Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion mobility spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Structural Changes in Metal Chalcogenide Nanoclusters Associated with Single Heteroatom Incorporation

Atomically precise nanoclusters (NCs) are promising building blocks for designing materials and interfaces with unique properties. By incorporating heteroatoms into the core, the electronic and magnetic properties of NCs can be precisely tuned. To accurately predict these properties, density functional theory (DFT) is often employed, making the rigorous benchmarking of DFT results particularly important. In this study, we present a benchmarking approach based on metal chalcogenide NCs as a model system. We synthesized a series of bimetallic, iron-cobalt chalcogenide NCs [Co 6-x Fe x S 8 (PEt 3 ) 6 ] + (x = 0-6) (PEt = triethyl phosphine) and investigated the effect of heteroatoms in the octahedral metal chalcogenide core on their size and electronic properties. Using ion mobility-mass spectrometry (IM-MS), we observed a gradual increase in the collision cross section (CCS) with an increase in the number of Fe atoms in the core. DFT calculations combined with trajectory method CCS simulations successfully reproduced this trend, revealing that the increase in cluster size is primarily due to changes in metal-ligand bond lengths, while the electronic properties of the core remain largely unchanged. Moreover, this method allowed us to exclude certain multiplicity states of the NCs, as their CCS values were significantly different from those predicted for the lowest-energy structures. Here, this study demonstrates that gas-phase IM-MS is a powerful technique for detecting subtle size differences in atomically precise NCs, which are often challenging to observe using conventional NC characterization methods. Accurate CCS measurements are established as a benchmark for comparison with theoretical calculations. The excellent correspondence between experimental data and theoretical predictions establishes a robust foundation for investigating structural changes of transition metal NCs of interest to a broad range of applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-dimensional feature matching improves coverage for single-cell proteomics based on ion mobility filtering

Single-cell proteomics (scProteomics) promises to advance our understanding of cell functions within complex biological systems. However, a major challenge of current methods is their inability to identify and provide accurate quantitative information for low abundance proteins. Herein, we describe an ion mobility-enhanced mass spectrometry acquisition and peptide identification method, TIFF (Transferring Identification based on FAIMS Filtering), to improve the sensitivity and accuracy of label-free scProteomics. TIFF extends the ion accumulation times for peptide ions by filtering out singly charged ions. The peptide identities are assigned by a three-dimensional MS1 feature matching approach (retention time, accurate mass, and FAIMS compensation voltage). TIFF method enabled unbiased proteome analysis to a depth of >1,700 proteins in single HeLa cells with >1,100 proteins consistently identified. As a demonstration, we applied the TIFF method to obtain temporal proteome profiles of >150 single murine macrophage cells during lipopolysaccharide stimulation and identified time-dependent proteome changes.

59 BASIC BIOLOGICAL SCIENCES↗

Ambient Ion Trapping and Separations for High Throughput Structurally Selective Material Deposition

While ion mobility coupled to mass spectrometry (IMS/MS) has been increasingly adapted to biological analysis, the structural and molecular specificity offered by IMS/MS has untapped potential for creating novel materials (for energy, catalysis, biomolecular switches etc.) with rationally tailored properties by precisely controlling the chemical structure and composition of these materials. While electrochemical and catalytic properties of the bulk material are understood by mass-selective ion-soft-landing, different structures of one molecule can exhibit distinct properties from the bulk. Many biological phenomenon occur at interfaces and are highly structurally specific. IMS/MS offers means to separate molecules in a sample (which is first ionized and released to gas phase from the condensed phase) based on mass and structure. Species thus separated can potentially be deposited onto surfaces with molecular and structural specificity, to perform fundamental investigations for understanding critical interfacial phenomenon. Key performance metrics for IMS/MS analysis are resolution of separations and sensitivity. Recently developed Structures for Lossless Ion Manipulations (SLIM)4 enabled unprecedented resolution in IMS separations. In addition, high sensitivity was enabled in SLIM due to lossless confinement of ions using radio frequency fields. Thus, SLIM enabled extremely long path length separations (up to 0.1 km thus far) providing efficient separation of molecular ions never before achieved (e.g. isotopologues, D&L amino acids). While SLIM has unprecedented analytical separations power/utility, the use of SLIM platform for depositing mobility and mass selected molecular ions has two specific technological challenges: (a) Pulsed nature of IMS separations and their low duty cycle and (b) the need for a low vacuum of ~4 torr for lossless ion confinement. These limitations lead to long deposition times due to loss of ions generated from the sample. Enabling ion confinement at atmospheric pressure will be path-breaking contribution to the fundamental understanding of ion manipulations and separations and will also enable novel science currently precluded due to the inability of the present technologies to confine ions under ambient conditions. Traditionally used radio frequency fields are ineffective in confining ions at high pressures due to ion/neutral collisions. To address these, we propose to (a) develop methods for confining and manipulating ions for lossless IMS separations at atmospheric pressure enabling high sensitivity and throughput and (b) use the high specificity of IMS/MS and high throughput from ambient ion confinement to perform mobility and mass selective ion deposition at atmospheric pressure. Our goal is to enable the study of the fundamental properties of energy/catalysis materials and biomolecules. This project paves the way for high-throughput, mass and structure selective material deposition for highly specific surface creation/functionalization (discussed in Section 2 of the report). Further, the developments reported continue to push the boundaries of this process to ambient conditions (discussed in Section 3 of the report). We conclude with a list of specific intellectual property and publications which have been the outcome of this funded project.

36 MATERIALS SCIENCE↗

A catalytic dyad modulates conformational change in the CO 2 -fixing flavoenzyme 2-ketopropyl coenzyme M oxidoreductase/carboxylase

2-Ketopropyl-coenzyme M oxidoreductase/carboxylase (2-KPCC) is a member of the flavin and cysteine disulfide containing oxidoreductase family (DSOR) that catalyzes the unique reaction between atmospheric CO 2 and a ketone/enolate nucleophile to generate acetoacetate. However, the mechanism of this reaction is not well understood. Here, we present evidence that 2-KPCC, in contrast to the well-characterized DSOR enzyme glutathione reductase, undergoes conformational changes during catalysis. Using a suite of biophysical techniques including limited proteolysis, differential scanning fluorimetry, and native mass spectrometry in the presence of substrates and inhibitors, we observed conformational differences between different ligand-bound 2-KPCC species within the catalytic cycle. Analysis of site-specific amino acid variants indicated that 2-KPCC-defining residues, Phe501-His506, within the active site are important for transducing these ligand induced conformational changes. We propose that these conformational changes promote substrate discrimination between H + and CO 2 to favor the metabolically preferred carboxylation product, acetoacetate.

59 BASIC BIOLOGICAL SCIENCES↗

Conotoxin Prediction: New Features to Increase Prediction Accuracy

Conotoxins are toxic, disulfide-bond-rich peptides from cone snail venom that target a wide range of receptors and ion channels with multiple pathophysiological effects. Conotoxins have extraordinary potential for medical therapeutics that include cancer, microbial infections, epilepsy, autoimmune diseases, neurological conditions, and cardiovascular disorders. Despite the potential for these compounds in novel therapeutic treatment development, the process of identifying and characterizing the toxicities of conotoxins is difficult, costly, and time-consuming. This challenge requires a series of diverse, complex, and labor-intensive biological, toxicological, and analytical techniques for effective characterization. While recent attempts, using machine learning based solely on primary amino acid sequences to predict biological toxins (e.g., conotoxins and animal venoms), have improved toxin identification, these methods are limited due to peptide conformational flexibility and the high frequency of cysteines present in toxin sequences. This results in an enumerable set of disulfide-bridged foldamers with different conformations of the same primary amino acid sequence that affect function and toxicity levels. Consequently, a given peptide may be toxic when its cysteine residues form a particular disulfide-bond pattern, while alternative bonding patterns (isoforms) or its reduced form (free cysteines with no disulfide bridges) may have little or no toxicological effects. Similarly, the same disulfide-bond pattern may be possible for other peptide sequences and result in different conformations that all exhibit varying toxicities to the same receptor or to different receptors. We present here new features, when combined with primary sequence features to train machine learning algorithms to predict conotoxins, that significantly increase prediction accuracy.

collisional cross section↗

Machine Learning Framework for Conotoxin Class and Molecular Target Prediction

Conotoxins are small and highly potent neurotoxic peptides derived from the venom of marine cone snails which have captured the interest of the scientific community due to their pharmacological potential. These toxins display significant sequence and structure diversity, which results in a wide range of specificities for several different ion channels and receptors. Despite the recognized importance of these compounds, our ability to determine their binding targets and toxicities remains a significant challenge. Predicting the target receptors of conotoxins, based solely on their amino acid sequence, remains a challenge due to the intricate relationships between structure, function, target specificity, and the significant conformational heterogeneity observed in conotoxins with the same primary sequence. We have previously demonstrated that the inclusion of post-translational modifications, collisional cross sections values, and other structural features, when added to the standard primary sequence features, improves the prediction accuracy of conotoxins against non-toxic and other toxic peptides across varied datasets and several different commonly used machine learning classifiers. Here, we present the effects of these features on conotoxin class and molecular target predictions, in particular, predicting conotoxins that bind to nicotinic acetylcholine receptors (nAChRs). We also demonstrate the use of the Synthetic Minority Oversampling Technique (SMOTE)-Tomek in balancing the datasets while simultaneously making the different classes more distinct by reducing the number of ambiguous samples which nearly overlap between the classes. In predicting the alpha, mu, and omega conotoxin classes, the SMOTE-Tomek PCA PLR model, using the combination of the SS and P feature sets establishes the best performance with an overall accuracy (OA) of 95.95%, with an average accuracy (AA) of 93.04%, and an f1 score of 0.959. Using this model, we obtained sensitivities of 98.98%, 89.66%, and 90.48% when predicting alpha, mu, and omega conotoxin classes, respectively. Similarly, in predicting conotoxins that bind to nAChRs, the SMOTE-Tomek PCA SVM model, which used the collisional cross sections (CCSs) and the P feature sets, demonstrated the highest performance with 91.3% OA, 91.32% AA, and an f1 score of 0.9131. The sensitivity when predicting conotoxins that bind to nAChRs is 91.46% with a 91.18% sensitivity when predicting conotoxins that do not bind to nAChRs.

59 BASIC BIOLOGICAL SCIENCES↗

Mass spectrometry in the U.S. space program: past, present, and future

Recent years have witnessed significant progress on the miniaturization of mass spectrometers for a variety of field applications. This article describes the development and application of mass spectrometry (MS) instrumentation to support of goals of the U.S. space program. Its main focus is on the two most common space-related applications of MS: studying the composition of planetary atmospheres and monitoring air quality on manned space missions. Both sets of applications present special requirements in terms of analytical performance (sensitivity, selectivity, speed, etc.), logistical considerations (space, weight, and power requirements), and deployment in perhaps the harshest of all possible environments (space). The MS instruments deployed on the Pioneer Venus and Mars Viking Lander missions are reviewed for the purposes of illustrating the unique features of the sample introduction systems, mass analyzers, and vacuum systems, and for presenting their specifications which are impressive even by today's standards. The various approaches for monitoring volatile organic compounds (VOCs) in cabin atmospheres are also reviewed. In the past, ground-based GC/MS instruments have been used to identify and quantify VOCs in archival samples collected during the Mercury, Apollo, Skylab, Space Shuttle, and Mir missions. Some of the data from the more recent missions are provided to illustrate the composition data obtained and to underscore the need for instrumentation to perform such monitoring in situ. Lastly, the development of two emerging technologies, Direct Sampling Ion Trap Mass Spectrometry (DSITMS) and GC/Ion Mobility Spectrometry (GC/IMS), will be discussed to illustrate their potential utility for future missions. c 2001 American Society for Mass Spectrometry.

NASA Discipline Environmental Health↗

Charged Microdroplets in Air: Characterization and Use in Surface Functionalization and Nanomaterials Preparation (Final Technical Report)

The major theme of this project is the exploration of ions and charged droplets in the open air. The specific goals are (1) focusing ions in the open air, (2) separating and measuring the sizes of charged droplets, (3) examining chemical reactions occurring within droplets, (4) examining chemical reactions occurring between charged droplets and chemical vapors, and (5) characterizing surfaces post droplet deposition. The analysis of ions in the open air greatly simplifies instrumentation as it removes the need for large, costly vacuum pumps. Major strides in this project include the sizing of electrospray droplets using structured illumination microscopy, 3D printed drift tube ion mobility (both standalone and coupled with mass spectrometry), and accelerated Suzuki reactions in Leidenfrost droplets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micro-machined planar field asymmetric ion mobility spectrometer as a gas chromatographic detector

A planar high field asymmetric waveform ion mobility spectrometer (PFAIMS) with a micro-machined drift tube was characterized as a detector for capillary gas chromatography. The performance of the PFAIMS was compared directly to that of a flame ionization detector (FID) for the separation of a ketone mixture from butanone to decanone. Effluent from the column was continuously sampled by the detector and mobility scans could be obtained throughout the chromatographic analysis providing chemical inforrmation in mobility scans orthogonal to retention time. Limits of detection were approximately I ng for measurement of positive ions and were comparable or slightly better than those for the FID. Direct comparison of calibration curves for the FAIMS and the FID was possible over four orders of magnitude with a semi-log plot. The concentration dependence of the PFAIMS mobility scans showed the dependence between ion intensity and ion clustering, evident in other mobility spectrometers and atmospheric pressure ionization technologies. Ions were identified using mass spectrometry as the protonated monomer and the proton bound dimer of the ketones. Residence time for column effluent in the PFAIMS was calculated as approximately 1 ms and a 36% increase in extra-column broadening versus the FID occurred with the PFAIMS.

NASA Discipline Life Sciences Technologies↗

Atmospheric-pressure ionization and fragmentation of molecules for structural elucidation

A solution-cathode glow discharge (SCGD) spectrometry apparatus may comprise an SCGD source and a mass or ion mobility spectrometer. A method for ionizing a molecular analyte may comprise contacting the molecular analyte with a plasma discharge to form ions and separating the ions in a mass spectrometer or ion mobility spectrometer. The contacting step may occur under atmospheric pressure and/or ambient conditions. The molecular analyte may be fragmented by the plasma discharge.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploration of Electrochemical Reactions at Organic–Inorganic Halide Perovskite Interfaces via Machine Learning in In Situ Time-of-Flight Secondary Ion Mass Spectrometry

The instability of hybrid organic–inorganic perovskite (HOIP) devices is one of the significant challenges preventing commercialization. Exploring these phenomena is severely limited by the complexity of the intrinsic electrochemistry of HOIPs, the presence of multiple volatile and mobile ionic species, and the possible role of environmentally induced reactions at surfaces and triple-phase junctions. Here, in situ studies of the electrochemistry of methylammonium lead bromide perovskite with the Au electrode interface are reported via light- and voltage-dependent time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging of lateral perovskite heterostructures. While ToF-SIMS allows for the visualization of the chemical composition along the surface and its evolution with light and electrical bias, the interpretation of the multidimensional data obtained is often limited due to strong correlations between chemical signatures and the need to track multiple peaks at once. Here, a machine learning workflow combining the Hough transform and non-negative matrix factorization and no-negative tensor decomposition is developed to avoid this limitation and extract salient features of associated chemical changes and to separate the light- and voltage-dependent dynamics. Finally, combining these in situ characterizations and the machine learning workflow provides comprehensive information on the chemical nature of moving species, ion accumulation, and interfacial electrochemical reactions in HOIP devices.

36 MATERIALS SCIENCE↗

Reducing ion diffusion at atmospheric pressure through intermingled positive and negative ions

Increasing ion molecule reaction times for ambient ionization techniques can increase sensitivity of detection. Longer reaction times result in an increase in analyte signal relative to the reactant ion signal, however with a subsequent decrease in the total ion intensity. This loss in the total number of ions reaching the detector limits the extent to which increased reaction time can improve detection in practical applications. In this study ion loss was measured using either electric fields or gas flow to control ion transit time. Ion transit times ranged from 40 ms to 8s, which resulted in ion densities ranging from 5 x 10 6 to 2 x 10 4 ions/cm 3 , respectively. These results provide insights into practical reaction time limitations or experimental boundaries when exploring sensitivity enhancements in ambient ionization. When exploring longer reaction times with an atmospheric flow tube coupled to a mass spectrometer (AFT-MS), an additional corona discharge ionization source of the same polarity was added in an attempt to increase total ion signal, but no improvement in signal was observed. This observation suggested that there was a maximum ion density being reached by the corona discharge that could not be increased by adding more of the same polarity ions. A hypothesis was that intermingling both polarities of ions would reduce ion loss and increase the measured ion signal. When two corona discharge sources—one each of positive and negative polarity—were used simultaneously in an AFT-MS, the total ion signal of either polarity measured by the MS was approximately double the current from a single corona discharge source. An increase in the negative ion signal was also observed when ~10 parts-per-trillion vapor levels of an explosive (RDX) were introduced. In this case both the nitrate reactant ions and the RDX signal more than doubled with the addition of a corona discharge source producing positive ions. When intermingling positive and negative ions, an increase in ion current was also observed when the AFT was coupled directly to a Faraday detector or to an ion mobility spectrometer. This was the first demonstration of interfacing the AFT to an IMS. The observations and developments from this work will help in creating more portable instruments with improved sensitivity for detection of chemicals.

47 OTHER INSTRUMENTATION↗

Evidence of lithium mobility under neutron irradiation

Understanding the evolution of intermetallic materials in high-radiation environments is of great importance for fusion science and national security. Tritium ( 3 H) and lithium ( 6 Li, 7 Li) transport within neutron irradiated claddings coated with aluminide (FeAl3) has been investigated using state-of-the-art multimodal imaging. Specifically, scanning electron microscopy – focused ion beam (SEM-FIB) was used to prepare irradiated coating lift-out samples for follow-on microanalysis. Here, scanning transmission electron microscopy (STEM) was used to acquire atomic-scale information on the carbonaceous structure and elemental mapping. Atomic force microscopy (AFM) was used to determine lift-out dimensions nondestructively. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) spectral and depth profiling show unexpected lithium isotopic distributions in the irradiated cladding, raising an important evidence of possible light isotope mobility within the cladding under elevated temperature and irradiation. ToF-SIMS three-dimensional chemical mappings of mid- and bottom-cladding coatings show light isotopic (e.g., 3 H, 6 Li, 7 Li) distributions in the irradiated coating and give new insights into the fundamental mechanism related to transport mechanisms within the cladding. Multimodal imaging is power to link microstructure, chemistry, and nanoscale defects that impact reliability of these materials. Furthermore, chemical mapping offers observations of the microstructural evolution due to irradiation and provides insights into unexpected material transport under extreme conditions.

36 MATERIALS SCIENCE↗

Direct analysis of organic priority pollutants by IMS

Many routine methods for monitoring of trace amounts of atmospheric organic pollutants consist of several steps. Typical steps are: (1) collection of the air sample; (2) trapping of organics from the sample; (3) extraction of the trapped organics; and (4) identification of the organics in the extract by GC (gas chromatography), HPLC (High Performance Liquid Chromatography), or MS (Mass Spectrometry). These methods are often cumbersome and time consuming. A simple and fast method for monitoring atmospheric organics using an IMS (Ion Mobility Spectrometer) is proposed. This method has a short sampling time and does not require extraction of the organics since the sample is placed directly in the IMS. The purpose of this study was to determine the responses in the IMS to organic 'priority pollutants'. Priority pollutants including representative polycyclic aromatic hydrocarbons (PAHs), phthalates, phenols, chlorinated pesticides, and polychlorinated biphenyls (PCB's) were analyzed in both the positive and negative detection mode at ambient atmospheric pressure. Detection mode and amount detected are presented.

Giam, C. S.↗

Apolipoprotein A-I modulates HDL particle size in the absence of apolipoprotein A-II

Human high-density lipoproteins (HDLs) are a complex mixture of structurally related nanoparticles that perform distinct physiological functions. We previously showed that human HDL containing apolipoprotein A-I (APOA1) but not apolipoprotein A-II (APOA2), designated LpA-I, is composed primarily of two discretely sized populations. Here, we isolated these particles directly from human plasma by antibody affinity chromatography, separated them by high-resolution size-exclusion chromatography and performed a deep molecular characterization of each species. The large and small LpA-I populations were spherical with mean diameters of 109 Å and 91 Å, respectively. Unexpectedly, isotope dilution MS/MS with [ 15 N]-APOA1 in concert with quantitation of particle concentration by calibrated ion mobility analysis demonstrated that the large particles contained fewer APOA1 molecules than the small particles; the stoichiometries were 3.0 and 3.7 molecules of APOA1 per particle, respectively. MS/MS experiments showed that the protein cargo of large LpA-I particles was more diverse. Human HDL and isolated particles containing both APOA1 and APOA2 exhibit a much wider range and variation of particle sizes than LpA-I, indicating that APOA2 is likely the major contributor to HDL size heterogeneity. We propose a ratchet model based on the trefoil structure of APOA1 whereby the helical cage maintaining particle structure has two “settings”—large and small—that accounts for these findings. This understanding of the determinants of HDL particle size and protein cargo distribution serves as a basis for determining the roles of HDL subpopulations in metabolism and disease states.

59 BASIC BIOLOGICAL SCIENCES↗

A volatile organic analyzer for Space Station: Description and evaluation of a gas chromatography/ ion mobility

A Volatile Organic Analyzer (VOA) is being developed as an essential component of the Space Station's Environmental Health System (EHS) air quality monitoring strategy to provide warning to the crew and ground personnel if volatile organic compounds exceed established exposure limits. The short duration of most Shuttle flights and the relative simplicity of the contaminant removal mechanism have lessened the concern about crew exposure to air contaminants on the Shuttle. However, the longer missions associated with the Space Station, the complex air revitalization system and the proposed number of experiments have led to a desire for real-time monitoring of the contaminants in the Space Station atmosphere. Achieving the performance requirements established for the VOA within the Space Station resource (e.g., power, weight) allocations led to a novel approach that joined a gas chromatograph (GC) to an ion mobility spectrometer (IMS). The authors of this paper will discuss the rational for selecting the GC/IMS technology as opposed to the more established gas chromatography/mass spectrometry (GC/MS) for the foundation of the VOA. The data presented from preliminary evaluations will demonstrate the versatile capability of the GC/IMS to analyze the major contaminants expected in the Space Station atmosphere. The favorable GC/IMS characteristics illustrated in this paper included excellent sensitivity, dual-mode operation for selective detection, and mobility drift times to distinguish co-eluting GC peaks. Preliminary studies have shown that the GC/IMS technology can meet surpass the performance requirements of the Space Station VOA.

Limero, Thomas F.↗

FeS colloids – formation and mobilization pathways in natural waters

For this study, we have used synchrotron-based X-ray absorption spectroscopy (structure of Fe–S clusters), transmission electron microscopy (solid-phase crystallinity), Fourier-transform ion-cyclotron-resonance mass spectrometry (identity and composition of natural organic carbon compounds), inductively coupled plasma optical emission spectrometry (total aqueous Fe), and the revised ferrozine method (aqueous Fe( II ) and Fe( III ) concentrations) to determine the stability and nature of colloids generated by sulfidation of ferrihydrite nanoparticles in the absence and presence of organic compounds. We observed that reductive dissolution of ferrihydrite by aqueous sulfide generates nm-scale FeS clusters. Their subsequent aggregation, which promotes settling of FeS aggregates into the solid fraction, was directly correlated with sulfide/Fe ratio. At sulfide/Fe ratios ≤0.5, FeS clusters and larger colloids remained in suspension for at least 14 days (and up to several months). At sulfide/Fe ratios >0.5, sulfidation reaction rates were rapid and FeS cluster aggregation was accelerated. Moreover, the presence of organic compounds increased the time of suspension of FeS colloids, whereas increased ionic strength inhibited the generation of FeS colloids. We present a general conceptual model to predict when and where FeS colloids can form and enhance or inhibit the mobility of contaminants and nutrients associated with them. Our study indicates that in lowsalinity fresh groundwater systems poor in sulfate (i.e. low sulfidation; lakes, floodplains, peatlands etc.), the ferrihydrite sulfidation reaction generates aqueous FeS clusters and larger colloids that remain suspended over long time periods, thus mobilizing a substantial fraction of the total aqueous Fe and S.

54 ENVIRONMENTAL SCIENCES↗