Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “inverter testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Split phase inverter data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 8.35 kW off-the-shelf grid following split phase PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV Inverter Experimental Dataset Version 2 with 100 Percent Power

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. The PV inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

14 SOLAR ENERGY↗

PV inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Due to the limitations of the DC supply used, inverter is tested under 75%, 50%, 25% load conditions (This dataset does not contain 100% load condition). In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development and testing of a 20-kHz component test bed

A history of the General Dynamics Space Systems Division 20 kHz Breadboard is presented including its current configuration and its role in the Space Station Freedom (SSF) program. Highlights and results are presented on a series of tests conducted on the 20 kHz Breadboard. The first test presented is the 20 kHz Breadboard Acceptance test. This test verified the operation of the delivered Breadboard and also characterized the main components of the system. Next, an indepth efficiency testing effort is presented. The tests attempted to apportion all the power losses in the 20 kHz Breadboard Main Invert Units. Distortion test data is presented showing the distortion characteristics of a Mapham inverter. Lastly, current work on the 20 kHz Breadboard is presented including Main Inverter Unit paralleling tests. Conclusions are summarized and references given.

Button, Robert M.↗

Development and testing of a 20 kHz component test bed

A history of the General Dynamics Space Systems Division 20-kHz breadboard is presented, including its current configuration and its role in the SSF program. Highlights and results are presented of a series of tests conducted on the 20 kHz breadboard. The first test presented is the 20 kHz Breadboard Acceptance test. This test verified the operation of the delivered Breadboard and also characterized the main components of the system. Next, an in-depth efficiency testing effort is presented. The tests attempted to apportion all the power losses in the 20 Hz Breadboard Main Inverter Units. Distortion test data are presented, showing the distortion characteristics of a Mapham inverter. Lastly, current work on the 20 kHz Breadboard is presented including Main Inverter Unit paralleling tests. Conclusions are summarized and references given.

Button, Robert M.↗

Free-Spinning Characteristics of a 1/30-Scale Model of the Grumman WF-2 Airplane

An investigation was conducted in the Langley 20-foot free-spinning tunnel on a 1/30-scale model of the Grumman WF-2 airplane. The effects of control settings and movements upon the erect-spin and recovery characteristics for the flight gross-weight loading with normal center-of-gravity and rearward center-of-gravity positions were determined. For the inverted-spin tests, the flight gross-weight loading with normal center-of-gravity position was used. Brief tests were also made with the radome removed to determine the effect of the radome on the spin and recovery characteristics of the airplane. The results of the tests of the model indicate that erect spins of the airplane in the flight gross-weight loading with the normal (26.3-percent mean aerodynamic chord) center-of-gravity position and with the most rearward (30-percent mean aerodynamic chord) center-of-gravity position possible will be satisfactorily terminated by full rudder reversal to against the spin accompanied by movement of the elevator to at least two-thirds down. With the radome removed, the spin will be steeper and considerably more oscillatory than with the radome on. Recoveries by the preceding technique will be satisfactory. Inverted spins of the airplane will be satisfactorily terminated by full rudder reversal followed by neutralization of the longitudinal and lateral controls.

Lee, Henry A.↗

Free-Spinning and Recovery Characteristics of a 1/19-Scale Model of the North American T-28C Airplane, TED No. NACA AD 3127

An investigation has been conducted in the Langley 20-foot free-spinning tunnel on a l/19-scale model of the North American T-28C airplane to determine the spin and recovery characteristics. The T-28C airplane is similar to the T-28B airplane except for slight modifications for the arresting hook. The lower rear section of the fuselage was cut out and, consequently, the lower part of the rudder was removed to make a smooth fairing with the fuselage. The T-28B airplane had good recovery characteristics; but these modifications, along with the addition of gun packages on the wings, led to poor and unsatisfactory spin-recovery characteristics during demonstration spins of the T-28C airplane. Model test results indicated that without the gun packages installed, satisfactory recoveries could be obtained if the elevators were held full back while the rudder was fully reversed and the ailerons were held neutral. However, with the addition of gun packages to the wings and the corresponding change in loading, recoveries were considered unsatisfactory. Recoveries attempted by using a larger chord or larger span rudder were improved very slightly, but were still considered marginal or unsatisfactory. Strakes placed on the nose of the model were effective in slowing the spin rotation slightly and, in most instances, decreased the turns for recovery slightly. Recovery characteristics were slightly marginal for the full fuel loading when strakes and the extended-chord rudder were installed; but with the wing fuel partly used, recovery characteristics were again considered unsatisfactory or, at least, definitely on the marginal side. The optimum control technique for recovery is movement of the rudder to full against the spin with the stick held full back (elevators full up) and the ailerons held neutral, followed by forward movement of the stick only after the spin rotation ceases. Inverted-spin test results indicate that the airplane will spin steep and fast and that recovery by full rudder reversal will be satisfactory if the ailerons are held neutral.

Bowman, James S., Jr.↗

Interpretation of borehole strain measurements using surrogate modeling-based optimization

Interpreting strain data measured during well testing requires inverting poroelastic forward models set up to represent an aquifer or reservoir. One approach is to use stochastic methods to conduct the inversion. Subsurface parameters such as elastic modulus, permeability, and geometry of heterogeneities are estimated by searching the parameter space. This is feasible, but cumbersome, requiring more than a week of computation using many hundreds of computer nodes in one of our earlier analyses. This motivated us to consider alternative methods, including an artificial neural network (ANN) as a surrogate model.

Roudini, Soheil↗

Dynamic Inverter Characterization for Modeling

The goal of the project was to develop data to be used for modeling the dynamic characteristics of smart inverters. The inverters were tested in both a lab setting, and a subset was deployed in residential homes for longer term data collection during real-world use.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effectiveness of leading-edge vortex flaps on 60 and 75 degree delta wings

A series of wind tunnel tests were run on 60 and 75 deg sweep delta wings to examine the effectiveness of leading-edge vortex flaps. Tests results showed that leading-edge vortex flaps are effective in giving large increases in lift-to-drag ratio and decreases in drag over a wide range of angle of attack. Tests on inverted flaps on the 60 deg delta wing showed substantial increases in lift and drag and may indicate a possibility of using inverted flaps on delta wings in the landing portion of flight. The 60 deg data were compared with that for a 75 deg sweep delta wing confirming that leading-edge vortex flap effectiveness is stronger as sweep is increased. Pitching moment effects due to vortex flaps use were also examined.

Marchman, J. F., III↗

Asteroid Lightcurve Inversion

The application of convex profile inversion (CPI) to the interpretation of asteroid lightcurves is discussed. This technique investigates the problem of extracting information about an asteroid's shape from its lightcurve. Whenever four ideal conditions are met, P is an estimator for the asteroids mean cross section C, a convex set defined as the average of all cross sections C(Z) cut by planes a distance z above the asteroids equatorial plane. C is therefore a 2-D average of the asteroids 3-D shape. The method is tested by inverting lightcurves generated analytically for geometrically scattered ellipsoids (GSE's) with semiaxes a or = B or = C. Using a defined 'distance measure' to quantify the difference between any two profiles, the deviation of P from C for GSE's as a function of lightcurve noise level, rotation phase sampling interval delta theta, and departure from ideal conditions is calibrated. The distance between P and a circle provides a gauge of the asteroid's nonsphericity and incorporates all the information contained in the lightcurve.

Ostrow, S. J.↗

Inverting Image Data For Optical Testing And Alignment

Data from images produced by slightly incorrectly figured concave primary mirror in telescope processed into estimate of spherical aberration of mirror, by use of algorithm finding nonlinear least-squares best fit between actual images and synthetic images produced by multiparameter mathematical model of telescope optical system. Estimated spherical aberration, in turn, converted into estimate of deviation of reflector surface from nominal precise shape. Algorithm devised as part of effort to determine error in surface figure of primary mirror of Hubble space telescope, so corrective lens designed. Modified versions of algorithm also used to find optical errors in other components of telescope or of other optical systems, for purposes of testing, alignment, and/or correction.

Shao, Michael↗

Inverter Matrix for the Clementine Mission

An inverter matrix test circuit was designed for the Clementine space mission and is built into the RRELAX (Radiation and Reliability Assurance Experiment). The objective is to develop a circuit that will allow the evaluation of the CMOS FETs using a lean data set in the noisy spacecraft environment.

CMOS FETs spacecraft environment RRELAX orbit moon↗

Adaptive Voltage Control with Distributed Energy Resources: Algorithm, Theoretical Analysis, Simulation and Field Test Verification

Abstract Distributed energy resources (DE) or distributed generators (DG) with power electronics interfaces and logic control using local measurements are capable of providing reactive power related ancillary system services. In particular, local voltage regulation has drawn much attention in regards to power system reliability and voltage stability, especially from past major cascading outages. This paper addresses the challenges of controlling DEs to regulate local voltage in distribution systems. An adaptive voltage control method has been proposed to dynamically modify control parameters to respond to system changes. Theoretical analysis shows that there exists a corresponding formulation of the dynamic control parameters; hence the adaptive control method is theoretically solid. Both simulation and field experiment test results at the Distributed Energy Communications and Controls (DECC) Laboratory confirm that this method is capable of satisfying the fast response requirement for operational use without causing oscillation, inefficiency, or system equipment interference. Since this method has a high tolerance to real-time data shortage and is widely adaptive to variable power system operational situations, it is quite suitable for broad utility application.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comprehensive Efficiency Analysis of Current Source Inverter Based on CSI-Type Double Pulse Test and Genetic Algorithm

A current-source inverter (CSI) has a natural output voltage boost feature that can be advantageous for traction applications. Switching frequency is one of the easily-controlled variables that can be adjusted to improve the CSI efficiency at different operating points when the boost function is used. This paper investigates a CSI-based double-pulse test (DPT) measurement that mimics normal operation of the CSI. A loss model of the CSI is developed based on the CSI-type DPT experimental results. The impacts of the switching frequency and voltage boost ratio on the CSI efficiency and output voltage ripple are investigated. Based on the loss model, a genetic algorithm has been introduced that makes it possible to optimize the CSI's switching frequency and modulation index to maximize its efficiency under any desired operating condition.

current-source inverter, genetic algorithm, SPM ma↗

PHIL Interface Design for Use With a Voltage-Regulated Amplifier

Power hardware-in-the-loop (PHIL) has emerged as a leading strategy to thoroughly assess the impact of proprietary inverter controls on a specific power system. The development of a PHIL test bed typically involves an inverter under test, a power amplifier, controllable DC supply, and a digital real-time simulator (DRTS) to simulate the power system under study. As a result of PHIL nonidealities, a form of digital compensation within the DRTS is used, which is commonly referred to as a PHIL interface. Many existing methods use legacy power amplifiers that do not contain internal voltage regulation. These existing interface methods are based around a voltage regulator within the DRTS and do not consider the interaction with the controls in newer amplifiers. In this study, a three-step approach of PHIL interface development for modern power amplifiers with built-in voltage regulation is introduced and is validated in hardware with a 30-kW grid-following inverter.

DRTS↗