Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “initial performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A Novel High-Temperature Generator/Motor Design: With Applications in Geothermal Drilling and Other Industries

The National Renewable Energy Laboratory (NREL), in partnership with Tetra Corporation and TPL Inc, has an ongoing ARPA-E project related to an advanced high-temperature geothermal drilling system, and the power electronics necessary for this system. As part of this work, NREL designed, built and tested a high-temperature generator for power generation in a 250 degrees Celsius downhole drilling environment. This design exceeded initial performance targets at elevated temperature. NREL is investigating alternative applications for this design, as either a generator or motor capable of efficient performance at high temperature.

alternator↗

Performance of the Initial Implementation of the Shift Monte Carlo Code in SCALE 6.3

The Shift Monte Carlo code will be introduced in SCALE 6.3 as an alternative to the KENO V.a, KENO-VI, and Monaco codes. Calculations were performed to establish the performance of Shift for criticality safety analyses within the criticality safety analyses sequence (CSAS) based on models in the Verified, Archived Library of Inputs and Data (VALID). This test suite contains over 600 critical experiment models covering a broad range of fissile materials and neutron energy spectra. The comparisons presented include calculated k eff values and runtime performance for serial calculations and a selection of parallel calculations. Comparisons are presented for multigroup (MG) and continuous-energy (CE) calculations for KENO V.a and KENO-VI models. Results generated with a beta version of SCALE 6.3 indicate excellent agreement in k eff values between KENO and Shift. The largest differences in the average k eff value calculated for the 15 categories of KENO V.a models are 0.00020 ± 0.00011 Δ k for MG calculations and 0.00011 ± 0.00005 Δ k for CE calculations. Similar comparisons in three categories using KENO-VI result in the largest differences for MG calculations: as 0.00004 ± 0.00003 Δ k , and -0.00002 ± 0.00003 Δ k for CE. The preliminary results also indicate that Shift is faster than KENO on a per particle basis, especially for fast spectrum systems. The uncertainty per history is also higher, however, so the Monte Carlo figure of merit is higher for KENO for thermal and intermediate spectrum systems. As expected, Shift generally has better speedup than KENO for parallel calculations, regardless of neutron energy spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of Initial Structure on Performance of High-Entropy Oxide Anodes for Li-Ion Batteries

Two different high-entropy oxide materials were synthesized and studied as Li-ion battery anodes. The two materials have the same active metal constituents but different inactive elements which result in different initial crystalline structures: rock salt for (MgFeCoNiZn)O and spinel for (TiFeCoNiZn)3O4. Local structural studies of the metal elements in these two materials over extended electrochemical cycling reveal that the redox processes responsible for the electrode capacity are independent of the initial crystallographic structure and that the capacity is solely dependent on the initial random distribution of the metal atoms and the amount of active metals in the starting material.

25 ENERGY STORAGE↗

LAMP-PSR Scoping Studies Report

This report summarizes work performed from July – September 2023, performing an initial evaluation for the LANSCE Proton Storage Ring upgrade option “B.” The studies identified potential pathsforward, performing initial beam dynamics studies, and surveying various technology options different aspects of the upgrade. Taken together, the studies provide an “early look” at the feasibility, challenges and alternative methods for pursuing Option “B,” and give guidance towards more detailed design concept development needed as work progresses. Generally speaking, no major obstacles were identified in pursuing the Option “B” PSR upgrade path in terms of the machine physics or overall system architecture. Several areas of concern have been identified; we note that these primarily center on technology choice and must be addressed regardless of the upgrade path selected, and none of the concerns are considered insurmountable.

43 PARTICLE ACCELERATORS↗

Optimization of metal-supported solid oxide electrolysis cells with infiltrated catalysts

We report metal-supported solid oxide electrolysis cells (MS-SOECs) are being developed for steam-to-hydrogen electrolysis, especially for utilization of dynamic or intermittent electrical power from renewable sources. Various aspects of the electrocatalyst processing and composition, and metal support structure were explored. Catalyst materials, infiltration temperature and infiltration cycles were optimized for high performance and durability. Numerous catalyst materials were screened for both oxygen and steam electrodes. The oxygen catalyst had moderate impact on both initial cell performance and durability. Reducing Ni content in the steam electrode had little effect on durability, but reduced initial performance. Ex-situ XRD analysis and cell assessment of catalyst infiltration temperature revealed that the optimal range is 750–850 °C. The best cell performance and durability was achieved with LSCF-SDC oxygen electrocatalyst and SDC-Ni (60:40 vol%) steam electrocatalyst infiltrated 11 times at 800 °C and operated at 700 °C. At low steam content, a significant mass transport limitation on the steam side results in limiting current behavior. Thinner and more porous metal supports were implemented, and found to improve steam mass transport at low steam content, relevant for SOECs operating under high H 2 recycle rate or high steam utilization.

08 HYDROGEN↗

Industry-Average Performance for Components and Initiating Events at U.S. Commercial Nuclear Power Plants: 2020 Update

This report documents the quantitative results of the current industry-average performance for components and initiating events (IEs) at U.S. commercial nuclear power plants (NPPs). It represents the third update of the original analysis in NUREG/CR-6928 with data through 2020. Continuous characterization and updating of current industry-average performance with the latest industry data available are important steps in maintaining up-to-date risk models. Typically, data from 1998–2002 were used in NUREG/CR-6928, data from 1998–2010 in the first update, data from 1998–2015 in the second update, and data from 2006–2020 in this update, although many IEs required longer periods for adequate characterization of frequencies in all these analyses. As with NUREG/CR-6928 and previous updates, four types of events are covered in this report: component unreliability (e.g., a pump that fails to start or fails to run), component or train unavailability resulting from test or maintenance outages, special event probabilities covering operational issues (e.g., pump restarts and injection valve re-openings during unplanned demands), and IE frequencies. Results (in the form of beta distributions for failure probabilities upon demand and gamma distributions for rates) are used as inputs to the U.S. Nuclear Regulatory Commission standardized plant analysis risk models covering U.S. commercial NPPs.

99 GENERAL AND MISCELLANEOUS↗

A Smart Alarm for the CEBAF Injector

We present initial results from a proof-of-concept ?smart alarm? for the CEBAF injector. Because of the injector's large number of parameters and possible fault scenarios, it is highly desirable to have an autonomous alarm system that can quickly identify and diagnose unusual machine states. Our approach leverages a trained neural network to not only identify an anomalous machine state, but also to identify the root-cause by pinpointing the specific element or region responsible. We developed an inverse model trained on data collected during normal operations. Using the inverse model, measurements from the machine are used to compute machine settings, which are then compared to EPICS setpoints. Instances when predictions differ from EPICS setpoints by a user-defined threshold are flagged as anomalies, and the user is alerted to the issue. We present the results of our data collection efforts, model training and performance, and initial performance metrics.

Tennant, C.↗

Preliminary Design of Reactor Cavity Cooling System for a Horizontal Compact HTGR

The Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed MIGHTR in 3 years and support its commercialization as a safe and low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. This report documents the preliminary design study of the RCCS for the HC-HTGR. It includes the establishment of the design requirements, a high-level design study by initial scoping calculations, and preliminary performance calculations of the HC-HTGR RCCS design. Design requirements for the HC-HTGR RCCS have been established to guide preliminary design activities and scoping performance calculations. Initial scoping calculations including estimation of the water inventory, estimation of HVAC thermal capability, and a parametric study on loop dimensions by standalone RCCS analysis. Based on scoping calculation results, a set of baseline dimensions of the HC-HTGR RCCS was derived. A water panel modeling approach was investigated to explore various potential design options for the water panel under consideration for the HC-HTGR RCCS using RELAP5-3D. A test case study was performed to assess the prediction capability of two modeling approaches. The results were compared with CFD simulations conducted in constant RPV temperature and heat flux boundary conditions. It confirms the capability of the RELAP5-3D modeling approach to include all important heat transfer mechanisms expected in the HC-HTGR RCCS operation conditions. Then, a reference RELAP5-3D model for the 1/8 th of a compartment of the preliminary design of the HC-HTGR RCCS was developed. A preliminary performance analysis was conducted to evaluate single-phase natural circulation performance with different top tank temperature values and panel conduction performance in various operation conditions. From single-phase natural circulation performance analysis, the system operation mode was investigated in normal operating and limiting design conditions. It showed operation mode in a subcooled state with a proper top tank water cooling system. Parasitic heat loss by both internal air flow and RCCS was estimated, showing it satisfies maintaining below target maximum heat loss of the HC-HTGR RCCS. From the panel conduction performance analysis, two candidate materials for the riser tube such as carbon steel and stainless steel were compared in the thermal performance of HC-HTGR RCCS. From a single water panel test compared with CFD simulation results, it was confirmed that the current capability of the RELAP5-3D modeling approach for the water panel predicts the thermal conduction of two different materials of the water panel. Then, system-level thermal performance analysis was performed for 1/8 th of the compartment of the preliminary HC-HTGR RCCS design. It was first observed that the current preliminary HC-HTGR RCCS design had minimal impact on the overall thermal performance of the water panel by changing pipe material from carbon steel to stainless steel. From Argonne’s effort on the ongoing water-based NSTF testing program, several considerations other than the thermal performance point of view were addressed to be considered in selecting pipe materials.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Liquid Interfacial Electron Microscopy Identifies Nanogalvanic Corrosion in Pearlitic Steel

The nanoscale mechanisms of localized corrosion in low carbon steels have remained elusive due to the complexity of studying the degradative material behavior at nanoscale solid-liquid interfaces. We identified various steps in the nanogalvanic corrosion processes using in-situ liquid-cell scanning transmission electron microscopy (STEM) using a microfluidic holder by Hummingbird Scientific. Initial work, performed at low magnification, identified the initiation point on a 1018 low-carbon steel surface. This initiation point was determined to be a triple junction of two ferrite grains bridging a cementite grain in contact with a baseline electrolyte of 6 uM CO2 dissolved in a buffered (2.78 uM Na2SO4) aqueous solution, pH 6.1. The pre-etched low-carbon steel surface was prepared using focused ion beam lift-out procedures to extract a cross-section of the low-carbon steel surface, which then was thinned to about 150 nm and transferred to a SiN membrane microfluidic window. The transfer was made using a lift-out needle to attach the low-carbon steel lamella to the corner of the SiN window, and then Pt/C deposition held the lamella in contact with the window while it was released from the lift out needle. To identify the triple point on the low carbon steel lamella, prior to attachment on the SiN window, the sample was characterized for compositional variations with energy dispersive x-ray spectroscopy mapping, grain orientation and phase mapping with precession electron diffraction, and thickness mapping with energy filtered transmission electron microscopy. This pre-characterization prior to the in-situ experiment provided a map of the multiphase and multigrain structure, where the in-situ liquid cell imaging provided a clear understanding of the initiation point on the sample. These data were cross-correlated to paint a holistic picture of the triple junction site, enabling low electron-fluence in-situ snapshot imaging to avoid dominating the native corrosion reactions with effects from the incident electron beam. This initial result identified that localized, nanogalvanic corrosion at the phase interface was the dominant corrosion process in the low-carbon steel, so we next targeted the observation of an array of these nanogalvanic features phase boundaries in a pearlite grain. Near-surface ferrite/cementite phase interfaces that typify pearlitic low-carbon steel were extracted, pre-characterized, and imaged for the in-situ corrosion processes. The sample was a cross-section from a pearlite grain, with alternating ferrite and cementite grains that extended microns down from the pre-etched low-carbon steel pipe surface. After contact with a buffered aqueous solution, the phase boundaries between the ferrite and cementite began to dissolve, with observable material loss and thickness changes in the dark-field and bright-field STEM images. Within minutes, the corrosion front proceeded deeper into the material, claiming a thin layer of ferrite around all exposed phase boundaries before progressing laterally into the ferrite matrix, converting the ferrite to corrosion product normal to each buried cementite grain. Formation of the corrosion product causes a volumetric expansion, creating a lateral wedging force that mechanically ejects the cementite grains from their grooves and leaves behind percolation channels into the steel substructure. Rapid and deleterious, this nanogalvanic corrosion pathway represents an important target for understanding and preventing run-away degradation in this common building material. Observation of this corrosion mechanism was enabled by the combination of pre-characterization using standard structural, grain, and compositional analysis in the TEM, which provides maps for understanding the reaction propagation captured in low-dose, in-situ, liquid-cell STEM.

corrosion↗

Initial Benchmarks of UV LEDs and Comparisons with White LEDs

The primary goal of this report is to benchmark the initial level of performance of a selection of commercial UV LEDs across all three bands (i.e., UV-A, UV-B, UV-C). To provide the initial performance benchmarks, a test matrix containing 13 different UV LED products was created in association with the LED Systems Reliability Consortium (LSRC). The products in this test matrix were all commercially available as of June 2021, and at least 22 samples of each product were tested. In addition, two common, commercial white LEDs were tested to provide a benchmark against blue-pumped white LEDs. Testing of the samples included electrical performance testing (e.g., current-voltage measurements) and photometric testing in a calibrated integrating sphere capable of measuring devices in the UV-A, UV-B, and UV-C bands. The electrical testing provided insights into the performance of the semiconductor layers in the LEDs, allowing parameters such as the threshold voltage (V th ) and serial resistance (R serial ) of each sample to be determined. The photometric testing provided insights into emission wavelengths, peak shapes, and radiant efficiencies for each sample. Combined, the information from these tests permits the overall device efficiencies to be compared and provides insights into the electrical and optical performance of the technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PV Field Performance Including Fleet and Bifacial Field Data

This presentation provides a review of two recent presentations - the 2021 PV Fleet Performance Data Initiative covered by the PVRW presentation, and bifacial system performance presented to a February DuraMAT working group. Details include degradation rate distributions from >6000 inverter channels, monthly performance vs expected, bifacial field studies of energy gain and field degradation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Methanol mixing controlled combustion process enabled by methanol dehydration to dimethyl ether

This work demonstrates an initial proof-of-concept approach for operating a compression ignition off-road and marine relevant engine using neat methanol. The approach utilizes mixing controlled compression ignition (MCCI) of methanol that is enabled by a homogeneous charge compression ignition (HCCI) pre-burn of premixed dimethyl ether (DME). Although two fuels are used, this work explores and evaluates the opportunity and performance to generate the premixed fuel via. methanol catalytic dehydration over an alumina catalyst at engine relevant temperatures, pressures, and space velocities. Conversion purity and species output results from catalytic dehydration bench flow reactor studies were coupled with single cylinder experiments of the characterized output species for pre-burn HCCI performance. Subsequent initial methanol MCCI performance is also evaluated and compared relative to conventional diesel combustion. The detailed flow reactor results show that the catalytic dehydration conversion efficiency of methanol to DME is a function of system pressure, temperature, and space velocity. The engine results demonstrate that a 100% conversion of methanol to DME is not required for successful pre-burn HCCI, and the water formed during the dehydration process does not need to be removed to achieve the desired HCCI event from this pre-burn mixture. Subsequent methanol MCCI combustion results show that the level of methanol slip in the dehydration process affects the pre-burn HCCI phasing, low temperature heat release process, and magnitude of energy released, all of which can dictate the available window for direct injection of methanol for MCCI combustion.

Jatana, Gurneesh [ORNL] (ORCID:0000000288903225)↗

Initial demonstration of automated fuel performance modeling with 1977 EBR-II metallic fuel pins using BISON code with FIPD and IMIS databases

Using the BISON fuel performance code, simulations were conducted using an automated process to read initial and operating conditions from the Fuels Irradiation and Physics Database (FIPD) and Integral Fast Reactor materials information system (IMIS) database, which contains metallic fuel data from the Experimental Breeder Reactor-II (EBR-II). This work demonstrates use of an integrated framework to access the vast majority of EBR-II experimental fuel pin data to support rapid development of fuel performance models for next-generation metallic fuel systems. With this capability, validation for fuel qualification can be performed rapidly. Between IMIS and FIPD, there is enough information to conduct 1977 unique EBR-II metallic fuel pin histories from 24 different experiments, at varying levels of detail between the two databases. Each of these histories includes a high-resolution power history, flux history, coolant channel flow rates, and coolant channel temperatures. Fission gas release (FGR), cumulative damage fraction (CDF), fuel axial swelling, cladding profilometry, and burnup were all simulated in BISON. The results were compared to post-irradiation examination (PIE) results for the initial demonstration of automated BISON modeling. BISON simulations conducted with IMIS and FIPD were in rough agreement with PIE measurements and calculations. Cladding profilometry, FGR, and fuel axial swelling were found to be in rough agreement with PIE measurements, depending on the physics used within the BISON input files. Here, the mechanical contact solver chosen was found to significantly impact axial fuel swelling and cladding strain predictions. CDF values were assessed to see whether pin failure may have been predicted (CDF ≥ 1). This work suggests that continued development of an automated tool for BISON should focus on inclusion of the Fast Flux Test Facility (FFTF) experimental data for a larger database for metallic fuel, improved physical models to better capture fuel performance, such as fuel-cladding interactions, and a more detailed comparison with available PIE data to further the BISON model development.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

De-Risking Large-Scale PV Systems Through Data Analytics

Large-scale photovoltaic system performance analysis is being conducted within the US Department of Energy's-sponsored PV Fleet Performance Data Initiative. This collaboration with commercial PV system owners collects and evaluates PV field performance data, and provides reports on aggregated results. Drawing on over 2200 sites across the US and over 24,000 separate PV inverters we have collected in excess of 8.3 gigawatts (GW) of performance data, representing 6-7% of the entire US installed PV capacity. A mixture of utility-scale and large commercial systems are represented, averaging 4.1 megawatts (MW) in size and 5 years in age. Initial results show average system degradation rates at -0.75% / year, which is slightly higher than historically reported module-level values of -0.5%/year. We also found that the availability of systems averaged 97.7%, which is lower than the typical 99% uptime assumed by many project economic forecasts. Given these results, we compared monthly performance with expected production values, based on satellite weather data and a simple PVWatts performance model. We found that systems were performing within 10% of monthly expectation over 90% of the time, with a fleet average vs expected monthly value of 0.994. We also evaluated the impact of extreme weather events on system performance, and found a range of short-term and longer-term performance effects ranging from grid outage, system downtime, module damage and accelerated long-term degradation rate.

analysis↗

Effect of initial water saturation on the performance of fracturing fluids with and without polyallylamine under simulated EGS conditions

Objectives/Scope: StimuFrac (US Patents 9,873,828 B2 and 9,447,315 B2), a CO 2 - reactive polymer aqueous solution [polyallylamine (PAA) 1wt% in water] combined with CO 2 , can be used as a potentially less water-intensive fracturing fluid for enhanced geothermal systems (EGS). Our previous results show that in hot dry rock (HDR), PAA/CO 2 fracturing fluids outperformed other fluids such as water, CO 2 , and CO 2 /water in generating large fractures with less fluid consumed. The objective of this work is to investigate the effect of initial water saturation on the performance of StimuFrac by conducting hydraulic fracturing tests with ½ foot cubic rock samples held under representative EGS stress/temperature conditions and by using cyclic injection strategies (under constant injection rate). The resulting fracture hydraulic conductivities, breakdown pressures, and volumes of fluids required are compared. Methods/Procedures/Process: To simulate geothermal reservoir conditions, in all tests, the rock sample was held under triaxial confinement and at 200 °C, and different volumes of water were initially injected into the rock sample before any fracturing processes were initiated. For the single-cycle PAA (or water) alternating CO 2 (PAG or WAG) injection fracturing experiments, one complete cycle consisted of two steps: (1) injecting a PAA slug (or water slug) followed by (2) injecting CO 2 to initiate and propagate the fracture. For experiments involving multiple injection cycles, the CO 2 injection pressure is increased until it peaks and begins to decline (indicating fracture initiation at this moment), and then continued being injected for another 30 seconds to propagate the fracture. Then, these two-step cycles [injection of PAA (or water) followed by CO 2 injection (up to 2-4 mL/min)] are repeated. Applications/Significance/Novelty: The results of this study suggest that water saturation significantly affects the fracturing fluid transmission into the rock pore space, thus affecting the fracture initiation and propagation. In this study, fracturing tests via a single injection cycle or multiple injection cycles were performed. Splitting the rock samples in half after testing reveals that fracture propagation is significantly limited under high water saturation conditions (three-day initial water injection) compared to stimulation experiments performed in hot dry rock. The fractures propagate less than 1/3 of the distance from the wellbore to the outer rock surface, and in some cases, no fracture is generated. This may be caused by leak-off dominating the fracturing process and the fluid injection rate is insufficient to overcome leak-off, even under high injection rate conditions. Additionally, CO 2 could be leaking off into the wellbore annulus and this may be making it more difficult to generate sufficiently high-pressure gradients away from the near-wellbore region. Under low water saturation conditions (dry rock or after 1-day initial water injection), PAA/CO 2 consistently generated significantly larger fractures compared with the other fluids. CO 2 generated large fractures only in the hot dry rock and only when using high injection rates, though data variability is high.

58 GEOSCIENCES↗