Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Orbiting Stellar Interferometer: An Overview

The Orbiting Stellar Interferometer (OSI) is a concept for a first-generation space interferometer with astrometric and imaging capabilities and is responsive to the recommendations of the Astronomy and Astrophysics Survey Committee for an astrometric interferometry mission. OSI is a triple Michelson interferometer with articulating siderostats and optical delay lines. The design uses a 7m maximum baseline and aperture diameters of 33 cm; the targeted astrometric performance is a wide-field accuracy of 5µas for 20-mag objects. The instrument would also be capable of synthesis imaging with a resolution of 10mas. Laser metrology is used to relax structural requirements thereby reducing cost. The currently envisaged flight system fits into an Atlas II shroud, for insertion into a 900 km sun-synchronous orbit.

['OSI↗

Non-reciprocal Interferometers for Matter Waves

We propose non-reciprocal interferometers for matter waves and explore them by means of modeling. These interferometers may be implemented as asymmetric quantum rings with broken time-inversion symmetry. Our preliminary analyses lead us to predict that these devices will feature asymmetric transport properties for particles such as electrons, for which the interferometers’ ground states act as directional filters. As a function of the electron velocity, the filters seem to let electrons preferentially pass in one direction rather than in the reverse, thereby reducing the entropy of the electron systems in the contacts. Mechanisms are discussed that are candidates to prevent directional filtering if the filters are operating in thermal equilibrium with incoherent electron reservoirs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray grating interferometer for materials-science imaging at a low-coherent wiggler source

X-ray phase-contrast radiography and tomography enable to increase contrast for weakly absorbing materials. Recently, x-ray grating interferometers were developed that extend the possibility of phase-contrast imaging from highly brilliant radiation sources like third-generation synchrotron sources to non-coherent conventional x-ray tube sources. Here, we present the first installation of a three grating x-ray interferometer at a low-coherence wiggler source at the beamline W2 (HARWI II) operated by the Helmholtz-Zentrum Geesthacht at the second-generation synchrotron storage ring DORIS (DESY, Hamburg, Germany). Using this type of the wiggler insertion device with a millimeter-sized source allows monochromatic phase-contrast imaging of centimeter sized objects with high photon flux. Thus, biological and materials-science imaging applications can highly profit from this imaging modality. The specially designed grating interferometer currently works in the photon energy range from 22 to 30 keV, and the range will be increased by using adapted x-ray optical gratings. Our results of an energy-dependent visibility measurement in comparison to corresponding simulations demonstrate the performance of the new setup.

43 PARTICLE ACCELERATORS↗

First results from the J-TEXT high-resolution three-wave polarimeter-interferometer

A laser-based far-infrared polarimeter-interferometer system utilizing the three-wave technique has been implemented on the J-TEXT tokamak. The polarimeter determines the Faraday effect by measuring the phase difference between two collinear, counter-rotating, circularly polarized laser beams. The first results of the polarimeter-interferometer designed for J-TEXT have been obtained in the most recent J-TEXT experimental campaign. Simultaneous polarimetric and interferometric measurement is achieved, with phase resolution up to 0.1 Degree-Sign , at bandwidth of 50 kHz. The temporal resolution, which is dependent on the laser's frequency offset, is {approx}1 {mu}s. Continual spatial measurement covering 45 cm (80% of the plasma cross-section) is realized by utilizing 1D parabolic beam expansion optics. Three initial test chords are installed and future plans call for expansion up to 30 chords with 1.5 cm chord spacing, providing high spatial resolution for measurement of electron density and current density profiles. Reliability of both polarimetric and interferometric measurement is confirmed by comparison with computation and data from a hydrocyanic acid (HCN) interferometer. With the high temporal and phase resolution, perturbations associated with the sawtooth cycle and MHD activity have been observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-line Mach-Zehnder interferometer composed of microtaper and long-period grating in all-solid photonic bandgap fiber

We report a compact in-line Mach-Zehnder interferometer combining a microtaper with a long-period grating (LPG) in a section of all-solid photonic bandgap fiber. Theoretical and experimental investigations reveal that the interferometer works from the interference between the fundamental core mode and the LP{sub 01} cladding supermodes. The mechanism underlying the mode coupling caused by the microtaper can be attributed to a bandgap-shifting as the fiber diameter is abruptly scaled down. In addition, the interferometer designed to strengthen the coupling ratio of the long-period grating has a promising practical application in the simultaneous measurement of curvature and temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An electron Talbot-Lau interferometer and magnetic field sensing

We present a demonstration of a three grating Talbot-Lau interferometer for electrons. As a proof of principle, the interferometer is used to measure magnetic fields. The device is similar to the classical Moiré deflectometer. The possibility to extend this work to build a scaled-up electron deflectometer or interferometer for sensitive magnetic field sensing is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement method for roll angular displacement with a high resolution by using diffraction gratings and a heterodyne interferometer

The roll angle measurement is difficult to be achieved directly using a typical commercial interferometer due to its low sensitivity in axial direction, where the axial direction is orthogonal to the plane of the roll angular displacement. A roll angle measurement method combined diffraction gratings with a laser heterodyne interferometer is discussed in this paper. The diffraction grating placed in the plane of a roll angular displacement and the interferometer arranged in the plane's orthogonal direction, constitute the measurement pattern for the roll angle with high resolution. The roll angular displacement, considered as the linear, can be tested precisely when the corresponding angle is very small. Using the proposed method, the angle roll measurement obtains the high resolution of 0.002{sup ″}. Experiment has proved its feasibility and practicability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of interferometer system for Keda Torus eXperiment using terahertz solid-state diode sources

A solid-state source based terahertz (THz) interferometer diagnostic system has been designed and characterized for the Keda Torus eXperiment (KTX). The THz interferometer utilizes the planar diodes based frequency multiplier (X48) to provide the probing beam at fixed frequency 0.650 THz, and local oscillator is provided by an independent solid-state diode source with tunable frequency (0.650 THz +/− 10 MHz). Both solid-state sources have approximately 1 mW power. The planar-diode mixers optimized for high sensitivity, ∼750 mV/mW, are used in the heterodyne detection system, which permits multichannel interferometer on KTX with a low phase noise. A sensitivity of {sub min} = 4.5 × 10{sup 16} m{sup −2} and a temporal resolution of 0.2 μs have been achieved during the initial bench test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid optical ring interferometer for high-throughput feedback-free spectral analysis and filtering

We describe a simple and inexpensive optical ring interferometer for use in high-resolution spectral analysis and filtering. It consists of a solid cuboid, reflection-coated on two opposite sides, in which constructive interference occurs for waves in a rhombic trajectory. Due to its monolithic design, the interferometer’s resonance frequencies are insensitive to environmental disturbances over time. Additional advantages are its simplicity of alignment, high-throughput, and feedback-free operation. If desired, it can be stabilized with a secondary laser without disturbance of the primary signal. We illustrate the use of the interferometer for the measurement of the spectral Mollow triplet from a quantum dot and characterize its long-term stability for filtering applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the transmission phase of an electron in a quantum two-path interferometer

A quantum two-path interferometer allows for direct measurement of the transmission phase shift of an electron, providing useful information on coherent scattering problems. In mesoscopic systems, however, the two-path interference is easily smeared by contributions from other paths, and this makes it difficult to observe the true transmission phase shift. To eliminate this problem, multi-terminal Aharonov-Bohm (AB) interferometers have been used to derive the phase shift by assuming that the relative phase shift of the electrons between the two paths is simply obtained when a smooth shift of the AB oscillations is observed. Nevertheless, the phase shifts using such a criterion have sometimes been inconsistent with theory. On the other hand, we have used an AB ring contacted to tunnel-coupled wires and acquired the phase shift consistent with theory when the two output currents through the coupled wires oscillate with well-defined anti-phase. Here, we investigate thoroughly these two criteria used to ensure a reliable phase measurement, the anti-phase relation of the two output currents, and the smooth phase shift in the AB oscillation. We confirm that the well-defined anti-phase relation ensures a correct phase measurement with a quantum two-path interference. In contrast, we find that even in a situation where the anti-phase relation is less well-defined, the smooth phase shift in the AB oscillation can still occur but does not give the correct transmission phase due to contributions from multiple paths. This indicates that the phase relation of the two output currents in our interferometer gives a good criterion for the measurement of the true transmission phase, while the smooth phase shift in the AB oscillation itself does not.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A closed-loop phase-locked interferometer for wide bandwidth position sensing

This article describes a position sensitive interferometer with closed-loop control of the reference mirror. A calibrated nanopositioner is used to lock the interferometer phase to the most sensitive point in the interferogram. In this configuration, large low-frequency movements of the sensor mirror can be detected from the control signal applied to the nanopositioner and high-frequency short-range signals can be measured directly from the photodiode. It is demonstrated that these two signals are complementary and can be summed to find the total displacement. The resulting interferometer has a number of desirable characteristics: it is optically simple, does not require polarization or modulation to detect the direction of motion, does not require fringe-counting or interpolation electronics, and has a bandwidth equal to that of the photodiode. Experimental results demonstrate the frequency response analysis of a high-speed positioning stage. The proposed instrument is ideal for measuring the frequency response of nanopositioners, electro-optical components, MEMs devices, ultrasonic devices, and sensors such as surface acoustic wave detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

30-lens interferometer for high energy x-rays

We report a hard X-ray multilens interferometer consisting of 30 parallel compound refractive lenses. Under coherent illumination each CRL creates a diffraction limited focal spot - secondary source. An overlapping of coherent beams from these sources resulting in the interference pattern which has a rich longitudinal structure in accordance with the Talbot imaging formalism. The proposed interferometer was experimentally tested at ID11 ESRF beamline for the photon energies 32 keV and 65 keV. The fundamental and fractional Talbot images were recorded with the high resolution CCD camera. An effective source size in the order of 15 µm was determined from the first Talbot image proving that the multilens interferometer can be used as a high resolution beam diagnostic tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high speed compact microwave interferometer for density fluctuation measurements in Sino-UNIted Spherical Tokamak

A single-channel 3 mm interferometer has been developed for plasma density diagnostics in the Sino-UNIted Spherical Tokamak (SUNIST). The extremely compact microwave interferometer utilizes one corrugated feed horn antenna for both emitting and receiving the microwave. The beam path lies on the equatorial plane so the system would not suffer from beam path deflection problems due to the symmetry of the cross section. A focusing lens group and an oblique vacuum window are carefully designed to boost the signal to noise ratio, which allows this system to show good performance even with the small-diameter central column itself as a reflector, without a concave mirror. The whole system discards the reference leg for maximum compactness, which is particularly suitable for the small-sized tokamak. An auto-correcting algorithm is developed to calculate the phase evolution, and the result displays good phase stability of the whole system. The intermediate frequency is adjustable and can reach its full potential of 2 MHz for best temporal resolution. Multiple measurements during ohmic discharges proved the interferometer’s capability to track typical density fluctuations in SUNIST, which enables this system to be utilized in the study of MHD activities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A phase contrast imaging–interferometer system for detection of multiscale electron density fluctuations on DIII-D

Heterodyne interferometry and phase contrast imaging (PCI) are robust, mature techniques for measuring low-k and high-k electron density fluctuations, respectively. This work describes the first-ever implementation of a combined PCI–interferometer. The combined system uses a single 10.6 μm probe beam, two interference schemes, and two detectors to measure electron density fluctuations at large spatiotemporal bandwidth (10 kHz <f < 5 MHz and 0 cm{sup -1} ≤k ≤ 20 cm{sup -1}), allowing simultaneous measurement of ion- and electron-scale instabilities. Further, correlating our interferometer’s measurements with those from DIII-D’s pre-existing, toroidally separated interferometer allows core-localized, low-n MHD studies that may otherwise be inaccessible via external magnetic measurements. The combined diagnostic’s small port requirements and minimal access restrictions make it well-suited to the harsh neutron environments and limited port space expected in next-step devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Six-channel adaptive fibre-optic interferometer

We have proposed and analysed a scheme for the multiplexing of orthogonal dynamic holograms in photorefractive crystals which ensures almost zero cross talk between the holographic channels upon phase demodulation. A six-channel adaptive fibre-optic interferometer was built, and the detection limit for small phase fluctuations in the channels of the interferometer was determined to be 2.1 Multiplication-Sign 10{sup -8} rad W{sup 1/2} Hz{sup -1/2}. The channel multiplexing capacity of the interferometer was estimated. The formation of 70 channels such that their optical fields completely overlap in the crystal reduces the relative detection limit in the working channel by just 10 %. We found conditions under which the maximum cross talk between the channels was within the intrinsic noise level in the channels (-47 dB).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Narrow-band fibre reflector based on a fibre Bragg grating reflection interferometer

Narrow-band filtering in reflected light using a reflection interferometer with a fibre Bragg grating (FBG) as its back mirror is demonstrated for the first time. The reflection interferometer is made in SMF-28e single-mode fibre, and the faces of its front mirror, which includes a thin metallic film, differ in reflectance. The reflection bandwidth of a test sample is 0.5 pm (62 MHz) at a wavelength of 1556 nm (Q-factor of 3 × 10{sup 6}), its maximum reflectance is 0.21, and its contrast is 10{sup 2}. The use of a narrow-band FBG instead of thin-film broadband mirrors allows spectral selection to be significantly improved owing to an increase in the length of the interferometer base. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Features of correlation measurements of the parameters of pulsed hyperspectral optical fields using an asymmetric interferometer

Differences in correlation measurements of the parameters of pulsed hyperspectral optical fields using symmetric and asymmetric interferometers are considered. It is shown analytically that the resulting cross-correlation function is sensitive to phase perturbations in the original wave field. The considered setup, which contains a telescopic reflective 4f system of parabolic mirrors in one arm, demonstrates that in the case of an asymmetric interferometer, the presence of aberrations leads to degradation of the reconstructed image, whereas in the case of symmetric interferometers these aberrations do not affect the result. (paper)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

WIDE-ANGLE, NARROW-ANGLE, AND IMAGING BASELINES OF OPTICAL LONG-BASELINE INTERFEROMETERS

For optical interferometers, the baseline is typically defined as the vector joining two perfectly identical telescopes. However, when the telescopes are naturally different or when the requirements on the baseline vector challenge the telescope perfection, the baseline definition depends on how the interferometer is used. This is where the notions of wide-angle, narrow-angle, and imaging baselines come into play. This article explores this variety of baselines, with the purpose of presenting a coherent set of definitions, describing how they relate to each other, and suggesting baseline metrology requirements. Ultimately, this work aims at supporting upcoming long-baseline optical interferometers with narrow-angle astrometry and phase-referenced imaging capabilities at the microarcsecond level.

79 ASTRONOMY AND ASTROPHYSICS↗