Appleton Laboratory (RAL-ISIS), Los Alamos Neutron Science Center (LANSCE), Fermi National Accelerator Laboratory (FNAL), Brookhaven National Laboratory (BNL), the CERN LHC injector, the Chinese Spallation Neutron Source (CSNS) as well as numerous installations of D-Pace (licenced by TRIUMF) ion sources used mainly with cyclotrons. Many facilities are currently working on various improvement / upgrade projects, both in the near and long term, which are driving further development of their ion source and LEBT (Low Energy Beam Transport) and, in some cases, their overall front end injector system. This report will first provide a simple description of each facilities existing ion source and LEBT and summarize the operational parameters which are currently being routinely injected into their accelerators. Next, the parametric goals of each of the facilities upgrade projects are specified as well as development efforts currently underway to meet these requirement and improvement goals. It is hoped that that this work will not only capture the current state-of-the-art of worldwide H- beam injectors and clarify the research goals and efforts of the community in general but will also encourage further inter laboratory collaborations.

43 PARTICLE ACCELERATORS↗

Laser power density dependence on charge state distribution of Ta ion laser plasma

Laser power density per pulse, which is commonly expressed with the unit of “W/cm2,” is an important parameter to characterize ablation plasma. To match a design charge state of heavy ion beam induced by a laser ion source, a laser power density must be carefully chosen. Above around 108 W/cm2 of laser power density, laser ablation plasma is emitted from the surface of solid material. Then, up to 109 W/cm2, the most abundant charge state is 1+. Because the ionization energy increases with higher charge states, increasing the laser intensity leads to the charge state distribution shifting higher. Increasing the density to increase charge states also results in lower time of flight due to higher velocities. The maximum laser power density is obtained by the smallest available laser spot size on the target material which is determined by the quality of the laser beam. For many accelerator applications, higher charge state beams are preferred. In particular cases, singly charge ion beams are demanded. Therefore, production of intermediate charge state beams has not been investigated well. In this study, we selected Ta4+ as an example demanded beam and tried to clarify how the transition of charge state distribution depends on laser power density. Conclusively, the possible specification of a laser ion source for Ta4+ delivery was elucidated.

Okamura, Masahiro (ORCID:0000000255521706)↗

The role of plasma–atom and molecule interactions on power & particle balance during detachment on the MAST Upgrade Super-X divertor

This paper shows first quantitative analysis of the detachment processes in the MAST Upgrade Super-X divertor (SXD). We identify an unprecedented impact of plasma-molecular interactions involving molecular ions (likely $D^+_2$), resulting in strong ion sinks (Molecular Activated Recombination—MAR), leading to a reduction of ion target flux. The MAR ion sinks exceed the divertor ion sources before electron-ion recombination (EIR) starts to occur, suggesting that significant ionisation occurs outside of the divertor chamber. In the EIR region, $T_e \ll 0.2$ eV is observed and MAR remains significant in these deep detached phases. The total ion sink strength demonstrates the capability for particle (ion) exhaust in the Super-X Configuration. Molecular Activated Dissociation is the dominant volumetric neutral atom creation process can lead to an electron cooling of 20% of $P_\mathrm{SOL}$. The measured total radiative power losses in the divertor chamber are consistent with inferred hydrogenic radiative power losses. This suggests that intrinsic divertor impurity radiation, despite the carbon walls, is minor in the divertor chamber. This contrasts previous TCV results, which may be associated with enhanced plasma-neutral interactions and reduced chemical erosion in the detached, tightly baffled SXD. The above observations have also been observed in higher heat flux (narrower SOL width) type I ELMy H-mode discharges. This provides evidence that the characterisation in this paper may be general.

plasma-molecular interactions↗

Characterizing the plasma-induced thermal loads on a 200 kW light-ion helicon plasma source via infra-red thermography

The light-ion helicon plasma source of the Proto-MPEX linear plasma device has been recently upgraded to enable pulsed (0.5–1 s) operation up to 200 kW. The main objective of this work is to report on the plasma-induced surface heat fluxes incident on the helicon window during high power operation (60–150 kW net power) for the purpose of the design of the upcoming material plasma exposure eXperiment (MPEX). The IR imaging system and associated physics models for the extraction of surface heat fluxes are presented. Furthermore, experimental results demonstrate that the control of the plasma strike point via magnetic flux mapping and the use of dedicated limiters is effective at reducing the heat loads on the dielectric window. Moreover, it is found that the flux mapping must create a gap between the plasma and the dielectric window of at least the plasma radial decay length. Extrapolated to 200 kW net RF power, this mode of operation can reduce the power lost to the dielectric window by 33%. The results presented have direct application to the design of high-powered helicon plasma sources that operate in a steady state. Examples include linear divertor simulators such as MPEX, electric thrusters, negative ion sources for NBI and linear plasma–material interaction test stands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron generation using pyroelectric crystals

According to one embodiment, a method for producing a directed neutron beam includes producing a voltage of negative polarity of at least −100 keV on a surface of a deuterated or tritiated target in response to a temperature change of a pyroelectric crystal of less than about 40° C., the pyroelectric crystal having the deuterated or tritiated target coupled thereto, pulsing a deuterium ion source to produce a deuterium ion beam, accelerating the deuterium ion beam to the deuterated or tritiated target to produce a neutron beam, and directing the ion beam onto the deuterated or tritiated target to make neutrons using at least one of a voltage of the pyroelectric crystal, and a high gradient insulator (HGI) surrounding the pyroelectric crystal. The directionality of the neutron beam is controlled by changing the accelerating voltage of the system. Other methods are presented as well.

Tang, Vincent↗

Ion beam profiling system and related methods

An ion beam profiling system include a beam profiling element, an ion sensitive element electrically isolated from the beam profiling element, an ion source configured to emit an ion beam at the beam profiling element and the ion sensitive element, and a current measuring device coupled to the ion sensitive element. The beam profiling element includes a plate of material having two parallel major surfaces, a first slit aperture extending through the plate of material and having a first longitudinal length extending in a direction parallel to the two parallel major surfaces, and a second slit aperture extending through the plate of material and having a second longitudinal length extending in a direction parallel to the two parallel major surfaces, wherein the first longitudinal length of the first slit aperture is perpendicular to the second longitudinal length of the second slit aperture.

Taylor, Chase N.↗

Neutron generation using pyroelectric crystals

A method for producing a neutrons includes producing a voltage of negative polarity of at least −100 keV on a surface of a deuterated or tritiated target in response to a temperature change of a pyroelectric crystal of less than about 40° C., the pyroelectric crystal having the deuterated or tritiated target coupled thereto, pulsing a deuterium ion source to produce a deuterium ion beam, accelerating the deuterium ion beam to the deuterated or tritiated target, and directing the ion beam onto the deuterated or tritiated target to make neutrons using at least one element of the following: a voltage of the pyroelectric crystal and a high gradient insulator (HGI) surrounding the pyroelectric crystal. The accelerating of the deuterium ion beam is achieved by using an ion accelerating mechanism comprising a pyroelectric stack accelerator having a first thermal altering mechanism for changing a temperature of the pyroelectric stack accelerator.

Tang, Vincent↗

The NanoSIMS-HR: The Next Generation of High Spatial Resolution Dynamic SIMS

The high lateral resolution and sensitivity of the NanoSIMS 50 and 50L series of dynamic SIMS instruments have enabled numerous scientific advances over the past 25 years. Here, in this study, we report on the NanoSIMS-HR, the first major upgrade to the series, and analytical tests in a suite of sample types, including an aluminum sample containing silicon crystals, microalgae, and plant roots colonized with a symbiotic fungus. Significant improvements have been made in the Cs + ion source, high voltage (HV) control, stage reproducibility, and other aspects of the instrument that affect performance. The modified design of the NanoSIMS-HR thermal-ionization Cs + source enables a 5 pA primary ion beam to be focused into a 100 nm spot, a ~2.5-fold increase compared to Cs + sources on previous instruments (~2 pA at 100 nm). The brightness of the new Cs + source enables an ultimate lateral resolution as high as 30 nm and improved detection limits for a given analysis area. Sample stage movement accuracy is higher than 500 nm, enabling many-fold higher throughput automated analyses. With the new HV control, the primary ion beam impact energy can be reduced from 16 to 2 keV, which enables higher depth resolution during depth profiling (a 2-fold improvement), albeit with a 5-fold decrease in lateral resolution. In the NanoSIMS-HR, the secondary ion column and detection system are identical to those used in the previous series, and the isotopic analysis performance is as precise as in previous NanoSIMS instruments.

54 ENVIRONMENTAL SCIENCES↗

NanoSIP: NanoSIMS Applications for Microbial Biology

High-resolution imaging with secondary ion mass spectrometry (nanoSIMS) has become a standard method in systems biology and environmental biogeochemistry and is broadly used to decipher ecophysiological traits of environmental microorganisms, metabolic processes in plant and animal tissues, and cross-kingdom symbioses. When combined with stable isotope-labeling—an approach we refer to as nanoSIP—nanoSIMS imaging offers a distinctive means to quantify net assimilation rates and stoichiometry of individual cell-sized particles in both low- and high-complexity environments. While the majority of nanoSIP studies in environmental and microbial biology have focused on nitrogen and carbon metabolism (using 15 N and 13 C tracers), multiple advances have pushed the capabilities of this approach in the past decade. The development of a high-brightness oxygen ion source has enabled high-resolution metal analyses that are easier to perform, allowing quantification of metal distribution in cells and environmental particles. New preparation methods, tools for automated data extraction from large data sets, and analytical approaches that push the limits of sensitivity and spatial resolution have allowed for more robust characterization of populations ranging from marine archaea to fungi and viruses. Further, NanoSIMS studies continue to be enhanced by correlation with orthogonal imaging and ‘omics approaches; when linked to molecular visualization methods, such as in situ hybridization and antibody labeling, these techniques enable in situ function to be linked to microbial identity and gene expression. Here we present an updated description of the primary materials, methods, and calculations used for nanoSIP, with an emphasis on recent advances in nanoSIMS applications, key methodological steps, and potential pitfalls.

07 ISOTOPE AND RADIATION SOURCES↗

Counter-propagating toroidal Alfvén eigenmodes in tokamaks

Mechanisms of destabilization of toroidal Alfvén eigenmodes (TAEs) in tokamaks are analyzed with the aim to reveal those leading to modes propagating in the direction opposite to plasma current, i.e. counter-propagating modes (ctr-TAE). Plasmas with fast-ions sources [such as neutral beam injection (NBI), ion cyclotron resonance heating, fusion reactions] and without them (Ohmic discharges) are considered. A particular NSTX-U experiment with NBI, where co- and counter-propagating TAEs were observed simultaneously (Podestà et al 2018 Nucl. Fusion 58 082023), is considered. It is concluded that both types of TAEs occurred because their destabilization was caused by the velocity anisotropy of beam ions, which overrode effects of spatial inhomogeneity of these ions.

Alfvénic instabilities↗

Signal-to-background estimates for the inverse-kinematics 78 Kr(n,γ) experiment at LANSCE

The idea of a neutron target enables the measurement of neutron-induced reactions in inverse kinematics. This idea is part of the LANSCE strategy to stay a worldwide leader for neutron-induced research. The proof-of-principle experiment outlined in is the core of the LDRD project 20240004DR. The current approach is to use an ion source capable of accelerating single-charged ions up to about 60 keV. A beam of 78 Kr + ions will be created to interact with a neutron target and implanted. During the passage of the target, neutrons can be captured and the freshly produced 79 Kr + ions will be implanted along with the main beam.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance Optimization of the IOTA Duoplasmatron Proton Source

We present results from online optimization studies of a duoplasmatron ion source designed to produce 50~keV protons for acceleration to 2.5~MeV and subsequent injection into the Integrable Optics Test Accelerator (IOTA) at Fermilab. Using a Bayesian exploration technique, we developed multi-parameter models of the source s proton current and employed these models to optimize its performance. Depending on the spectrometer configuration used to isolate the proton beam and the chosen optimization objective, we identified three candidate operating points, achieving normalized 50~\% emittances between 0.57 and 1.3~\textmu m and a maximum proton current of $14.5 \pm 0.6$~mA.

Banerjee, Nilanjan [Fermilab] (ORCID:0000000344660↗

Off-line commissioning of the St. Benedict radiofrequency quadrupole cooler-buncher

The St. Benedict ion trapping system, which aims to measure the β - v angular correlation parameter in superallowed-mixed mirror transitions, is under construction at the University of Notre Dame. These measurements will provide much-needed data to improve the accuracy of the V ud element of the CKM matrix. One of the major components of this system is the radio frequency quadrupole cooler-buncher, which is necessary to create low-emittance ion bunches for injection into the measurement Paul trap. The off-line commissioning of the cooler-buncher, using a potassium ion source, determined that the device could produce cooled ion bunches characterized by a 50-ns full-width-half-maximum time width at its exit. The commissioning results also determined the trapping efficiency to be 93(1)% and the trapping half-life to be 20.0(5) s.

Paul trap↗