Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion mobility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

High resolution mobility spectrometry in a co-axial platform

Ion mobility spectrometry is an analytical technique that separate ions in the gas phase based on their interaction with a neutral buffer gas. Ion mobility spectrometry performs separations quickly (typically less than a second) and the ion mobilities are very reproducible across different laboratories. This project aimed at evaluating the performance of a new ion mobility device. The new device relies on conducting ion mobility separation in a curved geometry. The project explored the operation landscape of the device using ion trajectory simulations then fabricated and experimentally demonstrated the device's performance. Ion trajectory simulations on a set of tetraalkylammonium and phosphazene ions indicate that ions traveling a curved path length undergo mobility separation that is similar to a straight path. The ion mobility resolution of the curved device was found to be similar to that of a straight path of a similar length. The experimental validation of the new device confirmed the device's ability to separate ions according to their mobilities. Sets of mixtures (tetraalkylammonium ions, phosphazene ions, and peptide ions) were evaluated for separation and transmission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mobility Selective Ion Soft-Landing and Characterization Enabled Using Structures for Lossless Ion Manipulation

In this study, while conventional ion-soft landing uses the mass-to-charge (m/z) ratio to achieve molecular selection for deposition, here we demonstrate the use of Structures for Lossless Ion Manipulation (SLIM) for mobility-based ion selection and deposition. The dynamic rerouting capabilities of SLIM were leveraged to enable the rerouting of a selected range of mobilities to a different SLIM path (rather than MS) that terminated at a deposition surface. A selected mobility range from a phosphazene ion mixture was rerouted and deposited with a current pulse (~150 pA) resembling its mobility peak. In addition, from a mixture of tetra-alkyl ammonium (TAA) ions containing chain lengths of C5–C8, selected chains (C6, C7) were collected on a surface, reconstituted into solution-phase, and subsequently analyzed with a SLIM-qToF to obtain an IMS/MS spectrum, confirming the identity of the selected species. Further, this method was used to characterize triply charged tungsten-polyoxometalate anions, PW 12 O 40 3– (WPOM). The arrival time distribution of the IMS/MS showed multiple peaks associated with the triply charged anion (PW 12 O 40 3– ), of which a selected ATD was deposited and imaged using TEM. Additionally, the identity of the deposited WPOM was ascertained using energy-dispersive (EDS) spectroscopy. Further, we present theory and computations that reveal ion landing energies, the ability to modulate the energies, and deposition spot sizes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identification of Unique Fragmentation Patterns of Fentanyl Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry

The opioid crisis in the United States is being fueled by the rapid emergence of new fentanyl analogs and precursors that can elude traditional library-based screening methods, which require data from known reference compounds. Since reference compounds are unavailable for new fentanyl analogs, we examined if fentanyls (fentanyl + fentanyl analogs) could be identified in a reference-free manner using a combination of electrospray ionization (ESI), high-resolution ion mobility (IM) spectrometry, high-resolution mass spectrometry (MS), and higher-energy collision-induced dissociation (MS/MS). We analyzed a mixture containing nine fentanyls and W-15 (a structurally similar molecule) and found that the protonated forms of all fentanyls uniquely exhibited two baseline separated IM distributions that produced different MS/MS patterns. Upon fragmentation, both IM distributions of all fentanyls produced two high intensity fragments resulting from amine site cleavages. The higher mobility distributions of all fentanyls also produced several low intensity fragments, but surprisingly, these same fragments exhibited much greater intensities in the lower mobility distributions. This observation demonstrates that many fragments of fentanyls predominantly originate from one of two different gas-phase structures (suggestive of protomers). Furthermore, increasing the water concentration in the ESI solution increased the intensity of the lower mobility distribution relative to the higher mobility distribution, which further supports that fentanyls exist as two gas-phase protomers. In conclusion, our new observations on the IM and MS/MS properties of fentanyls can be exploited to positively identify them as fentanyls without requiring reference libraries and will hopefully assist first responders and law enforcement in combating new and emerging fentanyls.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating the Gas-Phase Behavior of Nitazene Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry

2-benzylbenzimidazoles, or “nitazenes”, are a class of novel synthetic opioids (NSOs) that are increasingly being detected alongside fentanyl analogs and other opioids in drug overdose cases. Nitazenes can be 20x more potent than fentanyl but are not routinely tested for during postmortem or clinical toxicology drug screens; thus, their prevalence in drug overdose cases may be under-reported. Traditional analytical workflows utilizing liquid chromatography-tandem mass spectrometry (LC-MS/MS) often require additional confirmation with authentic reference standards to identify a novel nitazene. However, additional analytical measurements with ion mobility spectrometry (IMS) may provide a path towards reference-free identification, which would greatly accelerate NSO identification rates in toxicology labs. Presented here are the first IMS and collision cross section (CCS) measurements on a set of fourteen nitazene analogs using a Structures for Lossless Ion Manipulations (SLIM)-Orbitrap MS. All nitazenes exhibited two high intensity baseline-separated IMS distributions, which fentanyls and other drug and drug-like compounds also exhibit. Incorporating water into the electrospray ionization (ESI) solution caused the intensities of the higher mobility IMS distributions to increase the intensities of the lower mobility IMS distributions to decrease. Nitazenes lacking a nitro group at the R1 position exhibited the greatest shifts in signal intensities due to water. Furthermore, IMS-MS/MS experiments showed that the higher mobility IMS distributions of all nitazenes produced fragment ions with m/z 72, 100, and other low intensity fragments while the lower mobility IMS distributions only produced fragment ions with m/z 72 and 100. The IMS, solvent, and fragmentation studies provide experimental evidence that nitazenes potentially exhibit three gas-phase protomers. In conclusion, the cyclic IMS capability of SLIM was also employed to partially resolve four sets of structurally similar nitazene isomers (e.g., protonitazene/isotonitazene, butonitazene/isobutonitazene/secbutonitazene), showcasing the potential of using high-resolution IMS separations in MS-based workflows for reference-free identification of emerging nitazenes and other NSOs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrical properties of the middle atmosphere

Probe techniques have been utilized extensively to measure middle atmospheric electrical properties such as the polar components of conductivity, ion mobility and density. The most variable of these parameters is conductivity, which is dependent on both charge mobility and concentration. Overall conductivity variations, attributable to different geophysical conditions, can exceed several orders of magnitude at some altitudes. Also, measurements of conductivity over the 20 to 90 km region indicate a general exponential increase with altitude, exceeding seven orders of magnitude during certain conditions. Gerdien condensers, on occasion, have measured very low-mobility positive ions in addition to the more commonly observed molecular species. These smaller mobility values appear to indicate the presence of very large ions at some altitudes, possibly charged particulates, having mass sizes greater than those identifiable by presently flown mass spectrometers. The presence of these large ions is of importance to middle atmospheric electrodynamics as a potential causal mechanism for measured large electric fields.

Mitchell, John D.↗

Dynamics of Electric Polarization and Relaxation of Ions at Humid Calcite Surfaces

Mobile ions at mineral surfaces can respond to an applied electric field, adopting a new distribution that effectively represents polarization of the electrical double layer. When the field is released, the ions relax to their equilibrium distribution. In both cases, the dynamics are characteristic of the interface. However, current models of electrokinetic phenomena are not sufficiently robust to accurately predict collective ion dynamics at structurally and chemically specific mineral–water interfaces. Here, in this study, we use electrostatic force microscopy (EFM) to investigate the dynamics of ion relaxation at hydrated calcite (104) surfaces at controlled relative humidity (RH). Electrically biased probes are used to polarize the distributions of calcium and carbonate ions that are intrinsic to this interface across a range of RH values. Polarization kinetics are tracked by monitoring the tip–sample force gradient during charging, and EFM imaging is used to characterize the spatial relaxation dynamics after the applied field is released. Electrostatic finite element modeling of the sample/probe system across length-scales from nanometers to millimeters reproduces the observed stretched exponential charging response. Together, these results allow us to estimate the ion diffusivities at the interface across a wide range of RH values. These diffusivities increase by roughly 5 orders of magnitude as the RH is increased from 5 to 90%, highlighting the critical role of adsorbed water for surface ion solvation that enables ion mobility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Middle-atmosphere positive ion measurements during solar eclipses

Solar effects on middle-atmosphere electrical parameters, as demonstrated by eclipse-associated responses of conductivity, ion mobility, and charge density, are considered for the total solar eclipses at Red Lake, Ontario, Canada on February 26, 1979 and at San Marco range, Kenya, on February 16, 1980. Negative-conductivity measurements for the Canadian eclipse and probe-current measurements for the Kenyan eclipse demonstrate a rapid loss of free electrons below 80 km at totality. During the Kenyan eclipse, positive-ion responses were different for each of two distinct ion mobility groups. Between 45 and 60 km, eclipse-related positive-ion responses are associated with the low-mobility ions. It is shown that these ions are lost at totality and that an excess buildup occurs following totality. Above 70 km, positive-ion loss at totality is associated with the more mobile ions and only low-mobility positive ions are measured in this region. The buildup in total ion density following totality is thought to result from a reduction in ion loss associated with weak-electron recovery in the region.

Mitchell, J. D.↗

Application of Ni-63 photo and corona discharge ionization for the analysis of chemical warfare agents and toxic wastes

Over the past decade, advances in instrumental design and refinements in the understanding of ion molecule reactions at atmospheric pressure enabled the application of Ion Mobility Spectrometry (IMS) as a simple inexpensive and sensitive analytical method for the detection of organic trace compounds. Positive and negative gas-phase ions for ion mobility spectrometry have been produced by a variety of methods, including photo-ionization, laser multi photon ionization, surface ionization, corona discharge ionization. The most common ion source used in ion mobility spectrometry is a radioactive Ni-63 foil which is favored due to simplicity, stability, convenience, and high selectivity. If reactant ions like (H2O(n)H)(+) or (H2O(n)O2)(-) dominate in the reaction region, nearly all kinds of compounds with a given proton or electron affinity; are ionized. However, the radioactivity of the Ni-63 foil is one disadvantage of this ion source that stimulates the development and application of other ionization techniques. In this paper, we report analyses of old chemical warfare agents and toxic wastes using Bruker RAID ion mobility spectrometers. Due to the modular construction of the measuring cell, the spectrometers can be equipped with different ion sources. The combined use of Ni-63, photo- and corona discharge ionization allows the identification of different classes of chemical compounds and yields in most cases comparable results.

Stach, J.↗

Heat Transfer Fluids as Co‐Diluents in Localized High‐Concentration Electrolytes for High‐Rate Lithium Metal Batteries With Enhanced Safety

Localized high-concentration electrolytes (LHCEs) have been identified as promising electrolyte formulations for lithium metal batteries, due to their effective interphase formation and promotion of compact Li deposition, yet their practical implementation is often limited by reduced ion transport kinetics. In this study, two industrially established fluorinated ethers are identified for the first time in battery research as effective co-diluents as they combine a broad electrochemical stability window with a low viscosity and intrinsic non-flammability. Incorporating these components, commonly used as heat transfer fluids, yields safer, less flammable electrolyte formulations with enhanced ion mobilities. In particular, the ternary co-diluent formulation shows improved ion mobility by reducing the electrolyte's viscosity while limiting excessive ion clustering. Based on the improved electrolyte transport kinetics, lower overvoltages and higher Coulombic efficiencies at current densities ≥ 1 mA cm −2 are achieved with the ternary co-diluent blend, resulting in markedly extended cycle life in an application-oriented zero-excess pouch cell compared with the baseline system. Complementary electrochemical and ex situ analysis of harvested electrodes at moderate current densities reveals no discernible differences in interphase morphology and composition, suggesting enhanced ion mobility as the primary cause of the improved high-rate performance.

electrolyte diluent↗

The pinhole interface for IMS/MS

An important supplementary technique for ion mobility spectrometry (IMS) is mass spectrometry (MS). A mass spectrometer coupled to an ion mobility spectrometer (IMS/MS) can provide significant information on the composition of the ions contributing to an ion mobility peak. On the other hand, the interpretation of IMS/MS results requires knowledge of processes which can occur at the pinhole interface. When the ion composition is a mixture of ion clusters, the observed cluster distribution may not be an accurate representation of the ion clusters in the IMS. Depending on the buffer gas, lower clusters can form by equilibrating with reduced concentrations in the continuum regime of the expansion and larger clusters can form by collisional stabilization in the cooled jet stream. Besides water, nitrogen molecules can also add to the ion clusters. Even though nitrogen is non-polar, this addition is made possible by an ion-induced dipole interaction between the ion and molecule.

Spangler, Glenn E.↗

Electrospray Ionization/Ion Mobility Spectrometer/Cylindrical Ion Trap Mass Spectrometer System for In-Situ Detection of Organic Compounds

The potential of an Electrospray Ionization/Ion Mobility Spectrometer/Cylindrical Ion Trap Mass Spectrometer (ESI/IMS/CIT-MS) as an analytical instrument for analyzing material extracted from rock and soil samples as part of a suite of instruments on the proposed 2009 Mars Science Lander (MSL) will be demonstrated. This instrument will be able to identify volatile compounds as well as resident organic molecules on the parts-per-billion (ppb) level. Also, it will be able to obtain an inventory of chemical species on the surface of Mars which will result in a better understanding of ongoing surface chemistry. Finally, questions relevant to biological processes will be answered with the complete inventory of surface and near surface organic molecules that the ESI/IMS/CIT is capable of performing.

Kanik, I.↗

Ion properties of the high-latitude middle-atmosphere

Investigations of high-latitude, middle-atmosphere ion properties have been conducted using rocket probe techniques. Electrodynamics studies have addressed: mesospheric dynamics and small-scale structure (the MAC/EPSILON Campaign during October-November 1977); ionization effects associated with highly energetic greater than or equal to 1 MeV) precipitating electrons (the MAC/REP Program during May 1990); and the characteristics of noctilucent cloud (NLC) and polar mesosphere summer echo (PMSE) regions (the NLC-91 Campaign during July-August 1991). Recent developments in Gerdien condenser probe theory, using computational fluid dynamics to model ion collection, have resulted in more accurate evaluation of the ion mobilities and number densities. Measurements of very small ion mobilities are thought to indicate an aerosol ion presence in the upper mesosphere.

Li, C.↗

ICR study of nonreactive ion-molecule collision rate constants for Cl/-/ and Cr/CO/5/-/

Determination of experimental momentum transfer rate constants for systems of Cl(-) and Cr(CO)5(-) ions by means of an ion cyclotron resonance (ICR) line-broadening technique. It is found that in the pure polarization limit of small ion/large neutral collisions the Langevin ion mobility theory gives good agreement with experimental results. A comparison of isotropic and anisotropic neutral systems suggests that a correction for the anisotropic systems is necessary. Beyond the pure polarization limit the Langevin theory gives poor predictions for ion mobilities. The adjustable parameter, gamma, of the Mason-Schamp (12-6-4) potential function permits unique solution of the ion mobility for Cr(CO)5(-) in a wide range of neutral gases. The large values of gamma obtained for most of these systems imply, in terms of the Mason-Schamp theory, that the r to the minus 6th power contribution to the potential function is significant.

Dymerski, P. P.↗

Dynamical Ion Correlations in Polymer and Membrane Electrolytes: Recent Advances and Open Questions

Ion transport in polymer and membrane electrolytes is often described using uncorrelated models like the Nernst–Einstein (NE) approximation, which link conductivity, transference number, and salt diffusivity to individual ion mobilities. However, growing evidence shows that dynamical ion correlations─arising from ion pairing, polymer-mediated coupling, confinement, and electrostatic interactions─can substantially alter macroscopic transport properties. The Onsager transport formalism offers a rigorous framework to quantify these effects via cross-correlated ionic displacements. This Perspective highlights how such correlations manifest across dry and hydrated systems, including salt-doped polymers, block copolymers, hydrogels, and ion-exchange membranes. Here, we examine key physical origins, the influence of salt chemistry and polymer structure, and open questions in measuring and controlling correlated motion. Embracing correlation-aware design enables new pathways to optimize conductivity, transference number, and selectivity─shifting the focus from individual ion mobility to engineered collective dynamics for next-generation electrolytes in energy storage and separations.

Charge transport↗

Defect-driven anomalous transport in fast-ion conducting solid electrolytes

We report solid-state ionic conduction is a key enabler of electrochemical energy storage and conversion. The mechanistic connections between material processing, defect chemistry, transport dynamics, and practical performance are of considerable importance, but remain incomplete. Here, inspired by studies of fluids and biophysical systems, we re-examine anomalous diffusion in the iconic two-dimensional fast-ion conductors, the β- and β"-aluminas. Using large-scale simulations, we reproduce the frequency dependence of alternating-current ionic conductivity data. We show how the distribution of charge-compensating defects, modulated by processing, drives static and dynamic disorder, which lead to persistent sub-diffusive ion transport at macroscopic timescales. We deconvolute the effects of repulsions between mobile ions, the attraction between the mobile ions and charge-compensating defects, and geometric crowding on ionic conductivity. Our quantitative framework based on these model solid electrolytes connects their atomistic defect chemistry to macroscopic performance with minimal assumptions and enables mechanism-driven 'atoms-to-device' optimization of fast-ion conductors.

25 ENERGY STORAGE↗

Enhancing Top-Down Proteomics of Brain Tissue with FAIMS

Proteomic investigations of Alzheimer’s and Parkinson’s disease have provided valuable insights into neurodegenerative disorders. Thus far, these investigations have largely been restricted to bottom-up approaches, hindering the degree to which one can characterize a protein’s “intact” state. Top-down proteomics (TDP) overcomes this limitation, however it is typically limited to observing only the most abundant proteoforms and of a relatively small size. Therefore, offline fractionation techniques are commonly used to reduce sample complexity, limiting throughput. A higher throughput alternative is online fractionation, such as gas phase high-field asymmetric waveform ion mobility spectrometry (FAIMS). Using a high complexity sample derived from Alzheimer’s disease brain tissue, we describe how the addition of FAIMS to TDP can robustly improve the depth of proteome coverage. For example, implementation of FAIMS at -50 compensation voltage (CV) more than doubled the mean number of non-redundant proteoforms observed (1,833 ± 17, n = 3), compared to without (754 ± 35 proteoforms). We also found FAIMS can influence the transmission of proteoforms and their charge envelopes based on their size. Importantly, FAIMS enabled the identification of intact amyloid beta (Aß) proteoforms, including the aggregation-prone Aß1-42 variant which is strongly linked to Alzheimer’s disease.

59 BASIC BIOLOGICAL SCIENCES↗