Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Measurement of Electron Density near Plasma Grid of Large-scaled Negative Ion Source by Means of Millimeter-Wave Interferometer

A millimeter-wave interferometer with the frequency of 39 GHz ({lambda} 7.7 mm) was newly installed to a large-scaled negative ion source. The measurable line-integrated electron density (n{sub e}l) is from 2x10{sup 16} to 7x10{sup 18} m{sup -2}, where n{sub e} and l represent an electron density and the plasma length along the millimeter-wave path, respectively. Our interest in this study is behavior of negative ions and reduction of electron density in the beam extraction region near the plasma grid. The first results show the possibility of the electron density measurement by the millimeter-wave interferometer in this region. The line-averaged electron density increases proportional to the arc power under the condition without cesium seeding. The significant decrease of the electron density and significant increase of the negative ion density were observed just after the cesium seeding. The electron density measured with the interferometer agrees well with that observed with a Langmuir probe. The very high negative ion ratio of n{sub H-}/(n{sub e}+n{sub H-}) = 0.85 was achieved within 400 min. after the cesium seeding.

43 PARTICLE ACCELERATORS↗

A combined phase contrast imaging and heterodyne interferometer system for multiscale fluctuation measurements (invited)

In this work, a novel combined diagnostic capable of measuring multiscale density fluctuations that extend from magnetohydrodynamic (MHD) to the lower range of electron temperature gradient turbulence has been designed, installed, and operated at DIII-D. The combined diagnostic was constructed by adding a heterodyne interferometer to the pre-existing phase contrast imaging (PCI) system, both of which measure line-integrated electron density fluctuations. The port-space footprint is minimized via use of a single 10.6 μm probe beam. With temporal bandwidths in excess of 1 MHz, the PCI measures high-k (1.5 cm -1 < |k R | ≤ 25 cm -1 ) fluctuations with sensitivity 3×10 13 m -2 /$\sqrt{kHz}$, while the interferometer simultaneously measures low-k (|k R | < 5 cm -1 ) fluctuations with sensitivity 3×10 14 m -2 /$\sqrt{kHz}$. The intentional mid-k overlap has been empirically verified with sound-wave calibrations and allows quantitative investigation of multiscale effects that are predicted to be significant in the reactor-relevant T e ~ T i regime. Lastly, via correlation with the primary DIII-D interferometer, the toroidal mode numbers of core-localized MHD can be measured.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Angular alignment and fidelity of neutron phase-gratings for improved interferometer fringe visibility

The recent development of phase-grating moiré neutron interferometry promises a wide range of impactful experiments from dark-field imaging of material microstructure to precise measurements of fundamental constants. However, the contrast of 3% obtained using this moiré interferometer was well below the theoretical prediction of 30% using ideal gratings. It is suspected that non-ideal aspects of the phase-gratings was a leading contributor to this deficiency and that phase-gratings needed to be quantitatively assessed and optimized. Here we characterize neutron diffraction from phase-gratings using Bragg diffraction crystals to determine the optimal phase-grating orientations. We show well-defined diffraction peaks and explore perturbations to the diffraction peaks and the effects on interferometer contrast as a function of grating alignment. This technique promises to improve the contrast of the grating interferometers by providing in-situ aides to grating alignment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Correlation polarimeter-interferometer in the DIII-D tokamak

A correlation polarimeter-interferometer system has been developed for the DIII-D tokamak to detect small amplitude magnetic and density fluctuations. Two collinear, frequency-offset (5–15 MHz), orthogonally polarized (right- and left-handed, circularly polarized) electromagnetic waves at 650 GHz probing the plasma are used to detect the Faraday effect. A third, linearly polarized, electromagnetic wave serves as the local-oscillator to provide a measure of the line-averaged density. Correlation polarimetric measurement is accomplished by correlating the Faraday effect measured along the same line of sight using two independent detectors, whereas simultaneous correlation interferometric measurement is realized by correlating the line-averaged density measured at two different intermediate frequencies. The noise floor of the correlation polarimeter-interferometer has been demonstrated to be more than one order of magnitude lower than that of a standard polarimeter-interferometer measurement. Line-averaged correlation polarimetric-interferometric measurements in DIII-D H-mode plasmas show broadband (up to 750 kHz) magnetic and density fluctuations with amplitudes as low as 0.03 $Gauss$/$\sqrt{kHz}$ and 4 × 10 13 m –3 /$\sqrt{kHz}$, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dual-axis high-data-rate atom interferometer via cold ensemble exchange

We demonstrate a dual-axis accelerometer and gyroscope atom interferometer, which can form the building blocks of a six-axis inertial measurement unit. By recapturing the atoms after the interferometer sequence, we maintain a large atom number at high data rates of 50 to 100 measurements per second. Two cold ensembles are formed in trap zones located a few centimeters apart and are launched toward one another. During their ballistic trajectory, they are interrogated with a stimulated Raman sequence, detected, and recaptured in the opposing trap zone. As a result, we achieve sensitivities at μg/ √Hz and μrad/s/ √Hz levels, making this a compelling prospect for expanding the use of atom interferometer inertial sensors beyond benign laboratory environments.

47 OTHER INSTRUMENTATION↗

Robust Quantum Control via Multipath Interference for Thousandfold Phase Amplification in a Resonant Atom Interferometer

We introduce a novel technique for enhancing the robustness of light-pulse atom interferometers against the pulse infidelities that typically limit their sensitivities. The technique uses quantum optimal control to favorably harness the multipath interference of the stray trajectories produced by imperfect atom-optics operations. We apply this method to a resonant atom interferometer and achieve thousandfold phase amplification, representing a 50-fold improvement over the performance observed without optimized control. Moreover, we find that spurious interference can arise from the interplay of spontaneous emission and many-pulse sequences and demonstrate optimization strategies to mitigate this effect. Given the ubiquity of spontaneous emission in quantum systems, these results may be valuable for improving the performance of a diverse array of quantum sensors. We anticipate our findings will significantly benefit the performance of matter-wave interferometers for a variety of applications, including dark matter, dark energy, and gravitational wave detection.

47 OTHER INSTRUMENTATION↗

Measurement and alleviation of subsurface damage in a thick-crystal neutron interferometer

The construction is described of a monolithic thick-crystal perfect silicon neutron interferometer using an ultra-high-precision grinding technique and a combination of annealing and chemical etching that differs from the construction of prior neutron interferometers. The interferometer is the second to have been annealed after machining and the first to be annealed prior to chemical etching. Monitoring the interference signal at each post-fabrication step provides a measurement of subsurface damage and its alleviation. In this case, the strain caused by subsurface damage manifests itself as a spatially varying angular misalignment between the two relevant volumes of the crystal and is reduced from ~10 -5 rad to ~10 -9 rad by way of annealing and chemical etching.

Chemistry↗

Machine Straightness Error Measurement Based on Optical Fiber Fabry–Pérot Interferometer Monitoring Technique

Abstract In this research, we propose an Error Separation Technique (EST) based on optical fiber sensors for on-machine straightness error measurement. Two fiber optic Fabry–Pérot interferometers have been developed serving as two displacement sensors. The displacement distance is computed according to the reflected spectrum from interferometers, which can achieve a sub-micrometer resolution. The two-point method has been employed to separate the straightness error of the slides and the profile error of a fine-polished standard block. The spacing distance between two interferometers is determined by the diameter of optical fibers so that the EST's resolution has the potential to reach the sub-millimeter scale. In the experiment, the straightness error has been measured on a commercially available computer numerical control machine tool, and the measurement has been conducted on its x-axis. The spacing distance between two optical fiber sensors is 1.5 mm which equals the EST's resolution along the machine tool's x-axis. The separated profile error of the measured standard block is around 30 µm which has been verified by a high precision Coordinate Measurement Machine (CMM). The magnitude of the separated straightness error is around 40 µm. This technique is flexible and simple to be conducted, which can contribute to the micro-machine tool calibration and other straightness error applications.

Engineering↗

Spectrograph stabilization using a single-delay interferometer on the Hale Telescope

We describe a technique for spectrograph stabilization useful when conventional mitigation techniques of vacuum tanks, thermal insulation, and laser frequency comb may be impractical, expensive, heavy, or bulky. This includes spectrographs on airborne platforms or mounted on telescopes where they suffer a changing gravity vector or other drifts. Placing a fixed-delay interferometer in series with a spectrograph forms an externally dispersed interferometer (EDI). This produces a uniform sinusoidal comb multiplying input spectrum, creating (through heterodyning) beats (moiré patterns). In Fourier space for low frequencies up to the comb frequency, the moiré generated signal counter-rotates to ordinary spectra under an unknown disperser wavenumber drift Δx. This generates a large negative feedback signal useful in a conceptual control loop, to converge rapidly to a stable spectrum and yield Δx. A modified EDI data analysis algorithm (“crossfading”) combines frequency-weighted moiré with conventional spectrum to cancel net output spectrum reaction to Δx. Needing only a single-delay, this is a practical improvement over prior crossfading analyses requiring multiple delays. We test crossfading on ThAr data near 4850 cm−1 taken on Hale telescope in an earlier project. In a single pass, we reduce drift 20 times. Using seven iterations, we reduce 0.5 cm−1 (31 km/s Doppler equivalent) drift to 4×10−7 cm−1 (2.5 cm/s). The interferometer delay can wander, because linearity of phase versus wavenumber interpolates science features between bracketing calibrating spectral references. Second, mathematically reversing the heterodyning effect doubles effective spectral resolution without changing disperser slit.

Erskine, David J [Lawrence Livermore National Labo↗

Characterization and operation optimization of large aperture optical interferometers using binary pseudorandom array test standards

Recently, a technique for calibration of the Modulation Transfer Function (MTF) of a broad variety of metrology instrumentation has been established. The technique is based on test samples structured according to binary pseudorandom (BPR) one-dimensional sequences and two-dimensional arrays. The inherent power spectral density of BPR gratings and arrays, has a deterministic white-noise-like character that allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. As such, the BPR samples satisfy the characteristics of a test standard: Functionality, ease of specification and fabrication, reproducibility, and low sensitivity to manufacturing error. Here we discuss our recent developments working with support of the U.S. Department of Energy on industrialization of the technique. The goal is to develop affordable BPR test samples, application procedures, and data processing software, suitable for thorough characterization of optical interferometers and microscopes, as well as x-ray, electron (scanning and transmission), and atomic force microscopes. We report on the development of BPR array test samples optimized for advanced characterization (including the instrumental MTF and aberrations) and operation optimization of large aperture optical interferometers. We describe the sample fabrication process and tests to verify the compliance to desired surface topography. The data acquisition and analysis procedures for application of the technique for precise focusing of Fizeau interferometer are discussed in detail.

Yashchuk, VV↗

Performance of plane wavefront Fizeau interferometers in power spectral density measurements with tilted plane optics

Binary pseudo-random array (BPRA) test samples are useful devices for calibrating the instrument transfer function (ITF) of Fizeau interferometers, interferometric microscopes, and other optical and non-optical surface and wavefront metrology instruments. The intrinsic white noise character of the power spectral density (PSD) function of the BPRA pattern simplifies the extraction of the ITF from the measured PSD. The ITF determined in a dedicated calibration experiment can be used to reconstruct the surface height profile from the measured data, effectively enhancing the instrument’s spatial resolution. For a high confidence reconstruction procedure, a reliable analytical model of the IFT is desirable. Usually, the model accounts for the contributions to the ITF related the imperfections of the instrument’s optical and detector systems. Here, we experimentally demonstrate that in the case of surface height metrology with Fizeau interferometers, the PSD measurements and, therefore, the efficacy of the ITF calibration of the tool, are strongly affected by the instrument data acquisition and processing procedures, as well as by the shape of the optic under test and its alignment with respect to the interferometer.

Yashchuk, V V↗

Using the Talbot_Lau_interferometer_parameters Spreadsheet

Talbot-Lau interferometers allow incoherent X-ray sources to be used for phase contrast imaging. A spreadsheet for exploring the parameter space of Talbot and Talbot-Lau interferometers has been assembled. This spreadsheet allows the user to examine the consequences of choosing phase grating pitch, source energy, and source location on the overall geometry of a Talbot or Talbot-Lau X-ray interferometer. For the X-ray energies required to penetrate scanned luggage the spacing between gratings is large enough that the mechanical tolerances for amplitude grating positioning are unlikely to be met.

42 ENGINEERING↗

Holographic Noise in Interferometers

General arguments based on black hole evaporation, and on particular interpretations of holographic unification, suggest that there may be a new kind of indeterminacy in the relative transverse position of bodies in spacetime, corresponding to the diffraction limit of Planck wavelength radiation. Suitably designed instruments should display a new phenomenon, resembling a randomly varying shear in relative transverse position away from classical geodesics, with a flat power spectral density at low frequencies given approximately by the Planck time, and with no other parameters. An effective theory is presented to connect holographic unification with macroscopic phenomena, such as the statistical properties of noise in signals of interferometers. Macroscopic position operators in Matrix theory are interpreted to obey a Schr\'odinger wave equation, or equivalently a paraxial wave equation with a Planck frequency carrier, that connects longitudinal and transverse modes. A model based on gaussian-beam solutions of this equation is used to derive formulas in the time and frequency domain for autocorrelation of beamsplitter position in a Michelson interferometer. The cross-correlation of signals in two non-coincident interferometers as a function of separation is estimated. The cross-correlation signature may be exploited in the design of experiments to provide convincing evidence for or against the holographic hypothesis.

Hogan, Craig J.↗

Graphene-Based Quantum Hall Interferometer with Self-Aligned Side Gates

The vanishing band gap of graphene has long presented challenges for fabricating high-quality quantum point contacts (QPCs)–the partially transparent p-n interfaces introduced by conventional split-gates tend to short the QPC. This complication has hindered the fabrication of graphene quantum Hall Fabry-P'erot interferometers, until recent advances have allowed split-gate QPCs to operate utilizing the highly resistive ν = 0 state. Here, we present a simple recipe to fabricate QPCs by etching a narrow trench in the graphene sheet to separate the conducting channel from self-aligned graphene side gates. Finally, we demonstrate operation of the individual QPCs in the quantum Hall regime, and further utilize these QPCs to create and study a quantum Hall interferometer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Parametric oscillatory instability in a signal-recycled LIGO interferometer

The undesirable effect of parametric oscillatory instability in a LIGO (Laser Interferometer Gravitational-Wave Observatory) laser gravitational-wave antenna with a signal-recirculation mirror is analysed in detail. The instability is manifested in excitation of the Stokes optical mode and elastic mechanical mode of the mirror. It is shown that, if the eigenfrequencies of Fabry-Perot resonators in the interferometer arms are different, the parametric instability is quite small due to a small passband band width. (fifth seminar in memory of d.n. klyshko)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Device for enhancing the time contrast of utrashort laser pulses based on a polarisation Mach-Zehnder interferometer

A polarisation Mach-Zehnder interferometer is considered containing identical cells with a nonlinear medium in different arms. A parallel wave beam propagates through one cell and a converging-diverging wave beam propagates through the other. It is shown that the interferometer transmission depends on the power of the laser pulse propagated through it. It is proposed to use this effect to enhance the time contrast of ultrashort and superhigh-power laser pulses, i.e. to suppress side (background) pulses. (control of laser radiation parameters)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Properties of an ultrafast all-optical switching window in an integrated silicon-based Mach - Zehnder interferometer

An ultrafast all-optical switch based on the integrated Mach - Zehnder interferometer (MZI) with two arms consisting of identical silicon-on-insulator (SOI) optical waveguides is presented. The operability of the presented interferometer is simulated both for the continue wave (cw) and pulsed probe signals. It is shown that at the output port of the MZI, the switching window of the probe signal is strongly dependent on the energy and duration of the ultrafast control pulse and the SOI waveguide length. In addition, the initial delay time between both two optical waves will significantly affect the optical switching window when a pulsed probe signal wave is used. (integrated optics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase estimation with nonunitary interferometers: Information as a metric

Determining the phase in one arm of a quantum interferometer is discussed taking into account the three nonideal aspects in real experiments: nondeterministic state preparation, nonunitary state evolution due to losses during state propagation, and imperfect state detection. A general expression is written for the probability of a measurement outcome taking into account these three nonideal aspects. As an example of applying the formalism, the classical Fisher information and fidelity (Shannon mutual information between phase and measurements) are computed for few-photon Fock and N00N states input into a lossy Mach-Zehnder interferometer. These three nonideal aspects lead to qualitative differences in phase estimation, such as a decrease in fidelity and Fisher information that depends on the true value of the phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗